The text of a manual · part 9 of 12
V520-LHA7127 Miniature High Speed CCD Fixed Position Scanner User Manual, pages 48 to 57
Pages 48 to 57 of 77
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron V520
Page 48
Appendix A - Programming Menus & Commands
V520-LHA7127
Setting Suffixes (Identifying the Symbology) (cont.) Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
O2
EAN–13 +2 or +5
N9
EAN-8
O3
EAN-8 +2 or +5
O4
Code 39
O5
Codabar (NW-7)
O6
Industrial 2 of 5
O7
Interleaved 2 of 5
O8
Code 93
O9
Code 128
D9
IATA
N5
MSI/Plessey
Z4
Display Suffix value and length
-[8-P3-O:-P!-P5-P6-P7-P8-P9-P:-E:-O6-[5-
Note The global default, also clears all suffixes.
39
Page 49
Appendix A - Programming Menus & Commands
V520-LHA7127
14. Direct Input of Numeric Characters
40
Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
Q0
0
Q1
1
Q2
2
Q3
3
Q4
4
Q5
5
Q6
6
Q7
7
Q8
8
Q9
9
(Z7)
START/END Programming Menu
-[8-R1-R2-R3-R!-R5-R6-R7-R8-R9-R:-[8-
Page 50
Appendix A - Programming Menus & Commands
V520-LHA7127
15. Direct Input of Alpha Characters Computer Command
Function/ Description
Bar Code Command
Computer Command
Function/ Description
(Z7)
START/END Program Menu
0N
N
0A
A
0O
O
0B
B
0P
P
0C
C
0Q
Q
0D
D
0R
R
0E
E
0S
S
0F
F
0T
T
0G
G
0U
U
0H
H
0V
V
0I
I
0W
W
0J
J
0X
X
0K
K
0Y
Y
0L
L
0Z
Z
0M
M
-[8-1B-1C-1D-1E-1F-1G-1H-1I-1J-1K-1L-1M-1N-
(Z7)
START/END Program Menu
Bar Code Command
-1O-1P-1Q-1R-1S-1T-1U-1V-1W-1X-1Y-1Z-1[-[8-
41
Page 51
Appendix A - Programming Menus & Commands
V520-LHA7127
16. Direct Input of Control Characters Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
1A
STX
1B
ETX
1C
CR
1D
LF
-[8-2B-2C-2D-2E-
17. Enable Number of Characters / Digits Transmitted This feature instructs the scanner to calculate and transmit a number indicating the total number of characters that are being transmitted to the host. This feature allows the host to verify that the correct amount of data was received. Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
3A
UPC-A
3B
UPC-A +2 or +5
3C
UPC-E
3D
UPC-E +2 or +5
3E
EAN-13
3F
EAN-13 +2 or +5
-[8-!B-!C-!D-!E-!F-!GContinued on next page.....
42
Page 52
Appendix A - Programming Menus & Commands
V520-LHA7127
Enable Number of Characters / Digits Transmitted (cont.) Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
3G
EAN-8
3H
EAN-8 +2 or +5
3I
Code 39
3J
Codabar (NW-7)
3K
Industrial 2 of 5
3L
Interleaved 2 of 5
3M
Code 93
3N
Code 128
3O
MSI/Plessey
3P
IATA
3Z
Transmit data length (all symbologies)
-[8-!H-!I-!J-!K-!L-!M-!N-!O-!P-!Q-![-
43
Page 53
Appendix A - Programming Menus & Commands
V520-LHA7127
18. Disable Number of Characters / Digits Transmitted ComputerCommand
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
2A
UPC-A
2B
UPC-A +2 or +5
2C
UPC-E
2D
UPC-E +2 or +5
2E
EAN-13
2F
EAN-13 +2 or +5
2G
EAN-8
2H
EAN-8 +2 or +5
2I
Code 39
2J
Codabar (NW-7)
2K
Industrial 2 of 5
2L
Interleaved 2 of 5
2M
Code 93
-[8-3B-3C-3D-3E-3F-3G-3H-3I-3J-3K-3L-3M-3NContinued on next page.....
44
Page 54
Appendix A - Programming Menus & Commands
V520-LHA7127
Disable Number of Characters / Digits Transmitted (cont,) Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
2N
Code 128
2O
MSI/Plessey
2P
IATA
2Z
Do not transmit data length (all symbologies)
-[8-3O-3P-3Q-3[-
19. Communication Parameters Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
K1
300 Baud *
K2
600 Baud *
K3
1,200 Baud *
K4
2,400 Baud *
K5
4,800 Baud *
K6
9,600 Baud
-[8-L2-L3-L!-L5-L6-L7-
* Use Z2 Command after computer command to store settings in memory prior to power off. Continued on next page.....
45
Page 55
Appendix A - Programming Menus & Commands
V520-LHA7127
Communications Parameters (cont.) Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
K7
19,200 Baud *
K8
38,400 Baud *
L0
7 Data Bits *
L1
8 Data bits *
L2
Parity = None
L3
Parity = Even *
L4
Parity = Odd *
L5
1 Stop Bit *
L6
2 Stop Bits *
-[8-L8-L9-M1-M2-M3-M!-M5-M6-M7-
* Use Z2 Command after computer command to store settings in memory prior to power off.
46
Page 56
Appendix A - Programming Menus & Commands
V520-LHA7127
20. Handshaking Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
I0
Wait for CTS from terminal = Unlimited
I1
Wait for CTS from terminal = 100 mS
I2
Wait for CTS from terminal = 200 mS
I3
Wait for CTS from terminal = 400 mS
I4
ACK/NAK Delay Time Unlimited
I5
ACK/NAK Delay Time = 100 mS
I6
ACK/NAK Delay Time = 500 mS
I7
ACK/NAK Delay Time = 1000 mS
P0
No Handshaking * (Factory Set)
P1
Busy/Ready *
P2
Modem *
P3
ACK/NAK *
P4
ACK or No response NAK*
P5
No ACK/NAK *
-[8-J1-J2-J3-J!-J5-J6-J7-J8-Q1-Q2-Q3-Q!-Q5-Q6-
* Use Z2 Computer Command to store in memory prior to power off.
47
Page 57
Appendix A - Programming Menus & Commands
V520-LHA7127
21. Buzzer Operation Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
T0
Volume = Maximum
T1
Volume = Upper Mid-range
T2
Volume = Lower Mid-range
T3
Volume = Minimum
V5
Ring buzzer once at 3kHz for 200 mS
V6
Ring buzzer once at 3kHz, 2kHz interval for 200 mS
V7
Ring buzzer once at 2kHz, 3kHz interval for 200 mS
W0
Disable buzzer
W1
Enable buzzer at 3kHz
W2
Enable buzzer at 3kHz with 2.5kHz interval
W3
Enable buzzer at 2kHz with 3kHz interval
W4
Buzzer duration 0.10 sec
-[8-U1-U2-U3-U!-W6-W7-W8-X1-X2-X3-X!-X5Continued on next page.....
48