Page 31
Codabar Settings Options for Codabar (also known as NW-7).
Z9
Start/End Program Menu
,Z9,
E0
Codabar CD computation off
,E0, B
E1
Codabar CD computation on
,E1,
E2
Codabar CD Xmit off
,E2,
E3
Codabar CD Xmit on
,E3,
E4
Codabar start/stop match off
,E4,
E5
Codabar start/stop match on
,E5, B
F0
Codabar start/stop xmit off
,F0,
F1
Codabar start/stop as ABCD/TN*E
,F1, CONTINUED ON NEXT PAGE... Page 27
Page 32
Codabar Settings
Z9
Start/End Program Menu
,Z9,
F2
Codabar start/stop as abcd/tn*e
,F2,
F3
Codabar start/stop as ABCD/ABCD
,F3,
F4
Codabar start/stop as abcd/abcd
F5
Codabar single digit off
,F4, B ,F5, B
F6
Codabar single digit on
,F6,
Page 28
Page 33
2 of 5 Settings Options for I 2 of 5 (Interleaved 2 of 5) and D 2 of 5 (Industrial 2 of 5).
Z9
Start/End Program Menu
,Z9,
G0
I 2 of 5 CD computation off
,G0, B
G1
I 2 of 5 CD computation on
,G1,
G2
I 2 of 5 CD Xmit off
,G2,
G3
I 2 of 5 CD Xmit on
,G3, B
G4
I 2 of 5 leading "0" Xmit off
,G4,
G5
I 2 of 5 leading "0" Xmit on
,G5, B CONTINUED ON NEXT PAGE...
Page 29
Page 34
2 of 5 Settings
Z9
Start/End Program Menu
,Z9,
G6
D 2 of 5 CD computation off
,G6, B
G7
D 2 of 5 CD computation on
,G7,
G8
D 2 of 5 CD Xmit off
,G8,
G9
D 2 of 5 CD Xmit on
,G9, B
Page 30
Page 35
Code 128 & MSI/Plessey Settings Z9 C6 C7
Start/End Program Menu Code 128 CD computation off Code 128 CD computation on
,Z9, ,C6, ,C7, B
J0
MSI/Plessey CD Xmit on
,J0, B
J1
MSI/Plessey 1 CD Xmit off
,J1,
J2
MSI/Plessey 2 CD Xmit off
,J2,
J3
MSI/Plessey with 1 CD
,J3, B
J4
MSI/Plessey with mod 10/mod 10
,J4,
J5
MSI/Plessey with mod 11/mod 11
,J5,
Page 31
Page 36
Intercharacter Delay For some application programs and IBM compatibles, the scanner may send data faster than the computer or application program can accept. this is called “keyboard buffer overrun”. If data appears to be missing, random read errors occur or the scanner locks up and will not scan, experiment with the various keyboard timing options listed in the menu to follow.
Z9
Start/End Program Menu
I0
10 ms delay
,I0, B
I1
20 ms delay
,I1,
I2
30 ms delay
,I2,
I3
40 ms delay
,I3,
I4
50 ms delay
,I4,
,Z9,
CONTINUED ON NEXT PAGE...
Page 32
Page 37
Intercharacter Delay
Z9
Start/End Program Menu
,Z9,
I5
60 ms delay
,I5,
I6
70 ms delay
,I6,
I7
80 ms delay
,I7,
Page 33
Page 38
Scan Code Delay The timing of he keyboard house-keeping codes are set by these commands.
Z9
Start/End Program Menu
L2
2 ms delay
,L2, B
L3
4 ms delay
,L3,
L4
6 ms delay
,L4,
L5
8 ms delay
,L5,
L6
10 ms delay
,L6,
L7
12 ms delay
,L7,
Page 34
,Z9,
Page 39
Bar Code Length Options One or two lengths may be selected for free format bar codes. Only free format bar codes of the selected length(s) will be accepted.
Z9
Start/End Program Menu
,Z9,
H0
Fixed length mode
,H0,
H1
Free 2 of 5 length
,H1,
H2
Free Codabar length
,H2,
H3
Free MSI/Plessey length
,H3,
H4
Free Code 39 length
,H4,
H5
Free all lengths
,H5, B
Page 35
Page 40
Global Suffix Options * * Adds to all symbologies. The suffix menu enables the user to transmit a carriage return (“CR”), line feed (“LF”), tabs, etc. after transmission of the bar code data. NOTE: Only one suffix selection can be programmed at a given time.
Z9
Start/End Program Menu
,Z9,
O0
No suffix
,O0,
O1
Carriage return
,O1, B
O2
Line feed
,O2,
O3
Carriage return + line feed
,O3,
O4
Tab
,O4,
O5
Shift+Tab
,O5,
OA
Arrow down
,OA,
Page 36