Page 21

OPTICON Universal menu book

2.1.4. Intercharacter delay for RS232 The intercharacter delay introduces a configurable time delay after each character transmitted. This may be used if the connected computer or terminal does not support flow control and is not capable of handling the received data.

SET

_ZZ_

No delay

KA

_KA_

20 ms delay

KB

_KB_

50 ms delay

KC

_KC_

100 ms delay

KD

_KD_

END

_ZZ_

U14

Page 22

OPTICON Universal menu book

2.2. Keyboard wedge/USB options With keyboard: Use this mode in case a keyboard is connected to the PC wedge Y-cable. The wedge is only listening in case the computer is booting or when the wedge is idle.

This paragraph describes the options which are relevant to readers with a wedge or USB interface. The following parameters can be configured: • keyboard language • special options • intercharacter delay Because these options are interdependent, it is important to perform the configuration in the sequence given. Please consult your sales office for keyboard layouts and language currently supported. Keyboard wedge operation modes: This mode enables or disables responses from PC wedge to the computer during booting. In normal cases, the keyboard handles the responses to the computer. The PC wedge is only listening in order to be aware of the keyboard state.

The wedge is responding to all commands from the computer. The ‘without keyboard’ option is only supported for PC/AT wedges.

SET

_ZZ_

With keyboard

KM

_KM_

Without keyboard

KL

_KL_

END

_ZZ_

U15

2 Interface

Without keyboard: Use this mode in case no keyboard is connected to the PC wedge Y-cable. In some cases this mode is required in case only a PC USB keyboard is connected. If this option is enable, the computer can detect the wedge as a keyboard. In case the computer reports a keyboard error or in case no data is displayed, try this option. It is required to power OFF the PC, wait 10 seconds and power ON the PC again. Do not enable this option in case a keyboard is connected to the Y-cable.

Page 23

OPTICON Universal menu book

2.2.1. Keyboard language Keyboards are also different depending on country or language. Examples are the QWERTY and AZERTY keyboards. Select the same language that has been selected on your PC. The languages supported depend on the reader model and software release. Please consult your sales office for the languages currently supported.

SET

_ZZ_

US

KE

_KE_

UK

KV

_KV_

German

KG

_KG_

French

KI

_KI_

French Macintosh

BAO

_BAO_

Italian

OW

_OW_

Spanish

KJ

_KJ_

Portuguese

PH

_PH_

Swiss ( French )

PL

_PL_

END

_ZZ_

U16

Page 24

OPTICON Universal menu book

_ZZ_

Swiss ( German )

PK

_PK_

Dutch

PI

_PI_

Belgian

PJ

_PJ_

Swedish

PD

_PD_

Finnish

PG

_PG_

Danish

KK

_KK_

Norwegian

PE

_PE_

Japanese

PM

_PM_

Czech

WF

_WF_

END

_ZZ_

U17

2 Interface

SET

Page 25

OPTICON Universal menu book

2.2.2. Special options Auto NumLock mode: When selecting this option, the bar code reader automatically uses the correct NumLock state.

This section contains some specialised keyboard options.

No CAPSLOCK mode: This options cancels the CAPSLOCK mode.

Do not use numpad: The reader wil emulate the numerical keys on the alpha keypad when transmitting numerical data.

CAPSLOCK mode: This option ensures that data is displayed correctly when the keyboard is normally in CAPSLOCK mode. The keyboard is returned in the CAPSLOCK mode after transmission.

Use numpad: The reader will emulate the numerical keypad when transmitting numerical data. The NUMLOCK should always be ON when this option has been selected.

Auto CAPSLOCK mode: When selecting this option, the transmitted data is displayed correctly, disregarding the CAPSLOCK state.

SET

_ZZ_

Do not use numpad

RN

_RN_

Use numpad

RM

_RM_

Auto numlock mode

/A

_/A_

No CAPSLOCK mode

5Q

_5Q_

CAPSLOCK mode

8A

_8A_

Auto CAPSLOCK mode

2U

_2U_

END

_ZZ_

U18

Page 26

OPTICON Universal menu book

The intercharacter delay can be used to adapt the reader's data transmission speed to the system. If the transmission speed is too high, the system may not be able to receive all characters. Adjust the intercharacter delay until the data is received correctly. The default value as well as the actual delay time depend on the terminal type and language selected.

2.2.3. Intercharacter delay for wedges/USB

_ZZ_

No delay

LA

_LA_

Delay = 1

LB

_LB_

Delay = 2

LC

_LC_

Delay = 3

LD

_LD_

Delay = 4

LE

_LE_

Delay = 5

LF

_LF_

Delay = 6

LG

_LG_

Delay = 7

LH

_LH_

Delay = 8

LI

_LI_

Delay = 9

LJ

_LJ_

Delay = 10

LK

_LK_

END

_ZZ_ U19

2 Interface

SET

Page 27

OPTICON Universal menu book

2.3. Wireless options This section is intended to configure a wireless connection to an Opticon cradle and third party dongles. Options are available to minimize the reader’s power consumption and to maximize working time and enable secure data exchange.

Bluetooth dongle connection: In case a third party Bluetooth dongle is used, the Bluetooth address, pin code and security options needs to be configured manually. Consult your Bluetooth dongle manual how to obtain the Bluetooth address, how to configure

Default Bluetooth connection: By default the reader is configured to connect to the Opticon cradle. Simply read the twelve character Bluetooth address label on the bottom of the cradle. The reader automatically connects to the cradle and automatically configures the pin code, authentication and encryption.

the pin code and secure transmission. You need this information to configure the bar code reader. The Bluetooth dongle's driver installs a serial port on the computer, which is used by the bar code reader to transmit the data. Keyboard emulation: In case keyboard emulation is required, Opticon's program OpticonRL can convert the serial data from a COM port into keyboard data. Ask your local dealer or sales office how to obtain Tscan.

