Page 1
Bar Code Reader
V550-A20
Fixed Position Bar Code Reader with Integrated Decoder Compact size for confined installations ■ Use as a bar code reader or verifier ■ Automatically adjusts for deviations in bar code color, quality and reflectance ■ Raster functions compensate for poorly printed or damaged labels ■ Configurable communications protocal for RS-232, RS-422, RS-485 applications ■ FDA, IEC Class II laser light source ■
Ordering Information ■ BAR CODE READERS Description
Part number
BCR with standard optics
V550-A20
BCR with high density optics
V550-A20HD
BCR with standard optics and high speed motor
V550-A20HS
BCR with standard optics and reconstruction technology (DRX)
V550-A20-X
BCR with high density optics and reconstruction technology (DRX)
V550-A20HD-X
BCR with standard optics, high speed motor and reconstruction technology (DRX)
V550-A20HS-X
BCR with standard optics and 1/2" raster at 10"
V550-A20-R0.5
BCR with high density optics and 1/2" raster at 10"
V550-A20HD-R0.5
BCR with standard optics, high speed motor and 1/2" raster at 10"
V550-A20HS-R0.5
BCR with standard optics and 1" raster at 10"
V550-A20-R1
BCR with high density optics and 1" raster at 10"
V550-A20HD-R1
BCR with standard optics, high speed motor and 1" raster at 10"
V550-A20HS-R1
■ ACCESSORIES Description
Part number
Minature DIN-rail mounting power supply, 3 watts, 5VDC out, 120 VAC in
S82K-00305
Right angle exit attachment
V559-A24
Programming kit (120 VAC)
V559-A25C
Mounting plate
V559-A26A
Cradle mounting bracket
V559-A26B
Picket fence mounting bracket
V559-A26D
Ladder mounting bracket
V559-A26E
Mounting clips
V559-A26F (This table continues on the next page)
Page 2
V550-A20
V550-A20
Accessories Table - continued from previous page Description
Part number
BCR-PLC cable (9-pin RS-232), 2m. Requires external power supply.
V559-A32A-2M
BCR-PLC cable (9-pin RS-232), 5m. Requires external power supply.
V559-A32A-5M
Programming cable (9-pin RS-232), 2m. Requires external power supply.
V559-A32B-2M
■ MANUALS Description
Part number
V550-A20 Operation Manual
Q01BAZ2
V550-A20 Programming Manual (BCSETUP manual) - includes BCSetup software disk
Q02BAZ2
Specifications Part Number
Type Applicable bar code symbols
Reading characteristics
V550-A20 V550-A20-X V550-A20-R0.5 V550-A20-R1
V550-A20HD V550-A20HD-X V550-A20HD-R0.5 V550-A20HD-R1
V550-A20HS V550-A20HS-X V550-A20HS-R0.5 V550-A20HS-R1
Standard
High density
High speed
Detectable bar code types
Code 39, Code 128, UPC-A, UPC-E, EAN-8, EAN-13, Codabar, Interleaved 2 of 5, Straight 2 of 5 (See note 1.), AS-10, 10-bit periodic binary, Code 93, Extensionsfor UPC and EAN types, Pharmacode (See note 2.).
Readable digits
Symbology dependent
Resolution
0.25 mm (0.009 in)
0.13 mm (0.005 in)
0.25 mm (0.009 in)
Reading distance
25-305 mm (1-12 in)
51-152 mm (2-6 in)
25-305 mm (1-12 in)
Max. scan window
244 mm (9.6 in)
122 mm (4.8 in)
244 mm (9.6 in)
Scan rate
500 scans/sec
300 scans/sec
700 scans/sec
Light source
0.95 mW visible red laser diode; 670 nm wavelength, Class II
Decoder
Auto decode installed
Skewed label correction
DRX data reconstruction technology on -X models
Poor label quality
Raster scanning of 1/2" or 1" at 10" on -R0.5 or -R1 models respectively
Indicator
Multi-status LED
Interface
D subminiature male 15 pin connector (RS-232, RS-422, RS-485)
Programming
External computer or terminal
Trigger input
5 V TTL or dry contact
Outputs
2 (open collector - 5 V, 100 mA max.)
