Page 61
OPTICON Universal menu book
SET
_ZZ_
Not transmit CD
D8
_D8_
Transmit CD
D9
_D9_
Not transmit ST/SP
D1
_D1_
Transmit ST/SP
D0
_D0_
Not transm. ld. A for It. Pharm.Code
DA
_DA_
Transmit leading A for It. Pharm.Code
DB
_DB_
Minimum 3 digits
8D
_8D_
Minimum 1 digit
8E
_8E_
Disable concatenation
+M
_+M_
Enable concatenation
+L
_+L_
END
_ZZ_
U54
Page 62
OPTICON Universal menu book
3.3.5. Options for Codabar Codabar (NW7): Codabar (NW7) is a variable length symbology with an optional check digit and printable start/ stop characters. The next characters are supported: • the digits 0 upto 9 • the characters - $: / . + • start/stop characters are A, B, C or D The checksum is calculated as the sum modulo 16 of the numerical values of all data characters. For string format see figure 3.23.
Fig. 3.23. Options for Codabar Codabar start char.
data (1 or more char.)
check digit stop char.
ABC Code start char.
data (1 or check data (1 or check stop more char.) digit more char.) digit char.
Fig. 3.25. Options for Codabar CX-Code: The CX-Code consists of two bar codes which are decoded in one read cycle. The code is concatenated when the stop character of the first bar code is a C, and the start character of the second bar code is a B. The B and C characters are not transmitted. For string format see figure 3.25.
CX Code start char.
Options for Codabar: • enable ABC code concatenation • enable CX code concatenation • enable check digit check • disable transmission of the check digit • disable transmission of start/stop • selection of start/stop character translation • selection of minimum number of data characters • enable library space (CLSI) insertion
U55 data (1 or check data (1 or check stop more char.) digit more char.) digit char.
3 Code options
Fig. 3.24. Options for Codabar ABC-Code: The ABC code is an acronym for American Blood Commission. This code consists of two bar codes which are decoded in one read cycle. The code is concatenated when the stop character of the first bar code and the start character of the second bar code is a D. These two D's are not transmitted. For string format see figure 3.24.
Page 63
OPTICON Universal menu book
Space insertion: This option inserts spaces in position 2, 7, 13, of the data string for use in library systems.
Fig. 3.26. Options for Codabar Codabar Start and Stop
ST/SP translation: This option enables the translation and transmission of the start and stop characters. Thus if the option ST/SP: abcd/tn*e is chosen, the start character is converted to lower case, e.g. from A, B, C or D to a, b, c, or d respectively and the stop character is converted from A, B, C or D to t, n, *, or e respectively. The next figure shows the resulting format for these options with a Codabar label using A and B as start and stop characters and 1 2 3 4 5 6 as data characters. For string format see figure 3.26.
123456
Not transmit ST/SP
A123456B
ST/SP: ABCD/ABCD a123456b
ST/SP: abcd/abcd
A123456N
ST/SP: ABCD/TN*E a123456n
ST/SP: abcd/tn*e
<DC1> 1 2 3 4 5 6 <DC2>
Minimum data characters: Codabar labels are checked for a minimum of 1, 3 or 5 characters are set by the user. If the number of characters in the label is shorter than the number set, the label will be rejected. If the fixed length option is used for Codabar type labels then such labels will additionally be checked for fixed length. Inter character gap check: This option enables the reading of Codabar labels with a large or irregular gap between characters. Checking the gap means that it is not allowed to have a gap. Disable the gap check allows gaps in the bar code.
U56
<DC1>
ST/SP: ASCII Hex 11
<DC2>
ST/SP: ASCII Hex 12
<DC3>
ST/SP: ASCII Hex 13
<DC4>
ST/SP: ASCII Hex 14
Page 64
OPTICON Universal menu book
3.3.5. Options for Codabar
_ZZ_
Enable only Codabar normal mode
HA
_HA_
Enable only ABC code
H4
_H4_
Enable only CX code
H5
_H5_
Enable Codabar, ABC and CX
H3
_H3_
Not check CD
H7
_H7_
Check CD
H6
_H6_
Not transmit CD
H9
_H9_
Transmit CD
H8
_H8_
Disable space insertion
HE
_HE_
Enable space insertion
HD
_HD_
Not transmit ST/SP
F0
_F0_
ST/SP: ABCD/ABCD
F3
_F3_
ST/SP: abcd/abcd
F4
_F4_
END
_ZZ_ U57
3 Code options
SET
Page 65
OPTICON Universal menu book
SET
_ZZ_
ST/SP: ABCD/TN*E
F1
_F1_
ST/SP: abcd/tn*e
F2
_F2_
HJ
_HJ_
Minimum data one character
HC
_HC_
Minimum data three characters
HB
_HB_
Minimum data five characters
HF
_HF_
Disable intercharacter gap check
HI
_HI_
Enable intercharacter gap check
HH
_HH_
END
_ZZ_
ST/SP: <DC1><DC2><DC3><DC4>/ <DC1><DC2><DC3><DC4>
U58
Page 66
OPTICON Universal menu book
3.3.6. Options for 2of5 and S-Code Options for code 2of5: • disable transmission of the check digit • enable check digit check • selection of the minimum number of data characters • disable space check for industrial 2of5 • transmit S-Code as Interleaved 2of5
Code 2of5: Code 2of5 is a variable length symbology with an optional check digit and non printable start and stop characters. The following characters are supported: • the digits 0 upto 9 The checksum is calculated as the sum modulo 10 of the numerical values of all the data characters. Industrial 2of5: This symbology encodes a single digit in each data symbol. Information is carried in the bars only. Interleaved 2of5: This symbology encodes a pair of digits in each symbol, the number of digits are therefore always an even number. Information is carried in the bars and spaces. The start and stop pattern is not unique inside the code. It is therefore essential to use the fixed length option to prevent partial reads.
