Page 51

OPTICON Universal menu book

Minimum length for selected codes: This option modifies the default minimum length table. The number of minimum lengths which can be configured is reader dependent. This is done by reading the following labels: <SET> <Minimum length for selected codes> Scan bar codes of the required type and length <END>

Maximum length for selected codes: This option enables the maximum length checking. The number of maximum lengths which can be configured is reader dependent. This is done by reading the following labels: <SET> <Maximum length for selected codes> Scan bar codes of the required type and length <END>

Example: The two examples shown in the next figure have the following result: In the first example only Code 39 labels will be checked for a minimum length of 2 characters. All other bar code types will be checked for a minimum length as displayed in the next figure. In the second example Code 39 labels will be checked for a minimum length of 2 characters and Interleaved 2of5 labels for a minimum length of 4 characters. This implies that also Industrial 2of5, Matrix 2of5 and S-Code are checked for a minimum length of 4 characters. All other bar code types will be checked for a minimum length as per figure 3.09.

Example: The two following examples shown in the next figure have the following result: In the first example only Code 39 labels will be checked for a maximum length of 12 characters. Any other bar code types will not be checked for a maximum length. In the second example Code 39 labels will be checked for a maximum length of 12 characters and Interleaved 2of5 labels for a maximum length of 14 characters. This implies that also Industrial 2of5, Matrix 2of5 and S-Code are checked for a maximum length of 14 characters. Any other bar code types will not be checked for a maximum length. See figure 3.10.

Fig. 3.09. Setting Minimum length for selected codes

Fig. 3.10. Setting Maximum length for selected codes

SET

SET

SET

SET

Minimum length for selected codes

Minimum length for selected codes

Maximum length for selected codes

Maximum length for selected codes

Scan a label, i.e. Code 39 with length = 2

Scan a label, i.e. Code 39 with length = 2

Scan a label, i.e. Code 39 with length = 12

Scan a label, i.e. Code 39 with length = 12

END

Scan a label, i.e. Interleaved 2of5 with length = 4

END

Scan a label, i.e. Interleaved 2of5 with length = 14

END

END

U44

Page 52

OPTICON Universal menu book

Serial programming: To set a length using serial commands, the sequence is as follows: <ESC> <command> <SPACE>*<CodeID>* <Length 1> <Length 2**> <CR> *(if required by <command>) **(length 2 may be the same length as length 1, when only one length is required)

3 Code options

Example: Setting fixed length for all codes, lengths 8, 10 and 12: • <ESC>H1081012<CR> Setting minimum length for selected codes, for Code 39 with a length of 2: • <ESC>HL V02<CR> Setting maximum length for selected codes, for Code 39 with a length of 12 and Interleaved 2of5 with length of 14: • <ESC>HM V12 N14<CR>

3.2. Setting of number of characters

SET

_ZZ_

Fixed length OFF all codes

H0

_H0_

Fixed length ON all codes

H1

_H1_

Fixed length ON for selected codes

HK

_HK_

Minimum length for selected codes

HL

_HL_

Maximum length for selected codes

HM

_HM_

END

_ZZ_ U45

Page 53

OPTICON Universal menu book

3.3. Setting code specific options Not transmit CD: This option disables the transmission of the check digit. If the check digit calculation is disabled, the reader can not differentiate between a (valid) check digit and a data character. It will therefore transmit all data characters of the label, excluding the character that could constitute the check digit for the type of bar code.

Code specific options may be configured affecting: • enabling and disabling code variants and translations, such as EAN-128, as were listed in the relations table for setting of readable codes • data verification such as by means of a check digit calculation. A check digit has a value that can be calculated from the other data characters and is usually the last data character in a bar code • pre-editing of the data string such as removing the check-digit and/or start/stop characters

Transmit ST/SP: This option enables the transmission of the start and stop characters of a bar code. Not transmit ST/SP: This option disables the transmission of the start and stop characters of a bar code. The next figure summarizes the effect of the transmit options for a Code 39 label with: • start and stop characters '*' • data characters '1 2 3 4 5 6' • or data characters '1 2 3 4 5' and check digit '6'

The more common options are described here: Check CD: This option enables the check digit calculation. If the calculated check digit does not correspond to the check digit in the bar code, then the bar code is ignored. The use of a check digit greatly improves the security of a bar code.

Note that because '6' is, according to the Code 39 specifications, not a valid check digit for this label. The check digit calculation must therefore be disabled in order for the label to be accepted.

Not check CD: This option disables the check digit calculation. This option is required when the bar codes do not contain a check digit or contain an invalid check digit.

See figure 3.11.

