Page 41

OPTICON UNIVERSAL MENU BOOK

SET

_ZZ_

S-Code only

RA

_RA_

Matrix 2of5 only

AB

_AB_

Chinese Post Matrix 2of5 only

JE

_JE_

Korean Postal Authority code only

JL

_JL_

IATA only

A4

_A4_

MSI/Plessey only

A7

_A7_

Telepen only

A9

_A9_

UK/Plessey only

A1

_A1_

Code 128 only

A6

_A6_

Code 93 only

A5

_A5_

Code 11 only

BLB

_BLB_

RSS-14 only

J9

_J9_

RSS-limited only

JJ

_JJ_

END

_ZZ_ U36

Page 42

OPTICON UNIVERSAL MENU BOOK

_ZZ_

RSS-expanded only

JK

_JK_

DataMatrix ECC000 140 only

BG2

_BG2_

DataMatrix ECC200 only

BC0

_BC0_

Aztec only

BC5

_BC5_

Aztec runes only

BF4

_BF4_

QR Code only

BC1

_BC1_

Micro QR Code only

D38

_D38_

Maxicode only

BC2

_BC2_

PDF417 only

BC3

_BC3_

MicroPDF417 only

BC4

_BC4_

Enable all 1D codes only

BCA

_BCA_

Enable all 2D codes only

BCB

_BCB_

END

_ZZ_

U37

3 Code options

SET

Page 43

OPTICON UNIVERSAL MENU BOOK

3.1.2. Enabling of readable codes With this option you can set the reader to read a number of bar code types or simply enable additional bar code types. Example: If you only want to read Code 39 and Code 128, you read 'Code 39 only' and 'enable Code 128'. Alternatively you can read 'Disable All', 'Enable Code 39' and 'Enable Code 128'. See figure 3.04.

Fig. 3.04. Enabling of readable codes

SET

SET

Code 39 only

Disable All

Enable Code 128

Enable Code 39

END

Enable Code 128 END

Example: If you want to enable Codabar in addition to what you already have configured, you read 'Enable Codabar'. See figure 3.05.

Fig. 3.05. Enabling of readable codes addition

SET Enable Codabar END

U38

Page 44

OPTICON UNIVERSAL MENU BOOK

3.1.2. Enabling of readable codes

_ZZ_

All codes excl. add-on

A0

_A0_

Enable UPC

R1

_R1_

Enable UPC + 2

R2

_R2_

Enable UPC + 5

R3

_R3_

Enable EAN

R4

_R4_

Enable EAN + 2

R5

_R5_

Enable EAN + 5

R6

_R6_

Enable Code 39

B2

_B2_

Enable Tri-Optic

JZ

_JZ_

Enable Codabar

B3

_B3_

Enable Industrial 2of5

R7

_R7_

Enable Interleaved 2of5

R8

_R8_

Enable S-Code

R9

_R9_

END

_ZZ_ U39

3 Code options

SET

Page 45

OPTICON UNIVERSAL MENU BOOK

SET

_ZZ_

Enable Matrix 2of5

BB

_BB_

Enable Chinese Post Matrix 2of5

JS

_JS_

Enable Korean Postal Authority code

WH

_WH_

Enable IATA

B4

_B4_

Enable MSI/Plessey

B7

_B7_

Enable Telepen

B9

_B9_

Enable UK/Plessey

B1

_B1_

Enable Code 128

B6

_B6_

Enable Code 93

B5

_B5_

Enable Code 11

BLC

_BLC_

Enable RSS-14

JX

_JX_

Enable RSS-limited

JY

_JY_

Enable RSS-expanded

DR

_DR_

END

_ZZ_ U40

Page 46

OPTICON UNIVERSAL MENU BOOK

_ZZ_

Enable DataMatrix ECC000 - 140

BG0

_BG0_

Enable DataMatrix ECC200

BCC

_BCC_

Enable Aztec

BCH

_BCH_

Enable Aztec runes

BF2

_BF2_

Enable QR Code

BCD

_BCD_

Enable Micro QR Code

D2U

_D2U_

Enable Maxicode

BCE

_BCE_

Enable PDF417

BCF

_BCF_

Enable MicroPDF417

BCG

_BCG_

Enable all 1D codes

BCM

_BCM_

Enable all 2D codes

BCN

_BCN_

Disable all

B0

_B0_

END

_ZZ_

U41

3 Code options

SET

Page 47

OPTICON UNIVERSAL MENU BOOK

3.2. Setting of number of characters Fig. 3.06. Setting Fixed length ON all codes

If you are going to read bar codes of known length, it is recommended to set the reader for a fixed number of characters. This can be done for up to two lengths. The reader uses this to verify that labels read are of the correct length, rejecting any labels which do not have the specified length. The advantage of setting a fixed length, is that it provides protection against short scans of labels, such as Interleaved 2of5, which do not provide sufficient security against partial scan. The length checking is done on the label data and is not affected by options such as (not) transmit start/ stop character or check digit. Setting the number of characters does not affect fixed length codes, such as EAN-13. 2D symbologies such as PDF417 and Data Matrix are also not affected by fixed length settings.

SET Fixed length ON Scan a bar code with the required length Scan a 2nd bar code with the required length END

It is possible to configure a fixed length or a minimum and a maximum length for selected symbologies by reading the respective option followed by a barcode label with the required length. The different functions may be combined and will be used as follows:

The following options are available: Fixed length OFF all codes. This option cancels the fixed length checking.

