Page 41
OPTICON Universal menu book
3.1. Setting of readable codes Example 2: If you want to read one of the special bar codes that is a variation of the readable code, read the single read. code option followed by the dedicated variation option from the applicable symbology options chapter. • EAN128 only: read the option 'Code 128 only' followed by 'Enable EAN-128 only' from the 'Options for Code 128'. • Italian Pharmaceutical: read Enable Code 39 only, followed by the option 'Italian Pharmaceutical only' from the 'Options for Code 39'. See figure 3.02.
These options do not affect the reading of the menu labels. The required bar code types can be selected by enabling a single readable code only and enabling readable codes. It is strongly recommended to select only the required codes. Advantages of selecting only the required codes are: • faster reading • no accidental scanning of unwanted bar codes • reduced probability of reading errors which can not be prevented completely, because of the limited security of some bar code types
Fig. 3.02. Enabling a single readable code: Special variations
Some bar codes are translations or special variants of other bar code types. The table on the title page of this chapter visualizes these relations. The setting of different codes is explained in the next chapter 3.1.1. Enabling a single read. code.
GS1-128
Italian Pharmaceutical
SET
SET
Enabling a single read. code a single read. code Enabling
Code 128 only
3.1.1. Enabling a single read. code
Enabling a single read. code
Code 39 only
Options for Code 39 and Options for Options for Code Code 128 39 and It. Pharm It. Pharm
With this option you can set the reader to read a single bar code type only. If you select 'Code 39 only', no other codes will be read.
It. Pharmaceutical only GS1-128 only It. Pharmaceutical only END
Example 1: If you want to read Code 39 only, you read the option 'Code 39 only'. See figure 3.01.
END
Example 3: If you want to read a code that is changed to another family name, read the new name. • RSS+14: read the option ‘GS1 Databar’. See figure 3.03.
Fig. 3.01. Enabling a single readable code: Symbology only Code 39
Fig. 3.03. Enabling a single readable code: New family name
SET
RSS-14
Code 39 only
SET
END
GS1 Databar only END
U34
Page 42
OPTICON Universal menu book
3.1.1. Enabling a single read. code
_ZZ_
All codes excl. add-on
A0
_A0_
Only all UPC and EAN codes
J0
_J0_
UPC only
J1
_J1_
UPC + 2 only
J2
_J2_
UPC + 5 only
J3
_J3_
EAN only
J4
_J4_
EAN + 2 only
J5
_J5_
EAN + 5 only
J6
_J6_
Code 39 only
A2
_A2_
Tri-Optic only
JD
_JD_
Codabar only
A3
_A3_
Industrial 2of5 only
J7
_J7_
Interleaved 2of5 only
J8
_J8_
END
_ZZ_ U35
3 Code options
SET
Page 43
OPTICON Universal menu book
SET
_ZZ_
S-Code only
RA
_RA_
Matrix 2of5 only
AB
_AB_
Chinese Post Matrix 2of5 only
JE
_JE_
Korean Postal Authority code only
JL
_JL_
Intelligent Mail Barcode only
D5H
_D5H_
POSTNET only
D6C
_D6C_
IATA only
A4
_A4_
MSI/Plessey only
A7
_A7_
Telepen only
A9
_A9_
UK/Plessey only
A1
_A1_
Code 128 only
A6
_A6_
Code 93 only
A5
_A5_
Code 11 only
BLB
_BLB_
END
_ZZ_
U36
Page 44
OPTICON Universal menu book
_ZZ_
GS1 DataBar only
J9
_J9_
GS1 DataBar Limited only
JJ
_JJ_
GS1 DataBar Expanded only
JK
_JK_
Codablock F only
D4R
_D4R_
DataMatrix ECC000 140 only
BG2
_BG2_
DataMatrix ECC200 only
BC0
_BC0_
Aztec only
BC5
_BC5_
Aztec runes only
BF4
_BF4_
Chinese Sensible code only
D4K
_D4K_
QR Code only
BC1
_BC1_
Micro QR Code only
D38
_D38_
Maxicode only
BC2
_BC2_
PDF417 only
BC3
_BC3_
END
_ZZ_
U37
3 Code options
SET
Page 45
OPTICON Universal menu book
SET
_ZZ_
MicroPDF417 only
BC4
_BC4_
Enable all 1D codes only
BCA
_BCA_
Enable all 2D codes only
BCB
_BCB_
END
_ZZ_
3.1.2. Enabling of readable codes With this option you can set the reader to read a number of bar code types or simply enable additional bar code types. Example of addition: If you want to enable Codabar in addition to what you already have configured, you read 'Enable Codabar'. See figure 3.05.
Example: If you only want to read Code 39 and Code 128, you read 'Code 39 only' and 'enable Code 128'. Alternatively you can read 'Disable All', 'Enable Code 39' and 'Enable Code 128'. See figure 3.04.
