Page 51

OPTICON UNIVERSAL MENU BOOK

Not transmit CD: This option disables the transmission of the check digit. If the check digit calculation is disabled, the reader can not differentiate between a (valid) check digit and a data character. It will therefore transmit all data characters of the label, excluding the character that could constitute the check digit for the type of bar code.

3.3. Setting code specific options Code specific options may be configured affecting: • enabling and disabling code variants and translations, such as EAN-128, as were listed in the relations table for setting of readable codes • data verification such as by means of a check digit calculation. A check digit has a value that can be calculated from the other data characters and is usually the last data character in a bar code • pre-editing of the data string such as removing the check-digit and/or start/stop characters

Transmit ST/SP: This option enables the transmission of the start and stop characters of a bar code. Not transmit ST/SP: This option disables the transmission of the start and stop characters of a bar code. The next figure summarizes the effect of the transmit options for a Code 39 label with: • start and stop characters '*' • data characters '1 2 3 4 5 6' • or data characters '1 2 3 4 5' and check digit '6'

The more common options are described here: Check CD: This option enables the check digit calculation. If the calculated check digit does not correspond to the check digit in the bar code, then the bar code is ignored. The use of a check digit greatly improves the security of a bar code.

Note that because '6' is, according to the Code 39 specifications, not a valid check digit for this label. The check digit calculation must therefore be disabled in order for the label to be accepted.

Not check CD: This option disables the check digit calculation. This option is required when the bar codes do not contain a check digit or contain an invalid check digit.

See figure 3.11.

Fig. 3.11. Setting code specific options

Transmit CD: This option enables the transmission of the check digit together with the data characters. If the check digit calculation is disabled, the reader can not differentiate anymore between a (valid) check digit and a data character. It will therefore transmit all data characters of the label, including what could constitute a check digit.

U46

Transmit CD

Not transmit CD

Transmit ST/SP

*123456*

*12345*

Not transmit ST/SP

123456

12345

Page 52

OPTICON UNIVERSAL MENU BOOK

3.3.1. Options for UPC-A The UPC-A symbology is a fixed length symbology encoding 11 data digits, a check digit and non printable start/stop characters. The following characters are supported: • the digits 0 up to 9

Fig. 3.12. Options for UPC-A UPC-A leading zero

An optional leading zero can be transmitted, which together with the data and the check digit forms a 13 digit field providing compatibility with the EAN-13 format. For string format see figure 3.12.

data (11 digits)

check digit

3

Fig. 3.13. Options for UPC-A

UPC-A add-on 2/add-on 5: The UPC-A symbology as described above can be succeeded by an additional 2 or 5 digit UPCA code. For string format see figure 3.13.

leading zero data (11 digits)

Options for UPC-A: • disable transmission of the leading zero • disable transmission of the check digit

SET

_ZZ_

UPC-A, No leading zero, transmit CD

E3

_E3_

UPC-A, No leading zero, not transmit CD

E5

_E5_

UPC-A, Leading zero, transmit CD

E2

_E2_

UPC-A, Leading zero, not transmit CD

E4

_E4_

END

_ZZ_

U47 check digit add-on 2 or 5

Code options

UPC-A +2, +5

Page 53

OPTICON UNIVERSAL MENU BOOK

3.3.2. Options for UPC-E The UPC-E symbology is a fixed length symbology encoding 6 data digits, a check digit and non printable start/stop characters. The following characters are supported: • the digits 0 upto 9

Fig. 3.14. Options for UPC-E UPC-E leading digit (0 or 1)

An optional leading digit can be transmitted, which together with the data and the check digit forms an 8 digit field providing a compatibility with the EAN-8 format. For string format see figure 3.14.

data (6 digits)

check digit

Fig. 3.15. Options for UPC-E UPC-E +2, +5

UPC-E add-on 2/add-on 5: The UPC-E symbology as described above can be succeeded by an additional 2 or 5 digit UPCE code. For string format see figure 3.15.

leading digit (0 or 1)

UPC-E0 stands for UPC version E0 and the first digit is always a '0'. UPC-E1 stand for UPC version E1 and the first digit is a '1'. Options for UPC-E0 affects UPC-E1 too. Support for UPCE1 is reader dependent. Options for UPC-E: • enable transmission of the leading digit • disable transmission of the check digit • transmit UPC-E as UPC-A Transmit UPC-E as UPC-A: If this option is enabled, a UPC-E label is transmitted in the UPC-A format.