• if a label is checked for fixed length, it will not be checked for minimum or maximum length • if a label is not checked for fixed length it will be checked for both minimum and maximum length By reading an option followed by the 'END' label, the function is disabled or the values for that option are reset to their default. The default values are: • fixed: disabled, thus no fixed length checking • minimum: according to the next figure (The minimum length of the 2of5 bar code types can not be changed independent.) • maximum: disabled, thus no maximum length checking. (The maximum length is reader dependent) See figure 3.07.

Fixed length ON all codes. This option enables the fixed length checking. Two fixed lengths are programmed which will affect all variable length codes. This is done by reading the following labels: <SET> <Fixed length ON - all codes> a bar code with the required length, a second bar code with the required length (this may be the same one as the first one) <END> See figure 3.06.

U42

Page 48

OPTICON UNIVERSAL MENU BOOK characters and Interleaved 2of5 labels for a length of 12 characters. This implies that also Industrial 2of5, Matrix 2of5 and S-Code are checked for a fixed length of 12 characters. Any other bar code type will not be checked for fixed length. See figure 3.08.

Fig. 3.07. Setting Minimum length table Code type:

Minimum length

Codabar

5

Code 11

1

Code 39

1

Code 93

1 1

Industrial 2of5

5

Interleaved 2of5

6

IATA

5

Matrix 2of5

5

MSI/Plessey

3

UK/Plessey

2

RSS-expanded

1

S-Code

5

Telepen

1

SET

SET

Fixed length ON for selected only

Fixed length ON for selected only

Scan a label, i.e. Code 39 with length = 6

Scan a label, i.e. Code 39 with length = 6

END

Scan a label, i.e. Interleaved 2of5 with length = 12 END

Minimum length for selected codes: This option modifies the default minimum length table. The number of minimum lengths which can be configured is reader dependent. This is done by reading the following labels: <SET> <Minimum length for selected codes> Scan bar codes of the required type and length <END>

Fixed length ON for selected codes: This option enables fixed length checking for different bar code types and will only affects the bar code types read. The number of fixed lengths which can be configured is reader dependent.

Example: The two examples shown in the next figure have the following result: In the first example only Code 39 labels will be checked for a minimum length of 2 characters. All other bar code types will be checked for a minimum length as displayed in the next figure. In the second example Code 39 labels will be checked for a minimum length of 2 characters and Interleaved 2of5 labels for a minimum length of 4 characters. This implies that also Industrial 2of5, Matrix 2of5 and S-Code are checked for a minimum length of 4 characters. All other bar code types will be checked for a minimum length as per figure 3.09.

<SET> <Fixed length ON for selected codes> Scan bar codes of the required type and length <END> Example: The 2 examples shown in the next figure have the following results: In the first example only Code 39 labels will be checked for a length of 6 characters. Any other bar code type will not be checked for fixed length. In the second example Code 39 labels will be checked for a length of 6 U43

3 Code options

Code 128

Fig. 3.08. Setting Fixed length ON selected codes

Page 49

OPTICON UNIVERSAL MENU BOOK

Fig. 3.10. Setting Maximum length for selected codes

Fig. 3.09. Setting Minimum length for selected codes

SET

SET

SET

SET

Minimum length for selected codes

Minimum length for selected codes

Maximum length for selected codes

Maximum length for selected codes

Scan a label, i.e. Code 39 with length = 2

Scan a label, i.e. Code 39 with length = 2

Scan a label, i.e. Code 39 with length = 12

Scan a label, i.e. Code 39 with length = 12

END

Scan a label, i.e. Interleaved 2of5 with length = 4

END

Scan a label, i.e. Interleaved 2of5 with length = 14

END

END

Serial programming: To set a length using serial commands, the sequence is as follows: <ESC> <command> <SPACE>*<CodeID>* <Length 1> <Length 2> <CR> *(if required by <command>)

Maximum length for selected codes: This option enables the maximum length checking. The number of maximum lengths which can be configured is reader dependent. This is done by reading the following labels: <SET> <Maximum length for selected codes> Scan bar codes of the required type and length <END> Example: The two following examples shown in the next figure have the following result: In the first example only Code 39 labels will be checked for a maximum length of 12 characters. Any other bar code types will not be checked for a maximum length. In the second example Code 39 labels will be checked for a maximum length of 12 characters and Interleaved 2of5 labels for a maximum length of 14 characters. This implies that also Industrial 2of5, Matrix 2of5 and S-Code are checked for a maximum length of 14 characters. Any other bar code types will not be checked for a maximum length. See figure 3.10.

Example: Setting fixed length for all codes, lengths 8, 10 and 12: • <ESC>H1081012<CR> Setting minimum length for selected codes, for Code 39 with a length of 2: • <ESC>HL V02<CR> Setting maximum length for selected codes, for Code 39 with a length of 12 and Interleaved 2of5 with length of 14: • <ESC>HM V12 N14<CR>

U44

Page 50

OPTICON UNIVERSAL MENU BOOK

3.2. Setting of number of characters

_ZZ_

Fixed length OFF all codes

H0

_H0_

Fixed length ON all codes

H1

_H1_

Fixed length ON for selected codes

HK

_HK_

Minimum length for selected codes

HL

_HL_

Maximum length for selected codes

HM

_HM_

END

_ZZ_

U45

3 Code options

SET