Space check: This option enables the reading of Industrial 2of5 labels with a large or irregular spacing. Transmit S-Code as Interleaved 2of5: This option enables to transmit S-Code as Interleaved 2of5 by adding a leading zero.
S-Code: This symbology encodes like Interleaved 2of5 but encodes the last data character as Industrial 2of5. The number of data digits is therefore always an odd number. Information is carried in the bars and the spaces.The start and stop pattern is not unique inside the code. It is therefore essential to use the fixed length option to prevent partial reads.
Fig. 3.27. Options for 2of5 and S-Code Industrial 2of5, Interleaved 2of5, S-Code, Matrix 2of5, Chinese Post Matrix 2of5 leading zero (optional)
Matrix 2of5: This symbology encodes 1 digit in each character, the number of digits can therefore be an odd or an even number. Information is carried in the bars and spaces. Chines Post Matrix 2of5: This symbology is a variant of Matrix 2of5. To assure proper reads, check the options and setting for (Matrix) 2of5. For string format of the supported symbologies see figure 3.27.
U59 data (1 or more digits)
check digit
3 Code options
Minimum data characters: Code 2of5 are checked for a minimum of 1, 3 or 5 characters as set by the user. If the number of characters in the label is less then the number set, the label will be rejected. If the fixed length option is used for a Code 2of5 type label, than such label will additionally be checked for fixed length.
Page 67
OPTICON Universal menu book
3.3.6. Options for 2of5 and S-Code
SET
_ZZ_
Not transmit CD
E1
_E1_
Transmit CD
E0
_E0_
Not check CD
G0
_G0_
Check CD
G1
_G1_
Minimum data one character
GE
_GE_
Minimum data three character
GF
_GF_
Minimum data five character
GI
_GI_
Disable space check for Industrial 2of5
GK
_GK_
Enable space check for Industrial 2of5
GJ
_GJ_
Not transmit S-Code as Interleaved 2of5
GH
_GH_
Transmit S-Code as Interleaved 2of5
GG
_GG_
END
_ZZ_
U60
Page 68
OPTICON Universal menu book
3.3.7. Options for IATA Check digit calculation: If the check digit calculation is required, then the appropriate calculation method must be selected.
The IATA code is a variable length symbology with an optional check digit and non printable start/stop characters. The following characters are supported: • the digits 0 upto 9 The checksum is calculated as the modulo seven of the data string. IATA is acronym for International Air Transport Association. For string format see figure 3.28.
Fig. 3.28. Options for IATA IATA CPN coupon (1digit)
AC airline code (3 digits)
FC form code (2 digits)
SET
_ZZ_
Not check CD
4H
_4H_
Check FC and SN only
4I
_4I_
Check CPN, FC and SN
4J
_4J_
Check CPN, AC, FC and SN
4K
_4K_
Not transmit CD
4M
_4M_
Transmit CD
4L
_4L_
END
_ZZ_
U61
SN serial number (8 digits)
CD check digit (1 digit)
3 Code options
Options for IATA: • enable check digit check • selection of the check digit calculation • disable transmission of the check digit
Page 69
OPTICON Universal menu book
3.3.8. Options for MSI/Plessey MSI Plessey is a variable length symbology with one or two optional check digit calculations CD1 and CD2 and non printable start/stop characters. The following characters are supported: • the digits 0 up to 9
Fig. 3.29. Options for MSI/Plessey MSI/Plessey data (1 upto 13 digits)
The checksum is calculated as the sum modulo 10 or 11 of the data characters. The checksum CD2 is calculated as the sum modulo 10 or 11 of the data characters and CD1. For string format see figure 3.29. Options for MSI/Plessey: • disable check digit check • selection of the check digit calculation • selection of the number of check digits to be transmitted Check digit: If the check digit calculation is required, then the appropriate calculation method must be selected. Not transmit CD: The character positions CD1 and CD2 are not transmitted. Transmit CD1: The character position CD2 is not transmitted. Transmit CD1 and CD2: All characters in the label are transmitted.
U62 cd1 cd2
Page 70
OPTICON Universal menu book
3.3.8. Options for MSI/Plessey
_ZZ_
Not check CD
4A
_4A_
Check 1 CD = MOD 10
4B
_4B_
Check 2 CD's = MOD 10/ MOD 10
4C
_4C_
Check 2 CD's = MOD 10/ MOD 11
4D
_4D_
Check 2 CD's = MOD 11/ MOD 10
4R
_4R_
Not transmit CD
4G
_4G_
Transmit CD1
4E
_4E_
Transmit CD1 and CD2
4F
_4F_
END
_ZZ_
U63
3 Code options
SET