Page 61

OPTICON Universal menu book

SET

_ZZ_

Not transmit CD

D8

_D8_

Transmit CD

D9

_D9_

Not transmit ST/SP

D1

_D1_

Transmit ST/SP

D0

_D0_

Not transm. ld. A for It. Pharm.Code

DA

_DA_

Transmit leading A for It. Pharm.Code

DB

_DB_

Minimum 3 digits

8D

_8D_

Minimum 1 digit

8E

_8E_

Disable concatenation

+M

_+M_

Enable concatenation

+L

_+L_

END

_ZZ_

U54

Page 62

OPTICON Universal menu book

3.3.5. Options for Codabar Codabar (NW7): Codabar (NW7) is a variable length symbology with an optional check digit and printable start/ stop characters. The next characters are supported: • the digits 0 upto 9 • the characters - $: / . + • start/stop characters are A, B, C or D The checksum is calculated as the sum modulo 16 of the numerical values of all data characters. For string format see figure 3.23.

Fig. 3.23. Options for Codabar Codabar start char.

data (1 or more char.)

check digit stop char.

ABC Code start char.

data (1 or check data (1 or check stop more char.) digit more char.) digit char.

Fig. 3.25. Options for Codabar CX-Code: The CX-Code consists of two bar codes which are decoded in one read cycle. The code is concatenated when the stop character of the first bar code is a C, and the start character of the second bar code is a B. The B and C characters are not transmitted. For string format see figure 3.25.

CX Code start char.

Options for Codabar: • enable ABC code concatenation • enable CX code concatenation • enable check digit check • disable transmission of the check digit • disable transmission of start/stop • selection of start/stop character translation • selection of minimum number of data characters • enable library space (CLSI) insertion

U55 data (1 or check data (1 or check stop more char.) digit more char.) digit char.

3 Code options

Fig. 3.24. Options for Codabar ABC-Code: The ABC code is an acronym for American Blood Commission. This code consists of two bar codes which are decoded in one read cycle. The code is concatenated when the stop character of the first bar code and the start character of the second bar code is a D. These two D's are not transmitted. For string format see figure 3.24.

Page 63

OPTICON Universal menu book

Space insertion: This option inserts spaces in position 2, 7, 13, of the data string for use in library systems.

Fig. 3.26. Options for Codabar Codabar Start and Stop

ST/SP translation: This option enables the translation and transmission of the start and stop characters. Thus if the option ST/SP: abcd/tn*e is chosen, the start character is converted to lower case, e.g. from A, B, C or D to a, b, c, or d respectively and the stop character is converted from A, B, C or D to t, n, *, or e respectively. The next figure shows the resulting format for these options with a Codabar label using A and B as start and stop characters and 1 2 3 4 5 6 as data characters. For string format see figure 3.26.

123456

Not transmit ST/SP

A123456B

ST/SP: ABCD/ABCD a123456b

ST/SP: abcd/abcd

A123456N

ST/SP: ABCD/TN*E a123456n

ST/SP: abcd/tn*e

<DC1> 1 2 3 4 5 6 <DC2>

Minimum data characters: Codabar labels are checked for a minimum of 1, 3 or 5 characters are set by the user. If the number of characters in the label is shorter than the number set, the label will be rejected. If the fixed length option is used for Codabar type labels then such labels will additionally be checked for fixed length. Inter character gap check: This option enables the reading of Codabar labels with a large or irregular gap between characters. Checking the gap means that it is not allowed to have a gap. Disable the gap check allows gaps in the bar code.

U56

<DC1>

ST/SP: ASCII Hex 11

<DC2>

ST/SP: ASCII Hex 12

<DC3>

ST/SP: ASCII Hex 13

<DC4>

ST/SP: ASCII Hex 14

Page 64

OPTICON Universal menu book

3.3.5. Options for Codabar

_ZZ_

Enable only Codabar normal mode

HA

_HA_

Enable only ABC code

H4

_H4_

Enable only CX code

H5

_H5_

Enable Codabar, ABC and CX

H3

_H3_

Not check CD

H7

_H7_

Check CD

H6

_H6_

Not transmit CD

H9

_H9_

Transmit CD

H8

_H8_

Disable space insertion

HE

_HE_

Enable space insertion

HD

_HD_

Not transmit ST/SP

F0

_F0_

ST/SP: ABCD/ABCD

F3

_F3_

ST/SP: abcd/abcd

F4

_F4_

END

_ZZ_ U57

3 Code options

SET

Page 65

OPTICON Universal menu book

SET

_ZZ_

ST/SP: ABCD/TN*E

F1

_F1_

ST/SP: abcd/tn*e

F2

_F2_

HJ

_HJ_

Minimum data one character

HC

_HC_

Minimum data three characters

HB

_HB_

Minimum data five characters

HF

_HF_

Disable intercharacter gap check

HI

_HI_

Enable intercharacter gap check

HH

_HH_

END

_ZZ_

ST/SP: <DC1><DC2><DC3><DC4>/ <DC1><DC2><DC3><DC4>

U58

Page 66

OPTICON Universal menu book

3.3.6. Options for 2of5 and S-Code Options for code 2of5: • disable transmission of the check digit • enable check digit check • selection of the minimum number of data characters • disable space check for industrial 2of5 • transmit S-Code as Interleaved 2of5

Code 2of5: Code 2of5 is a variable length symbology with an optional check digit and non printable start and stop characters. The following characters are supported: • the digits 0 upto 9 The checksum is calculated as the sum modulo 10 of the numerical values of all the data characters. Industrial 2of5: This symbology encodes a single digit in each data symbol. Information is carried in the bars only. Interleaved 2of5: This symbology encodes a pair of digits in each symbol, the number of digits are therefore always an even number. Information is carried in the bars and spaces. The start and stop pattern is not unique inside the code. It is therefore essential to use the fixed length option to prevent partial reads.