U48 data (6 digits)

check digit add-on 2 or 5

Page 54

OPTICON UNIVERSAL MENU BOOK

3.3.2. Options for UPC-E

_ZZ_

UPC-E, No leading digit, transmit CD

E7

_E7_

UPC-E, No leading digit, not transmit CD

E9

_E9_

UPC-E, Leading digit, transmit CD

E6

_E6_

UPC-E, Leading digit, not transmit CD

E8

_E8_

Transmit UPC-E as is

6Q

_6Q_

Transmit UPC-E as UPCA

6P

_6P_

END

_ZZ_

U49

3 Code options

SET

Page 55

OPTICON UNIVERSAL MENU BOOK

3.3.3. Options for EAN-13 and EAN-8 EAN-13: The EAN-13 symbology is a fixed length symbology encoding 12 data digits, a check digit and non printable start/stop characters. The following characters are supported: • the digits 0 upto 9

Fig. 3.16. Options for EAN-13 and EAN-8 EAN-13 data (12 digits)

check digit

The data may be translated into ISBN, ISSN or ISMN format. For string format see figure 3.16.

Fig. 3.17. Options for EAN-13 and EAN-8

EAN-13 add-on 2/add-on 5: The EAN-13 symbology as described above can be succeeded by an additional 2 or 5 digit code. For string format see figure 3.17.

EAN-13, +2,+5 data (12 digits)

EAN-8: The EAN-8 symbology is a fixed length symbology encoding 7 data digits, a check digit and non printable start/stop characters. The following characters are supported: • the digits 0 upto 9 For string format see figure 3.18.

check digit add-on 2 or 5

Fig. 3.18. Options for EAN-13 and EAN-8 EAN-8 data (7 digits)

EAN-8 add-on 2/add-on 5: The EAN-8 symbology as described above can be succeeded by an additional 2 or 5 digit code. For string format see figure 3.19. Options for EAN: • disable transmission of the check digit • enable ISBN, ISSN or ISMN translation check digit

Fig. 3.19. Options for EAN-13 and EAN-8 EAN-8, +2,+5

Enable ISBN, ISSN or ISMN translation: If this option is enabled, an EAN-13 label is verified for the correct format and transmitted as a 10-digit ISBN number, 8 digit ISSN number. In case of ISMN, the character M is transmitted followed by 9 digits. Support for these translations is reader dependent.

data (7 digits)

U50 check digit add-on 2 or 5

Page 56

OPTICON UNIVERSAL MENU BOOK

3.3.3. Options for EAN-13 and EAN-8

_ZZ_

EAN-13 not transmit CD

6J

_6J_

EAN-13 transmit CD

6K

_6K_

EAN-8 not transmit CD

6H

_6H_

EAN-8 transmit CD

6I

_6I_

Disable ISBN translation

IB

_IB_

Enable ISBN translation

IA

_IA_

Enable ISBN if possible

IK

_IK_

Disable ISSN translation

HN

_HN_

Enable ISSN translation

HO

_HO_

Enable ISSN if possible

4V

_4V_

Disable ISMN translation

IO

_IO_

Enable ISMN translation

IP

_IP_

Enable ISMN if possible

IQ

_IQ_

END

_ZZ_ U51

3 Code options

SET

Page 57

OPTICON UNIVERSAL MENU BOOK

Italian Pharmaceutical only: In this mode the decoded data characters are translated to the Italian Pharmaceutical format. If the data does not comply with the Italian Pharmaceutical format, the label is rejected.

3.3.4. Options for Code 39 and It. Pharm. Code 39: Code 39 is a variable length symbology with an optional check digit and printable start/stop characters. The following characters are supported: • the digits 0 up to 9 • the upper case characters A up to Z • the characters - . $ / + % SPACE • start/stop character is *

Italian Pharmaceutical if possible: In this mode the decoded data characters are translated to the Italian Pharmaceutical format. If the data does not comply with the Italian Pharmaceutical format, then the data is transmitted as Normal or full ASCII Code 39.

