Page 11

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Scanner/cable snap-in connector pin-out (connector: 3004CA8101 Kinsun) Pin No. 1 2 3 4 5 6 7 8 9 10

Signal RTS CTS TxD RxD VCC Ground NC NC NC NC

Environmental Specifications Temperature Operating Storage

+23 to +113° F (-5° to +45° C ) -4 to +140° F (-20° to +60° C)

Humidity (non- condensing) Operating 20 to 80% RH Storage 20 to 90% RH Ambient Light

Fluorescent or incandescent: below 3 kilolux

Ordering Information Part No. LPN1137RR1S-050

Model Front View, 9 Pin D-Sub Female Connector (with power stereo jack)

(standard configuration, other configurations are available upon request)

Developer’s Test and Evaluation Kit (LPN-1137R1-SK1) is available which contains all the items needed to install and evaluate the scanner. The kit includes: Scanner 5V Power Supply (32-00907-01) User Manual CD ROM (including manual, datasheet and supporting materials)

Page 7

Page 12

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Section 3 Positioning the Scanner for Optimum Performance Achieving Optimum Performance Three items greatly impact performance: 1) Distance (from the scan window) to the bar code 2) Specular Reflection 3) Quality of Bar Code Labels 1) Distance to the Bar Code The ideal location of the bar code relative to the scanner is in the waist of the laser beam. A bar code located either too near or too far from the scanner relative to the waist may cause the scanner to have difficulty decoding what appears to be fuzzy bars and spaces. For the LMD 1135 fixed position scanner, the waist is approximately 2.5” from the front edge of the scanner Depth-of-Field Just as with a camera, the scanner has a depth-of-field. It can read bar codes that are not precisely at the laser beam waist - maybe a little closer, or a little farther away. However, if the bar code label is positioned too far from the waist of the beam, the scanner may not be able to successfully decode it. The depth-of-field varies based on the density of the bar code, i.e., the thickness of the bars. Very high density bar codes (which have very narrow bars) are readable over a much shorter distance range than low density bar codes with larger bars. The following table shows the depth-of-field “specifications” (closest to farthest reading distances) for the LMD 1135 scanner. The actual performance may differ slightly from unit to unit. Also, it is important to note that this data was measured under ideal conditions using high quality bar code labels. In a “real world” environment the conditions will not be as ideal. Therefore, the best practice is to position the scanner at the center of the depth-of-field rather than at the extremes of its depth-of-field. Data taken for a “typical” unit randomly drawn from stock is presented in Appendix E. Depth-of Field LMD 1135 (Specification)* Near Bar Code Density Distance 40 mil (1.00 mm) 4.3” 20 mil (0.50 mm) 3.1” 10 mil (0.25 mm) 2.4” 6 mil (0.15 mm) 1.8” 5 mil (0.127 mm) 2.2” * measured from front edge of scanner

Far Distance 14.2” 9.8” 5.7” 3.1” 2.8”

Page 8

Page 13

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Readable Bar Code Width LMD 1135 (Field-of-View Specification Based Upon 40 Degree Sweep) Distance from Window 2.0” 4.0” 8.0” 12.0”

Max. Width 2.8” 4.2” 7.2” 10”

The table above shows the field-of-view at various distances from the window. The field-of-view is the maximum width that the scanner is capable of reading. It is the distance from the left edge of the view to the right edge. A bar code label positioned anywhere within this field-of-view can be decoded. The field-of-view is also a measure of the widest bar code label that can be read. Remember: The width of a bar code label includes not only the bars and spaces but also the required white space (quiet zone) on each end. Good design policy is to position the barcode at the midpoint of the scanner’s depth-of-field and at the center of the field-of-view. Do not position it near the extremes of the reading range.

2) Avoiding Specular Reflection Do not position the scanner at an angle that causes the laser light to be reflected directly back into the scanner. This is called specular reflection. Too much reflected light can “blind” the scanner preventing a good decode. The recommended location is + 13 degrees off the perpendicular for optimal performance. If the bar code label is located on a flat surface, specular reflectivity occurs between 0 to 8 degrees off perpendicular. (See diagram) If the bar code label is located on a cylindrical surface, such as a test tube, the angle of specular reflection is measured tangent to the curve. If the curved surface is also moving, there may be more than one position causing specular reflection. The following diagram indicates the area to avoid:

Page 9

Page 14

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

3) Quality Bar Code Labels The quality of the bar code label can affect the scanning performance. Poor quality labels are more difficult to decode and may result in non-reads or potential misreads. The bar code label should be printed to specifications. This means that the bars are printed within spec, with the correct widths, no ink spread, crisps edges and no voids. There should be a sufficient quiet zone on both end of the bar code label. For best results, the paper or label stock should have a matte finish to diffuse light. The print contrast signal (which is a comparison of the reflectance of the bars and the background stock) should be as high as practical.