Default IEEE 802.15.4 connection: By default the reader is configured to connect to the Opticon cradle. Simply read the tencharacter address label on the bottom of the cradle. The reader automatically connects to the cradle and automatically configures the pin code, authentication and encryption. With IEEE 802.15.4, the connection only exists during data transfers. Therefor the options "Auto disconnect" and "Auto reconnect" are not supported.

Enable auto connect to Opticon cradle: After reading the address label on the cradle, the reader immediately tries to establish a connection. Disable auto connect to Opticon cradle: After reading the address label on the cradle, the reader needs to be connected manually.

RS232 cradle connection: In case the cradle is connected to the computer via RS232, the communication parameters such as baud rate, data bits, parity and stop bits can be configured via the bar code reader. For baud rate settings and for data, parity and stop bits refer to the applicable paragraphs as described earlier in this chapter.

Connect to other Bluetooth device: In order to connect to a different Bluetooth device scan the applicable menu labels in the following configuration order: • set Bluetooth device address (mandatory) • set Security (optional) • read label: Manually connect (mandatory) Bluetooth options: The reader can be configured for the options: • set connection (mandatory), choose from trigger connection or auto connection • select an address (mandatory) • select security method (optional) • set power savings (optional) • select memorizing options (optional)

USB cradle connection: In case the cradle is connected to the computer via USB, the USB driver for the cradle needs to be installed. This driver can be downloaded from www.opticon.com. The USB driver installs a serial port on the computer. Please consult your sales office for not listed platforms.

IEEE 802.15.4 options: The reader can be configured for the options: • set connection (mandatory) • set trigger connect options (optional) • set power savings (optional) • select memorizing options (optional) U20

Page 28

OPTICON Universal menu book

2.3.1. Bluetooth address Example for manually connection and configuration: Example Step 1. The following information is retrieved from the dongle's Bluetooth manager: Dongle make/type: MSI MS6967 Bluetooth Address: 00 04 12 34 AF 56 Secure Connection: Not Required.

To configure an Opticon Bluetooth bar code reader to connect to a third party Bluetooth dongle, the following steps must be taken: • step 1 - retrieve the dongle’s MAC address • step 2 - set the reader to connect directly to a computer • step 3 - set the MAC address of the dongle in the reader • step 4 - establish connection to the Bluetooth module

Example Step 2. • read the following codes: <SET> <Connect to PC> Example Step 3. Note: when reading the same menu label again, it is necessary to keep the reader away from the menu book for about one second. • from this chapter read: <Set bluetooth address label> • from the chapter Direct input numeric read: <0> keep reader away from menu book... <0> keep reader away from menu book... <0> <4> <1> <2> <3> <4> • from the chapter Direct input character read: <A> <F> • from the chapter Direct input numeric read: <5> <6> • from this chapter read: <End bluetooth address label> <END> Example Step 4. • read the command label: <Manually connect> Commands for (dis)connection: In case a Bluetooth address is already configured, the reader can be manually connected or disconnected with the following command labels: • connection: <Manually connect> • disconnection: <Manually disconnect>

U21

2 Interface

To enable the Bluetooth reader to communicate to another Bluetooth device, the Bluetooth address of that device must be configured in the reader. The Bluetooth address can be found on the other device. Mostly it is displayed on the product label as a 12 digits number or a number with 6 hex digit pairs.

Page 29

OPTICON Universal menu book

2.3.1. Bluetooth address

SET

_ZZ_

Set bluetooth address label

BDAS

_BDAS_

End bluetooth address label

BDAE

_BDAE_

Disable auto connect

DIAU

_DIAU_

Enable auto connect

ENAU

_ENAU_

Connect to PC

CNPC

_CNPC_

Connect to Cradle

CNCR

_CNCR_

Connect to Cradle (USBHID)

CNC2

_CNC2_

END

_ZZ_

2.3.1. Bluetooth address commands

Manually disconnect

+-DISC-+

_+-DISC-+_

Manually connect

+-CONN-+

_+-CONN-+_

Make discoverable and connectable

+-DSCO-+

_+-DSCO-+_

U22

Page 30

OPTICON Universal menu book

2.3.2. Bluetooth security

Use 'unsecured' connections If you want to use 'unsecured' connections: • scan disable authentication labels • disable authentication on the host

SET

_ZZ_

Set PIN-code label

PINS

_PINS_

End PIN-code label

PINE

_PINE_

Authentication if not paired

AUTO

_AUTO_

Disable authentication

AUTD

_AUTD_

Enable authentication

AUTE

_AUTE_

Disable encryption

ENCD

_ENCD_

Enable encryption

ENCE

_ENCE_

END

_ZZ_

U23

2 Interface

Use 'secured' connections If you want to use 'secured' connections: • scan enable authentication label • scan the PIN-code labels. The PIN-code is a code of 1 to 16 characters. Any personal combination alpha-numeric characters can be used. Read direct input (numeric) characters from the chapter: String options • enable authentication on the host • if encryption is required, scan enable encryption labels

To provide additional security connections, the Bluetooth specification allows you to enable a special security setting, so that a PIN-code is required from the bar code reader in order to establish a connection.