The checksum is calculated as the sum modulo 43 of the numerical value of the data characters. In full ASCII mode, all 128 ASCII characters are supported. This is done by combining one of the characters +, %, $ or / with one of the alpha characters (A upto Z). For string format see figure 3.20.

Concatenation: If a Code 39 bar code contains a leading space, the data is stored into the reader's buffer without the leading space. As soon as a Code 39 bar code is read without a leading space, the data is appended to the reader's buffer and the entire buffer is transmitted and cleared for new data. In case a non Code 39 bar code is read, the data in the non-Code 39 bar code is transmitted and the buffer is cleared. The buffer size is reader dependent.

Italian Pharmaceutical: In this mode the Code 39 data is translated to the Italian pharmaceutical format. This format has a fixed length containing 8 numeric data values followed by a single mandatory check digit. An optional leading 'A' can be transmitted. For string format see figure 3.21. Options for Code 39: • enable full ASCII conversion • enable Italian Pharmaceutical conversion • enable check digit • disable transmission of the check digit • enable transmission of start/stop • enable leading A for Italian Pharmaceutical • selection of the minimum number of data characters

Fig. 3.20. Options for Code 39 and It.Pharm. Code 39 start char.

Normal Code 39: In this mode the decoded data characters are transmitted without further translation.

data (0 or more char.)

check digit stop char.

Fig. 3.21. Options for Code 39 and It.Pharm. Italian Pharmaceutical

Full ASCII Code 39: In this mode the decoded data characters are translated to full ASCII Code 39.

start char.

Full ASCII Code 39 if possible: In this mode the decoded data characters are translated to full ASCII Code 39. Invalid combinations are not translated and are transmitted as is.

U52 leading A data (8 digits)

check stop digit char.

Page 58

OPTICON UNIVERSAL MENU BOOK

3.3.4. Options for Code 39 and It.Pharm.

_ZZ_

Normal Code 39

D5

_D5_

Full ASCII Code 39

D4

_D4_

Full ASCII Code 39 if possible

+K

_+K_

It. Pharmaceutical only

D6

_D6_

It. Pharmaceutical if possible

D7

_D7_

Not check CD

C1

_C1_

Check CD

C0

_C0_

Not transmit CD

D8

_D8_

Transmit CD

D9

_D9_

Not transmit ST/SP

D1

_D1_

Transmit ST/SP

D0

_D0_

Not transm. ld. A for It. Pharm.Code

DA

_DA_

Transmit leading A for It. Pharm.Code

DB

_DB_

END

_ZZ_ U53

3 Code options

SET

Page 59

OPTICON UNIVERSAL MENU BOOK

SET

_ZZ_

Minimum 3 digits

8D

_8D_

Minimum 1 digit

8E

_8E_

Disable concatenation

+M

_+M_

Enable concatenation

+L

_+L_

END

_ZZ_

U54

Page 60

OPTICON UNIVERSAL MENU BOOK

3.3.5. Options for Codabar Codabar (NW7): Codabar (NW7) is a variable length symbology with an optional check digit and printable start/ stop characters. The next characters are supported: • the digits 0 upto 9 • the characters - $: / . + • start/stop characters are A, B, C or D The checksum is calculated as the sum modulo 16 of the numerical values of all data characters. For string format see figure 3.22.

Fig. 3.23. Options for Codabar ABC Code start char.

Fig. 3.24. Options for Codabar CX Code start char.

CX-Code: The CX-Code consists of two bar codes which are decoded in one read cycle. The code is concatenated when the stop character of the first bar code is a C, and the start character of the second bar code is a B. The B and C characters are not transmitted. For string format see figure 3.24. Options for Codabar: • enable ABC code concatenation • enable CX code concatenation • enable check digit check • disable transmission of the check digit • disable transmission of start/stop • selection of start/stop character translation • selection of minimum number of data characters • enable library space (CLSI) insertion

Fig. 3.22. Options for Codabar Codabar data (1 or more char.)

check digit stop char.

U55 data (1 or check data (1 or check stop more char.) digit more char.) digit char.

3 Code options

ABC-Code: The ABC code is an acronym for American Blood Commission. This code consists of two bar codes which are decoded in one read cycle. The code is concatenated when the stop character of the first bar code and the start character of the second bar code is a D. These two D's are not transmitted. For string format see figure 3.23.

start char.

data (1 or check data (1 or check stop more char.) digit more char.) digit char.