The text of a manual · part 6 of 15
Opticon Universal Menu Book: bar code configuration and commands manual, pages 51 to 60
Pages 51 to 60 of 147
The original document is the PDF (593 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Opticon LG-K1WE5SP, Opticon 25-WEDGE-06 and Opticon HLT-1120 ELT-1120
Page 51
OPTICON UNIVERSAL MENU BOOK
Not transmit CD: This option disables the transmission of the check digit. If the check digit calculation is disabled, the reader can not differentiate between a (valid) check digit and a data character. It will therefore transmit all data characters of the label, excluding the character that could constitute the check digit for the type of bar code.
3.3. Setting code specific options Code specific options may be configured affecting: • enabling and disabling code variants and translations, such as EAN-128, as were listed in the relations table for setting of readable codes • data verification such as by means of a check digit calculation. A check digit has a value that can be calculated from the other data characters and is usually the last data character in a bar code • pre-editing of the data string such as removing the check-digit and/or start/stop characters
Transmit ST/SP: This option enables the transmission of the start and stop characters of a bar code. Not transmit ST/SP: This option disables the transmission of the start and stop characters of a bar code. The next figure summarizes the effect of the transmit options for a Code 39 label with: • start and stop characters '*' • data characters '1 2 3 4 5 6' • or data characters '1 2 3 4 5' and check digit '6'
The more common options are described here: Check CD: This option enables the check digit calculation. If the calculated check digit does not correspond to the check digit in the bar code, then the bar code is ignored. The use of a check digit greatly improves the security of a bar code.
Note that because '6' is, according to the Code 39 specifications, not a valid check digit for this label. The check digit calculation must therefore be disabled in order for the label to be accepted.
Not check CD: This option disables the check digit calculation. This option is required when the bar codes do not contain a check digit or contain an invalid check digit.
See figure 3.11.
Fig. 3.11. Setting code specific options
Transmit CD: This option enables the transmission of the check digit together with the data characters. If the check digit calculation is disabled, the reader can not differentiate anymore between a (valid) check digit and a data character. It will therefore transmit all data characters of the label, including what could constitute a check digit.
U46
Transmit CD
Not transmit CD
Transmit ST/SP
*123456*
*12345*
Not transmit ST/SP
123456
12345
Page 52
OPTICON UNIVERSAL MENU BOOK
3.3.1. Options for UPC-A The UPC-A symbology is a fixed length symbology encoding 11 data digits, a check digit and non printable start/stop characters. The following characters are supported: • the digits 0 up to 9
Fig. 3.12. Options for UPC-A UPC-A leading zero
An optional leading zero can be transmitted, which together with the data and the check digit forms a 13 digit field providing compatibility with the EAN-13 format. For string format see figure 3.12.
data (11 digits)
check digit
3
Fig. 3.13. Options for UPC-A
UPC-A add-on 2/add-on 5: The UPC-A symbology as described above can be succeeded by an additional 2 or 5 digit UPCA code. For string format see figure 3.13.
leading zero data (11 digits)
Options for UPC-A: • disable transmission of the leading zero • disable transmission of the check digit
SET
_ZZ_
UPC-A, No leading zero, transmit CD
E3
_E3_
UPC-A, No leading zero, not transmit CD
E5
_E5_
UPC-A, Leading zero, transmit CD
E2
_E2_
UPC-A, Leading zero, not transmit CD
E4
_E4_
END
_ZZ_
U47 check digit add-on 2 or 5
Code options
UPC-A +2, +5
Page 53
OPTICON UNIVERSAL MENU BOOK
3.3.2. Options for UPC-E The UPC-E symbology is a fixed length symbology encoding 6 data digits, a check digit and non printable start/stop characters. The following characters are supported: • the digits 0 upto 9
Fig. 3.14. Options for UPC-E UPC-E leading digit (0 or 1)
An optional leading digit can be transmitted, which together with the data and the check digit forms an 8 digit field providing a compatibility with the EAN-8 format. For string format see figure 3.14.
data (6 digits)
check digit
Fig. 3.15. Options for UPC-E UPC-E +2, +5
UPC-E add-on 2/add-on 5: The UPC-E symbology as described above can be succeeded by an additional 2 or 5 digit UPCE code. For string format see figure 3.15.
leading digit (0 or 1)
UPC-E0 stands for UPC version E0 and the first digit is always a '0'. UPC-E1 stand for UPC version E1 and the first digit is a '1'. Options for UPC-E0 affects UPC-E1 too. Support for UPCE1 is reader dependent. Options for UPC-E: • enable transmission of the leading digit • disable transmission of the check digit • transmit UPC-E as UPC-A Transmit UPC-E as UPC-A: If this option is enabled, a UPC-E label is transmitted in the UPC-A format.
