For the Opticon 25-WEDGE-06

Page 1

User’s Manual

Handheld CCD Wedge Interface

25-WEDGE-06 Ver. May 2000

8 Olympic Drive Orangeburg, NY 10962 Tel 845.365-0090 Fax 845.365-1251 www.opticonUSA.com

Page 2

This page is a scan with no text; see it in the PDF.

Page 3

Table of Contents PART I – CCD Scanning General Information .......................................... 1 Wedge Interface ............................................... 2 Set Up ............................................................. 3 Scanning .......................................................... 5 User Maintenance ............................................. 6 Troubleshooting ................................................ 7 Technical Specifications ..................................... 9 Ordering Information ....................................... 10 FCC Information .............................................. 11 Warranty ........................................................ 12 Glossary ......................................................... 13

NOTICE Opticon has taken every step to ensure that the information included in this manual is accurate, however we reserve the right to change any specification at any time without prior notice.

Page 4

Part II Bar Code Menu Functions Reset All Defaults ............................................ 17 Computer Type Selection ................................. 18 Symbology Selection ....................................... 19 Symbology Additions ....................................... 21 UPC Settings ................................................... 22 Code 39 Settings ............................................. 25 Codabar Settings ............................................ 27 2 of 5 Settings ................................................ 29 Code 128 & MSI/Plessey Settings .................... 31 Intercharacter Delay ........................................ 32 Scan Code Delay ............................................. 34 Bar Code Length Options ................................. 35 Global Suffix Options ....................................... 36 Keyboard Emulation Options ............................ 37 Keystroke Emulation Options ............................ 38 Trigger Options ............................................... 41 Beeper Settings .............................................. 42 Transmit Current Settings ................................ 43 Read Mode ..................................................... 45

Page 5

General Information CCD (charged coupled device) scanners are, depending on model type, either “contact” or “near contact” scanners. Because CCD’s scan automatically when approaching or pointing at a bar code label, their operation is intuitive. CCD’s read difficult labels found on curved or irregular surfaces and perform especially well in high ambient light conditions. They are a costeffective, inexpensive alternatives to other scanning technologies. Featuring state-of-the-art imaging technology, CCD’s use the same sensor found in facsimile machines or video camcorders. The CCD images the bar code label, then converts the digital signals into data the host computer can understand. By capturing the bar code image all at once, the scanner provides a fast, highly accurate read rate. Miniature surface mount electronics make up the CCD scanner’s solid state construction. CCD’s have no moving mechanical parts and provide years of trouble-free operation.

Page 1

Page 6

Wedge Interface The HLT/ELT series Wedges have built-in intelligence to connect directly to a personal computer without the need for a separate decoder box. Scanned bar code labels appear to the computer as if the data was typed into the keyboard. Normal operation of the keyboard is unaffected. The WEDGE interface is compatible with virtually any application program accepting keyboard input. Advantages • • • • • • •

Low cost – no separate decoder box required No special software installation or technical support needed Same communication signal format as keyboard Simple installation No external power supply Full featured bar code menu offers user flexibility Uses existing keyboard type

Page 2

Page 7

Set Up Unpacking Remove the scanner from its packaging and inspect it for damage. If the scanner was damaged in transit, call the Opticon Customer Service Dept. at 800-636-0090. Installation A “Y” connection cable is provided for installation. The scanner is installed or “wedged” between the keyboard and the computer’s CPU. The “Y” cable connects both the scanner and the keyboard to the computer.

WARNING! In order to avoid possibility of damage to the computer, install the CCD scanner and “Y” cable when power to the system is OFF.

Page 3

Page 8

Programming the Scanner This manual provides an easy way of changing certain parameters. A parameter is changed by reading a specific bar code associated to a specific function. To select menu options: 1.

Scan “Start/End Program Menu.” The scanner will beep continuously to indicate that it is ready to be programmed.

2.

Make parameter selection from menu (a beep and a green light indicates that the parameter has been scanned).

3.

Scan “ Start/End Program Menu.” This completes the operation and the new parameter is saved in memory.

The CCD reader is normally programmed as a keyboard wedge for IBM’s XT, AT, or PS/2 Models 50, 60, 70 and 80. If the host computer is not one of these models, refer to “Computer Type Selection” on page 18 to make another selection.

B

) A pointing finger indicates scanner NOTE: ( default settings.

Page 4

Page 9

Scanning If the scanner has a switch, depress button on underside to turn the scanner on. Red LED illumination will emit from the scan window. If the scanner does not have a trigger switch, then the LED’s will automatically remain on as long as the computer system is on. “good read” indicator scan window

NOTE: The scanner will not read any bar code label which is wider than the scan window. 1.

Approach, point or touch the bar code label with the scan window of the CCD scanner.

2.

Scan within a distance of 0 to 1.0" (2.3" window); 0 to 2.5" (3.2" window) from the bar code label.

3.

Center the CCD scan window on bar code label for fastest read.

4.

The scanner will beep to indicate an audible good read * (if beeper has not been turned off by a menu option).

5.

A green LED indicator will visually signal a good read.

*

The scanner reads all bar code symbologies listed in the menu section of this manual.

Page 5

Page 10

User Maintenance Cleaning the scan window is the only maintenance that is required. ♦

Do not allow any abrasive material to touch the window.

♦

Remove any dirt particles with a damp cloth.

♦

Clean the scan window using a soft cloth or a cotton tipped swab moistened with water.

♦

Do not remove the nose of the scanner.

Page 6