The text of a manual · part 8 of 12
V520-LHA7127 Miniature High Speed CCD Fixed Position Scanner User Manual, pages 38 to 47
Pages 38 to 47 of 77
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron V520
Page 38
Appendix A - Programming Menus & Commands
V520-LHA7127
4. Delete/Deactivate Specific Bar Code Symbologies Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
4A
Disable all WPC (including Addon)
4B
Disable UPC (A/E)
4C
Disable UPC (A/E) +2
4D
Disable UPC (A/E) +5
4E
Disable EAN (13/8)
4F
Disable EAN (13/8) +2
4G
Disable EAN (13/8) +5
4H
Disable Code 39
4I
Disable Codabar (NW-7)
4J
Disable 2 of 5 (Industrial/Interleaved)
4K
Disable Industrial 2 of 5
4L
Disable Interleaved 2 of 5
4M
Disable Code 93
-[8-5B-5C-5D-5E-5F-5G-5H-5I-5J-5K-5L-5M-5NContinued on next page.....
29
Page 39
Appendix A - Programming Menus & Commands
V520-LHA7127
Delete/Deactivate Specific Bar (cont.) Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
4N
Disable Code 128
4O
Disable MSI/Plessey
4P
Disable IATA
4Z
Disable all symbologies
-[8-5O-5P-5Q-5[-
5. Options for UPC
30
Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
E2
UPC-A (13 Digits) Add leading zero; Enable check digit
-[8-F3- %
E3
UPC-A (12 Digits) Do not add leading zero; Enable check digit
-F!-
E4
UPC-A (12 Digits) Add leading zero; Disable check digit
-F5-
E5
UPC-A (11 Digits) Do not add leading zero; Disable check digit
-F6-
E6
UPC-E (8 Digits) Add leading zero; Enable check digit
-F7-
E7
UPC-E (7 Digits) Do not add leading zero; Enable check digit
E8
UPC-E (7 Digits) Add leading zero; Disable check digit
-F9-
E9
UPC-A (6 Digits) Do not add leading zero; Disable check digit
-F:-
-F8- %
Page 40
Appendix A - Programming Menus & Commands
V520-LHA7127
6. Options for Code 39 Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
7C
Enable 1 character (3 characters including start/stop characters)
7D
Disable 1 character
C0
Disable check digit calculation
-[8-8D-8E-D1- %
C1
Enable check digit calculation
C2
Transmit check digit
C3
Do not transmit check digit
D0
Do not transmit start/stop characters (*……*)
D1
Transmit start/stop characters (*……*)
-D2-D3-D!-E1-E2- %
• 43 Data digits are available: 0 to 9, A to Z (caps only) plus . - $ / + % and space. If a check digit is present, it will appear as part of the data. • If the scanner is programmed to calculate the check digit, and the bar code is not printed with a check digit, the bar code will not read. • Another option available for Code 39 is to enable the reading of a single character bar code. See the section on Fixing the Digit for this option.
31
Page 41
Appendix A - Programming Menus & Commands
V520-LHA7127
7. Options for Codabar (NW-7) Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
7K
Enable 1 character (3 characters including start/stop characters)
7L
Disable 1 character
F0
Do not transmit start/stop characters
F1
Transmit start/stop characters as ABCD/TN*E
F2
Transmit start/stop characters as abcd/tn*e
F3
Transmit start/stop characters as ABCD/ABCD
F4
Transmit start/stop characters as abcd/abcd
F5
Transmit check digit
F6
Do not transmit check digit
F7
Do not calculate check digit
F8
Calculate check digit (Modulo 10)
F9
Calculate check digit (Modulo 16) (AIM specifications)
FB
Calculate check digit (Modulo 7)
-[8-8L-8M-G1-G2-G3-G!-G5-G6-G7-G8-G9-G:-GCContinued on next page.....
32
Page 42
Appendix A - Programming Menus & Commands
V520-LHA7127
Codabar (NW-7 Format) Start Character A.... a.... A.... a....
1 to 42 data digits
Check digit
Stop Character ....T ....t ....A ....a
• Codabar (NW-7) has four different start/stop character schemes as shown above. The check digit is optional and, if present, would be the last character. • If the scanner is programmed to calculate the check digit and the bar code is not printed with a check digit, the bar code will not be read.
8. Options for 2 of 5 Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
G0
Do not calculate check digit
G1
Calculate check digit
G2
Transmit check digit
G3
Do not transmit check digit
7M
Enable 2 characters
7N
Disable 2 characters
-[8-H1- % -H2-H3-H!-8N-8O-
2 of 5 Format (Standard and Interleaved) 1 to 44 data digits numeric only (0 to 9)
CD Check digit
Omron strongly recommends that the “Fixing the Number of Digits” featured on page 35 be employed whenever 2 of 5 bar codes are used.