Power supply
5 VDC (4.85 VDC minimum, 5.25 VDC maximum)
Current consumption
500 mA typical (600 mA maximum)
Vibration resistance
10 to 150 Hz, 0.5 mm double amplitude for 8 min in each X, Y, and Z direction. Completed 4 times with an acceleration of 7G.
Shock resistance
20 G, 3 times in each ±X, ±Y, and ±Z directions.
Weight
142 g (5 oz)
Environment
Operating temperature
0° to 40°C (32° to 104°F)
Operating humidity
10% to 90% non-condensing
Enclosure rating
NEMA 12
Note: 1. Straight 2 of 5 symbology only available on models with DRX. 2. Pharmacode symbology not available on models with DRX. (This table continues on the next page)
2
Page 3
V550-A20
V550-A20
Specifications Table - continued from previous page Approvals
UL/CSA CE
Listed (USA) NRTL/C (Canada) file number E134951 (when used with a UL listed Class II power supply). EN60950, EN55022, EN50082-1 (SELV power supply required).
Dimensions
65 mm x 54 mm x 36 mm (2.56 in x 2.14 in x 1.43 in)
External devices
• Interface cable • Power supply • PLC and/or host computer
Note: 1. Straight 2 of 5 symbology only available on models with DRX. 2. Pharmacode symbology not available on models with DRX.
Notes ■ DRX® TECHNOLOGY - X Models DRX Technology enables the V550-A20 bar code reader to reconstruct an entire bar code from partial scans of that code. Models that include DRX can read labels that non-DRX models may not.
■ HIGH DENSITY VERSIONS - HD Models Models with high density optics are designed to read bar codes with elements as small as 5 mils at a scan rate of 300 scans per second.
■ HIGH SPEED VERSION - HS Models High speed versions are designed to read at speeds up to 700 scans per second and feature a high speed brushless DC motor.
■ RASTER VERSIONS - R0.5 and R1 Models Raster is the process of projecting the laser beam at varied angles spaced evenly from each other. Typically, the mirror wheel surfaces are angled to create multiple scan lines instead of a single beam. Height of the raster feature, when measured at 10" from the optical window, is either 1/2" or 1" depending on the model.
3
Page 4
V550-A20
V550-A20
Engineering Data ■ OPERATING RANGE CHARTS V550-A20 Narrow element width
Reading distance
Maximum scan window
10.0 mil (0.25 mm)
2.5"-6.0" (64-153 mm)
4.8" (122 mm)
15.0 mil (0.38 mm)
1.0"-7.0" (25-178 mm)
5.6" (142 mm)
20.0 mil (0.5 mm)
1.0"-9.0" (25-228 mm)
7.2" (183 mm)
30.0 mil (0.76 mm)
1.0"-11.0" (25-279 mm)
8.8" (224 mm)
≥40.0 mil (1 mm)
1.0"-12.0" (25-305 mm)
9.6" (244 mm)
Scan Rate: 500 scans per second 127 mm (5.00 in) 101.6 mm (4.00 in) 76.2 mm (3.00 in) 50.8 mm (2.00 in) 25.4 mm (1.00 in) 0.00 mm (0.00 in)
Scan Window
25.4 mm (1.00 in) 50.8 mm (2.00 in)
Narrow Element Width 10.0 mil (0.25 mm)
76.2 mm (3.00 in)
15.0 mil (0.38 mm) 20.0 mil (0.5 mm)
101.6 mm (4.00 in)
30.0 mil (0.76 mm) ≥40.0 mil (≥1 mm) 0.00 mm (0.00 in)
25.4 mm (1.00 in)
50.8 mm (2.00 in)
76.2 mm (3.00 in)
101.6 mm (4.00 in)
127 mm (5.00 in)
152.4 mm (6.00 in)
177.8 mm (7.00 in)
203.2 mm (8.00 in)
228.6 mm (9.00 in)
254 mm (10.00 in)
279.4 mm (11.00 in)
304.8 mm (12.00 in)
127 mm (5.00 in)
Read Distance
Note: These read ranges were obtained using quality bar codes (rated 'A' by ANSI standards). Results may vary depending on quality of bar codes.
