The text of a manual · part 3 of 8
User's Manual LMD 1135 Miniature High Speed Laser Fixed Position Scanner (OSE Command Set), pages 21 to 30
Pages 21 to 30 of 73
The original document is the PDF (361 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Opticon LMD-1135
Page 21
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
Appendix A Programming the Scanner Two different methods can be used to program parameters to configure the scanner: a. Programming via Computer Commands b. Programming via special Bar Codes from a menu page Most parameters can be programmed using either of these two methods. However, there are certain parameters that are only programmable via the bar code menu.
a. Programming via Computer Commands Parameters can be programmed by sending software commands or keyboard strokes from the host computer to the scanner in the following format: <ESC> Computer Command <CR> Note:
Only upper case letters are recognized, e.g., “AB” not” ab” Each command normally consists of two characters Downloading of software commands cannot be “grouped” together. Each command must be preceded by <ESC> and followed by a <CR>
Parameters programmed by downloaded commands can be stored permanently by transmitting a “<ESC> Z2 <CR>” command. It is not necessary to send a “Z2” command after each parameter is changed. One Z2 command will save all changes Appendix B lists all of the Computer Commands. In Appendix C, Bar Code Programming Menus, the lefthand column in all menus contains the Computer Command associated with that bar code.
b. Programming via Bar Codes Use the following steps to program parameters via the bar code menus: 1. Scan the “Start/End” bar code. This instructs the scanner to enter the Programming Mode. While in this mode the scanner will beep intermittently. 2. Scan the bar code(s) associated with the desired parameter(s). The scanner will beep when the bar code is read. Note: because of the close proximity of bar codes on the page, it is important to aim carefully to ensure that only the desired bar code is scanned. 3. Scan the “Start/End” bar code. This instructs the scanner to exit the Programming Mode.
All the parameters that were scanned are retained in memory and are stored permanently (even if the scanners is power down) or until they are changed again. Page 17
Page 22
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
When the scanner is in the Programming Mode, you can change more than one parameter at a time. However, this may become confusing. Until you become proficient at programming you may prefer to change only a few parameters at one time. We recommend that you keep a record of the changes you have made to the scanner.
What if you make a mistake? Don’t worry. If you are programming the scanner but are unsure of which parameters have been changed, scan the Reset All Defaults bar code. This bar code returns the scanner to the default settings that were installed in the factory at the time the product was manufactured. Scanning this bar code erases any change you have made, including any changes that were made during previous programming. Reset All Defaults U2 Command (U2) This command will also return all settings to the defaults that were installed in the factory
Page 18
Page 23
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
Appendix B Computer Programming Commands All commands must be preceded by an 'ESC' character (ZZ) and be followed by a 'Carriage Return' character (1C). Shaded areas indicate factory default settings.
Enable
Global Defaults
JD
JZ
TriOptic
U2
Enable Factory Default Settings
RA
R9
SCode
Z1
Transmit software version
Enable
Z2
Save all values set by command
E2
Z3
Display software settings (inc, prefix/suffix).
