Page 58

Appendix A - Programming Menus & Commands

V520-LHA7127

Buzzer Operation (cont.) Computer Command

Function/Description

Bar Code Command

(Z7)

START/END Programming Menu

W5

Buzzer duration 0.20 sec

W6

Buzzer duration 0.40 sec

W7

Buzzer duration 0.05 sec

W8

Buzzer duration 0.01 sec

-[8-X6-X7-X8-X9-

49

Page 59

Appendix A - Programming Menus & Commands

V520-LHA7127

22. Positive & Negative Bar Codes Computer Command

Function/Description

Bar Code Command

(Z7)

START/END Programming Menu

V4

Positive bar code only (black bars/white spaces)

V2

Both positive & negative bar code

-[8-W3-W5-

23. Setting the Trigger Function Computer Command

Function/Description

Bar Code Command

(Z7)

START/END Programming Menu

S7

Disable the trigger function/Red scanning light is ON continuously (Factory Set)

-[8-T8-

S8

Enable the trigger function /Red scanning light is OFF until trigger is activated or “pulled”

-T9-

Z

Activate the trigger; turns on the red scanning light

Use Computer Command

The trigger function is disabled in the default setting. This means that the red scanning light is “ON” continuously and the scanner is always ready to read. For some applications, you may wish to activate the scanner only at a specific time. This can be done by enabling the Trigger function. Once in the “Trigger Enabled” mode, the red scanning light is OFF until the trigger is activated or “pulled.” Either a hardware trigger or a software trigger pulse may be used to activate the scanner. The hardware trigger is actuated by pulling Pin #1 (on the standard DB25 female connector) LOW. The software trigger is actuated by downloading and <ESC> Z <CR> computer command from the host. (See Scanner Timeout to establish the length of time the scanning light remains ON after the trigger is activated).

50

Page 60

Appendix A - Programming Menus & Commands

V520-LHA7127

24. Selecting the Read Mode Computer Command

Function/Description

Bar Code Command

(Z7)

START/END Programming Menu

S0

Single Read Mode (Trigger enabled mode only)

S1

Multiple Read Mode

S2

Continuous Read Mode

7E

Scan 2 labels straight across

7F

Scan 3 labels straight across

7G

Scan 4 labels straight across

7H

Does not allow first bar distortion

7I

Allow first bar distortion *

7O

Normal Scan

7P

Slanted Scan

7Y

Regular expression up to 5 labels

-[8-T1-T2-T3-8F-8G-8H-8I-8J-8P-8Q-8Z-

* Relaxes tolerance on first bar, increasing to 8x narrow bar width on first bar. Decoding time may be increased. Continued on next page.....

51

Page 61

Appendix A - Programming Menus & Commands

V520-LHA7127

Selecting the Read Mode (cont.) The operation of the scanner in the various read modes is described in the table below. The “Continuous Read” mode is helpful in positioning the scanner for optimum reading. In “Continuous Read,” the scanner’s buzzer functions like a Geiger counter, sounding the most active at the position achieving the greatest number of good reads. Mode

Trigger Function Enabled

Trigger Function Disabled

After receiving a trigger pulse, scanner will read multiple, different bar codes in succession until it times out.

Scanner will read different bar codes in succession if they are presented to the read window.

Scanner will not read the same bar code twice if they are consecutive.

Scanner will not read the same bar code twice if they are consecutive.

Continuous Read

Scanner will read the same bar code continuously after receiving a trigger pulse until scanner times out.

Scanner will read the same bar code continuously.

Single Read

Scanner will read only one bar code after receiving a trigger pulse.

Same as Multiple Read mode, above.

Multiple Read

52

Page 62

Appendix A - Programming Menus & Commands

V520-LHA7127

25. Scanner Timeout (Trigger Enabled Mode only) These commands, which are only applicable in the Trigger enabled mode, establish the time-out period after the trigger pulse is received. The time-out period is the same whether the scanner is operating in Single, Multiple or Continuous Read mode. Computer Command

Function/Description

Bar Code Command

(Z7)

START/END Programming Menu

Y0

Trigger remains ON as long as trigger is pulled (hardware trigger only)

-[8-Z1-

Y1

1 Second after triggering

Y2

2 Seconds after triggering

Y3

3 Seconds after triggering

Y4

4 Seconds after triggering

Y5

6 Seconds after triggering

Y6

8 Seconds after triggering

Y7

10 Seconds after triggering

-Z2-Z3-Z!-Z5-Z6-Z7-Z8-

53

Page 63

Appendix A - Programming Menus & Commands

V520-LHA7127

26. Redundant Decoding The Number of Redundant Decodes determines how many times the scanner must decode a bar code and obtain the same value before it will transmit the data. For example, if the redundancy is set at three times, the scanner will not transmit data until it has decoded the bar code and obtained the same values three times in succession. If it obtains the same value twice in a row, but a different value on the third read attempt, it will not transmit. If it gets the same value three out of four times, it will not transmit. It must receive three consecutive, identical reads.