4
Page 5
V550-A20
V550-A20
V550-A20HS Narrow element width
Reading distance
Maximum scan window
10.0 mil (0.25 mm)
2.5"-5.0" (64-127 mm)
4.0" (102 mm)
15.0 mil (0.38 mm)
1.0"-7.0" (25-178 mm)
5.6" (142 mm)
20.0 mil (0.5 mm)
1.0"-9.0" (25-228 mm)
7.2" (183 mm)
30.0 mil (0.76 mm)
1.0"-11.0" (25-279 mm)
8.8" (224 mm)
≥40.0 mil (1 mm)
1.0"-12.0" (25-305 mm)
9.6" (244 mm)
Scan Rate: 700 scans per second 127 mm (5.00 in) 101.6 mm (4.00 in) 76.2 mm (3.00 in) 50.8 mm (2.00 in) 25.4 mm (1.00 in) 0.00 mm (0.00 in)
Scan Window
25.4 mm (1.00 in) 50.8 mm (2.00 in)
Narrow Element Width 10.0 mil (0.25 mm)
76.2 mm (3.00 in)
15.0 mil (0.38 mm) 20.0 mil (0.5 mm)
101.6 mm (4.00 in)
30.0 mil (0.76 mm) ≥40.0 mil (≥1 mm) 0.00 mm (0.00 in)
25.4 mm (1.00 in)
50.8 mm (2.00 in)
76.2 mm (3.00 in)
101.6 mm (4.00 in)
127 mm (5.00 in)
152.4 mm (6.00 in)
177.8 mm (7.00 in)
203.2 mm (8.00 in)
228.6 mm (9.00 in)
254 mm (10.00 in)
279.4 mm (11.00 in)
304.8 mm (12.00 in)
127 mm (5.00 in)
Read Distance
Note: These read ranges were obtained using quality bar codes (rated 'A' by ANSI standards). Results may vary depending on quality of bar codes.
5
Page 6
V550-A20
V550-A20
V550-A20HD Standard Scan Head–Optical Performance (Model V550-A20) Narrow element width
Reading distance
5.0 mil (0.13 mm)
2.0"-4.0" (51-102 mm)
Maximum scan window 3.2" (81 mm)
7.5 mil (0.19 mm)
2.0"-4.25" (51-108 mm)
3.4" (86 mm)
10.0 mil (0.25 mm)
2.0"-4.5" (51-114 mm)
3.6" (91 mm)
15.0 mil (0.38 mm)
2.0"-5.0" (51-127 mm)
4.0" (102 mm)
≥20.0 mil (≥0.51 mm)
2.0"-6.0" (51-152 mm)
4.8" (122 mm)
Scan Rate: 300 scans per second 76.2 mm (3.00 in)
50.8 mm (2.00 in)
0.00 mm (0.00 in)
25.4 mm (1.00 in)
Narrow Element Width 5.0 mil (0.13 mm) 7.5 mil (0.19 mm) 10.0 mil (0.25 mm) 15.0 mil (0.38 mm)
50.8 mm (2.00 in)
≥ 20.0 mil ≥ (0.51 mm)
0.00 mm (0.00 in)
25.4 mm (1.00 in)
50.8 mm (2.00 in)
76.2 mm (3.00 in)
Scan Window
25.4 mm (1.00 in)
101.6 mm (4.00 in)
127 mm (5.00 in)
152.4 mm (6.00 in)
76.2 mm (3.00 in)
Read Distance
Note: These read ranges were obtained using quality bar codes (rated 'A' by ANSI standards). Results may vary depending on quality of bar codes.
6
Page 7
V550-A20
V550-A20
Connection ■ V550-A20 PIN ALLOCATION Pin No.