UPC-A (13 Digits) Transmit leading zero & CD
E3
UPC-A (12 Digits) No leading zero but transmit CD
E4
UPC-A (12 Digits)Transmit leading zero but No CD
E5
UPC-A (11 Digits) No leading zero & no CD transmitted
E6
UPC-E (8 Digits)Transmit leading zero & CD
E7
UPC-E (7 Digits) No leading zero but transmit CD
E8
UPC-E (7 Digits) Transmit leading zero but no CD
E9
UPC-E (6 Digits) No leading zero & no CD transmitted
6Q
Transmit UPC-E as is
6P
Transmit UPC-E as UPC-A
Only
Disable
Add
Symbology Selection
A0
Enable all symbologies
B0
Disable all symbologies
J0
Enable all UPC and EAN
A2
B2
Code 39
A3
B3
Codabar (NW-7)
A4
B4
IATA
A5
B5
Code 93
A6
B6
Code 128 (Inc. EAN-128)
A7
B7
MSI/Plessey
A9
B9
Telepen
J1
R1
UPC (A/E)
J2
R2
UPC (A/E)+2
J3
R3
UPC (A/E)+5
J4
R4
EAN (13/8)
J5
R5
EAN (13/8) +2
J6
R6
EAN (13/8) +5
J7
R7
2 or 5 Industrial
J8
R8
2 or 5 Interleaved
Disable
Options for UPC
Enable
Disable
Options for EAN-8 & EAN-13
6K
6J
EAN-13 Transmit CD
6I
6H
EAN-8 Transmit CD
IA
IB
Enable ISBN translation
HO
HN
Enable ISSN translation
Page 19
Page 24
Manual No. 25-ULPNR102-01; Mar, 2005
Enable
Disable
LMD 1135 Laser Fixed Mount Scanner
Options for Code 39
Enable
Disable
Options for 2 of 5 / SCode
8E
Enable 1 character read
G1
G0
Calculate check digit
8D
Enable 3 character read
E0
E1
Transmit check digit
C0
C1
Enable Check Digit calculation
GE
Enable 1 character minimum
D9
D8*
Transmit Check Digit
GF
Enable 3 characters minimum
D0
D1
Transmit start/stop characters (*…..*)
GI
Enable 5 characters minimum
+L
+M
Concatenation
-Y
-Z
Alternative algorithm
*Only disable if C0 enabled, otherwise truncate last digit.
Enable
Disable
D6 DB
Enable
Options for IT Pharmaceutical
GG
GH
Transmit S-Code as Interleaved 2 of 5
-Y
-X
Alternative Algorithm
Enable
Disable
Options for IATA
4H
Do not calculate check digit
4J
Calculate CD (CPN + Form + Serial)
4I
Calculate CD (Form + Serial)
4K
Calculate check digit (all data)
IT Pharmaceutical only DA
Disable
Transmit Leading A
Options for Codabar (NW-7)
HC
Enable 1 character read minimum
HB
Enable 3 character read minimum
HF
Enable 5 character read minimum
F0
Do not transmit start/stop characters
F1
Transmit start/stop as ABCD/TN*E
F2
Transmit start/stop as abcd/tn*e
F3
Transmit start/stop as ABCD/ABCD
F4
Transmit start/stop as abcd/abcd
H8
H9
Transmit check digit
H6
H7
Calculate check digit
HH
HI
Intercharacter gap check
-Y
-X
Alternative Algorithm
4L
4M
Transmit check digit
-Y
-X
Alternative Algorithm
Enable
Disable
JF
OF
EAN-128 Only
MO
MP
Concatenation
Enable
Disable
+V
+W
Options Code 128/EAN 128
Options for Code 93 Concatenation
Fixed Number of Digits H1
Fixation on all symbologies
HK
Fixation on selected symbologies
HL
Minimum length selected symbologies
HM
Maximum length selected symbologies
H0
Disable fixation on all symbologies
Page 20
Page 25
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
Prefix/Suffix of Control Characters Prefix
Suffix
Select Symbology for Prefix/Suffix
1B
STX
RY
RZ
All codes
1C
ETX
N1
N6
UPC-A
1M
Carriage Return
M0
O0
UPC-A +2 or +5
1J
Line Feed
N2
N7
UPC-E
M1
O1
UPC-E +2 or +5
N3
N8
EAN13
M2
O2
EAN-13 +2 or +5
N4
N9
EAN-8
M3
O3
EAN-8 +2or +5
M4
O4
Code 39
M5
O5
Codabar (NW-7)
M6
O6
Industrial 2 of 5
M7
O7
Interleaved 2 of 5
K0
150 baud
M8
O8
Code 93
K1
300 baud
M9
O9
Code 128
K2
600 baud
I8
I9
IATA
K3
1,200 baud
N0
N5
MSI/Plessey
K4
2,400 baud
MB
OB
SCode
K5
4,800 baud
L8
L9
Telepen
K6
9,600 baud
K7
19,200 baud
K8
38,400 baud
L0
7 Data Bits
L1
8 Data Bits
L2
Parity = None
L3
Parity = Even
L4
Parity = Odd
L5
1 Stop bit
L6
2 Stop bits
Prefix/Suffix of Numeric Characters
Q0
0 thru thru
Q9
9 Prefix/Suffix of Alpha Characters
0A
A thru thru
0Z
Z
Code ID & Character Length Transmission $2
Code identification
$3
Code length 2 digits
$6
Code length 6 digits
Communications Parameters
Page 21
Page 26
