Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a spec sheet · part 2 of 2

Bar Code Reader V550-A20: Fixed Position Bar Code Reader with Integrated Decoder, pages 11 to 20

Pages 11 to 20 of 20

The original document is the PDF (390 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Omron V550-A20

Page 11

V550-A20

V550-A20

■ SYSMAC SERIES C200HS OR C200H ALPHA WITH RS-232 CONNECTION: 2

7

1

6

3

5

4

1

CPU unit

C200HS-CPU21

2

Communicatons board

C200HW-COM04, C200HW-COM05

3

Bar code reader

V550-A20

4

Connecting cable

V559-A32A-2M

5

Power supply

S82S-0305 (5V, 0.6A) (see note)

6

Programming console

C200H-PRO27

7

Trigger switch

Note: Not rated for UL Class II operation.

■ OPERATION

■ CONFIRMATION OF OPERATION

Switch ON trigger switch 7 shown above to execute V550-A20 to read and send data to the data memory area of C200o. Use the program console 6 to confirm the data. In the event the data was not read, press "?" after the trigger switch is OFF.

• After programming, set RUN mode and set the trigger switch ON to execute the reading with the LED on the BCR lighting.

■ V550-A20 SETUP • Communication condition (setup): Baud rate: 9600 bps Word length: 7 bit Parity: EVEN Stop bit: 2 bit • Trigger Requirements: Start code: S Stop code: E Data output mode: Single output Scan trigger type: Serially controlled Trigger stage: Standard

■ C200HS OR C200Hα SETUP

• Press the key in the order below in order to confirm the data with the console: 1 CLEAR ➝ 2 FUN ➝ 3 MONITOR • The "?" is indicated, in the event that the data can't be read until the trigger switch is OFF.

■ C200HS OR C200Hα PROGRAMMING 00000 00000

00003

00101

26405

• Communication condition: Set OFF dip switch 5 of C200HS or C200Hα and set [1000] on DM6645 to match the communication condition with BCR (refer to the Reference Manual for the detailed way to change the condition). • Setting of Start code and Stop code: Set [2000] on DM6648. • On the DM, set the ASCII code [S] to Start Reading and [E] to Stop Reading.

00102 00007

• Connection of trigger switch: Connect the trigger switch to the input port [00000] terminal on the CPU unit to be able to send [S] or [E] through the RS-232C line when the BCR is ON or OFF, respectively. • Save the received data from the BCR in the order from upper digit, DM0200 must be the top, to down.

26406 00010

26405

DIFU(13)00101

Trigger switch ON (DIFFERENTIATE UP on rising pulse)

DIFD(14)00102

Trigger switch OFF (DIFFERENTIATE DOWN on falling pulse)

TXD(48) DM0100 #0000 #0001

Send 1 byte of DM0100 [Set to 5300] (S: send command to start reading)

BSET(71) #0000 DM0200 DM0220

DM0200-DM0220 clear (assume 20 readable digits)

TXD(48) DM0101 #0000 #0001

Send 1 byte of DM0101 [Set to 4500] (E: send command to stop reading)

RXD(47) DM0200 #0000 265

Store data from DM0200 buffer

MSG(46) DM0200

Indicate 16 levels of DM0200 to programmable controller

11

Page 12

V550-A20

V550-A20

PLC Master/Slave System ■ SYSMAC SERIES C200Hα. . . RS-485 MULTIDROP 1

2

3

PROTOCAL CONVERTER RS-232 to RS-485 4

1

CPU

C200H . . .

2

Bar code reader

V550-A20

3

Power supply unit

S825-0305 (5V, 0.6A) (see note)

4

Communications board

C200HW-COM04, C200HW-COM05

Note: Each bar code reader requires a minimum of 500 mA to operate. If your system contains more than 1 bar code reader in parallel, select a power supply rated for a higher output current.

■ CONNECTION WITH MULTIPLE READERS: Up to 32 slaves can be connected for each serial port on the master (depending upon line length and required response time). • Operation: The master device, C200H . . ., sends poll messages to the slave BCRs requesting them to respond with data. THe BCRs respond to the polls. There is no response if they are not polled by the master. • Message formats: V550-A20 Communication setting Basic setting

READ trigger

Level trigger

Read mode

Single

Communication

Baud rate

9600 bps

Condition

Word length

7 bit

(default)

Parity

EVEN

12

Stop bit

2 bit

Header

STX

Framing for all messages sent by any device on the multipdrop line: FF, STX, ID, TYPE, SEQ, DATA, LRC, CR. Code

Description

Notes

FF (hex)

Guard character

Ignored by receiver

STX (02hex)

Start of text character

Indicates start of a message

ID (2 ASCII digits

Unit identifier

Indicates BCR identification number

TYPE (2 ASCII digits)