Signal
Description
1
GND
Signal ground
2
TXD
Transmit data (RS-232)
3
RXD
Receive data (RS-232)
4
OUT 0
NVC/No match output
5
OUT 1/CTS/TACH
GO/Match output/Clear to send (RS-232)/ Tachometer connection
6
SD+
Send data (RS-422)/Non-inverting line (RS-485)
7
RD+
Receive data (RS-422)
8
SD-
Send data (RS-422)/Inverting line (RS-485)
9
RD-
Receive data (RS-422)
10
N/C
No connection
11
GND
Ground
12
Analog code
Analog signal output
13
Trigger
Trigger input
14
+5V
Power input
15
+5V
Power input
V550-A20 Connector 15 Pin male "D"
■ PINOUT DIAGRAMS RS-232 With No Handshaking
HOST
V550-A20 1
6
S. GND RXD TXD
GND TXD RXD GND +5VDC
15
RS-422 (Point to Point) 220 Termination
V550-A20 1
6
15
1 6 8 7 9
220 Termination
HOST
GND SD+ SD-
S. GND RD+ RD-
RD+
SD+
RD-
SD-
Note: Termination resistors may be placed inside the connector strain relief. The termination resistor value is 220 OHM, 1/4 watt. With RS-422, the receive lines on both sides must be terminated.
7
Page 8
V550-A20
V550-A20
RS-232 With RTS/CTS Handshaking
V550-A20
HOST
1
GND TXD RXD
1 2 3
GND RXD TXD CTS
15
6
RTS
CTS
5 GND 11 +5VDC 15
RS-485 Multipdrop 220 OHM, 1/4 watt Termination (Polling required)
V550-A20 1
15
6
End of the line
HOST
1 6 8
GND
S GND
SD+/RD+ SD-/RD-
S D + / R D + End of the line SD-/RD-
1 6 8
GND
1 6 8
GND
SD+/RD+ SD-/RD-
SD+/RD+ SD-/RD-
220 OHM, 1/4 watt Termination
Note: RS-485 allows for communication across the same lines. Termination resistors can be placed inside the connector strain relief. The transmit-receive lines on both sides must be terminated. V559-A25C Programming Kit
CONNECTIONS
BCR 15 PIN FEMALE
HOST
2
TXD
RD
3
RXD
SD
GND
SG
1 15 11
2 3
9 PIN FEMALE
5
+5V GND
V559-A32A BCR-PLC Cable (9-pin RS-232)
CONNECTIONS
BCR 15 PIN FEMALE
RD
TXD
3
RXD
SD
GND
SG
15 11
+5V
RS
GND
3 2 9
FG
15 PIN FEMALE
HOST
2
TXD
RD
3
RXD
SD
GND
SG
1 15
5
11
1
8
9 PIN MALE
4
CS
CONNECTIONS
BCR
HOST
2
1
V559-A32B
+5V GND
2 3 5
9 PIN FEMALE
Page 9
V550-A20
V550-A20
Configuration ■ SETTING UP BCR WITH PERSONAL COMPUTER 1
Configuration software
2
Laptop computer
3
Bar code reader
V550-A20
4
Programming kit
V559-A25C
1
BCSETUP
3
2 4
■ INSTALLING BCSETUP CONFIGURATION SOFTWARE To install BCSetup on PC's hard drive, follow instructions on diskette label.
■ TEST SETUP PROCEDURE To retrieve settings from device: • Confirm that the bar code reader (BCR) is communicating with device. Select menu option "Retrieve Setup from Device" and press <Enter>.
To change the Bar Code to 8 character Code 39 with no Modulus Check: • Select the menu option "Bar Code Setup" and highlight the "Bar Code #1" selection.
To change the No Read Message to question marks:
• Use <space bar> to toggle to "Code 39".
• Select the menu option "Communication Setup" and use the down arrow key to highlight the "No Read Message" selection.
• Press down arrow key (or <Enter>) once to highlight "Number of Characters" selection. Enter "00" in "Number of Characters" selection.
• Enter "?". Delete any remaining message. Press <Esc> to return to the Main Menu.
• Highlight "Modulus Check Character" selection. Toggle to "Disabled".
To deactivate code quality functions:
• Press <Esc> to return to Main Menu.