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
Handshaking
Positive & Negative Bar Codes
I0
Unlimited wait for CTS from terminal
V2
Positive bar codes only
I1
100 mS wait for CTS from terminal
V3
Only negative bar codes
I2
200 ms wait for CTS from terminal
V4
Both positive and negative bar codes
I3
400 mS wait for CTS from terminal
P0
No Handshaking
P1
Busy/Ready
P2
Modem
P3
ACK/NAK (1 second timeout with error buzzer)
P4
ACK/NAK no response (100 ms timeout, terminates with good read buzzer)
ZG
XON/OFF
KA
No intercharacter delay
KB
20 ms intercharacter delay
KC
50 ms intercharacter delay
KD
100 ms intercharacter delay
Buzzer Operation
Setting the Trigger & Auto-Trigger Functions S7
Disable the trigger function (Laser On)
S8
Enable the trigger function (Laser OFF until the trigger is activated )
+F
Auto-Trigger Disable
+I
Auto-Trigger Enable
Z
Activate the trigger; turns the laser ON
Selecting the Read Mode S0
Single Read Mode (Trigger must be Enabled, S8)
S1
Multiple Read Mode
S2
Continuous Read Mode
T0
Volume = Maximum
T1
Volume = Upper mid-range
T2
Volume = Lower mid-range
+6
2 Parallel labels only
T3
Volume = Minimum
+7
3 Parallel labels only
W0
Disable Buzzer
+8
4 Parallel labels only
W1
Enable buzzer at 3kHz
W2
Enable buzzer at 3kHz with 2.5kHz interval
W3
Enable buzzer at 3kHz with 4kHz interval
W4
Buzzer duration 0.10 sec
W5
Buzzer duration 0.20 sec
W6
Buzzer duration 0.40 sec
W7
Buzzer duration 0.05 sec
W8
Enable buzzer
Parallel Read Mode
Page 22
Page 27
Manual No. 25-ULPNR102-01; Mar, 2005
Scanner Timeout (Trigger Enabled Mode) Y1
1 second after triggering
Y2
2 second after triggering
Y3
3 second after triggering
Y4
4 second after triggering
Y5
5 seconds after triggering
Y6
6 second after triggering
Y7
7 seconds after triggering
Y8
8 seconds after triggering
Y9
9 seconds after triggering
YL
Read time x 10
YM
Indefinitely after triggering
XA
Add-on Wait Time - Disable
XB
Add-on Wait Time – 250 msec
XC
Add-on Wait Time – 500 msec
XD
Add-on Wait Time – 750 msec
LMD 1135 Laser Fixed Mount Scanner
YR
Margin check 4/7 nominal
YS
Margin check 5/7 nominal
YT
Margin check 6/7 nominal
YU
Margin check normal
Redundant Decoding X0
Read bar code once
X1
Read bar code twice before transmitting
X2
Read bar code three times before transmitting
X3
Read bar code four times before transmitting
BS
Read bar code five times before transmitting
BT
Read bar code six times before transmitting
BU
Read bar code seven times before xmitting
BV
Read bar code eight times before xmitting
BW
Read bar code nine times before xmitting
Xmit Error (Trigger Enabled Mode only) TH
User defined error message for no label
TI
User defined error message for no decode
TG
Clear error messages for no label, no decode
WD
Response to command - None
WC
Response to command – OK=ACK, ERROR=NAK
AH
Multiple Read Reset Time – 50 msec
AI
Multiple Read Reset Time – 100 msec
AJ
Multiple Read Reset Time – 200 msec
AK
Multiple Read Reset Time – 300 msec
AL
Multiple Read Reset Time – 400 msec
AM
Multiple Read Reset Time – 500 msec
AN
Multiple Read Reset Time – 600 msec
WB
Buzzer Control to Command - Disable
AG
Multiple Read Reset Time - Indefinite
WA
Buzzer Control to Command - Enable
Quiet Zone Options
Good Read LED Operation
YN
No margin check
T4
Disable good read LED (GRL)
YO
Margin check 1/7 nominal
T5
GRL ON for 0.20 seconds after decode
YP
Margin check 2/7 nominal
T6
GRL ON for 0.40 seconds after decode
YQ
Margin check 3/7 nominal
T7
GRL ON for 0.80 seconds after decode
Page 23
Page 28
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