Transmit CD: This option enables the transmission of the check digit together with the data characters. If the check digit calculation is disabled, the reader can not differentiate anymore between a (valid) check digit and a data character. It will therefore transmit all data characters of the label, including what could constitute a check digit.

Fig. 3.11. Setting code specific options

U46

Transmit CD

Not transmit CD

Transmit ST/SP

*123456*

*12345*

Not transmit ST/SP

123456

12345

Page 54

OPTICON Universal menu book

3.3.1. Options for UPC-A The UPC-A symbology is a fixed length symbology encoding 11 data digits, a check digit and non printable start/stop characters. The following characters are supported: • the digits 0 up to 9

Fig. 3.12. Options for UPC-A UPC-A leading zero

An optional leading zero can be transmitted, which together with the data and the check digit forms a 13 digit field providing compatibility with the EAN-13 format. For string format see figure 3.12.

data (11 digits)

check digit

3

Fig. 3.13. Options for UPC-A leading zero data (11 digits)

Options for UPC-A: • disable transmission of the leading zero • disable transmission of the check digit

SET

_ZZ_

UPC-A, No leading zero, transmit CD

E3

_E3_

UPC-A, No leading zero, not transmit CD

E5

_E5_

UPC-A, Leading zero, transmit CD

E2

_E2_

UPC-A, Leading zero, not transmit CD

E4

_E4_

END

_ZZ_

U47 check digit add-on 2 or 5

Code options

UPC-A, +2, +5

UPC-A add-on 2/add-on 5: The UPC-A symbology as described above can be succeeded by an additional 2 or 5 digit UPCA code. For string format see figure 3.13.

Page 55

OPTICON Universal menu book

3.3.2. Options for UPC-E The UPC-E symbology is a fixed length symbology encoding 6 data digits, a check digit and non printable start/stop characters. The following characters are supported: • the digits 0 upto 9

Fig. 3.14. Options for UPC-E UPC-E leading digit (0 or 1)

An optional leading digit can be transmitted, which together with the data and the check digit forms an 8 digit field providing a compatibility with the EAN-8 format. For string format see figure 3.14.

data (6 digits)

check digit

Fig. 3.15. Options for UPC-E

UPC-E add-on 2/add-on 5: The UPC-E symbology as described above can be succeeded by an additional 2 or 5 digit UPCE code. For string format see figure 3.15.

UPC-E, +2, +5 leading digit (0 or 1)

UPC-E0 stands for UPC version E0 and the first digit is always a '0'. UPC-E1 stand for UPC version E1 and the first digit is a '1'. Options for UPC-E0 affects UPC-E1 too. Support for UPCE1 is reader dependent. Options for UPC-E: • enable transmission of the leading digit • disable transmission of the check digit • transmit UPC-E as UPC-A Transmit UPC-E as UPC-A: If this option is enabled, a UPC-E label is transmitted in the UPC-A format.

U48 data (6 digits)

check digit add-on 2 or 5

Page 56

OPTICON Universal menu book

3.3.2. Options for UPC-E

_ZZ_

UPC-E, No leading digit, transmit CD

E7

_E7_

UPC-E, No leading digit, not transmit CD

E9

_E9_

UPC-E, Leading digit, transmit CD

E6

_E6_

UPC-E, Leading digit, not transmit CD

E8

_E8_

Transmit UPC-E as is

6Q

_6Q_

Transmit UPC-E as UPCA

6P

_6P_

END

_ZZ_

U49

3 Code options

SET

Page 57

OPTICON Universal menu book

3.3.3. Options for EAN-13 and EAN-8 EAN-13: The EAN-13 symbology is a fixed length symbology encoding 12 data digits, a check digit and non printable start/stop characters. The following characters are supported: • the digits 0 upto 9

Fig. 3.16. Options for EAN-13 and EAN-8 EAN-13 data (12 digits)

check digit

The data may be translated into ISBN, ISSN or ISMN format. For string format see figure 3.16. EAN-13 add-on 2/add-on 5: The EAN-13 symbology as described above can be succeeded by an additional 2 or 5 digit code. For string format see figure 3.17.