Fig. 3.05. Enabling of readable codes addition Fig. 3.04. Enabling of readable codes
SET
SET
Code 39 only
Disable All
Enable Code 128
Enable Code 39
END
Enable Code 128
SET Enable Codabar END
END
U38
Page 46
OPTICON Universal menu book
3.1.2. Enabling of readable codes
_ZZ_
All codes excl. add-on
A0
_A0_
Enable UPC
R1
_R1_
Enable UPC + 2
R2
_R2_
Enable UPC + 5
R3
_R3_
Enable EAN
R4
_R4_
Enable EAN + 2
R5
_R5_
Enable EAN + 5
R6
_R6_
Enable Code 39
B2
_B2_
Enable Tri-Optic
JZ
_JZ_
Enable Codabar
B3
_B3_
Enable Industrial 2of5
R7
_R7_
Enable Interleaved 2of5
R8
_R8_
Enable S-Code
R9
_R9_
END
_ZZ_ U39
3 Code options
SET
Page 47
OPTICON Universal menu book
SET
_ZZ_
Enable Matrix 2of5
BB
_BB_
Enable Chinese Post Matrix 2of5
JS
_JS_
Enable Korean Postal Authority code
WH
_WH_
Enable Intelligent Mail Barcode
D5F
_D5F_
Enable POSTNET
D6A
_D6A_
Enable IATA
B4
_B4_
Enable MSI/Plessey
B7
_B7_
Enable Telepen
B9
_B9_
Enable UK/Plessey
B1
_B1_
Enable Code 128
B6
_B6_
Enable Code 93
B5
_B5_
Enable Code 11
BLC
_BLC_
Enable GS1-Databar
JX
_JX_
END
_ZZ_
U40
Page 48
OPTICON Universal menu book
_ZZ_
Enable GS1-Databar Limited
JY
_JY_
Enable GS1-Databar Expanded
DR
_DR_
Enable Codablock F
D4P
_D4P_
Enable DataMatrix ECC000 - 140
BG0
_BG0_
Enable DataMatrix ECC200
BCC
_BCC_
Enable Aztec
BCH
_BCH_
Enable Aztec runes
BF2
_BF2_
Enable Chinese Sensible code
D4L
_D4L_
Enable QR Code
BCD
_BCD_
Enable Micro QR Code
D2U
_D2U_
Enable Maxicode
BCE
_BCE_
Enable PDF417
BCF
_BCF_
Enable MicroPDF417
BCG
_BCG_
END
_ZZ_
U41
3 Code options
SET
Page 49
OPTICON Universal menu book
SET
_ZZ_
Enable all 1D codes
BCM
_BCM_
Enable all 2D codes
BCN
_BCN_
Disable all
B0
_B0_
END
_ZZ_
3.2. Setting of number of characters If you are going to read bar codes of known length, it is recommended to set the reader for a fixed number of characters. This can be done for up to two lengths. The reader uses this to verify that labels read are of the correct length, rejecting any labels which do not have the specified length. The advantage of setting a fixed length, is that it provides protection against short scans of labels, such as Interleaved 2of5, which do not provide sufficient security against partial scan. The length checking is done on the label data and is not affected by options such as (not) transmit start/ stop character or check digit. Setting the number of characters does not affect fixed length codes, such as EAN-13. 2D symbologies such as PDF417 and Data Matrix are also not affected by fixed length settings.
Fixed length ON all codes. This option enables the fixed length checking. Two fixed lengths are programmed which will affect all variable length codes. This is done by reading the following labels: <SET> <Fixed length ON - all codes> a bar code with the required length, a second bar code with the required length (this may be the same length as the first one) <END> See figure 3.06.
Fig. 3.06. Setting Fixed length ON all codes SET Fixed length ON
The following options are available:
Scan a bar code with the required length
Fixed length OFF all codes. This option cancels the fixed length checking.
Scan a 2nd bar code with the required length END
U42
Page 50
OPTICON Universal menu book
Fixed length ON for selected codes: This option enables fixed length checking for different bar code types and will only affects the bar code types read. The number of fixed lengths which can be configured is reader dependent.
• if a label is checked for fixed length, it will not be checked for minimum or maximum length • if a label is not checked for fixed length it will be checked for both minimum and maximum length By reading an option followed by the 'END' label, the function is disabled or the values for that option are reset to their default. The default values are: • fixed: disabled, thus no fixed length checking • minimum: according to the next figure (The minimum length of the 2of5 bar code types can not be changed independent.) • maximum: disabled, thus no maximum length checking. (The maximum length is reader dependent) See figure 3.07.
<SET> <Fixed length ON for selected codes> Scan bar codes of the required type and length <END> Example: The 2 examples shown in the next figure have the following results: In the first example only Code 39 labels will be checked for a length of 6 characters. Any other bar code type will not be checked for fixed length. In the second example Code 39 labels will be checked for a length of 6 characters and Interleaved 2of5 labels for a length of 12 characters. This implies that also Industrial 2of5, Matrix 2of5 and S-Code are checked for a fixed length of 12 characters. Any other bar code type will not be checked for fixed length. See figure 3.08.
Fig. 3.07. Setting Minimum length table Code type:
Minimum length
Codabar
5
Code 11
1
Code 39
1
Code 93
1
Code 128
1
Industrial 2of5
5
Interleaved 2of5
6
IATA
5
Matrix 2of5
5
MSI/Plessey
3
UK/Plessey
2
GS1Databar-expanded
1
S-Code
5
Telepen
1
Fig. 3.08. Setting Fixed length ON selected codes SET
SET
Fixed length ON for selected only
Fixed length ON for selected only
Scan a label, i.e. Code 39 with length = 6
Scan a label, i.e. Code 39 with length = 6
END
Scan a label, i.e. Interleaved 2of5 with length = 12 END
U43
3 Code options
It is possible to configure a fixed length or a minimum and a maximum length for selected symbologies by reading the respective option followed by a barcode label with the required length. The different functions may be combined and will be used as follows: