Page 21

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Appendix A Programming the Scanner Two different methods can be used to program parameters to configure the scanner: a. Programming via Computer Commands b. Programming via special Bar Codes from a menu page Most parameters can be programmed using either of these two methods. However, there are certain parameters that are only programmable via the bar code menu.

a. Programming via Computer Commands Parameters can be programmed by sending software commands or keyboard strokes from the host computer to the scanner in the following format: <ESC> Computer Command <CR> Note:

Only upper case letters are recognized, e.g., “AB” not” ab” Each command normally consists of two characters Downloading of software commands cannot be “grouped” together. Each command must be preceded by <ESC> and followed by a <CR>

Parameters programmed by downloaded commands can be stored permanently by transmitting a “<ESC> Z2 <CR>” command. It is not necessary to send a “Z2” command after each parameter is changed. One Z2 command will save all changes Appendix B lists all of the Computer Commands. In Appendix C, Bar Code Programming Menus, the lefthand column in all menus contains the Computer Command associated with that bar code.

b. Programming via Bar Codes Use the following steps to program parameters via the bar code menus: 1. Scan the “Start/End” bar code. This instructs the scanner to enter the Programming Mode. While in this mode the scanner will beep intermittently. 2. Scan the bar code(s) associated with the desired parameter(s). The scanner will beep when the bar code is read. Note: because of the close proximity of bar codes on the page, it is important to aim carefully to ensure that only the desired bar code is scanned. 3. Scan the “Start/End” bar code. This instructs the scanner to exit the Programming Mode.

All the parameters that were scanned are retained in memory and are stored permanently (even if the scanners is power down) or until they are changed again. Page 17

Page 22

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

When the scanner is in the Programming Mode, you can change more than one parameter at a time. However, this may become confusing. Until you become proficient at programming you may prefer to change only a few parameters at one time. We recommend that you keep a record of the changes you have made to the scanner.

What if you make a mistake? Don’t worry. If you are programming the scanner but are unsure of which parameters have been changed, scan the Reset All Defaults bar code. This bar code returns the scanner to the default settings that were installed in the factory at the time the product was manufactured. Scanning this bar code erases any change you have made, including any changes that were made during previous programming. Reset All Defaults U2 Command (U2) This command will also return all settings to the defaults that were installed in the factory

Page 18

Page 23

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Appendix B Computer Programming Commands All commands must be preceded by an 'ESC' character (ZZ) and be followed by a 'Carriage Return' character (1C). Shaded areas indicate factory default settings.

Enable

Global Defaults

JD

JZ

TriOptic

U2

Enable Factory Default Settings

RA

R9

SCode

Z1

Transmit software version

Enable

Z2

Save all values set by command

E2

Z3

Display software settings (inc, prefix/suffix).

UPC-A (13 Digits) Transmit leading zero & CD

E3

UPC-A (12 Digits) No leading zero but transmit CD

E4

UPC-A (12 Digits)Transmit leading zero but No CD

E5

UPC-A (11 Digits) No leading zero & no CD transmitted

E6

UPC-E (8 Digits)Transmit leading zero & CD

E7

UPC-E (7 Digits) No leading zero but transmit CD

E8

UPC-E (7 Digits) Transmit leading zero but no CD

E9

UPC-E (6 Digits) No leading zero & no CD transmitted

6Q

Transmit UPC-E as is

6P

Transmit UPC-E as UPC-A

Only

Disable

Add

Symbology Selection

A0

Enable all symbologies

B0

Disable all symbologies

J0

Enable all UPC and EAN

A2

B2

Code 39

A3

B3

Codabar (NW-7)

A4

B4

IATA

A5

B5

Code 93

A6

B6

Code 128 (Inc. EAN-128)

A7

B7

MSI/Plessey

A9

B9

Telepen

J1

R1

UPC (A/E)

J2

R2

UPC (A/E)+2

J3

R3

UPC (A/E)+5

J4

R4

EAN (13/8)

J5

R5

EAN (13/8) +2

J6

R6

EAN (13/8) +5

J7

R7

2 or 5 Industrial

J8

R8

2 or 5 Interleaved

Disable

Options for UPC

Enable

Disable

Options for EAN-8 & EAN-13

6K

6J

EAN-13 Transmit CD

6I

6H

EAN-8 Transmit CD

IA

IB

Enable ISBN translation

HO

HN

Enable ISSN translation

Page 19

Page 24

Manual No. 25-ULPNR102-01; Mar, 2005

Enable

Disable

LMD 1135 Laser Fixed Mount Scanner

Options for Code 39

Enable

Disable

Options for 2 of 5 / SCode

8E

Enable 1 character read

G1

G0

Calculate check digit

8D

Enable 3 character read

E0

E1

Transmit check digit

C0

C1

Enable Check Digit calculation

GE

Enable 1 character minimum

D9

D8*

Transmit Check Digit

GF

Enable 3 characters minimum

D0

D1

Transmit start/stop characters (*…..*)

GI

Enable 5 characters minimum

+L

+M

Concatenation

-Y

-Z

Alternative algorithm

*Only disable if C0 enabled, otherwise truncate last digit.

Enable

Disable

D6 DB

Enable

Options for IT Pharmaceutical

GG

GH

Transmit S-Code as Interleaved 2 of 5

-Y

-X

Alternative Algorithm

Enable

Disable

Options for IATA

4H

Do not calculate check digit

4J

Calculate CD (CPN + Form + Serial)

4I

Calculate CD (Form + Serial)

4K

Calculate check digit (all data)

IT Pharmaceutical only DA

Disable

Transmit Leading A

Options for Codabar (NW-7)

HC

Enable 1 character read minimum

HB

Enable 3 character read minimum

HF

Enable 5 character read minimum

F0

Do not transmit start/stop characters

F1

Transmit start/stop as ABCD/TN*E

F2

Transmit start/stop as abcd/tn*e

F3

Transmit start/stop as ABCD/ABCD

F4

Transmit start/stop as abcd/abcd

H8

H9

Transmit check digit

H6

H7

Calculate check digit

HH

HI

Intercharacter gap check

-Y

-X

Alternative Algorithm

4L

4M

Transmit check digit

-Y

-X

Alternative Algorithm

Enable

Disable

JF

OF

EAN-128 Only

MO

MP

Concatenation

Enable

Disable

+V

+W

Options Code 128/EAN 128

Options for Code 93 Concatenation

Fixed Number of Digits H1

Fixation on all symbologies

HK

Fixation on selected symbologies

HL

Minimum length selected symbologies

HM

Maximum length selected symbologies

H0

Disable fixation on all symbologies

Page 20

Page 25

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Prefix/Suffix of Control Characters Prefix

Suffix

Select Symbology for Prefix/Suffix

1B

STX

RY

RZ

All codes

1C

ETX

N1

N6

UPC-A

1M

Carriage Return

M0

O0

UPC-A +2 or +5

1J

Line Feed

N2

N7

UPC-E

M1

O1

UPC-E +2 or +5

N3

N8

EAN13

M2

O2

EAN-13 +2 or +5

N4

N9

EAN-8

M3

O3

EAN-8 +2or +5

M4

O4

Code 39

M5

O5

Codabar (NW-7)