54

Computer Command

Function/Description

Bar Code Command

(Z7)

START/END Programming Menu

X0

Read bar code once

X1

Read bar code twice

X2

Read bar code three times

X3

Read bar code four times

7R

Read bar code five times

7S

Read bar code six times

-[8-Y1-Y2-Y3-Y!-8S-8T-

Page 64

Appendix A - Programming Menus & Commands

V520-LHA7127

27. Transmitting Error Indications (Trigger Enabled only) Computer Command

Function/Description

Bar Code Command

(Z7)

START/END Programming Menu

5E

Do not transmit error code

5F

Transmit “BR” <CR> for bad read or no read

5G

Transmit <STX>“>”<ETX> for bad read; <STX>“?”<ETX> for no read

-[8-6F-6G-6H-

5H

Transmit “>”<CR> for bad read Transmit “?”<CR> for no read

5I

Transmit “CAN”<CR> for bad read or no read

5J

Transmit <STX>“CAN”<ETX> for bad read or no read

-6I-6J-6K-

28. Print Quality Adjustments Computer Command

Function/Description

Bar Code Command

(Z7)

START/END Programming Menu

X4

For lower density, poor print quality bar code, e.g., dot matrix with voids (low analog gain)

-[8-Y5-

X5

For high density, good print quality bar code without voids (high analog gain)

-Y6-

X6

Output data obtained from Low or High analog gain

X7

Output data obtained from Low and High analog gain

-Y7-Y8-

55

Page 65

Appendix A - Programming Menus & Commands

V520-LHA7127

29. LED Operation

56

Computer Command

Function/Description

Bar Code Command

(Z7)

START/END Programming Menu

T4

Good read LED disabled after decode

T8

Good read LED ON after decode for .10 seconds

T5

Good read LED ON after decode for .20 seconds

T6

Good read LED ON after decode for .40 seconds

T7

Good read LED ON after decode for .80 seconds

V0

LED ON Red for .40 seconds

V1

LED ON Red for .80 seconds

V8

LED ON Green for .40 seconds

V9

LED ON Green for .80 seconds

-[8-U5-U9-U6-U7-U8-W1-W2-W9-W:-

Page 66

Appendix A - Programming Menus & Commands

V520-LHA7127

30. Sequencer Controls Computer Command

Function/Description

Bar Code Command

(Z7)

START/END Programming Menu

8A

Trigger Input (sync signal positive logic) High active

8B

Trigger Input (sync signal negative logic) Low active

8C

Sequencer output synchronous transmission *

8D

Sequencer output synchronous transmission * (negative – true logic)

-[8-9B-9C-9D-9E-

8E

Sequencer output one-shot transmission *

8F

Sequencer output one-shot transmission * (negative – true logic)

8G

Sequencer output one-shot duration 10 mS

8H

Sequencer output one-shot duration 20 mS

8I

Sequencer output one-shot duration 30 mS

8J

Sequencer output one-shot duration 40 mS

8K

Sequencer output one-shot duration 50 mS

8L

Sequencer output one-shot duration 60 mS

-9F-9G-9H-9I-9J-9K-9L-9M-

* Use Z2 computer command to store in memory prior to power off. Continued on next page.....

57

Page 67

Appendix A - Programming Menus & Commands

V520-LHA7127

Sequencer Controls (cont.) Computer Command

Function/Description

Bar Code Command

(Z7)

START/END Programming Menu

8M

Sequencer output one-shot duration 70 mS

8N

Sequencer output one-shot duration 80 mS

8O

Sequencer output one-shot duration 90 mS

8P

Sequencer output one-shot duration 100 mS

8Q

Outputs sequencer *

8R

Does not output sequencer *

-[8-9N-9O-9P-9Q-9R-9S-

* Use Z2 computer command to store in memory prior to power off.

58