Page 31

OPTICON Universal menu book

2.3.3. Trigger connection options Discoverable and connectable: When the trigger switch is pressed for the configured amount of time, the reader can either establish a connection, or wait for a new incoming connection. When it waits for a connection, the reader is also made discoverable.

Press trigger switch time to connect: This is the time the trigger switch needs to be pressed where after the reader tries to establish a connection.

SET

_ZZ_

Disabled

PC00

_PC00_

1 second

PC01

_PC01_

2 seconds

PC02

_PC02_

3 seconds

PC03

_PC03_

4 seconds

PC04

_PC04_

5 seconds

PC05

_PC05_

6 seconds

PC06

_PC06_

7 seconds

PC07

_PC07_

8 seconds

PC08

_PC08_

9 seconds

PC09

_PC09_

END

_ZZ_

U24

Page 32

OPTICON Universal menu book

_ZZ_

Trigger to connect

BBC

_BBC_

Trigger to make connectable and discoverable

BBD

_BBD_

END

_ZZ_

U25

2 Interface

SET

Page 33

OPTICON Universal menu book

2.3.4. Trigger disconnect options Press trigger switch time to disconnect: This is the time the trigger switch needs to be pressed where after the reader disconnects.

SET

_ZZ_

Disabled

PD00

_PD00_

1 second

PD01

_PD01_

2 seconds

PD02

_PD02_

3 seconds

PD03

_PD03_

4 seconds

PD04

_PD04_

5 seconds

PD05

_PD05_

6 seconds

PD06

_PD06_

7 seconds

PD07

_PD07_

8 seconds

PD08

_PD08_

9 seconds

PD09

_PD09_

END

_ZZ_

U26

Page 34

OPTICON Universal menu book

2.3.5. Auto disconnect options Auto disconnect: If the reader is idle for the configured time, it will disconnect. Purpose options are power saving.

_ZZ_

Disabled

AD00

_AD00_

10 minutes

AD01

_AD01_

20 minutes

AD02

_AD02_

30 minutes

AD03

_AD03_

40 minutes

AD04

_AD04_

50 minutes

AD05

_AD05_

60 minutes

AD06

_AD06_

END

_ZZ_

U27

2 Interface

SET

Page 35

OPTICON Universal menu book

2.3.6. Auto reconnect options time is expired, the reader stops trying. The reader will not reconnect after reading the manually disconnect label or after auto disconnection.

Auto reconnect: If the reader is disconnected because it is out of range or the Bluetooth device is not available, the reader will try to establish the connection during the configured time. If this

SET

_ZZ_

Disabled

CA00

_CA00_

1 minute

CA01

_CA01_

2 minutes

CA02

_CA02_

3 minutes

CA03

_CA03_

4 minutes

CA04

_CA04_

5 minutes

CA05

_CA05_

6 minutes

CA06

_CA06_

7 minutes

CA07

_CA07_

8 minutes

CA08

_CA08_

9 minutes

CA09

_CA09_

END

_ZZ_

U28

Page 36

OPTICON Universal menu book

2.3.7. Wireless power saving IEEE 802.15.4 power saving: IEEE 802.15.4 based readers change the antenna output power instead of changing the activity rate. See figure 2.08.

Activation levels: In order to reduce the power consumption it is possible to set the activity rate of the reader. The default setting is ‘Active’, meaning that the reader will continuously check for communication. By setting the level to a certain time the reader will reduce activity and check for communication only at the set time.

