User's Manual LMD 1135 Miniature High Speed Laser Fixed Position Scanner (OSE Command Set), pages 1 to 10

Pages 1 to 10 of 73

The original document is the PDF (361 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Opticon LMD-1135

Page 1

User’s Manual

LMD 1135

Miniature High Speed Laser Fixed Position Scanner Manual No. 25-ULPNR102-01 March, 2005 (OSE Command Set)

8 Olympic Drive Orangeburg, NY 10962 Tel 845.365.0090 Fax 845.365.1251 www.OpticonUSA.com

Page 2

This page is a scan with no text; see it in the PDF.

Page 3

Contents Section 1 Introduction and Getting Started Product Overview Quick Start-Up Procedure

1 1 1

Section 2 Technical Specifications Physical Specifications Symbologies Supported Optical Specification Pitch Skew Tilt (rotation) Curvature Electrical Specification RS232 Communications Specifications Connector Pin Outs Environmental Specifications Ordering Information

3 3 3 3 4 4 5 5 5 6 6 7 7

Section 3 Positioning the Scanner Achieving Optimum Performance Measuring Scanner Performance Tips for Achieving High Throughput Tips for Insuring Highest Data Integrity Tips for Verifying the Presence of a Bar Code

8 8 10 11 11 12

Section 4 Configuring the Scanner Configuring the Scanner Default Setting

13 13 13

Section 5 Application Engineering Support Common Causes of Poor Performance

14 14

Section 6 Scanner Labeling

15

Section 7 Scanner Servicing and Maintenance

15

Appendix A How to Program the Scanner

17

Appendix B Computer Programming Commands

19

Appendix C Bar Code Programming Commands

24

Appendix D Dimensional Drawings

67

Appendix E Optical Performance (Typical)

68

Page 4

Organization of this Manual This manual provides the necessary instructions for installing and using the Opticon LMD 1135 Fixed Position Scanner. The manual is organized as follows:

Section 1

Introduction and Getting Started Describes the general operation of the LMD 1135 scanner. Also provides a Quick StartUp Procedure that allows you to begin using the scanner immediately.

Section 2

Technical Specifications Provides complete specifications, including mechanical details, optical performance, RS232 communications and other technical data.

Section 3

Positioning the Scanner for Optimum Performance Provides detailed instructions and tips for mounting and positioning the scanning to obtain the best scanning performance. Application Notes describe guidelines for maximizing specific characteristics.

Section 4

Configuring the Scanner Describes how various parameters can be programmed to customize the scanner for your specific application.

Section 5

Application Engineering Support Discusses the most common questions and concerns when adapting the LMD 1135 and scanner in your application.

Section 6

Scanner Labels Discusses the various labels on the product required by CDRH.

Section 7

Scanner Servicing and Maintenance Discusses maintenance and cleaning procedures.

Appendix A Appendix B Appendix C Appendix D Appendix E

How to Program the Scanner Computer Programming Commands Bar Code Programming Commands Dimensional Drawing Optical Performance

Page 5

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Section 1 Introduction and Getting Started Product Overview The LMD 1135 Fixed Position Scanner is a miniature, 100 scan per second, laser bar code reader designed to be easily incorporated into host equipment. The small physical size makes the scanner easy to integrate into any hardware design. Durability and reliability are assured. Advanced microprocessor technology coupled with Opticon’s proven decoding algorithms result in high speed operation with superior accuracy. The scanner is fully programmable allowing the user to customize parameters including changing communication settings, selecting symbologies, adding prefixes and appending suffixes. Programmable settings can be downloaded from the host CPU or computer directly to the scanner. The scanner is encased in a compact, rugged, yet lightweight-plastic enclosure. The compact size permits installation in the tightest areas allowing great flexibility in mounting and positioning the scanner for optimum performance.

Quick Start-Up Procedure This section is for those who wish to start using the scanner before reading the complete manual. In only a few steps the scanner will be operable. Turn off the power to your PC and connect the scanner to an RS232 communications port. Note: You must provide +5 Volt DC power to the scanner. If you are using our standard LPN1137RR1S-050 or have purchased the evaluation kit, you can utilize power supply, P/N 32-00907-01, by plugging its connector directly into the pigtail connector on the scanner. If the power supply is obtained from another source verify that it is identified with the CE mark. Turn on the power to the PC. 1) Using communications software (e.g., Procom), set the communication parameters: 9600 baud, 1 Start/Stop Bit, 8 Data Bits, No Parity, No Handshaking, No Flow Control 2) If you are operating in a Microsoft Windows 3.1 environment, skip to Step 5. 3) If you are operating in a Microsoft Windows 95/98/ 2000/ XP environment, you can set the communication parameters using Hyper Terminal as follows: ♦

Open Hyper Terminal. This can be done from Start→Programs→Accessories/ Communications

♦

Select Hypertrm.exe to create a New Connection

♦

In the Connection Description dialog screen enter a name for the new file. If desired, select an Icon. Click OK

♦

In the Connect To (Phone Number) dialog screen, in the box entitled: Connect using. select the communication port, for example, “Direct to Com 1” Click OK

♦

In the Com 1 Properties screen, enter the appropriate Port Settings: Bits per second = 9600, Data bits = 8, Parity = None, Stop Character = 1, Handshaking = None, Click OK

♦

The hyper-terminal folder you just created will open. From the File pull-down menu, select Properties then click on the Setting Tab

Page 1

Page 6

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

♦

In the Properties Settings dialog screen, Select Terminal keys for the Function, arrow and control key; then Select ANSI for Emulation; the Back scroll buffer line can remain at the default 500

♦

Click on the ASCII Setup button. In the ASCII Setup Sending screen, select Line ends with line feeds and Echo typed locally so that any keyboard commands you input will appear on your screen. In the ASCII Setup Receiving screen, select Append line feeds to incoming line ends and Wrap lines that exceed terminal width. Click OK. This returns you to the Properties Setting. Click OK

4) Your PC and the scanner should now communicate. Skip to Step 6. 5) In a Microsoft Windows 3.1 environment, set the communication parameters using the Terminal function of Windows. a) From Window’s Program Manager Main Menu, select Terminal. ♦

From the Terminal menu, select Settings.

