The text of a manual · part 3 of 16
Universal menu book: bar code configuration and commands manual, pages 21 to 30
Pages 21 to 30 of 151
The original document is the PDF (662 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Opticon NFT-2100, Opticon NFT-7175 and Opticon OPT-6125
Page 21
OPTICON Universal menu book
2.1.4. Intercharacter delay for RS232 The intercharacter delay introduces a configurable time delay after each character transmitted. This may be used if the connected computer or terminal does not support flow control and is not capable of handling the received data.
SET
_ZZ_
No delay
KA
_KA_
20 ms delay
KB
_KB_
50 ms delay
KC
_KC_
100 ms delay
KD
_KD_
END
_ZZ_
U14
Page 22
OPTICON Universal menu book
2.2. Keyboard wedge/USB options With keyboard: Use this mode in case a keyboard is connected to the PC wedge Y-cable. The wedge is only listening in case the computer is booting or when the wedge is idle.
This paragraph describes the options which are relevant to readers with a wedge or USB interface. The following parameters can be configured: • keyboard language • special options • intercharacter delay Because these options are interdependent, it is important to perform the configuration in the sequence given. Please consult your sales office for keyboard layouts and language currently supported. Keyboard wedge operation modes: This mode enables or disables responses from PC wedge to the computer during booting. In normal cases, the keyboard handles the responses to the computer. The PC wedge is only listening in order to be aware of the keyboard state.
The wedge is responding to all commands from the computer. The ‘without keyboard’ option is only supported for PC/AT wedges.
SET
_ZZ_
With keyboard
KM
_KM_
Without keyboard
KL
_KL_
END
_ZZ_
U15
2 Interface
Without keyboard: Use this mode in case no keyboard is connected to the PC wedge Y-cable. In some cases this mode is required in case only a PC USB keyboard is connected. If this option is enable, the computer can detect the wedge as a keyboard. In case the computer reports a keyboard error or in case no data is displayed, try this option. It is required to power OFF the PC, wait 10 seconds and power ON the PC again. Do not enable this option in case a keyboard is connected to the Y-cable.
Page 23
OPTICON Universal menu book
2.2.1. Keyboard language Keyboards are also different depending on country or language. Examples are the QWERTY and AZERTY keyboards. Select the same language that has been selected on your PC. The languages supported depend on the reader model and software release. Please consult your sales office for the languages currently supported.
SET
_ZZ_
US
KE
_KE_
UK
KV
_KV_
German
KG
_KG_
French
KI
_KI_
French Macintosh
BAO
_BAO_
Italian
OW
_OW_
Spanish
KJ
_KJ_
Portuguese
PH
_PH_
Swiss ( French )
PL
_PL_
END
_ZZ_
U16
Page 24
OPTICON Universal menu book
_ZZ_
Swiss ( German )
PK
_PK_
Dutch
PI
_PI_
Belgian
PJ
_PJ_
Swedish
PD
_PD_
Finnish
PG
_PG_
Danish
KK
_KK_
Norwegian
PE
_PE_
Japanese
PM
_PM_
Czech
WF
_WF_
END
_ZZ_
U17
2 Interface
SET
Page 25
OPTICON Universal menu book
2.2.2. Special options Auto NumLock mode: When selecting this option, the bar code reader automatically uses the correct NumLock state.
This section contains some specialised keyboard options.
No CAPSLOCK mode: This options cancels the CAPSLOCK mode.
Do not use numpad: The reader wil emulate the numerical keys on the alpha keypad when transmitting numerical data.
CAPSLOCK mode: This option ensures that data is displayed correctly when the keyboard is normally in CAPSLOCK mode. The keyboard is returned in the CAPSLOCK mode after transmission.
Use numpad: The reader will emulate the numerical keypad when transmitting numerical data. The NUMLOCK should always be ON when this option has been selected.
Auto CAPSLOCK mode: When selecting this option, the transmitted data is displayed correctly, disregarding the CAPSLOCK state.
SET
_ZZ_
Do not use numpad
RN
_RN_
Use numpad
RM
_RM_
Auto numlock mode
/A
_/A_
No CAPSLOCK mode
5Q
_5Q_
CAPSLOCK mode
8A
_8A_
Auto CAPSLOCK mode
2U
_2U_
END
_ZZ_
U18
Page 26
OPTICON Universal menu book
The intercharacter delay can be used to adapt the reader's data transmission speed to the system. If the transmission speed is too high, the system may not be able to receive all characters. Adjust the intercharacter delay until the data is received correctly. The default value as well as the actual delay time depend on the terminal type and language selected.
2.2.3. Intercharacter delay for wedges/USB
_ZZ_
No delay
LA
_LA_
Delay = 1
LB
_LB_
Delay = 2
LC
_LC_
Delay = 3
LD
_LD_
Delay = 4
LE
_LE_
Delay = 5
LF
_LF_
Delay = 6
LG
_LG_
Delay = 7
LH
_LH_
Delay = 8
LI
_LI_
Delay = 9
LJ
_LJ_
Delay = 10
LK
_LK_
END
_ZZ_ U19
2 Interface
SET
Page 27
OPTICON Universal menu book
2.3. Wireless options This section is intended to configure a wireless connection to an Opticon cradle and third party dongles. Options are available to minimize the reader’s power consumption and to maximize working time and enable secure data exchange.