Fig. 2.08. Power saving table

Power level

-3 dBm -5 dBm -7 dBm -10 dBm -15 dBm -25 dBm

SET

_ZZ_

Level 0

LV00

_LV00_

Level 1 300 slots, 187.5ms

LV01

_LV01_

Level 2 500 slots, 312.5ms

LV02

_LV02_

Level 3 700 slots, 437.0ms

LV03

_LV03_

Level 4 900 slots, 562.5ms

LV04

_LV04_

Level 5 1100 slots, 687.5ms

LV05

_LV05_

Level 6 1300 slots, 812.5ms

LV06

_LV06_

Level 7 1500 slots, 937.5ms

LV07

_LV07_

END

_ZZ_ U29

2 Output power

Interface

Auto disconnect: Power consumption can also be reduced by auto disconnect settings as described in the chapters: Auto disconnect options and Auto reconnect options.

level 0 level 1 level 2 level 3 level 4 level 5

Page 37

OPTICON Universal menu book

2.3.8. Memorizing Clear all memorized data: All memorizing data is deleted and the storage area is cleared.

Memorizing options can be used to temporary store bar code data in case the bar code reader lost its connection. As soon the reader is connected again, the temporary stored data is transmitted to the computer and the storage area is cleared. The data is stored in RAM. In case the battery is depleted or battery is removed, data is lost.

Transmit memorized data: All memorized data will be transmitted, if a connection is available. Available memory for memorizing is reader dependent ( 12kB )

The bar code reader is automatically disconnected in case: • the bar code reader is out of range ( too far away from cradle ), • power from cradle is lost. Data memorizing disabled: Bar code data is not stored automatically, in case the connection is lost. Data memorizing can manually be started by reading the Start/ continue memorizing option. Data memorizing enabled: Bar code data is stored automatically, in case the connection is lost. Memorize after connection loss: Data is only temporary stored in case the bar code reader lost its connection. Memorizing stops in case the +-DISC-+ label is read or in case the wireless address is changed. Always memorize when not connected: Data is always temporary stored in case the bar code reader is not connected. Memorize control labels: The next options should be used without reading the SET and END label. These memorizing options are intended to manually control the memorizing mode. Start/continue memorizing: Manually start memorizing. In case memorized data was present, it will continue memorizing. Stop/pause memorizing: Manually stop memorizing. Memorizing can be continued by reading the Start/continue memorizing option.

U30

Page 38

OPTICON Universal menu book

2.3.8. Memorizing

_ZZ_

Data memorizing disabled

DTMD

_DTMD_

Data memorizing enabled

DTME

_DTME_

Memorize after connection loss

BM0

_BM0_

Always memorize when not connected

BM1

_BM1_

Memorize always (Batch mode)

BM2

_BM2_

END

_ZZ_

Clear all memorized data

+-MCLR-+

_+-MCLR-+_

Start/continue memorizing

+-MSTR-+

_+-MSTR-+_

Stop/pause memorizing

+-MSTP-+

_+-MSTP-+_

Transmit memorized data

+-MXMT-+

_+-MXMT-+_

2.3.8. Memorizing commands

U31

2 Interface

SET

Page 39

OPTICON Universal menu book

U32

Page 40

OPTICON Universal menu book

Note: The menubook categorizes the barcodes as groups of different symbologies with their translations and sometimes with relations to other family names. The next figure visualizes how code translations and relations are maintained in this Code options chapter. See figure 3.00.

3. CODE OPTIONS The menu options in this chapter are intended to adjust the decoding settings of the reader: • which bar code types can be read • the permissible length of the bar codes to be read • bar code specific options

Fig. 3.00. Code translations and relations Group UPC-A

EAN-13 and EAN-8

Code 39 and It.Pharm.

Codabar

2of5 and S-Code

IATA MSI/Plessey Telepen UK/Plessey Code 128 and GS1-128

Code 128 GS1-128

Relations

3 ISBN Bookland, ISSN, ISMN

NW7 NW7 ABC NW7 CX

Chinese Post

(EAN-128 / UCC-128)

Code 93 Code 11 Korean Postal Authority code Intelligent Mail Barcode POSTNET GS1 Databar

Composite Codes Codablock F DataMatrix Aztec

GS1 Databar GS1 Databar Limited GS1 Databar Expanded CC-A CC-B CC-C

Aztec Aztec Runes

Chinese Sensible code QR code Micro QR Code Maxi Code PDF417 MicroPDF417

U33

(RSS-14) (RSS Limited) (RSS Expanded)

Code options

UPC-E