• Select the menu option "Communication Setup" and use the down arrow key to highlight the "Delimiter Between Data and Code Quality" selection. • Enter "X". Press <Esc> to return to the Main Menu. To change the Trigger to Serially Controlled Trigger: • Select the menu option "Trigger Setup" and use the down arrow key to highlight the "Scanner Trigger Type" selection. • Use <space bar> to toggle through choices until "Serially Controlled" is selected. Press <Esc> to return to the Main Menu.
To program the V550-A20 with the new settings: • Select the menu option "Program Mode" and highlight "Select Programming Command". • Toggle to "Transfer Settings to Device and Use". (Note: settings will remain active until unit is powered down. When power is restored, original settings will be in effect.) • Press <Enter>. • Press <Esc> to return to Main Menu. To read sample bar codes from this datasheet: • Select menu option "CRT Mode" and press <Enter>. • Press S (upper case) to start trigger cycle and turn on laser. • Hold sample Code 39 bar code in front of BCR. • Press E (upper case) to end trigger cycle and turn off laser. • The bar code reader will send the bar code message (along with a space and the number of times it read the bar code) to the computer screen.
9
Page 10
V550-A20
V550-A20
PLC Connection Examples ■ SYSMAC SERIES CQM1 CONTROLLER WITH RS-232 CONNECTION 3
1
2
7
4
6
5
1
Power supply unit
CQM1-PA206
2
CPU unit
CQM1-CPU21
3
Programming console
CQM1-PRO
4
Bar code reader
V550-A20
5
Connecting cable
V559-A32A-2M
6
BCR power supply
S82S-0305 (5V, 0.6A) (see note)
7
Trigger switch
Relay or switch
Note: Not rated for UL Class II operation.
■ OPERATION
■ CONFIRMATION OF OPERATION
Switch ON trigger switch 7 shown above to execute V550-A20 to read and send data to the data memory area of CQM1. Use the program console 3 to confirm the data. In the event the data was not read, press "?" after the trigger switch is OFF.
• After programming, set RUN mode and set the trigger switch ON to execute the reading with the LED on the BCR lighting.
■ V550-A20 SETUP • Communication condition (setup): Baud rate: 9600 bps Word length: 7 bit Parity: EVEN Stop bit: 2 bit • Trigger Requirements: Start code: S Stop code: E Data output mode: Single output Scan trigger type: Serially controlled Trigger stage: Standard
■ CQM1 SETUP • Communication condition: Set OFF dip switch 5 of CQM1 and set [1000] on DM6645 to match the communication condition with BCR (refer to the CQM1 programming manual for the detailed way to change the condition).
• Press the key in the order below in order to confirm the data with the console: 1 CLEAR ➝ 2 FUN ➝ 3 MONITOR • The "?" is indicated, in the event that the data can't be read until the trigger switch is OFF.
■ CQM1 PROGRAMMING 00000 00000
00003
00101
AR0805
• Setting of Start code and Stop code: Set [2000] on DM6648. • On the DM, set the ASCII code [S] to Start Reading and [E] to Stop Reading.
00102 00007
• Connection of trigger switch: Connect the trigger switch to the input port [00000] terminal on the CPU unit to be able to send [S] or [E] through the RS-232C line when the BCR is ON or OFF, respectively. • Save the received data from the BCR in the order from upper digit, DM0200 must be the top, to down.
AR0806 00010
AR0805
DIFU(13)00101
Trigger switch ON (DIFFERENTIATE UP on rising pulse)
DIFU(14)00102
Trigger switch OFF (DIFFERENTIATE DOWN on falling pulse)
TXD(48) DM0100 #0000 #0001
Send 1 byte of DM0100 [Set to 5300] (S: send command to start reading)
BSET(71) #0000 DM0200 DM0220
DM0200-DM0220 clear (assume 20 readable digits)
TXD(48) DM0101 #0000 #0001
Send 1 byte of DM0101 [Set to 4500] (E: send command to stop reading)
RXD(47) DM0200 #0000 AR09
Store data from DM0200 buffer
MSG(46) DM0200
10
Indicate 16 levels of DM0200 to programmable controller