Page 11

Troubleshooting A. If LED’s do not light up when installation instructions are followed: •

Make sure there is power to the system.

•

Recycle computer power.

•

Verify computer fuses are ok.

•

Check for loose cable connections.

•

Are adaptors being used?

B. If LED’s light up, but good read beep is not heard and no data appears on the computer: •

Make sure the distance between the scanner and bar code label is not greater than the specified depth-of-field when trying to read it.

•

Verify the bar code label is readable and meets bar code specification.

•

Check to see if the scanner reads other bar code labels (if yes, the non-reading label may be a label which the scanner is not programmed to decode.)

•

Verify that the bar code label is not wider than the CCD scan window. CONTINUED ON NEXT PAGE...

Page 7

Page 12

C. If LED’s light up, good read beep is heard but no data appears on the computer: •

Check to see that the “Computer Type Selection” matches the type of computer that you are using.

•

Change the “Intercharacter Delay” setting. Depending upon the type of computer that you are using, the intercharacter delay will vary.

•

If you are using a file sever, an interrupt conflict may arise. Opticon recommends using an RS232C CCD scanner interface on file servers.

NOTE: If after performing these checks, the scanner is still not functioning, contact your distributor or call Opticon Technical Support at 800-636-0090.

Factory Service When calling Opticon Technical Support, please have the unit model number and several bar code labels readily at hand. The model number is located near the connector end of the cable.

Page 8

Page 13

Technical Specifications Physical Case Material ABS Plastic; Ivory/Grey Dimensions (LxWxH) 2.3" window 5.5 x 2.5 x 2 inches 3.2" window 5.5 x 3.2 x 2 inches Weight 6 oz. Cable Length 5 ft. nominal Optical Photo Detector 2048 Element CCD array Scan Speed 50 scans/sec. Light Source Red LED (λ = 660 nm) Depth of Field (UPC 15 mil) 2.3” window 0 to 1” (63 mm) 3.2” window 0 to 2.5” (25.4 mm) Field Width 2.3" or 3.2" @ contact (optional) Min. Element Width 2.3” window .004" (4 mil) @ contact 3.2” window .006" (6 mil) @ contact Print Contrast 0.45 min. Electrical Supply Voltage Current

+5V DC ±10% 60 mA max.

Environmental Temperature Operating +32° to +105° F Storage -15° to +140° F Humidity RH (non-condensing) Operating Up to 80% Storage Up to 90% Interface Wedge

Keyboard Input

Page 9

Page 14

Ordering Information Accessories Available Part Number Description 28-KYDEX-01 “L-Style” Hands-free Stand 28-00010-01 Rubber Side-Mount Stand 28-UNVSTD-01 Universal Scanner Stand

Page 10

Page 15

FCC Information This equipment has been tested and is found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate RF energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communication. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at their own expense. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment.

Page 11

Page 16

Warranty This scanner is guaranteed for a period of five (5) years from date of shipment from Opticon, including all defects in material and workmanship for the first year and electronics only thereafter. Opticon will, at its option, repair or replace products which prove to be defective in material or workmanship under proper use within the warranty period. Opticon will consider any product out-of-warranty if the unit has been subjected to misuse, accident or incorrect installation. No other warranties are expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Opticon is not liable for consequential damages. If the scanner must be returned, please contact Opticon to obtain an RMA (Return Merchandise Authorization) number prior to returning the product. The Customer Service Dept. may be reached at 800-636-0090. NOTE: Returned merchandise will NOT be accepted without a RMA number indicated clearly on the outside of the carton.

Page 12

Page 17

Glossary ASCII - American Standard Code for Information Interchange. A 7 bit plus parity code representing 128 letters, numerals, punctuation marks, and control characters. It is a standard data transmission code in the US. Autodiscrimination - The ability of bar code reading equipment to recognize and correctly decode more than one symbology. Bar Code - An automatic identification technology which encodes information into an array of varying width parallel rectangle bars and spaces. Bar Code Density - The number of data characters which can be represented in a linear unit of measure. Bar code density is often expressed in characters per inch. CCD (Charged Coupled Device) - A technology in which scanning is accomplished with an array of LED’s flooding the bar code with light. Check Digit - A digit used to verify a correct symbol code. The scanner inserts the decoded data into an arithmetic formula and checks that the resulting number matches the encoded check digit. Check digits are required for UPC but are optional for other symbologies. Using check digits decreases the chance of substitution errors when a symbol is decoded. Codabar - A discrete self-checking code with a character set consisting of digits 0 to 9 and six additional characters (- $ : / , +). Code 128 - A high density symbology which allows the controller to encode all ASCII characters without adding extra symbol elements. Page 13

Page 18

Glossary (cont.) Code 3 of 9 (Code 39) - A versatile and widely used alphanumeric bar code symbology with a set of 43 characters types, including all upper case letters, numerals from 0 to 9 , and 7 special characters (- / . + % $ and space). The code name is derived from the fact that 3 of 9 elements representing a character are wide, while the remaining 6 are narrow. Decode - To recognize a bar code symbology and then analyze the content of the specific bar code scanned. Default - A standard setting assigned to a parameter type unless a different setting is assigned to that parameter. Depth of field - The distance between the maximum and minimum plane in which bar code reader is capable of reading symbols. EAN (European Article Number) - This European/International version of the UPC provides its own coding format and symbology standards. Element dimensions are specified metrically. EAN is used primarily in retail. Encode - To translate data into machine readable form using the format and conventions of a specific bar code symbology. Host Computer - A computer that serves other terminals in a network, providing such services as computation, database access, supervisory programs, and network control.

Page 14

Page 19

Glossary (cont.) Interleaved 2 of 5 - A binary code symbology representing character pairs in groups of five bars and five interleaved spaces. Interleaving provides for greater information density. The location of wide elements (bars/spaces) within each group determines which characters are encoded. This continuous code type uses no Inter-character spaces. Only numeric (0 to 9) and START/STOP characters may be encoded. Parameter - A setting that can have a different function assigned to it. Programming mode - The state in which a scanner is configured for parameter settings. Quiet Zone - A clear space, containing no machine readable marks, which precedes the start character of a bar code symbol and follows the stop characters. Read Rate - The ratio of the number of successful reads on the first attempt to scan to the total number of attempts. Resolution - In a bar code system, the narrowest element dimension which can be distinguished by a particular reading device or printed with a particular device or method. Scanner - An electronic device used to scan bar code symbols and produce a digitized pattern that corresponds to the bars and spaces of the symbol. Scanning Mode - The scanner is energized, programmed, and ready to read a bar code.

Page 15

Page 20

Glossary (cont.) Start/Stop Character - A pattern of bars and spaces that provides the scanner with start and stop reading instructions and scanning direction. The start and stop characters are normally to the left and right margins of a horizontal code. Symbology - The structural rules and conventions for representing data within a particular bar code type. UPC (Universal Product Code) - A relatively complex numeric symbology. Each character consists of two bar codes and two spaces, each of which can be any of four widths. The standard symbology for retail food packages in the United States. Wedge - A device that plugs in between a keyboard and a PC. Includes a scanner allowing data to be entered either by a keyboard or scanner.

Page 16