Message type

Describes purpose of the message

SEQ

Sequence number

Starts at 0 at power up; incremented by 1 for each data message sent

DATA

Content of data field

May or may not contain characters

Linear redundancy check

Checks to ensure that message is valid

Carriage return

Indicates end of message

Footer

CR

LRC (2 ASCII digits)

RS/CS Control

OFF

CR

Page 13

V550-A20

V550-A20

■ C200Hα COMMUNICATIONS BOARD CONNECTIONS: The connections from the bar code reader connectors to the C200Hα COM board are shown below. V550-A20 Bar Code Reader

RS-485

SD+/RD+

6

SD-/RD-

8

SD+/RD+

6

SD-/RD-

8

(–) (+)

PROTOCAL CONVERTER

V550 pin configuration

6

SD-/RD-

8

6

5

9

C200Halpha COM board pinout

RS-232 SD+/RD+

1

C200H COM BOARD

Note: The above connection is shown using the C200Hα PLC with protocol macro function. Contact Omron for the latest V550-A20 protocol macro.

Dimensions Unit: mm (inch)

■ READERS AND ACCESSORIES V550-A20 Bar Code Reader

60 (2.36) 70 (2.76) FRONT OF SCANNER

63° BEAM PATH

30 (1.18)

OPTIONAL RIGHT ANGLE EXIT ATTACHMENT V559-A24

S82S-0305 Power Supply 37.5 (1.48) 6.5 (2.56) 9.8 (0.38)

4 (0.16)

6.1 (2.40) 3.5 (1.38)

7.5 (2.95)

Six, M3, 5

7.3 (0.29)

13

Page 14

V550-A20

V550-A20

Unit: mm (inch) V559-A25C Programming Kit BACKSHELL

BACKSHELL DE-9 FEMALE CONNECTOR

2000 (78.74)

DE-15 FEMALE CONNECTOR PVC JACKETED 6

1

V559-A25C

11

1 6

UL CLASS II, 5 V DC OUT, 120 V AC IN POWER SUPPLY

1825 (71.85)

V559-A32A-oM BCR to OMRON PLC RS-232 Port Cable BACKSHELL

BACKSHELL

L

DE-9 MALE CONNECTOR

DE-15 FEMALE CONNECTOR PVC JACKETED

V559-A32A

11

1 6

6

1 15: Brown (Red) 11: Blue (Black)

15

11

REFERENCE COLOR CODE

L 5 (0.20)

NOTE: L = 2 METERS (78.7 IN) OR 5 METERS (196.8 IN) 25 (0.98)

10 (0.39)

V559-A32B Programming Cable BACKSHELL

2000 (78.74)

BACKSHELL

DE-9 FEMALE CONNECTOR

DE-15 FEMALE CONNECTOR PVC JACKETED

V559-A32B

11

1 6

15: Brown (Red) 11: Blue (Black)

6

1 15

11

REFERENCE COLOR CODE 5 (0.20)

2000 (78.74) 25 (0.98)

14

10 (0.39)

Page 15

V550-A20

V550-A20

Unit: mm (inch)

■ MOUNTING BRACKETS V559-A26F Mounting Clip

V559-A26A Mounting Plate 0.156 x 0.281 SLOT

7.36 (0.29)

0.156 x 0.281 SLOT 4 PL

62.23 (2.45) 8.63 (0.34)

PEM FH-632-6

19.1 (0.75)

50.01 (1.97) 37.34 (1.47)

24.64 (0.97)

9.7 (0.38)

27.94 (1.10)

25.15 (0.99) 11.18 (0.44)

6.35 (0.25)

7.1 (0.28)

1.52 (0.06) 8.13 (0.32) 18.3 (0.72)

72.14 (2.84) 86.87 (3.42)

5.3 (0.21) 2.3 (0.09)

3.0 (0.12)

62.23 (2.45) 3.30 (0.13)

6.86 (0.27) 2.29 (0.09)

15

Page 16

V550-A20

V550-A20

Unit: mm (inch) V559-A26D Picket Fence Mounting Bracket

V559-A26E Ladder Mounting Bracket

0.156 x 0.281 2 PL

19.05 (0.75)

0.156 x 0.281 2 PL

19.05 (0.75)

9.65 (0.38)

9.65 (0.38)

6.35 (0.25)

6.35 (0.25)

76.20 (3.0)

57.15 (2.25)

69.85 (2.75)

88.90 (3.50) 31.75 (1.25)

15.75 (0.62)

55.88 (2.20)

37.59 (1.48)

53.34 (2.10)

35.30 (1.39)

15.24 (0.60)

16

26.92 (1.06)

25.40 (1.00)

58.42 (2.30)

