The text of a manual · part 10 of 12
V520-LHA7127 Miniature High Speed CCD Fixed Position Scanner User Manual, pages 58 to 67
Pages 58 to 67 of 77
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron V520
Page 58
Appendix A - Programming Menus & Commands
V520-LHA7127
Buzzer Operation (cont.) Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
W5
Buzzer duration 0.20 sec
W6
Buzzer duration 0.40 sec
W7
Buzzer duration 0.05 sec
W8
Buzzer duration 0.01 sec
-[8-X6-X7-X8-X9-
49
Page 59
Appendix A - Programming Menus & Commands
V520-LHA7127
22. Positive & Negative Bar Codes Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
V4
Positive bar code only (black bars/white spaces)
V2
Both positive & negative bar code
-[8-W3-W5-
23. Setting the Trigger Function Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
S7
Disable the trigger function/Red scanning light is ON continuously (Factory Set)
-[8-T8-
S8
Enable the trigger function /Red scanning light is OFF until trigger is activated or “pulled”
-T9-
Z
Activate the trigger; turns on the red scanning light
Use Computer Command
The trigger function is disabled in the default setting. This means that the red scanning light is “ON” continuously and the scanner is always ready to read. For some applications, you may wish to activate the scanner only at a specific time. This can be done by enabling the Trigger function. Once in the “Trigger Enabled” mode, the red scanning light is OFF until the trigger is activated or “pulled.” Either a hardware trigger or a software trigger pulse may be used to activate the scanner. The hardware trigger is actuated by pulling Pin #1 (on the standard DB25 female connector) LOW. The software trigger is actuated by downloading and <ESC> Z <CR> computer command from the host. (See Scanner Timeout to establish the length of time the scanning light remains ON after the trigger is activated).
50
Page 60
Appendix A - Programming Menus & Commands
V520-LHA7127
24. Selecting the Read Mode Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
S0
Single Read Mode (Trigger enabled mode only)
S1
Multiple Read Mode
S2
Continuous Read Mode
7E
Scan 2 labels straight across
7F
Scan 3 labels straight across
7G
Scan 4 labels straight across
7H
Does not allow first bar distortion
7I
Allow first bar distortion *
7O
Normal Scan
7P
Slanted Scan
7Y
Regular expression up to 5 labels
-[8-T1-T2-T3-8F-8G-8H-8I-8J-8P-8Q-8Z-
* Relaxes tolerance on first bar, increasing to 8x narrow bar width on first bar. Decoding time may be increased. Continued on next page.....
51
Page 61
Appendix A - Programming Menus & Commands
V520-LHA7127
Selecting the Read Mode (cont.) The operation of the scanner in the various read modes is described in the table below. The “Continuous Read” mode is helpful in positioning the scanner for optimum reading. In “Continuous Read,” the scanner’s buzzer functions like a Geiger counter, sounding the most active at the position achieving the greatest number of good reads. Mode
Trigger Function Enabled
Trigger Function Disabled
After receiving a trigger pulse, scanner will read multiple, different bar codes in succession until it times out.
Scanner will read different bar codes in succession if they are presented to the read window.
Scanner will not read the same bar code twice if they are consecutive.
Scanner will not read the same bar code twice if they are consecutive.
Continuous Read
Scanner will read the same bar code continuously after receiving a trigger pulse until scanner times out.
Scanner will read the same bar code continuously.
Single Read
Scanner will read only one bar code after receiving a trigger pulse.
Same as Multiple Read mode, above.