Appendix C: Bar Code Programming Menus & Commands - Index 1. Global Default & Scanner Configurations....................................... 25 2. Symbology Selection ................................................................... 26 3. Add/Activate Specific Bar Code Symbologies ................................. 28 4. Delete/Deactivate Specific Bar Code Symbologies.......................... 29 5. Options for UPC.......................................................................... 30 6. Options for EAN-8 & EAN-13……………………………………………………….31 7. Options for Code-39 & IT Pharmaceutical) .................................... 32 8. Options for Codabar (NW-7) ........................................................ 34 9. Options for 2 of 5 (Including SCode) ............................................ 36 10. Options for IATA....................................................................... 37 11. Options for Code-128 & EAN-128……………………………………………….38 12. Options for Code-93………………………………………………………………….38 13. Fixing the Number of Digits ........................................................ 39 14. Creating a Prefix and/or Suffix .................................................... 40 15. Setting Prefixes (Identifying the Symbology) ................................ 41 16. Setting Suffixes (Identifying the Symbology) ................................ 43 17. Direct Input of Numeric Characters ............................................. 45 18. Direct Input of Alpha Characters ................................................. 46 19. Direct Input of Alpha Characters (Lower Case)…………………………….47 20. Direct Input of Control Characters ............................................... 48 21. Direct Input Characters Miscellaneous………………………………………..50 22. Code Identification & Number of Characters/Digits Transmitted ..... 52 23. Communication Parameters ........................................................ 53 24. Handshaking ............................................................................. 55 25. Buzzer Operation ....................................................................... 57 26. Positive & Negative Bar Codes .................................................... 58 27. Setting the Trigger & Auto-Trigger Functions ............................... 58 28. Selecting the Read Mode ............................................................ 59 29. Parallel Read Mode.…………………………………………………………………. 60 30. Add-on Wait Mode…………………………………………………………………….60 31. Scanner Timeout (Trigger Enabled Mode only) ............................. 61 32. Multiple Read Reset Time………………………………………………………….62 33. Quiet Zone Options…………………………………………………………………..63 34. Redundant Decoding.................................................................. 64 35. Transmitting Error Indications (Trigger Enabled only) ................... 65 36. Good Read LED Operation .......................................................... 66 Page 24
Page 29
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
1. Global Default & Scanner Configurations Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
Return all parameters to Default settings
V3
Z1
Transmit software version
[2
Z2
Save all values set by command (not lost upon power off)
[3
Z3
Display software settings including prefix/suffix
[!
U2
%
Note: Where computer commands appear in parenthesis, bar code commands must be used to start and end manual programming of the scanner.
%) symbol throughout the menus to
Note: Scanner default settings are indicated by a pointing hand ( follow.
* Use Z2 (Save all values set by command) after computer command to store settings in memory prior to power off.
Page 25
Page 30
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
2. Symbology Selection Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
A0
Enable all bar code symbologies
B1
J0
Enable all UPC and EAN
K1
A2
Only Code-39
B3
A3
Only Codabar (NW-7)
B!
A4
Only IATA
B5
A5
Only Code-93
B6
A6
Only Code-128 (Inc. EAN-128)
B7
A7
Only MSI/Plessey
B8
A9
Telepen
B:
J1
Only UPC (A/E)
K2
J2
Only UPC (A/E)+2
K3
J3
Only UPC (A/E)+5
K! CONTINUED ON NEXT PAGE…
Page 26