Measuring Scanner Performance A method for properly positioning the unit is to program the scanner for Trigger Disable (S7) and Continuous Read (S2) modes. The scanner will be always on and will continuously read the same bar code. Since the buzzer sounds each time the bar code is read, the sound of the buzzer can be used like a “Geiger counter”. As the position of the scanner changes the sound of the buzzer will change. The buzzer sound will be loudest and most continuous at the best reading position.

Page 10

Page 15

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Application Notes Tips for Achieving High Throughput In some applications your primary objective may be to achieve the highest possible throughput rate. The following list identifies the parameters and scanner settings that can maximize scanning and decode throughput speed. Note, by emphasizing maximum throughput, other areas of performance may be affected. For example, the number of non-reads could increase. If high throughput is critical, consider some or all of these settings: ♦

Operate in the Trigger Disabled mode. Operation of the trigger creates delay before decoding begins, slowing down throughput rate.

♦

Only enable those symbologies that you will be decoding.

♦

Eliminate all suffixes and prefixes to reduce transmission time.

♦

Minimize the number of redundant reads required before transmitting data.

♦

Transmit the decoded data at the highest baud rate.

♦

Disable buzzer functions.

Tips for Insuring Highest Data Integrity There are several parameters that can enhance your confidence that the correct bar code data is transmitted. Note that by emphasizing the accuracy and security of the data other areas of the scanner operation may be affected, for example, you may not achieve the highest throughput. If accuracy and data integrity are critical, consider some or all of these settings: ♦

Program the scanner to require a high number of redundant decodes prior to transmitting. For example, program the scanner to decode a bar code exactly the same way three consecutive times before transmitting the data. Then decoding the bar code the same way 2 out of 3 times or any 3 out of 4 times is not sufficient. It must obtain three consecutive, identical decodes.

♦

Utilize a predetermined, fixed-length of bar code. Program the scanner to only decode a bar code of that length. Bar codes of any other length will be ignored.

♦

The quality of the printed bar code must be excellent.

♦

Use a bar code symbology that contains an internal check digit and program the scanner to calculate that check digit for validity prior to transmitting.

♦

Do not use a symbology with poor internal verification, or subject to partial decodes, such as 2 of 5 or MSI/Plessey.

♦

Only enable those symbologies that you will be decoding.

♦

Transmit data at low baud rates to minimize communication errors.

♦

Enable the “Number of Characters Transmitted”. The scanner will calculate and transmit a number indicating the total number of characters it is transmitting. Your host application program can compare this number with the actual number of characters received to verify that the correct amount of data is received. Page 11

Page 16

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Tips for Verifying the Presence of a Bar Code If the scanner is operated in the “trigger enabled” mode and the trigger is activated, one of three conditions may occur: A bar code is scanned and decoded. A bar code is scanned but is not decoded (e.g., print quality was poor) No bar code is present

Decoded data is transmitted No data is transmitted No data is transmitted

In some applications, when no data is transmitted, it may be important to know why. Was there a bar code present that could not be decoded, or was no bar code present at all? This requirement is common in applications such as automated blood analysis equipment. Test tubes containing blood samples from many different people are loaded into a rack for automatic analysis. The bar code on each tube ties that sample and the results back to a specific individual. If no bar code data is transmitted it is critical to understand the reason. Your Opticon scanner, when operated in the Trigger Enabled mode, can be programmed to transmit an error message indicating whether or not a bar code was present. See Section 33 of Appendix C of this manual for details.

Page 12

Page 17

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Section 4 Configuring the Scanner Since the operation of the LMD 1135 scanners are microprocessor controlled, it is possible to modify or program its operation to match your specific application. Changes in parameter settings can be accomplished two ways. 1. The scanner can be programmed by sending software instructions from the host PC to the scanner via the RS232 connection. 2. The second method employs specially designed programming bar codes. Scanning these bar codes instructs the scanner to modify specific parameters.

Programming Menus & Commands Appendix A contains full instructions on how to configure the scanner as well as a complete listing of the computer commands and programming bar codes that are available to customize the scanner for your application.