U48 data (6 digits)
check digit add-on 2 or 5
Page 54
OPTICON UNIVERSAL MENU BOOK
3.3.2. Options for UPC-E
_ZZ_
UPC-E, No leading digit, transmit CD
E7
_E7_
UPC-E, No leading digit, not transmit CD
E9
_E9_
UPC-E, Leading digit, transmit CD
E6
_E6_
UPC-E, Leading digit, not transmit CD
E8
_E8_
Transmit UPC-E as is
6Q
_6Q_
Transmit UPC-E as UPCA
6P
_6P_
END
_ZZ_
U49
3 Code options
SET
Page 55
OPTICON UNIVERSAL MENU BOOK
3.3.3. Options for EAN-13 and EAN-8 EAN-13: The EAN-13 symbology is a fixed length symbology encoding 12 data digits, a check digit and non printable start/stop characters. The following characters are supported: • the digits 0 upto 9
Fig. 3.16. Options for EAN-13 and EAN-8 EAN-13 data (12 digits)
check digit
The data may be translated into ISBN, ISSN or ISMN format. For string format see figure 3.16.
Fig. 3.17. Options for EAN-13 and EAN-8
EAN-13 add-on 2/add-on 5: The EAN-13 symbology as described above can be succeeded by an additional 2 or 5 digit code. For string format see figure 3.17.
EAN-13, +2,+5 data (12 digits)
EAN-8: The EAN-8 symbology is a fixed length symbology encoding 7 data digits, a check digit and non printable start/stop characters. The following characters are supported: • the digits 0 upto 9 For string format see figure 3.18.
check digit add-on 2 or 5
Fig. 3.18. Options for EAN-13 and EAN-8 EAN-8 data (7 digits)
EAN-8 add-on 2/add-on 5: The EAN-8 symbology as described above can be succeeded by an additional 2 or 5 digit code. For string format see figure 3.19. Options for EAN: • disable transmission of the check digit • enable ISBN, ISSN or ISMN translation check digit
Fig. 3.19. Options for EAN-13 and EAN-8 EAN-8, +2,+5
Enable ISBN, ISSN or ISMN translation: If this option is enabled, an EAN-13 label is verified for the correct format and transmitted as a 10-digit ISBN number, 8 digit ISSN number. In case of ISMN, the character M is transmitted followed by 9 digits. Support for these translations is reader dependent.
data (7 digits)
U50 check digit add-on 2 or 5
Page 56
OPTICON UNIVERSAL MENU BOOK
3.3.3. Options for EAN-13 and EAN-8
_ZZ_
EAN-13 not transmit CD
6J
_6J_
EAN-13 transmit CD
6K
_6K_
EAN-8 not transmit CD
6H
_6H_
EAN-8 transmit CD
6I
_6I_
Disable ISBN translation
IB
_IB_
Enable ISBN translation
IA
_IA_
Enable ISBN if possible
IK
_IK_
Disable ISSN translation
HN
_HN_
Enable ISSN translation
HO
_HO_
Enable ISSN if possible
4V
_4V_
Disable ISMN translation
IO
_IO_
Enable ISMN translation
IP
_IP_
Enable ISMN if possible
IQ
_IQ_
END
_ZZ_ U51
3 Code options
SET
Page 57
OPTICON UNIVERSAL MENU BOOK
Italian Pharmaceutical only: In this mode the decoded data characters are translated to the Italian Pharmaceutical format. If the data does not comply with the Italian Pharmaceutical format, the label is rejected.
3.3.4. Options for Code 39 and It. Pharm. Code 39: Code 39 is a variable length symbology with an optional check digit and printable start/stop characters. The following characters are supported: • the digits 0 up to 9 • the upper case characters A up to Z • the characters - . $ / + % SPACE • start/stop character is *
Italian Pharmaceutical if possible: In this mode the decoded data characters are translated to the Italian Pharmaceutical format. If the data does not comply with the Italian Pharmaceutical format, then the data is transmitted as Normal or full ASCII Code 39.
