The text of a manual · part 4 of 16
Universal menu book: bar code configuration and commands manual, pages 31 to 40
Pages 31 to 40 of 151
The original document is the PDF (662 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Opticon NFT-2100, Opticon NFT-7175 and Opticon OPT-6125
Page 31
OPTICON Universal menu book
2.3.3. Trigger connection options Discoverable and connectable: When the trigger switch is pressed for the configured amount of time, the reader can either establish a connection, or wait for a new incoming connection. When it waits for a connection, the reader is also made discoverable.
Press trigger switch time to connect: This is the time the trigger switch needs to be pressed where after the reader tries to establish a connection.
SET
_ZZ_
Disabled
PC00
_PC00_
1 second
PC01
_PC01_
2 seconds
PC02
_PC02_
3 seconds
PC03
_PC03_
4 seconds
PC04
_PC04_
5 seconds
PC05
_PC05_
6 seconds
PC06
_PC06_
7 seconds
PC07
_PC07_
8 seconds
PC08
_PC08_
9 seconds
PC09
_PC09_
END
_ZZ_
U24
Page 32
OPTICON Universal menu book
_ZZ_
Trigger to connect
BBC
_BBC_
Trigger to make connectable and discoverable
BBD
_BBD_
END
_ZZ_
U25
2 Interface
SET
Page 33
OPTICON Universal menu book
2.3.4. Trigger disconnect options Press trigger switch time to disconnect: This is the time the trigger switch needs to be pressed where after the reader disconnects.
SET
_ZZ_
Disabled
PD00
_PD00_
1 second
PD01
_PD01_
2 seconds
PD02
_PD02_
3 seconds
PD03
_PD03_
4 seconds
PD04
_PD04_
5 seconds
PD05
_PD05_
6 seconds
PD06
_PD06_
7 seconds
PD07
_PD07_
8 seconds
PD08
_PD08_
9 seconds
PD09
_PD09_
END
_ZZ_
U26
Page 34
OPTICON Universal menu book
2.3.5. Auto disconnect options Auto disconnect: If the reader is idle for the configured time, it will disconnect. Purpose options are power saving.
_ZZ_
Disabled
AD00
_AD00_
10 minutes
AD01
_AD01_
20 minutes
AD02
_AD02_
30 minutes
AD03
_AD03_
40 minutes
AD04
_AD04_
50 minutes
AD05
_AD05_
60 minutes
AD06
_AD06_
END
_ZZ_
U27
2 Interface
SET
Page 35
OPTICON Universal menu book
2.3.6. Auto reconnect options time is expired, the reader stops trying. The reader will not reconnect after reading the manually disconnect label or after auto disconnection.
Auto reconnect: If the reader is disconnected because it is out of range or the Bluetooth device is not available, the reader will try to establish the connection during the configured time. If this
SET
_ZZ_
Disabled
CA00
_CA00_
1 minute
CA01
_CA01_
2 minutes
CA02
_CA02_
3 minutes
CA03
_CA03_
4 minutes
CA04
_CA04_
5 minutes
CA05
_CA05_
6 minutes
CA06
_CA06_
7 minutes
CA07
_CA07_
8 minutes
CA08
_CA08_
9 minutes
CA09
_CA09_
END
_ZZ_
U28
Page 36
OPTICON Universal menu book
2.3.7. Wireless power saving IEEE 802.15.4 power saving: IEEE 802.15.4 based readers change the antenna output power instead of changing the activity rate. See figure 2.08.
Activation levels: In order to reduce the power consumption it is possible to set the activity rate of the reader. The default setting is ‘Active’, meaning that the reader will continuously check for communication. By setting the level to a certain time the reader will reduce activity and check for communication only at the set time.
Fig. 2.08. Power saving table
Power level
-3 dBm -5 dBm -7 dBm -10 dBm -15 dBm -25 dBm
SET
_ZZ_
Level 0
LV00
_LV00_
Level 1 300 slots, 187.5ms
LV01
_LV01_
Level 2 500 slots, 312.5ms
LV02
_LV02_
Level 3 700 slots, 437.0ms
LV03
_LV03_
Level 4 900 slots, 562.5ms
LV04
_LV04_
Level 5 1100 slots, 687.5ms
LV05
_LV05_
Level 6 1300 slots, 812.5ms
LV06
_LV06_
Level 7 1500 slots, 937.5ms
LV07
_LV07_
END
_ZZ_ U29
2 Output power
Interface
Auto disconnect: Power consumption can also be reduced by auto disconnect settings as described in the chapters: Auto disconnect options and Auto reconnect options.