33
Page 43
Appendix A - Programming Menus & Commands
V520-LHA7127
9. Options for IATA Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
D2
Do not calculate check digit
D3
Calculate check digit (CPN + Form + Serial)
D4
Calculate check digit (Form + Serial)
D5
Calculate check digit (All data)
D6
Transmit check digit
D7
Do not transmit check digit
-[8-E3-E!-E5-E6-E7-E8-
The IATA code is a variable length symbology with an optional check digit and non-printable start/stop characters. The following characters are supported: Digits 0 up to 9. The checksum is calculated as the modulo seven of the data string. IATA is an acronym for International Air Transport Association. String format
CPN
AC
FC
SN
CD
Meaning of Acronym
Coupon
Airline Code
Form Code
Serial Number
Check Digit
1
3
2
8
1
Number of digits (15 total)
• Enable check digit check. • Selection of the check digit calculation. • Disable transmission of the check digit. Check digit calculation: If the check digit calculation is required, then the appropriate calculation method must be selected.
34
Page 44
Appendix A - Programming Menus & Commands
V520-LHA7127
10. Fixing the Number of Digits Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
7V
Enable fixation (1st Length)
7W
Enable fixation (2nd Length)
(H0)
Disable fixation
-[8-I2-I5-I1-
H2
Disable 1 character Code 39 and Codabar (NW-7); Disable 2 characters 2 of 5
-I3- %
H3
Enable 1 character Code 39 and Codabar (NW-7); Enable 2 characters 2 of 5
-I!-
To avoid truncation errors, the scanner can be programmed to only decode bar codes of one specific length, i.e., containing a specific number of digits. It is also possible to program the scanner to only decode bar codes of either of two specific lengths. To fix one (1) length (or number of digits) of bar code:
To fix two (2) different lengths of bar codes:
1. Scan “START” to enter the programming mode.
1. Scan “START” to enter the programming mode.
2. Scan “Enable fixation” bar code.
2. Scan “Enable fixation” bar code.
3. Scan a sample bar code of the desired length.
3. Scan a sample bar code of the desired length #1.
4. Repeat Step #3, re-scanning the sample bar code.
4. Scan a sample bar code of the desired length #2. 5. Scan “STOP” to exit the programming mode.
5. Scan “STOP” to exit the programming mode. Note Fixation can also be programmed using computer commands through your RS-232C by typing <ESC>7V<CR> followed by <+>2 digit length 1<CR>. 7W would be appropriate for length 2. Type <+>00<CR> to define either length as no fixed number. “Fixing the Number of digits” can only be applied to Code 39, Codabar (NW-7), 2 or 5 and MSI/Plessey. WPC, Code 39, IATA and Code 128 are not affected.
35
Page 45
Appendix A - Programming Menus & Commands
V520-LHA7127
11. Creating a Prefix and/or Suffix Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
1Y
Clear all Prefixes
-[8-2Z-
Z4
Display Prefix/Suffix value and length (expressed in hexidecimal format)
-[5-
The scanner can be programmed to transmit a prefix and/or suffix with the decoded data. A Prefix (or a Suffix) is composed of up to 4 characters. The following steps are used to establish a Prefix that will be transmitted with the bar code data: 1. Scan Start. 2. Scan the bar code representing the symbology to which you wish to add a Prefix. 3. Scan the character(s) that will comprise the Prefix. Up to four numeric, alpha or control character(s) may be used 4. Scan “STOP” to exit the Programming Mode. Example:
To add the alpha character “A” as a Prefix and “B” as a Suffix to UPC-A bar code data: 1. Scan “START/END Programming Mode.” 2. Scan N1, representing a Prefix for UPC-A. 3. Scan 0A, representing the alpha character “A.” 4. Scan N6, representing a Suffix for UPC-A. 5. Scan 0B, representing the alpha character “B.” 6. Scan “START/END Programming Mode.” Note The same steps are used to establish a Suffix.
36
Page 46
Appendix A - Programming Menus & Commands
V520-LHA7127
12. Setting Prefixes (Identifying the Symbology) Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
1Y
Clear all Prefixes
N1
UPC-A
M0
UPC-A +2 or +5
N2
UPC-E
M1
UPC-E +2 or +5
N3
EAN-13
M2
EAN –13 +2 or +5
N4
EAN-8
M3
EAN-8 +2 or +5
M4
Code 39
M5
Codabar (NW-7)
M6
Industrial 2 of 5
M7
Interleaved 2 of 5
-[8-2Z-O2-N1-O3-N2-O!-N3-O5-N!-N5-N6-N7-N8Continued on next page.....
37
Page 47
Appendix A - Programming Menus & Commands
V520-LHA7127
Setting Prefixes (Identifying the Symbology) (cont.) Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
M8
Code 93
M9
Code 128
D8
IATA
N0
MSI/Plessey
-[8-N9-N:-E9-O1-
Z4
Display Prefix/Suffix value and length (expressed in hexidecimal format)
-[5-
13. Setting Suffixes (Identifying the Symbology) Computer Command
Function/Description
Bar Code Command
(Z7)
START/END Programming Menu
1Z
Clear all Suffixes
N6
UPC-A
O0
UPC-A +2 or +5
N7
UPC-E
O1
UPC-E +2 or +5
N8
EAN-13
-[8-2[-O7-P1-O8-P2-O9Continued on next page.....
38