15.24 (0.60)

39.37 (1.55)

Page 17

V550-A20

V550-A20

Unit: mm (inch) V559-A26B Cradle Mounting Bracket 6.10 (0.24)

36.07 (1.42) 50.04 (1.97)

11.94 (0.47)

19.05 (0.75)

25.91 (1.02)

24.89 (0.98)

PEM S-632 4PL

35.56 (1.40)

11.68 (0.46)

50.04 (1.97) 6.10 (0.24)

50.04 (1.97)

■ BAR CODE SCANNING EXAMPLES Single Line Scan

Raster Scan

Single scan line

Successive and parallel raster laser scan lines

Either 1/2" or 1" at 10" depending on raster bar code model

17

Page 18 read from a scan by OCR; it may hold reading errors

m BAR CODE SAMPLES / NARROW ELEMENT WIDTHS mene moe tng

E-128

“HN Mu

‘ia mW

012354565" | 0°123456°789012 con)

e Codabar

WN Un MLO

Page 19

V550-A20

V550-A20

Precautions ■ LASER BEAM SAFETY "Low power" lasers are by definition incapable of causing eye injury within the duration of the blink, or aversion response (0.25 s) and must be visible (400 nm to 700 nm). Therefore, an ocular hazard can only exist if an individual overcomes his/her natural aversion to bright light and stares directly into the laser beam. There are two product requirements for these lasers: to have a CAUTION label and to have an indicator light to indicate laser emission. The two operational safety rules are:

Follow the instructions on this datasheet for the adjustment and mounting of the V550-A20. Make sure that the laser beam will not be directly or indirectly reflected into human eyes. The safety distance is approximately 1 m for the V550-A20. If there is a possibility of laser beam reflection by any objects around the emitter at the time of adjustment, apply paint with a low light reflection ratio to the objects. The sensor incorporates a laser emission warning light and a "scanning safeguard" feature which shuts off the laser power if the mirror wheel fails to rotate. This ensures that a stationary laser beam cannot emanate from the scan head.

• Do not permit a person to stare at the laser from within the beam. • Do not point the laser at a person's eye at close range. FDA, IEC Laser class

I

IIa

II

IIIa

IIIb

IV

Remote interlock connector

N/A

N/A

N/A

N/A

R

R

Key Control

N/A

N/A

N/A

N/A

R

R

Emission indicator

N/A

N/A

R

R

R

R

Beam attenuator

N/A

N/A

N/A

R

R1

R1

Note: In the chart above: R = require; N/A = not applicable; R1 = delay required between indication and emission.

■ LASER CONTROL REGULATIONS

■ INSTALLATION

The V550-A20 Bar Code Reader meets the standards required by the U.S. Food and Drug Administration (FDA). This reader also has been reported to the Center for Devices and Radiological Health (CDRH). Any service performed on this device should be done so as to not violate compliance with the Code of Federal Regulations, Title 21, Part 1040, Section 10 (21 CFR 1040.10).

Install the bar code reader in a location where the laser beam will not enter the operator's eyes directly or from reflection by a mirrored surface. Also, mount the operation indicator (LED) in a clearly visible location. Avoid interference from ambient light shining into BCR's window. Avoid excessive dust on window. Avoid scratching window. Avoid subjecting the bar code reader to heavy vibration.

Labels (FDA Regulations) Laser radiation warning and information labels are located on the top side of the bar code reader.

■ MAINTENANCE AND REPAIR DANGER! Never disassemble the reader. Users expose themselves to the risk of laser radiation if they disassemble the device.

LASER RADIATION DO NOT STARE INTO BEAM .95 mW SEMICONDUCTOR 670 NANOMETERS CLASS II LASER PRODUCT

Do not attempt repairs or maintenance of the V550-A20. The V550-A20 contains no user serviceable parts. Refer all servicing to an authorized Omron representative.

19

Page 20

V550-A20

V550-A20

DRX is a registered trademark of Accu-Sort Systems, Inc.

NOTE: DIMENSIONS SHOWN of ARE IN MILLIMETERS. To convert millimeters inches, to divide by 25.4. Cat.No. V500-E3-3 In the interest product development, specifications aretosubject change without notice.

OMRON EUROPE B.V. OMRON ELECTRONICS, INC. Wegalaan 67-69 One East Drive 2132 JDCommerce Hoofddorp Schaumburg, IL 60173 The Netherlands 1-800-55-OMRON Phone: +31 23 568 13 00 Fax: +31 23 568 13 883/99 Cat. No. V550-E3-3

20

OMRON CANADA, INC. 885 Milner Avenue Scarborough, 5V8 PrintedOntario in theM1B U.S.A.

416-286-6465 Specifications subject to change without notice.