The checksum is calculated as the sum modulo 43 of the numerical value of the data characters. In full ASCII mode, all 128 ASCII characters are supported. This is done by combining one of the characters +, %, $ or / with one of the alpha characters (A upto Z). For string format see figure 3.20.
Concatenation: If a Code 39 bar code contains a leading space, the data is stored into the reader's buffer without the leading space. As soon as a Code 39 bar code is read without a leading space, the data is appended to the reader's buffer and the entire buffer is transmitted and cleared for new data. In case a non Code 39 bar code is read, the data in the non-Code 39 bar code is transmitted and the buffer is cleared. The buffer size is reader dependent.
Italian Pharmaceutical: In this mode the Code 39 data is translated to the Italian pharmaceutical format. This format has a fixed length containing 8 numeric data values followed by a single mandatory check digit. An optional leading 'A' can be transmitted. For string format see figure 3.21. Options for Code 39: • enable full ASCII conversion • enable Italian Pharmaceutical conversion • enable check digit • disable transmission of the check digit • enable transmission of start/stop • enable leading A for Italian Pharmaceutical • selection of the minimum number of data characters
Fig. 3.20. Options for Code 39 and It.Pharm. Code 39 start char.
Normal Code 39: In this mode the decoded data characters are transmitted without further translation.
data (0 or more char.)
check digit stop char.
Fig. 3.21. Options for Code 39 and It.Pharm. Italian Pharmaceutical
Full ASCII Code 39: In this mode the decoded data characters are translated to full ASCII Code 39.
start char.
Full ASCII Code 39 if possible: In this mode the decoded data characters are translated to full ASCII Code 39. Invalid combinations are not translated and are transmitted as is.
U52 leading A data (8 digits)
check stop digit char.
Page 58
OPTICON UNIVERSAL MENU BOOK
3.3.4. Options for Code 39 and It.Pharm.
_ZZ_
Normal Code 39
D5
_D5_
Full ASCII Code 39
D4
_D4_
Full ASCII Code 39 if possible
+K
_+K_
It. Pharmaceutical only
D6
_D6_
It. Pharmaceutical if possible
D7
_D7_
Not check CD
C1
_C1_
Check CD
C0
_C0_
Not transmit CD
D8
_D8_
Transmit CD
D9
_D9_
Not transmit ST/SP
D1
_D1_
Transmit ST/SP
D0
_D0_
Not transm. ld. A for It. Pharm.Code
DA
_DA_
Transmit leading A for It. Pharm.Code
DB
_DB_
END
_ZZ_ U53
3 Code options
SET
Page 59
OPTICON UNIVERSAL MENU BOOK
SET
_ZZ_
Minimum 3 digits
8D
_8D_
Minimum 1 digit
8E
_8E_
Disable concatenation
+M
_+M_
Enable concatenation
+L
_+L_
END
_ZZ_
U54
Page 60
OPTICON UNIVERSAL MENU BOOK
3.3.5. Options for Codabar Codabar (NW7): Codabar (NW7) is a variable length symbology with an optional check digit and printable start/ stop characters. The next characters are supported: • the digits 0 upto 9 • the characters - $: / . + • start/stop characters are A, B, C or D The checksum is calculated as the sum modulo 16 of the numerical values of all data characters. For string format see figure 3.22.
Fig. 3.23. Options for Codabar ABC Code start char.
Fig. 3.24. Options for Codabar CX Code start char.
CX-Code: The CX-Code consists of two bar codes which are decoded in one read cycle. The code is concatenated when the stop character of the first bar code is a C, and the start character of the second bar code is a B. The B and C characters are not transmitted. For string format see figure 3.24. Options for Codabar: • enable ABC code concatenation • enable CX code concatenation • enable check digit check • disable transmission of the check digit • disable transmission of start/stop • selection of start/stop character translation • selection of minimum number of data characters • enable library space (CLSI) insertion
Fig. 3.22. Options for Codabar Codabar data (1 or more char.)
check digit stop char.
U55 data (1 or check data (1 or check stop more char.) digit more char.) digit char.
3 Code options
ABC-Code: The ABC code is an acronym for American Blood Commission. This code consists of two bar codes which are decoded in one read cycle. The code is concatenated when the stop character of the first bar code and the start character of the second bar code is a D. These two D's are not transmitted. For string format see figure 3.23.
start char.
data (1 or check data (1 or check stop more char.) digit more char.) digit char.