Bluetooth dongle connection: In case a third party Bluetooth dongle is used, the Bluetooth address, pin code and security options needs to be configured manually. Consult your Bluetooth dongle manual how to obtain the Bluetooth address, how to configure
Default Bluetooth connection: By default the reader is configured to connect to the Opticon cradle. Simply read the twelve character Bluetooth address label on the bottom of the cradle. The reader automatically connects to the cradle and automatically configures the pin code, authentication and encryption.
the pin code and secure transmission. You need this information to configure the bar code reader. The Bluetooth dongle's driver installs a serial port on the computer, which is used by the bar code reader to transmit the data. Keyboard emulation: In case keyboard emulation is required, Opticon's program OpticonRL can convert the serial data from a COM port into keyboard data. Ask your local dealer or sales office how to obtain Tscan.
Default IEEE 802.15.4 connection: By default the reader is configured to connect to the Opticon cradle. Simply read the tencharacter address label on the bottom of the cradle. The reader automatically connects to the cradle and automatically configures the pin code, authentication and encryption. With IEEE 802.15.4, the connection only exists during data transfers. Therefor the options "Auto disconnect" and "Auto reconnect" are not supported.
Enable auto connect to Opticon cradle: After reading the address label on the cradle, the reader immediately tries to establish a connection. Disable auto connect to Opticon cradle: After reading the address label on the cradle, the reader needs to be connected manually.
RS232 cradle connection: In case the cradle is connected to the computer via RS232, the communication parameters such as baud rate, data bits, parity and stop bits can be configured via the bar code reader. For baud rate settings and for data, parity and stop bits refer to the applicable paragraphs as described earlier in this chapter.
Connect to other Bluetooth device: In order to connect to a different Bluetooth device scan the applicable menu labels in the following configuration order: • set Bluetooth device address (mandatory) • set Security (optional) • read label: Manually connect (mandatory) Bluetooth options: The reader can be configured for the options: • set connection (mandatory), choose from trigger connection or auto connection • select an address (mandatory) • select security method (optional) • set power savings (optional) • select memorizing options (optional)
USB cradle connection: In case the cradle is connected to the computer via USB, the USB driver for the cradle needs to be installed. This driver can be downloaded from www.opticon.com. The USB driver installs a serial port on the computer. Please consult your sales office for not listed platforms.
IEEE 802.15.4 options: The reader can be configured for the options: • set connection (mandatory) • set trigger connect options (optional) • set power savings (optional) • select memorizing options (optional) U20
Page 28
OPTICON Universal menu book
2.3.1. Bluetooth address Example for manually connection and configuration: Example Step 1. The following information is retrieved from the dongle's Bluetooth manager: Dongle make/type: MSI MS6967 Bluetooth Address: 00 04 12 34 AF 56 Secure Connection: Not Required.
To configure an Opticon Bluetooth bar code reader to connect to a third party Bluetooth dongle, the following steps must be taken: • step 1 - retrieve the dongle’s MAC address • step 2 - set the reader to connect directly to a computer • step 3 - set the MAC address of the dongle in the reader • step 4 - establish connection to the Bluetooth module
Example Step 2. • read the following codes: <SET> <Connect to PC> Example Step 3. Note: when reading the same menu label again, it is necessary to keep the reader away from the menu book for about one second. • from this chapter read: <Set bluetooth address label> • from the chapter Direct input numeric read: <0> keep reader away from menu book... <0> keep reader away from menu book... <0> <4> <1> <2> <3> <4> • from the chapter Direct input character read: <A> <F> • from the chapter Direct input numeric read: <5> <6> • from this chapter read: <End bluetooth address label> <END> Example Step 4. • read the command label: <Manually connect> Commands for (dis)connection: In case a Bluetooth address is already configured, the reader can be manually connected or disconnected with the following command labels: • connection: <Manually connect> • disconnection: <Manually disconnect>
U21
2 Interface
To enable the Bluetooth reader to communicate to another Bluetooth device, the Bluetooth address of that device must be configured in the reader. The Bluetooth address can be found on the other device. Mostly it is displayed on the product label as a 12 digits number or a number with 6 hex digit pairs.
Page 29
OPTICON Universal menu book
2.3.1. Bluetooth address
SET
_ZZ_
Set bluetooth address label
BDAS
_BDAS_
End bluetooth address label
BDAE
_BDAE_
Disable auto connect
DIAU
_DIAU_
Enable auto connect
ENAU
_ENAU_
Connect to PC
CNPC
_CNPC_
Connect to Cradle
CNCR
_CNCR_
Connect to Cradle (USBHID)
CNC2
_CNC2_
END
_ZZ_
2.3.1. Bluetooth address commands
Manually disconnect
+-DISC-+
_+-DISC-+_
Manually connect
+-CONN-+
_+-CONN-+_
Make discoverable and connectable
+-DSCO-+
_+-DSCO-+_
U22
Page 30
OPTICON Universal menu book
2.3.2. Bluetooth security
Use 'unsecured' connections If you want to use 'unsecured' connections: • scan disable authentication labels • disable authentication on the host
SET
_ZZ_
Set PIN-code label
PINS
_PINS_
End PIN-code label
PINE
_PINE_
Authentication if not paired
AUTO
_AUTO_
Disable authentication
AUTD
_AUTD_
Enable authentication
AUTE
_AUTE_
Disable encryption
ENCD
_ENCD_
Enable encryption
ENCE
_ENCE_
END
_ZZ_
U23
2 Interface
Use 'secured' connections If you want to use 'secured' connections: • scan enable authentication label • scan the PIN-code labels. The PIN-code is a code of 1 to 16 characters. Any personal combination alpha-numeric characters can be used. Read direct input (numeric) characters from the chapter: String options • enable authentication on the host • if encryption is required, scan enable encryption labels
To provide additional security connections, the Bluetooth specification allows you to enable a special security setting, so that a PIN-code is required from the bar code reader in order to establish a connection.