M6

O6

Industrial 2 of 5

M7

O7

Interleaved 2 of 5

K0

150 baud

M8

O8

Code 93

K1

300 baud

M9

O9

Code 128

K2

600 baud

I8

I9

IATA

K3

1,200 baud

N0

N5

MSI/Plessey

K4

2,400 baud

MB

OB

SCode

K5

4,800 baud

L8

L9

Telepen

K6

9,600 baud

K7

19,200 baud

K8

38,400 baud

L0

7 Data Bits

L1

8 Data Bits

L2

Parity = None

L3

Parity = Even

L4

Parity = Odd

L5

1 Stop bit

L6

2 Stop bits

Prefix/Suffix of Numeric Characters

Q0

0 thru thru

Q9

9 Prefix/Suffix of Alpha Characters

0A

A thru thru

0Z

Z

Code ID & Character Length Transmission $2

Code identification

$3

Code length 2 digits

$6

Code length 6 digits

Communications Parameters

Page 21

Page 26

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Handshaking

Positive & Negative Bar Codes

I0

Unlimited wait for CTS from terminal

V2

Positive bar codes only

I1

100 mS wait for CTS from terminal

V3

Only negative bar codes

I2

200 ms wait for CTS from terminal

V4

Both positive and negative bar codes

I3

400 mS wait for CTS from terminal

P0

No Handshaking

P1

Busy/Ready

P2

Modem

P3

ACK/NAK (1 second timeout with error buzzer)

P4

ACK/NAK no response (100 ms timeout, terminates with good read buzzer)

ZG

XON/OFF

KA

No intercharacter delay

KB

20 ms intercharacter delay

KC

50 ms intercharacter delay

KD

100 ms intercharacter delay

Buzzer Operation

Setting the Trigger & Auto-Trigger Functions S7

Disable the trigger function (Laser On)

S8

Enable the trigger function (Laser OFF until the trigger is activated )

+F

Auto-Trigger Disable

+I

Auto-Trigger Enable

Z

Activate the trigger; turns the laser ON

Selecting the Read Mode S0

Single Read Mode (Trigger must be Enabled, S8)

S1

Multiple Read Mode

S2

Continuous Read Mode

T0

Volume = Maximum

T1

Volume = Upper mid-range

T2

Volume = Lower mid-range

+6

2 Parallel labels only

T3

Volume = Minimum

+7

3 Parallel labels only

W0

Disable Buzzer

+8

4 Parallel labels only

W1

Enable buzzer at 3kHz

W2

Enable buzzer at 3kHz with 2.5kHz interval

W3

Enable buzzer at 3kHz with 4kHz interval

W4

Buzzer duration 0.10 sec

W5

Buzzer duration 0.20 sec

W6

Buzzer duration 0.40 sec

W7

Buzzer duration 0.05 sec

W8

Enable buzzer

Parallel Read Mode

Page 22

Page 27

Manual No. 25-ULPNR102-01; Mar, 2005

Scanner Timeout (Trigger Enabled Mode) Y1

1 second after triggering

Y2

2 second after triggering

Y3

3 second after triggering

Y4

4 second after triggering

Y5

5 seconds after triggering

Y6

6 second after triggering

Y7

7 seconds after triggering

Y8

8 seconds after triggering

Y9

9 seconds after triggering

YL

Read time x 10

YM

Indefinitely after triggering

XA

Add-on Wait Time - Disable

XB

Add-on Wait Time – 250 msec

XC

Add-on Wait Time – 500 msec

XD

Add-on Wait Time – 750 msec

LMD 1135 Laser Fixed Mount Scanner

YR

Margin check 4/7 nominal

YS

Margin check 5/7 nominal

YT

Margin check 6/7 nominal

YU

Margin check normal

Redundant Decoding X0

Read bar code once

X1

Read bar code twice before transmitting

X2

Read bar code three times before transmitting

X3

Read bar code four times before transmitting

BS

Read bar code five times before transmitting

BT

Read bar code six times before transmitting

BU

Read bar code seven times before xmitting

BV

Read bar code eight times before xmitting

BW

Read bar code nine times before xmitting

Xmit Error (Trigger Enabled Mode only) TH

User defined error message for no label

TI

User defined error message for no decode

TG

Clear error messages for no label, no decode

WD

Response to command - None

WC

Response to command – OK=ACK, ERROR=NAK

AH

Multiple Read Reset Time – 50 msec

AI

Multiple Read Reset Time – 100 msec

AJ

Multiple Read Reset Time – 200 msec

AK

Multiple Read Reset Time – 300 msec

AL

Multiple Read Reset Time – 400 msec

AM

Multiple Read Reset Time – 500 msec

AN

Multiple Read Reset Time – 600 msec

WB

Buzzer Control to Command - Disable

AG

Multiple Read Reset Time - Indefinite

WA

Buzzer Control to Command - Enable

Quiet Zone Options

Good Read LED Operation

YN

No margin check

T4

Disable good read LED (GRL)

