Page 31
OPTICON UNIVERSAL MENU BOOK
2.3.4. Trigger disconnect options Press trigger switch time to disconnect: This is the time the trigger switch needs to be pressed where after the reader disconnects.
SET
_ZZ_
Disabled
PD00
_PD00_
1 second
PD01
_PD01_
2 seconds
PD02
_PD02_
3 seconds
PD03
_PD03_
4 seconds
PD04
_PD04_
5 seconds
PD05
_PD05_
6 seconds
PD06
_PD06_
7 seconds
PD07
_PD07_
8 seconds
PD08
_PD08_
9 seconds
PD09
_PD09_
END
_ZZ_
U26
Page 32
OPTICON UNIVERSAL MENU BOOK
2.3.5. Auto disconnect options Auto disconnect: If the reader is idle for the configured time, it will disconnect. Purpose options are power saving.
_ZZ_
Disabled
AD00
_AD00_
10 minutes
AD01
_AD01_
20 minutes
AD02
_AD02_
30 minutes
AD03
_AD03_
40 minutes
AD04
_AD04_
50 minutes
AD05
_AD05_
60 minutes
AD06
_AD06_
END
_ZZ_
U27
2 Interface
SET
Page 33
OPTICON UNIVERSAL MENU BOOK connection during the configured time. If this time is expired, the reader stops trying. The reader will not reconnect after reading the manually disconnect label or after auto disconnection.
2.3.6. Auto reconnect options Auto reconnect: If the reader is disconnected because it is out of range or the Bluetooth device is not available, the reader will try to establish the
SET
_ZZ_
Disabled
CA00
_CA00_
1 minute
CA01
_CA01_
2 minutes
CA02
_CA02_
3 minutes
CA03
_CA03_
4 minutes
CA04
_CA04_
5 minutes
CA05
_CA05_
6 minutes
CA06
_CA06_
7 minutes
CA07
_CA07_
8 minutes
CA08
_CA08_
9 minutes
CA09
_CA09_
END
_ZZ_
U28
Page 34
OPTICON UNIVERSAL MENU BOOK
IEEE 802.15.4 power saving IEEE 802.15.4 based readers change the antenna output power instead of changing the activity rate. See figure 2.08.
2.3.7. Wireless power saving Activation levels: In order to reduce the power consumption it is possible to set the activity rate of the reader. The default setting is ‘Active’, meaning that the reader will continuously check for communication. By setting the level to a certain time the reader will reduce activity and check for communication only at the set time.
Fig. 2.08. Power saving table -3 dBm -5 dBm -7 dBm -10 dBm -15 dBm -25 dBm
SET
_ZZ_
Level 0
LV00
_LV00_
Level 1 300 slots, 187.5ms
LV01
_LV01_
Level 2 500 slots, 312.5ms
LV02
_LV02_
Level 3 700 slots, 437.0ms
LV03
_LV03_
Level 4 900 slots, 562.5ms
LV04
_LV04_
Level 5 1100 slots, 687.5ms
LV05
_LV05_
Level 6 1300 slots, 812.5ms
LV06
_LV06_
Level 7 1500 slots, 937.5ms
LV07
_LV07_
END
_ZZ_ U29
Output power
2 Interface
Power level
Auto disconnect: Power consumption can also be reduced by auto disconnect settings as described in the chapters: Auto disconnect options and Auto reconnect options.
level 0 level 1 level 2 level 3 level 4 level 5
Page 35
OPTICON UNIVERSAL MENU BOOK
Clear all memorized data: All memorizing data is deleted and the storage area is cleared.
2.3.8. Memorizing Memorizing options can be used to temporary store bar code data in case the bar code reader lost its connection. As soon the reader is connected again, the temporary stored data is transmitted to the computer and the storage area is cleared. The data is stored in RAM. In case the battery is depleted or battery is removed, data is lost.
