The text of a manual · part 5 of 5
Users Manual Handheld CCD Wedge Interface 25-WEDGE-06, pages 41 to 49
Pages 41 to 49 of 49
The original document is the PDF (154 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Opticon 25-WEDGE-06
Page 41
Keyboard Emulation Options Keyboard emulation options allow the user to emulate the function, arrow and other keys on the computer keyboard. Also, the user has the option of transmitting all upper case or all lower case characters. To begin Keyboard emulation mode, first scan “Start”, then “Keyboard Emulation On”, then “End”. To emulate one of the function or arrow keys, do not scan “Start” before scanning the keyboard emulation bar code. NOTE: Function key emulation cannot be performed while “Full ASCII Code 39” is enabled.
Z9
Start/End Program Menu
,Z9,
D6
Keyboard emulation mode off
,D6, B
D7
Keyboard emulation mode on
,D7,
O6
Xmit all upper case
,O6,
O7
Xmit all lower case
,O7,
O8
Reverse upper & lower case
,O8,
O9
Xmit normal
,O9, B Page 37
Page 42
Keystroke Emulation Options List of all keystroke emulated bar code that are only functional when Keyboard Emulation is on. Scanning “Start” is not required to read these codes.
/-1
F1
*/-1*
/-2
F2
*/-2*
/-3
F3
*/-3*
/-4
F4
*/-4*
/-5
F5
*/-5*
/-6
F6
*/-6*
/-7
F7
*/-7*
/-8
F8
*/-8*
/-9
F9
*/-9* CONTINUED ON NEXT PAGE...
Page 38
Page 43
Keystroke Emulation Options
/-A
F10
*/-A*
/-B
F11
*/-B*
/-C
F12
*/-C*
/-D
Page up
*/-D*
/-E
Page down
*/-E*
/-F
Home
*/-F*
/-G
End
*/-G*
/-H
Arrow up
*/-H*
/-I
Arrow down
*/-I* CONTINUED ON NEXT PAGE...
Page 39
Page 44
Keystroke Emulation Options y/o TANITA r favo) THTNTITTMMTT TH ef eee [ARNT
Page 40
Page 45
Trigger Options Select the appropriate bar code to enable or disable the trigger. By disabling the trigger, the scanner LED’s remain on as long as the computer power is on.
Z9
Start/End Program Menu
Y0
Enable trigger
,Y0, B
Y1
Disable trigger
,Y1,
,Z9,
Page 41
Page 46
Beeper Settings Z9
Start/End Program Menu
,Z9,
W0
Disable beeper
,W0,
W1
Beep before Xmit
,W1, B
W2
Beep after Xmit
,W2,
W3
Disable good read light
,W3,
W4
Good Read with beep
,W4,
W5
Good Read after beep
,W5,
Page 42
Page 47
Transmit Current Settings These codes transmit the current settings (check digit transmission, for example) for the symbologies listed.
Z9
Start/End Program Menu
,Z9,
Q0
Send software switches
,Q0,
Q1
Send Code 39 info
,Q1,
Q2
Send Codabar info
,Q2,
Q3
Send I 2 of 5 Info
,Q3,
Q4
Send D 2 of 5 info
,Q4,
Q5
Send Code 128 & 93 info
,Q5,
Q6
Send MSI/Plessey info
,Q6,
Q7
Send UPC-A info
,Q7, CONTINUED ON NEXT PAGE... Page 43
Page 48
Transmit Current Settings
Z9
Start/End Program Menu
,Z9,
Q8
Send UPC-E info
,Q8,
Q9
Send EAN-13 & EAN-8 info
,Q9,
QA
Send Code 4 & Code 5 info
,QA,
QB
Send system info
,QB,
Page 44
Page 49
Read Mode Select decoding and transmission options from the Read Mode menu. The options “Read X Times” process the bar code data through the decode algorithm X times before transmitting the data to the keyboard port (the default setting is “Read 2 Times”). The “Single Read” option turns off the scanner LED’s immediately after transmission. By selecting the “Multi-Read” option, the scanner LED’s remain on for a brief period after transmission of the data.
Z9
Start/End Program Menu
,Z9,
X0
Read once
,X0,
X1
Read 2 times
,X1, B
X2
Read 3 times
,X2,
X3
Read 4 times
,X3,
X4
Single Read
,X4, B
X5
Multi Read
,X5, Page 45