♦

From the Settings menu, select Terminal Emulation.

♦

Set the emulation to TTY (generic).

♦

From the Settings menu, select Terminal Preferences and select the following Terminal Modes: Line Wrap Local Echo Sound CR /LF: Inbound, Outbound Columns: 80 From the Settings menu, select Communications , select the COM port, and set communication parameters as shown in Step 2, including no flow control

6) To verify that the scanner and the PC are communicating properly, send the following command from your PC keyboard which will request software settings to be displayed. Send the command in four keystrokes: <Escape> Z3 <Carriage Return> Note: Be sure to use capital letters, e.g. “Z3”, not “z3”. A series of software setting should be displayed, indicating that good communications have been established 7) A red laser light should be visible. If it is not visible, the scanner may be in a mode that requires a “Trigger” Command from the PC to activate it. You can exit that mode by sending the following command from your PC keyboard: <Escape> S7 <Carriage Return> 8) The “Trigger” mode will now be deactivated and the red laser light will be continuously illuminated. This Quick Start-Up procedure will get you started. However, to best understand the full capabilities of this scanner, you should read the complete manual.

Page 2

Page 7

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Section 2 Technical Specifications Physical Specifications Case Material Dimensions Weight Cable Length Connector Mounting

Plastic 2.2 x 1.9 x 1.0 in (WxDxH) (55 x 47.5 x 25.5 mm) 2.1 oz (60 grams ) w/o cable 6.5 Feet (2000 mm) 9-pin, DB9F-SC connector with power pigtail (evaluation configuration) 4 threaded (M-3) mounting holes located on scanner bottom face

Symbologies Supported ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Codabar (NW-7) Code 39 Code 93 Code 128 Industrial 2 of 5 / Interleaved 2 of 5 MSI / Plessey WPC (UPC / EAN / JAN) IATA Telepen TriOptic SCode

Optical Specifications Scan Rate Light source Narrow Bar Resolution Minimum PCS

100 scans per second ±20% 650 ±10nm visible laser diode 5 mil (0.15mm) at 0.9 PCS 0.45 (min. background reflectance of 70%)

Reading Distances LMD 1135 (Specification) * (See Typical in Appendix E) Near Distance Bar Code Density 40 mil (1.00 mm) 4.3” (110mm) 20 mil (0.50 mm) 3.1” (80mm) 10 mil (0.25 mm) 2.4” (60mm) 6 mil (0.15 mm) 1.8” (45mm) 5 mil (0.127 mm) 2.2” (55mm) * measured from front edge of scanner

Far Distance 14.2” (360mm) 9.8” (250mm) 5.7” (145mm) 3.1” (80mm) 2.8” (70mm)

Page 3

Page 8

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Pitch

Specified operation (α) at + 50 degrees or less. (Recommended at + 13 degrees) Avoid specular reflection in the dead zone (+/- 8 degrees).

Skew

Specified operation (α) + 30 degrees or less. (Recommended 0 degrees)

Page 4

Page 9

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Tilt (Rotation)

Specified operation (θ) + 20 degrees or less. (Barcode aspect ratio allowing laser to cover all bars). (Recommended operation at 0 degrees) Curvature Curvature

EAN-8: R = 15 mm (0.6”) or h

R

JAN 13: R = 30 mm (1.2" ) or EAN-13: R= mm(0.8") (0.8”).or JAN 8: R= 2020mm 35.4 Where: PCS 0.9, 0.9,h h==100 Where: PCS mm, α2 = 10°,β = 0°, θ= 0° Pitch=15°, Skew=0°, Tilt=0°

Electrical Specifications Operating Voltage Current Operating Idle Pwr-On Surge

+5VDC + 10% 85mA (typical), 150mA (max) 55mA (typical), 70mA (max) 650mA (typical), 1500mA (max)

Page 5

Page 10

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

RS232 Communications Specifications RS232 Data Transmission Format Parameter Timing No. of Start Bits No. of Stop Bits No of Data Bits Parity Baud Rate Handshaking

Default Asynchronous 1 bit 1 bit 8 bit None 9600 baud None

Optional Settings 1 or 2 bits 7 or 8 bits Odd / Even / None 150 to 38,400 baud Hardware / Software/ None

RS232 Transmit / Receive Character Format TXD/ RXD

Start Bit

LSB

7 or 8 Data Bits

Parity Bit

MSB

Stop Bit

RS232 Data Format Transmit

Decoded Data ESC Command STX Command

Receive

CR CR ETX

RS232 Signal Level Signal Name TXD RXD

In / Out Out In

Mark/Off -5 to -15 -3 to -15

Space/On +5 to +15 +3 to +15

Connector Pin-outs 9 Pin D-Sub Female Connector (with power stereo jack) Pin No. 1 2 3 4 5 6 7 8 9

Signal Frame Ground TxD RxD NC Signal Ground NC CTS RTS NC

Direction Output Input

Input Output

Page 6