Transmit memorized data: All memorized data will be transmitted, if a connection is available. Available memory for memorizing is reader dependent ( 12kB )
The bar code reader is automatically disconnected in case: • the bar code reader is out of range ( too far away from cradle ), • power from cradle is lost. Data memorizing disabled: Bar code data is not stored automatically, in case the connection is lost. Data memorizing can manually be started by reading the Start/ continue memorizing option. Data memorizing enabled: Bar code data is stored automatically, in case the connection is lost. Memorize after connection loss: Data is only temporary stored in case the bar code reader lost its connection. Memorizing stops in case the +-DISC-+ label is read or in case the wireless address is changed. Always memorize when not connected: Data is always temporary stored in case the bar code reader is not connected. Memorize control labels: The next options should be used without reading the SET and END label. These memorizing options are intended to manually control the memorizing mode. Start/continue memorizing: Manually start memorizing. In case memorized data was present, it will continue memorizing. Stop/pause memorizing: Manually stop memorizing. Memorizing can be continued by reading the Start/continue memorizing option.
U30
Page 36
OPTICON UNIVERSAL MENU BOOK
2.3.8. Memorizing
_ZZ_
Data memorizing disabled
DTMD
_DTMD_
Data memorizing enabled
DTME
_DTME_
Memorize after connection loss
BM0
_BM0_
Always memorize when not connected
BM1
_BM1_
END
_ZZ_
Clear all memorized data
+-MCLR-+
_+-MCLR-+_
Start/continue memorizing
+-MSTR-+
_+-MSTR-+_
Stop/pause memorizing
+-MSTP-+
_+-MSTP-+_
Transmit memorized data
+-MXMT-+
_+-MXMT-+_
2.3.8. Memorizing commands
U31
2 Interface
SET
Page 37
OPTICON UNIVERSAL MENU BOOK
U32
Page 38
OPTICON UNIVERSAL MENU BOOK
3. CODE OPTIONS The menu options in this chapter are intended to select: • which bar code types can be read • the permissible length of the bar codes to be read • bar code specific options In short: the decoding characteristics of the reader can be adjusted.
3 Code options
U33
Page 39
OPTICON UNIVERSAL MENU BOOK
3.1.1. Enabling a single read. code
3.1. Setting of readable codes
With this option you can set the reader to read a single bar code type only. If you select 'Code 39 only', no other codes will be read.
These options do not affect the reading of the menu labels. The required bar code types can be selected by enabling a single readable code only and enabling readable codes.
Example: If you want to read Code 39 only, you read the option 'Code 39 only'. See figure 3.02.
It is strongly recommended to select only the required codes. Advantages of selecting only the required codes are:
Fig. 3.02. Enabling a single readable code: Code 39
• faster reading • no accidental scanning of unwanted bar codes • reduced probability of reading errors which can not be prevented completely, because of the limited security of some bar code types
SET Code 39 only
Some bar codes are translations or special variants of other bar code types. The next figure lists their relationships. See figure 3.01.
END
Example: To read Italian Pharmaceutical type bar codes, Enable Code 39, Select the option 'Italian Pharmaceutical' from the 'Options for Code 39'.
Example: If you want to read one of the special bar codes as listed in the relations table for setting of readable codes, e.g. EAN128 only, you read the option 'Code 128 only' followed by 'Enable EAN-128 only' from the 'Options for Code 128'. See figure 3.03.
Fig. 3.01. Setting of readable codes table RELATIONS Code type:
Belongs to:
ABC Code
Codabar
Code 39 Full ASCII
Code 39
CX Code
Codabar
EAN 128
Code 128
ISBN Bookland
EAN-13
ISSN
EAN-13
ISMN
EAN-13
Tri-Optic
Code 39
Fig. 3.03. Enabling a single readable code: Code 128
SET Code 128 only Enable EAN-128 only END
U34
Page 40
OPTICON UNIVERSAL MENU BOOK
3.1.1. Enabling a single read. code
_ZZ_
All codes excl. add-on
A0
_A0_
Only all UPC and EAN codes
J0
_J0_
UPC only
J1
_J1_
UPC + 2 only
J2
_J2_
UPC + 5 only
J3
_J3_
EAN only
J4
_J4_
EAN + 2 only
J5
_J5_
EAN + 5 only
J6
_J6_
Code 39 only
A2
_A2_
Tri-Optic only
JD
_JD_
Codabar only
A3
_A3_
Industrial 2of5 only
J7
_J7_
Interleaved 2of5 only
J8
_J8_
END
_ZZ_ U35
3 Code options
SET