Default Settings When you modify or change any parameters, the scanner can be programmed to retain the new parameter in memory, even if power interrupted or terminated. If for any reason the scanner is instructed to return all parameters to default settings (U2), it will return to the default settings shown in the following table.

%) throughout the bar codes menus.

Default settings are indicated by a pointing hand symbol ( Parameter RS 232 Communications

Trigger Function Auto-Trigger Function Read Mode No. of Redundant Decodes UPC-A (12 digits) UPC-E (7 digits) Code 39 Codabar 2 of 5 (Interleaved and Industrial) Fixed length of bar code only Buzzer Positive bar codes only Error indications

Factory Default Setting 9600 baud 8 data bits 1 stop bit No parity No handshaking Enabled Enabled Multiple Read Mode Read three times before transmitting No leading zero Enable check digit No leading zero Enable check digit Do not calculate check digit/Transmit check digit Disable start/stop characters (*.....*) Disable start/stop characters Do not calculate check digit Do not calculate check digit Disabled Enabled Enabled Do not transmit error code

Page 13

Page 18

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Section 5 Application Engineering Support Technical Assistance and Support Opticon is eager to help you integrate the LMD 1135 scanner into your application. Our technical support staff is available to answer any questions or work with you to adapt the scanner to your specific situation. We are happy to answer your questions, assist in configuring and positioning the scanner for optimum operation, and help resolve any problems you encounter. Call us at 1 (800) 636-0090.

Common Causes of Poor Performance The most common reasons for poor scanning performance are listed below: ♦

Bar codes are not positioned at the focal distance of the scanner.

♦

Specular reflection is impacting the scanner. Change the angle/position of the scanner or the bar code.

♦

Poor quality of printed bar codes. Bar codes are out of specification.

♦

The paper on which the bar code is printed is highly reflective or has a glossy finish causing light to be reflected into the scanner.

♦

The distance from the scanner to the bar code is not suitable for the density of the bar code. Or the density of the bar code beyond the scanners capability. If the red illuminating light of the scanner is not on, the scanner may be in the “Trigger Enable” mode expecting a trigger signal.

Modified and/or Customized Scanners Opticon will work with you to modify or customize scanners to match your requirements. Scanners can be modified in terms of connectors type, pin-outs, cable length, default settings, custom software and many other areas. Opticon will modify scanners in our factory and ship you scanners that match your specific requirements. By incorporating your modifications directly into production scanners, you receive scanners tailored for your need. They can be used immediately without the need for further modification or rework.

Page 14

Page 19

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Section 6 Scanner Labeling IEC 825-1 Class 1 Laser Device

The LMD 1135 has been examined and found to be a Class 1 Laser Device according to the relevant requirements of IEC 825-1 and corresponding EN 60825-1 (1993-11) including amendment 1 (1997-09) and amendment 2 (2001-01). This scanner also complies with Center for Devices and Radiological Health (CDRH) 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50 dated July 26, 2001. The LMD 1135 scanner use a low-power visible laser. As with any very bright light source, such as the sun, you should avoid staring into the light beam. Momentary exposure to an IEC 825-1 Class 1 laser is not known to be harmful. A manufacturer’s label, as shown below, indicating the manufacturer, product model, ordering number, serial number, laser class, CE mark and place of manufacture is affixed to each scanner.

Section 7 Scanner Servicing and Maintenance CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. The LMD 1135 scanner contains no user adjustable or serviceable parts in the interior of the scanner. All product service must be performed by the Opticon Service Department in Orangeburg, NY. Opening the scanner will void the warranty and could expose the operator to laser light. The LMD 1135 is warranted for 1 year including parts and workmanship. If you need warranty or out-ofwarranty repair, first call 1-800-636-0090 to obtain a Returned Material Authorization (RMA) number. You will be provided a number and shipping instructions. There is no scheduled maintenance required for the LMD 1135. The scanner can be cleaned using a water dampened, lint free or lens cloth. Be careful to avoid excessive moisture that would penetrate the housing or obscure the window. While use of cleaning fluids other than water are not recommended, a neutral detergent or ethanol would be preferred if necessary. Do not use bleach at full or diluted strength as damage to the painted case and/or window may result. Page 15

Page 20

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Appendices

Appendix A

How to Program the Scanner

Appendix B

Computer Programming Commands

Appendix C

Bar Code Programming Commands

Appendix D

Dimensional Drawing

Appendix E

Optical Performance (typical)