Fig. 3.17. Options for EAN-13 and EAN-8 EAN-13, +2,+5 data (12 digits)

EAN-8: The EAN-8 symbology is a fixed length symbology encoding 7 data digits, a check digit and non printable start/stop characters. The following characters are supported: • the digits 0 upto 9 For string format see figure 3.18.

check digit add-on 2 or 5

Fig. 3.18. Options for EAN-13 and EAN-8 EAN-8

EAN-8 add-on 2/add-on 5: The EAN-8 symbology as described above can be succeeded by an additional 2 or 5 digit code. For string format see figure 3.19.

data (7 digits)

Options for EAN: • disable transmission of the check digit • enable ISBN, ISSN or ISMN translation check digit

Fig. 3.19. Options for EAN-13 and EAN-8 EAN-8, +2,+5

Enable ISBN, ISSN or ISMN translation: If this option is enabled, an EAN-13 label is verified for the correct format and transmitted as a 10-digit ISBN number, 8 digit ISSN number. In case of ISMN, the character M is transmitted followed by 9 digits. Support for these translations is reader dependent.

data (7 digits)

U50 check digit add-on 2 or 5

Page 58

OPTICON Universal menu book

3.3.3. Options for EAN-13 and EAN-8

_ZZ_

EAN-13 not transmit CD

6J

_6J_

EAN-13 transmit CD

6K

_6K_

EAN-8 not transmit CD

6H

_6H_

EAN-8 transmit CD

6I

_6I_

Disable ISBN translation

IB

_IB_

Enable ISBN translation

IA

_IA_

Enable ISBN if possible

IK

_IK_

Disable ISSN translation

HN

_HN_

Enable ISSN translation

HO

_HO_

Enable ISSN if possible

4V

_4V_

Disable ISMN translation

IO

_IO_

Enable ISMN translation

IP

_IP_

Enable ISMN if possible

IQ

_IQ_

END

_ZZ_ U51

3 Code options

SET

Page 59

OPTICON Universal menu book

3.3.4. Options for Code 39 and It. Pharm. Italian Pharmaceutical only: In this mode the decoded data characters are translated to the Italian Pharmaceutical format. If the data does not comply with the Italian Pharmaceutical format, the label is rejected.

Code 39: Code 39 is a variable length symbology with an optional check digit and printable start/stop characters. The following characters are supported: • the digits 0 up to 9 • the upper case characters A up to Z • the characters - . $ / + % SPACE • start/stop character is *

Italian Pharmaceutical if possible: In this mode the decoded data characters are translated to the Italian Pharmaceutical format. If the data does not comply with the Italian Pharmaceutical format, then the data is transmitted as Normal or full ASCII Code 39.

The checksum is calculated as the sum modulo 43 of the numerical value of the data characters. In full ASCII mode, all 128 ASCII characters are supported. This is done by combining one of the characters +, %, $ or / with one of the alpha characters (A upto Z). For string format see figure 3.20.

Tri-Optic: This fixed length symbology builds its data out of two data triplets, where the second triplet is encoded at first. The following characters are supported: • the digits 0 up to 9 • the upper case characters A up to Z • the characters - . / + % SPACE • start/stop character is $ For string format see figure 3.22. There are no options for Tri-Optic supported.

Italian Pharmaceutical: In this mode the Code 39 data is translated to the Italian pharmaceutical format. This format has a fixed length containing 8 numeric data values followed by a single mandatory check digit. An optional leading 'A' can be transmitted. For string format see figure 3.21.

Concatenation: If a Code 39 bar code contains a leading space, the data is stored into the reader's buffer without the leading space. As soon as a Code 39 bar code is read without a leading space, the data is appended to the reader's buffer and the entire buffer is transmitted and cleared for new data. In case a non Code 39 bar code is read, the data in the non-Code 39 bar code is transmitted and the buffer is cleared. The buffer size is reader dependent.

Options for Code 39: • enable full ASCII conversion • enable Italian Pharmaceutical conversion • enable check digit • disable transmission of the check digit • enable transmission of start/stop • enable leading A for Italian Pharmaceutical • selection of the minimum number of data characters Normal Code 39: In this mode the decoded data characters are transmitted without further translation. Full ASCII Code 39: In this mode the decoded data characters are translated to full ASCII Code 39. Full ASCII Code 39 if possible: In this mode the decoded data characters are translated to full ASCII Code 39. Invalid combinations are not translated and are transmitted as is.

U52

Page 60

OPTICON Universal menu book

Fig. 3.20. Options for Code 39 and It.Pharm.

Fig. 3.21. Options for Code 39 and It.Pharm.

Code 39

Italian Pharmaceutical start char.

data (0 or more char.)

check digit start char.

stop char.

leading A data (8 digits)

check stop digit char.

Fig. 3.22. Options for Code 39 and It.Pharm.

start char.

data triplet 2 + triplet 1 ( 3 + 3 digits = 6 total )

3.3.4. Options for Code 39 and It.Pharm.

SET

_ZZ_

Normal Code 39

D5

_D5_

Full ASCII Code 39

D4

_D4_

Full ASCII Code 39 if possible

+K

_+K_

It. Pharmaceutical only

D6

_D6_

It. Pharmaceutical if possible

D7

_D7_

Not check CD

C1

_C1_

Check CD

C0

_C0_

END

_ZZ_ U53 stop char.