YO

Margin check 1/7 nominal

T5

GRL ON for 0.20 seconds after decode

YP

Margin check 2/7 nominal

T6

GRL ON for 0.40 seconds after decode

YQ

Margin check 3/7 nominal

T7

GRL ON for 0.80 seconds after decode

Page 23

Page 28

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Appendix C: Bar Code Programming Menus & Commands - Index 1. Global Default & Scanner Configurations....................................... 25 2. Symbology Selection ................................................................... 26 3. Add/Activate Specific Bar Code Symbologies ................................. 28 4. Delete/Deactivate Specific Bar Code Symbologies.......................... 29 5. Options for UPC.......................................................................... 30 6. Options for EAN-8 & EAN-13……………………………………………………….31 7. Options for Code-39 & IT Pharmaceutical) .................................... 32 8. Options for Codabar (NW-7) ........................................................ 34 9. Options for 2 of 5 (Including SCode) ............................................ 36 10. Options for IATA....................................................................... 37 11. Options for Code-128 & EAN-128……………………………………………….38 12. Options for Code-93………………………………………………………………….38 13. Fixing the Number of Digits ........................................................ 39 14. Creating a Prefix and/or Suffix .................................................... 40 15. Setting Prefixes (Identifying the Symbology) ................................ 41 16. Setting Suffixes (Identifying the Symbology) ................................ 43 17. Direct Input of Numeric Characters ............................................. 45 18. Direct Input of Alpha Characters ................................................. 46 19. Direct Input of Alpha Characters (Lower Case)…………………………….47 20. Direct Input of Control Characters ............................................... 48 21. Direct Input Characters Miscellaneous………………………………………..50 22. Code Identification & Number of Characters/Digits Transmitted ..... 52 23. Communication Parameters ........................................................ 53 24. Handshaking ............................................................................. 55 25. Buzzer Operation ....................................................................... 57 26. Positive & Negative Bar Codes .................................................... 58 27. Setting the Trigger & Auto-Trigger Functions ............................... 58 28. Selecting the Read Mode ............................................................ 59 29. Parallel Read Mode.…………………………………………………………………. 60 30. Add-on Wait Mode…………………………………………………………………….60 31. Scanner Timeout (Trigger Enabled Mode only) ............................. 61 32. Multiple Read Reset Time………………………………………………………….62 33. Quiet Zone Options…………………………………………………………………..63 34. Redundant Decoding.................................................................. 64 35. Transmitting Error Indications (Trigger Enabled only) ................... 65 36. Good Read LED Operation .......................................................... 66 Page 24

Page 29

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

1. Global Default & Scanner Configurations Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

Return all parameters to Default settings

V3

Z1

Transmit software version

[2

Z2

Save all values set by command (not lost upon power off)

[3

Z3

Display software settings including prefix/suffix

[!

U2

%

Note: Where computer commands appear in parenthesis, bar code commands must be used to start and end manual programming of the scanner.

%) symbol throughout the menus to

Note: Scanner default settings are indicated by a pointing hand ( follow.

* Use Z2 (Save all values set by command) after computer command to store settings in memory prior to power off.

Page 25

Page 30

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

2. Symbology Selection Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

A0

Enable all bar code symbologies

B1

J0

Enable all UPC and EAN

K1

A2

Only Code-39

B3

A3

Only Codabar (NW-7)

B!

A4

Only IATA

B5

A5

Only Code-93

B6

A6

Only Code-128 (Inc. EAN-128)

B7

A7

Only MSI/Plessey

B8

A9

Telepen

B:

J1

Only UPC (A/E)

K2

J2

Only UPC (A/E)+2

K3

J3

Only UPC (A/E)+5

K! CONTINUED ON NEXT PAGE…