Page 91

OPTICON Universal menu book

4.1. Case conversion The bar code data may be converted to either lower or upper case or the case may be exchanged. These options may be used if the user of a wedge has a preference to leave for instance the CAPSLOCK on or if the host requires upper case characters only. See figure 4.02.

Fig. 4.02. Case conversion

AbCd

Test string

AbCd

No case conversion

ABCD

Convert to upper case abcd

Convert to lower case aBcD

Exchange case

SET

_ZZ_

No case conversion

YZ

_YZ_

Convert to upper case

YW

_YW_

Convert to lower case

YX

_YX_

Exchange case

YY

_YY_

END

_ZZ_

U84

Page 92

OPTICON Universal menu book

4.2. Set prefix and suffix If the direct input keyboard key <return> from this chapter is selected then the result is a <carriage return> or <Enter> key. See figure 4.03.

A prefix and suffix of maximum 4 direct input entries each may be included in front and at the end of the string respectively. Bar code readers with an RS232 interface may be programmed with all 128 ASCII characters. Keyboard wedges may additionally be programmed with the special keys supported by the keyboard, e.g. function keys.

Fig. 4.03. Set prefix and suffix

Default settings are: • RS232: Prefix - None, Suffix - ^M (CR) • Wedge: Prefix - None, Suffix - return

SUFFIX

SET

SET

Set prefix Code 39

Set suffix Code 128

C

END

3 9

SET

:

Set suffix All

END

^M (CR) END

Preamble and postamble: A preamble is transmitted before the prefix and can contain up to 8 direct input characters. A postamble is transmitted after the suffix and can contain up to 8 direct input characters. A preamble and postamble will be transmitted for all symbologies. By default, the preamble and postamble is empty.

Bar code readers which do not support a different prefix or suffix for each symbology have to make use of <ALL>. How to clear a prefix or suffix: To clear the suffix for example for Code 128 scan the following labels: <SET> <Set suffix Code 128> <END>

Code identification Opticon: A code identification and the code length may be included as a prefix or suffix. The direct input 'code identifier' provides a quick method of programming in addition to programming a separate prefix or suffix for each bar code type. See figure 4.04.

How to set a suffix for all symbologies: To configure for example the suffix <CR> for all symbologies scan the following labels: <SET> <Set suffix ALL> <^M (CR)> <END>

Code identification AIM/ISO: The Code identifier will be transmitted in the ISO 15424 format : ]cm, where: • ] is ASCII value decimal 93 • c is code character • m is modifier character(s) For a detailed list of the modifier character 'm' and the AIM-ID’s, refer to the ISO15424 standard. See figure 4.05.

Note that this last example is for an RS232 interface. For a wedge interface a ^M (CR) results in the key combination <ctrl>M.

U85

4 String options

How to set a prefix or a suffix: To configure a prefix for example for Code-39 as C39: scan the following labels from this current chapter ‘String Options’: <SET> <Set prefix Code 39> <C> <3> <9> <:> <END>

PREFIX

Page 93

OPTICON Universal menu book

In case the modifier is an asterix (*), the value depends on the options of the symbology or on the configured Code options. For details refer to their own respective modifier tables. See figures 4.06 up to 4.17.

Fig. 4.04. Set prefix and suffix OPTICON Code identifiers

UPC-A UPC-A +2 UPC-A +5 UPC-E UPC-E +2 UPC-E +5 EAN-13 EAN-13 +2 EAN-13 +5 EAN-8 EAN-8 +2 EAN-8 +5 Code 39 Code 39 Full ASCII Italian Pharmaceutical Codabar Codabar ABC Codabar CX Industrial 2of5 Interleaved 2of5 S-Code Matrix 2of5 Chinese Post IATA MSI/Plessey Telepen UK/Plessey Code 128 GS1-128 Code 93 Code 11 Korean Postal Authority code Intelligent Mail Barcode POSTNET GS1 Databar CC-A CC-B CC-C Codablock F DataMatrix Aztec Aztec Runes Chinese Sensible code QR code Micro QR Code Maxi Code PDF417 MicroPDF417