Multiple Read
52
Page 62
Appendix A - Programming Menus & Commands
V520-LHA7127
25. Scanner Timeout (Trigger Enabled Mode only) These commands, which are only applicable in the Trigger enabled mode, establish the time-out period after the trigger pulse is received. The time-out period is the same whether the scanner is operating in Single, Multiple or Continuous Read mode. Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
Y0
Trigger remains ON as long as trigger is pulled (hardware trigger only)
-[8-Z1-
Y1
1 Second after triggering
Y2
2 Seconds after triggering
Y3
3 Seconds after triggering
Y4
4 Seconds after triggering
Y5
6 Seconds after triggering
Y6
8 Seconds after triggering
Y7
10 Seconds after triggering
-Z2-Z3-Z!-Z5-Z6-Z7-Z8-
53
Page 63
Appendix A - Programming Menus & Commands
V520-LHA7127
26. Redundant Decoding The Number of Redundant Decodes determines how many times the scanner must decode a bar code and obtain the same value before it will transmit the data. For example, if the redundancy is set at three times, the scanner will not transmit data until it has decoded the bar code and obtained the same values three times in succession. If it obtains the same value twice in a row, but a different value on the third read attempt, it will not transmit. If it gets the same value three out of four times, it will not transmit. It must receive three consecutive, identical reads.
54
Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
X0
Read bar code once
X1
Read bar code twice
X2
Read bar code three times
X3
Read bar code four times
7R
Read bar code five times
7S
Read bar code six times
-[8-Y1-Y2-Y3-Y!-8S-8T-
Page 64
Appendix A - Programming Menus & Commands
V520-LHA7127
27. Transmitting Error Indications (Trigger Enabled only) Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
5E
Do not transmit error code
5F
Transmit “BR” <CR> for bad read or no read
5G
Transmit <STX>“>”<ETX> for bad read; <STX>“?”<ETX> for no read
-[8-6F-6G-6H-
5H
Transmit “>”<CR> for bad read Transmit “?”<CR> for no read
5I
Transmit “CAN”<CR> for bad read or no read
5J
Transmit <STX>“CAN”<ETX> for bad read or no read
-6I-6J-6K-
28. Print Quality Adjustments Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
X4
For lower density, poor print quality bar code, e.g., dot matrix with voids (low analog gain)
-[8-Y5-
X5
For high density, good print quality bar code without voids (high analog gain)
-Y6-
X6
Output data obtained from Low or High analog gain
X7
Output data obtained from Low and High analog gain
-Y7-Y8-
55
Page 65
Appendix A - Programming Menus & Commands
V520-LHA7127
29. LED Operation
56
Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
T4
Good read LED disabled after decode
T8
Good read LED ON after decode for .10 seconds
T5
Good read LED ON after decode for .20 seconds
T6
Good read LED ON after decode for .40 seconds
T7
Good read LED ON after decode for .80 seconds
V0
LED ON Red for .40 seconds
V1
LED ON Red for .80 seconds
V8
LED ON Green for .40 seconds
V9
LED ON Green for .80 seconds
-[8-U5-U9-U6-U7-U8-W1-W2-W9-W:-
Page 66
Appendix A - Programming Menus & Commands
V520-LHA7127
30. Sequencer Controls Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
8A
Trigger Input (sync signal positive logic) High active
8B
Trigger Input (sync signal negative logic) Low active
8C
Sequencer output synchronous transmission *
8D
Sequencer output synchronous transmission * (negative – true logic)
-[8-9B-9C-9D-9E-
8E
Sequencer output one-shot transmission *
8F
Sequencer output one-shot transmission * (negative – true logic)
8G
Sequencer output one-shot duration 10 mS
8H
Sequencer output one-shot duration 20 mS
8I
Sequencer output one-shot duration 30 mS
8J
Sequencer output one-shot duration 40 mS
8K
Sequencer output one-shot duration 50 mS
8L
Sequencer output one-shot duration 60 mS
-9F-9G-9H-9I-9J-9K-9L-9M-
* Use Z2 computer command to store in memory prior to power off. Continued on next page.....
57
Page 67
Appendix A - Programming Menus & Commands
V520-LHA7127
Sequencer Controls (cont.) Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
8M
Sequencer output one-shot duration 70 mS
8N
Sequencer output one-shot duration 80 mS
8O
Sequencer output one-shot duration 90 mS
8P
Sequencer output one-shot duration 100 mS
8Q
Outputs sequencer *
8R
Does not output sequencer *
-[8-9N-9O-9P-9Q-9R-9S-
* Use Z2 computer command to store in memory prior to power off.
58