level 0 level 1 level 2 level 3 level 4 level 5
Page 37
OPTICON Universal menu book
2.3.8. Memorizing Clear all memorized data: All memorizing data is deleted and the storage area is cleared.
Memorizing options can be used to temporary store bar code data in case the bar code reader lost its connection. As soon the reader is connected again, the temporary stored data is transmitted to the computer and the storage area is cleared. The data is stored in RAM. In case the battery is depleted or battery is removed, data is lost.
Transmit memorized data: All memorized data will be transmitted, if a connection is available. Available memory for memorizing is reader dependent ( 12kB )
The bar code reader is automatically disconnected in case: • the bar code reader is out of range ( too far away from cradle ), • power from cradle is lost. Data memorizing disabled: Bar code data is not stored automatically, in case the connection is lost. Data memorizing can manually be started by reading the Start/ continue memorizing option. Data memorizing enabled: Bar code data is stored automatically, in case the connection is lost. Memorize after connection loss: Data is only temporary stored in case the bar code reader lost its connection. Memorizing stops in case the +-DISC-+ label is read or in case the wireless address is changed. Always memorize when not connected: Data is always temporary stored in case the bar code reader is not connected. Memorize control labels: The next options should be used without reading the SET and END label. These memorizing options are intended to manually control the memorizing mode. Start/continue memorizing: Manually start memorizing. In case memorized data was present, it will continue memorizing. Stop/pause memorizing: Manually stop memorizing. Memorizing can be continued by reading the Start/continue memorizing option.
U30
Page 38
OPTICON Universal menu book
2.3.8. Memorizing
_ZZ_
Data memorizing disabled
DTMD
_DTMD_
Data memorizing enabled
DTME
_DTME_
Memorize after connection loss
BM0
_BM0_
Always memorize when not connected
BM1
_BM1_
Memorize always (Batch mode)
BM2
_BM2_
END
_ZZ_
Clear all memorized data
+-MCLR-+
_+-MCLR-+_
Start/continue memorizing
+-MSTR-+
_+-MSTR-+_
Stop/pause memorizing
+-MSTP-+
_+-MSTP-+_
Transmit memorized data
+-MXMT-+
_+-MXMT-+_
2.3.8. Memorizing commands
U31
2 Interface
SET
Page 39
OPTICON Universal menu book
U32
Page 40
OPTICON Universal menu book
Note: The menubook categorizes the barcodes as groups of different symbologies with their translations and sometimes with relations to other family names. The next figure visualizes how code translations and relations are maintained in this Code options chapter. See figure 3.00.
3. CODE OPTIONS The menu options in this chapter are intended to adjust the decoding settings of the reader: • which bar code types can be read • the permissible length of the bar codes to be read • bar code specific options
Fig. 3.00. Code translations and relations Group UPC-A
EAN-13 and EAN-8
Code 39 and It.Pharm.
Codabar
2of5 and S-Code
IATA MSI/Plessey Telepen UK/Plessey Code 128 and GS1-128
Code 128 GS1-128
Relations
3 ISBN Bookland, ISSN, ISMN
NW7 NW7 ABC NW7 CX
Chinese Post
(EAN-128 / UCC-128)
Code 93 Code 11 Korean Postal Authority code Intelligent Mail Barcode POSTNET GS1 Databar
Composite Codes Codablock F DataMatrix Aztec
GS1 Databar GS1 Databar Limited GS1 Databar Expanded CC-A CC-B CC-C
Aztec Aztec Runes
Chinese Sensible code QR code Micro QR Code Maxi Code PDF417 MicroPDF417
U33
(RSS-14) (RSS Limited) (RSS Expanded)
Code options
UPC-E
Symbology plus translations UPC-A UPC-A +2 UPC-A +5 UPC-E UPC-E +2 UPC-E +5 EAN-13 EAN-13 +2 EAN-13 +5 EAN-8 EAN-8 +2 EAN-8 +5 Code 39 Code 39 Full ASCII Tri-Optic Italian Pharmaceutical Codabar Codabar ABC Codabar CX Industrial 2of5 Interleaved 2of5 S-Code Matrix 2of5 Chinese Post Matrix 20f5