Code length: The code length is transmitted as 2 digits, representing the decimal number of data characters transmitted, excluding prefix and suffix characters. For 2D bar codes the code length is transmitted as 6 digits. It is also possible to send for both 1D and 2D codes the length as 6 digits. These direct input characters count as 1 entry of the 4 permissible entries for a prefix or suffix. Example: If you want to configure the prefix <code identifier>:<code length>: scan the following labels: <SET> <Set prefix all> <Code identification> <:> <Code length> <:> <END> If you want to use the code identifiers, but need another code identifier for Code 39, you scan the following labels: <SET> <Set prefix all> <Code identification> <:> <Set prefix Code 39> <$> <:> <END>

U86

- C - F - G - D - H - I - B - L - M - A - J - K - V - W - Y - R - S - f - O - N - g - Q - w - P - Z - d - a - T - T - U - b - c - 0 (zero) - 3 - y - m - n - l - E - t - o - o - e - u - j - v - r - s

Page 94

OPTICON Universal menu book

Fig. 4.05. Set prefix and suffix

Fig. 4.06. Modifiers for Code 39 AIM/ISO15424 Code identifiers for :

AIM/ISO15424 Code identifiers

]AIM-ID *(Modifier table)

Symbology

Telepen UK/Plessey Code 128 GS1-128 Code 93 Code 11 Korean Postal Authority code Intelligent Mail Barcode POSTNET GS1 Databar CC-A (transmitted separately) CC-B (transmitted separately) CC-C (transmitted separately) GS1 Databar with CC-A GS1 Databar with CC-B GS1-128 with CC-C Codablock F Data Matrix Aztec QR Code Micro QR Code Maxicode PDF417 MicroPDF417

-

Normal Code 39 (D5) Not check CD (C1) Transmit CD (D9) Normal Code 39 (D5) Check CD (C0) Transmit CD (D9) Normal Code 39 (D5) Not check CD (C1) Not transmit CD (D8) Normal Code 39 (D5) Check CD (C0) Not transmit CD (D8) Full ASCII Code 39 (D4) or Full ASCII Code 39 if pos. (+K) Not check CD (C1) Transmit CD (D9) Full ASCII Code 39 (D4) or Full ASCII Code 39 if pos. (+K) Check CD (C0) Transmit CD (D9) Full ASCII Code 39 (D4) or Full ASCII Code 39 if pos. (+K) Not check CD (C1) Not transmit CD (D8) Full ASCII Code 39 (D4) or Full ASCII Code 39 if pos. (+K) Check CD (C0) Not transmit CD (D8)

]E0 ]E3 ]E3 ]E0 ]E3 ]E3 ]E0 ]E3 ]E3 ]E4 ]E7 ]E7 ]A* } (4.06) ]A* ]X0 ]X0 ]F* } (4.07) ]F* ]X0 ]S0 ]I* (4.08) ]X0 ]X0 ]X0 ]R* (4.09) ]M* (4.10) ]X0 ]B* (4.11) ]X0 ]C0 ]C1 ]G0 ]H* (4.12) ]X0 ]X0 ]X0 ]X0 ]e0 ]e1 ]e1 ]e1 ]e0 ]e0 ]e0 ]0* (4.13) ]d* (4.14) ]z* (4.15) ]X0 ]Q* (4.16) ]Q* ]U* (4.17) ]L0 ]L0

U87

A* ]AIM-ID ]A0

]A1

]A2

]A3

4

]A4

String options

UPC-A UPC-A +2 UPC-A +5 UPC-E UPC-E +2 UPC-E +5 EAN-13 EAN-13 +2 EAN-13 +5 EAN-8 EAN-8 +2 EAN-8 +5 Code 39 Code 39 Full ASCII Tri-Optic Code 39 It. Pharmaceutical Codabar Codabar ABC Codabar CX Industrial 2of5 Interleaved 2of5 S-Code Matrix 2of5 Chinese Post IATA MSI/Plessey

Code options

]A5

]A6

]A7

Page 95

OPTICON Universal menu book

Fig. 4.07. Modifiers for Codabar AIM/ISO15424 Code identifiers for :