Space check: This option enables the reading of Industrial 2of5 labels with a large or irregular spacing. Transmit S-Code as Interleaved 2of5: This option enables to transmit S-Code as Interleaved 2of5 by adding a leading zero.

S-Code: This symbology encodes like Interleaved 2of5 but encodes the last data character as Industrial 2of5. The number of data digits is therefore always an odd number. Information is carried in the bars and the spaces.The start and stop pattern is not unique inside the code. It is therefore essential to use the fixed length option to prevent partial reads.

Fig. 3.27. Options for 2of5 and S-Code Industrial 2of5, Interleaved 2of5, S-Code, Matrix 2of5, Chinese Post Matrix 2of5 leading zero (optional)

Matrix 2of5: This symbology encodes 1 digit in each character, the number of digits can therefore be an odd or an even number. Information is carried in the bars and spaces. Chines Post Matrix 2of5: This symbology is a variant of Matrix 2of5. To assure proper reads, check the options and setting for (Matrix) 2of5. For string format of the supported symbologies see figure 3.27.

U59 data (1 or more digits)

check digit

3 Code options

Minimum data characters: Code 2of5 are checked for a minimum of 1, 3 or 5 characters as set by the user. If the number of characters in the label is less then the number set, the label will be rejected. If the fixed length option is used for a Code 2of5 type label, than such label will additionally be checked for fixed length.

Page 67

OPTICON Universal menu book

3.3.6. Options for 2of5 and S-Code

SET

_ZZ_

Not transmit CD

E1

_E1_

Transmit CD

E0

_E0_

Not check CD

G0

_G0_

Check CD

G1

_G1_

Minimum data one character

GE

_GE_

Minimum data three character

GF

_GF_

Minimum data five character

GI

_GI_

Disable space check for Industrial 2of5

GK

_GK_

Enable space check for Industrial 2of5

GJ

_GJ_

Not transmit S-Code as Interleaved 2of5

GH

_GH_

Transmit S-Code as Interleaved 2of5

GG

_GG_

END

_ZZ_

U60

Page 68

OPTICON Universal menu book

3.3.7. Options for IATA Check digit calculation: If the check digit calculation is required, then the appropriate calculation method must be selected.

The IATA code is a variable length symbology with an optional check digit and non printable start/stop characters. The following characters are supported: • the digits 0 upto 9 The checksum is calculated as the modulo seven of the data string. IATA is acronym for International Air Transport Association. For string format see figure 3.28.

Fig. 3.28. Options for IATA IATA CPN coupon (1digit)

AC airline code (3 digits)

FC form code (2 digits)

SET

_ZZ_

Not check CD

4H

_4H_

Check FC and SN only

4I

_4I_

Check CPN, FC and SN

4J

_4J_

Check CPN, AC, FC and SN

4K

_4K_

Not transmit CD

4M

_4M_

Transmit CD

4L

_4L_

END

_ZZ_

U61

SN serial number (8 digits)

CD check digit (1 digit)

3 Code options

Options for IATA: • enable check digit check • selection of the check digit calculation • disable transmission of the check digit

Page 69

OPTICON Universal menu book

3.3.8. Options for MSI/Plessey MSI Plessey is a variable length symbology with one or two optional check digit calculations CD1 and CD2 and non printable start/stop characters. The following characters are supported: • the digits 0 up to 9

Fig. 3.29. Options for MSI/Plessey MSI/Plessey data (1 upto 13 digits)

The checksum is calculated as the sum modulo 10 or 11 of the data characters. The checksum CD2 is calculated as the sum modulo 10 or 11 of the data characters and CD1. For string format see figure 3.29. Options for MSI/Plessey: • disable check digit check • selection of the check digit calculation • selection of the number of check digits to be transmitted Check digit: If the check digit calculation is required, then the appropriate calculation method must be selected. Not transmit CD: The character positions CD1 and CD2 are not transmitted. Transmit CD1: The character position CD2 is not transmitted. Transmit CD1 and CD2: All characters in the label are transmitted.

U62 cd1 cd2

Page 70

OPTICON Universal menu book

3.3.8. Options for MSI/Plessey

_ZZ_

Not check CD

4A

_4A_

Check 1 CD = MOD 10

4B

_4B_

Check 2 CD's = MOD 10/ MOD 10

4C

_4C_

Check 2 CD's = MOD 10/ MOD 11

4D

_4D_

Check 2 CD's = MOD 11/ MOD 10

4R

_4R_

Not transmit CD

4G

_4G_

Transmit CD1

4E

_4E_

Transmit CD1 and CD2

4F

_4F_

END

_ZZ_

U63

3 Code options

SET