Code options

Fig. 4.09. Modifiers for IATA

F* ]AIM-ID

Codabar normal mode (HA) Not check CD (H7) Transmit CD (H8) Codabar ABC (H3 or H4) Not check CD (H7) Transmit CD (H8) Codabar normal mode (HA) Check CD (H6) Transmit CD (H8) Codabar ABC (H3 or H4) Check CD (H6) Transmit CD (H8) Codabar normal mode (HA) Not check CD (H7) Not transmit CD (H9) Codabar ABC (H3 or H4) Not check CD (H7) Not transmit CD (H9) Codabar normal mode (HA) Check CD (H6) Not transmit CD (H9) Codabar ABC (H3 or H4) Check CD (H6) Not transmit CD (H9)

]F0

]F1

]F2

]F3

Code options

]AIM-ID

Not check CD (4H) Transmit CD (4L) Check FC and SN only (4I) or Check CPN,FC and SN (4J) or Check CPN,AC,FC and SN (4K) Transmit CD (4L) Not check CD (4H) Not transmit CD (4M) Check FC and SN only (4I) or Check CPN,FC and SN (4J) or Check CPN,AC,FC and SN (4K) Not transmit CD (4M)

]R0

AIM/ISO15424 Code identifiers for :

]F6

]AIM-ID ]M0 ]M1 ]X0

(4E) (4G) (4F)

Check 2 CD's = MOD 10/ MOD 10 (4C): (4C) (4E) or (4G) or (4F)

]X0

Check 2 CD's = MOD 10/ MOD 11 (4D): (4D) (4E) or (4G) or (4F)

]X0

Check 2 CD's = MOD 11/ MOD 10 (4R): (4R) (4E) or (4G) or (4F)

]X0

+

I*

M* / X0

Check 1 CD = MOD 10 (4B): (4B) Transmit CD1 Not transmit CD (4B) (4B) Transmit CD1 and CD2

+ + +

]F7

]AIM-ID Transmit CD (E0) Transmit CD (E0) Not transmit CD (E1) Not transmit CD (E1)

]R3

Code options Checksum + Transmit

+

Not check CD (G0) Check CD (G1) Not check CD (G0) Check CD (G1)

]R2

Fig. 4.10. Modifiers for MSI/Plessey

]F5

Fig. 4.08. Modifiers for Interleaved 2of5 Code options

]R1

]F4

+

AIM/ISO15424 Code identifiers for :

R*

AIM/ISO15424 Code identifiers for :

]I0 ]I1 ]I2 ]I3

Fig. 4.11. Modifiers for Telepen AIM/ISO15424 Code identifiers for :

B*

Code options

]AIM-ID

Telepen (numeric or ASCII only): ASCII mode (D3) Numeric mode (D2)

]B0 ]B1

Telepen (numeric followed by ASCII): ASCII mode (D3) Numeric mode (D2)

]B0 ]B2

Telepen (ASCII followed by numeric)(not supported): ASCII mode (D3) ]B0 Numeric mode (D2) ]B2

U88

Page 96

OPTICON Universal menu book

Fig. 4.12. Modifiers for Code 11 AIM/ISO15424 Code identifiers for :

Fig. 4.15. Modifiers for Aztec

H* / X0 ]AIM-ID

Check 1 CD (BLG) or Check auto 1 or 2 CDs (BLI) (length < 12) Transmit CD(s) (BLK) Check 2 CDs (BLH) or Check auto 1 or 2 CDs (BLI) (length > 12) Transmit CD(s) (BLK) Check 1 CD (BLG) or Check 2 CDs (BLH) or Check auto 1 or 2 CDs (BLI) (length > 12) Not transmit CD(s) (BLJ) Not check CD (BLF) Not transmit CD(s) (BLJ)

]H0

Data structure

]H1

]H3

]X0

O*

Data structure

]AIM-ID

FNC1 not used FNC1 in 1st position

]O4 ]O5

]AIM-ID ]z0 ]z1 ]z2 ]z3 ]z4

No structure / other FNC1 preceeding 1st message character FNC1 following an initial letter or pair of digits ECI protocol implemented FNC1 preceeding 1st message character and ECI protocol implemented FNC1 following an initial letter or pair of digits, ECI protocol implemented Structured append header included Structured append header included and FNC1 preceeding 1st message character Structured append header included, FNC1 following an initial letter or pair of digits Structured append header included and ECI protocol implemented Structured append header included, FNC1 preceeding 1st message character, ECI protocol implemented Structured append header included, FNC1 following an initial letter or pair of digits, ECI protocol implemented Aztec runes

Fig. 4.13. Modifiers for Codablock F AIM/ISO15424 Code identifiers for :

z*

]z5 ]z6 ]z7 ]z8 ]z9 ]zA

]zB

]zC

Fig. 4.16. Modifiers for QR Code AIM/ISO15424 Code identifiers for :

Fig. 4.14. Modifiers for DataMatrix AIM/ISO15424 Code identifiers for :

d*

Symbology, data structure

]AIM-ID

ECC000 - ECC140 ECC200 ECC200, FNC1 in 1st or 5th position ECC200, FNC1 in 2nd or 6th position ECC200, supporting ECI protocol ECC200, FNC1 in 1st or 5th position and supporting ECI protocol ECC200, FNC1 in 2nd or 6th position and supporting ECI protocol

]d0 ]d1 ]d2 ]d3 ]d4 ]d5

Q*

Model, data structure

]AIM-ID

Model 1 Model 2, ECI protocol not implemented Model 2, ECI protocol implemented Model 2, ECI protocol not implemented, FNC1 in first position Model 2, ECI protocol implemented, FNC1 in first position Model 2, ECI protocol not implemented, FNC1 in second position Model 2, ECI protocol implemented, FNC1 in second position

]Q0 ]Q1 ]Q2 ]Q3 ]Q4 ]Q5 ]Q6

]d6

Fig. 4.17. Modifiers for Maxicode AIM/ISO15424 Code identifiers for :

U89

U*

Data structure

]AIM-ID

Symbol in mode 4 or 5 Symbol in mode 2 or 3 Symbol in mode 4 or 5, ECI protocol implemented Symbol in mode 2 or 3, ECI protocol implemented

]U0 ]U1 ]U2 ]U3

4 String options

Code options

AIM/ISO15424 Code identifiers for :

Page 97

OPTICON Universal menu book

4.2.1. Set prefix

SET

_ZZ_

All Codes

RY

_RY_

UPC-A

N1

_N1_

UPC-A + add on

M0

_M0_

UPC-E

N2

_N2_

UPC-E + add on

M1

_M1_

EAN-13

N3

_N3_

EAN-13 + add on

M2

_M2_

EAN-8

N4

_N4_

EAN-8 + add on

M3

_M3_

Code 39

M4

_M4_

Codabar

M5

_M5_

Industrial 2of5

M6

_M6_

Interleaved 2of5

M7

_M7_

END

_ZZ_ U90

Page 98

OPTICON Universal menu book

_ZZ_

S-Code

MB

_MB_

Matrix 2of5

GL

_GL_

IATA

I8

_I8_

MSI/Plessey

N0

_N0_

Telepen

L8

_L8_

UK/Plessey

MA

_MA_

Code 128

M9

_M9_

Code 93

M8

_M8_

Code 11

BLD

_BLD_

Korean Postal Authority code

*$

_*$_

Intelligent Mail Barcode

D5I

_D5I_

POSTNET

D6D

_D6D_

GS1-Databar

OE

_OE_

END

_ZZ_

U91

4 String options

SET

Page 99

OPTICON Universal menu book

SET

_ZZ_

Composite codes

RR

_RR_

Codablock F

D4S

_D4S_

DataMatrix

MD

_MD_

Aztec

BF0

_BF0_

Chinese Sensible code

D4N

_D4N_

QR Code

MK

_MK_

Maxicode

ML

_ML_

PDF417

OC

_OC_

MicroPDF417

OD

_OD_

ISO track 1 (IATA)

MH

_MH_

ISO track 2 (ABA)

MI

_MI_

ISO track 3 (THRIFT)

MJ

_MJ_

Clear all prefixes

MG

_MG_

Preamble

MZ

_MZ_

END

_ZZ_ U92

Page 100

OPTICON Universal menu book

4.2.2. Set suffix

_ZZ_

All Codes

RZ

_RZ_

UPC-A

N6

_N6_

UPC-A + add on

O0

_O0_

UPC-E

N7

_N7_

UPC-E + add on

O1

_O1_

EAN-13

N8

_N8_

EAN-13 + add on

O2

_O2_

EAN-8

N9

_N9_

EAN-8 + add on

O3

_O3_

Code 39

O4

_O4_

Codabar

O5

_O5_

Industrial 2of5

O6

_O6_

Interleaved 2of5

O7

_O7_

END

_ZZ_ U93