Page 31

SECTION 2

"

Getting Started

10” ROUTECOMMANDERR

4000 SERIES

11-1/2” Figure 2-15 Approximate Dimensions of Auxiliary Power Unit

10” ROUTECOMMANDERR

4000 SERIES

11-1/2” Figure 2-16 Approximate Dimensions of 4985 Network Controller 4985 Network Controller Programmer’s Guide

2-17

Page 32

SECTION 2

"

Getting Started

Location Avoid extreme temperatures or humidity. Plan your space carefully before you install the mounting brackets. Figures 2-15 through 2-17 show approximate dimensions of the controller, the APU, the multidock, and the single dock.

9-1/4” High

8-3/4” High

25-1/2” Long

5” Long 4950 Single Dock

4960 Multidock

Figure 2-17 Approximate Dimensions of Docks

Use graph paper to draw the installation to scale in your planning. "

"

Minimum required spacing between a 4985 Network Controller and a multidock is 19 and 3/4 inches. Plan for 39 and 1/4 inches of space. Minimum required spacing between two multidocks is 26 and 1/2 inches. Plan for 51 and 1/2 inches of space.

Locate the controllers and APUs within reach of properly grounded, 3-prong AC outlets. " NOTE:

Do not use extension cords with this equipment.

Brackets Install the system once you determine the location and plan the layout. Figure 2-18 illustrates a wall layout using a pencil, a carpenter’s rule, a 2-18

4985 Network Controller Programmer’s Guide

Page 33

SECTION 2

Getting Started

" chalk line, and a level. After installing each pair of brackets, mount the equipment item to ensure clearances between adjacent pieces. Clearance between bracket holes for second multidock 6”

9”

16”

9-1/2”

16”

2-1/8”

Bracket holes for 4985 Controller

Bracket holes for first multidock

Bracket holes for second multidock

Figure 2-18 Sample Wall Layout with Brackets

Install controller and APU brackets on 6-inch centers, using hardware appropriate to the mounting surfaces. Mount multidock brackets on 16-inch centers. You can mount these brackets on a vertical surface or wall (Figure 2-19).

Figure 2-19 Vertical or Wall-Mounted Bracket 4985 Network Controller Programmer’s Guide

2-19

Page 34

SECTION 2

"

Getting Started

These brackets have two holes on the lower arm for mounting on to a horizontal surface, such as a countertop or table. When mounting on a horizontal surface, use at least an 8-inch shelf depth (Figure 2-20).

Figure 2-20 Horizontal or Shelf-Mounted Brackets

The controller, APU, and multidock all have pairs of large rivets welded to the back frame or cover. These rivets go in the mounting bracket keyholes, then slide down to lock the equipment securely in place.

Connectors Multidock connectors (on each end) are identical and interchangeable. There is not an input or an output connector. Use the most convenient connector available on the multidock when connecting it to the controller, an APU, or when chaining to another multidock.

2-20

4985 Network Controller Programmer’s Guide

Page 35

SECTION 2

"

Getting Started

2 3

1

4 LAN

HOST/MODEM

RS485

RS232

RESET

CONFIG SWITCHES

5 15V INPUT 3.5A

1. Multidock 2. Host or modem 3. Reset switch 4. Configuration switch 5. Power connector

Figure 2-21 Connectors on the Back of a 4985 Network Controller

" NOTE:

You can connect up to two multidocks. Add another APU if you want another multidock. You need special adapters for a single dock.

AC Power Use alternating current (AC) power for data communication equipment with isolated ground outlets. Properly installed isolated ground outlets and wiring produce a relatively ElectroMagnetic Interference (EMI) or noise free environment. This ensures proper operation of sensitive electronics such as computers and telecommunications devices.

4985 Network Controller Programmer’s Guide

2-21

Page 36

SECTION 2

"

Getting Started

1 5

2

4

3 1. Insulated from each other by design 2. Insulated ground wire 3. “Neutral” wire (white, insulated) 4. Conduit, box, metal wallplate (provides “Safety Ground”) 5. Orange triangle

Figure 2-22 Isolated Ground Outlets

An Isolated Ground (IG) installation requires special outlets such as General Electric catalog number 8200-IG2 (15 amp) or 8300-IG2 (20 amp). Wire these per applicable standards, such as National Electrical Code paragraph 250-74, (exception #4). A separate, insulated ground wire must be run, uninterrupted, from the outlets and terminate directly at an equipment grounding conductor terminal of the derived system or service.

2-22

4985 Network Controller Programmer’s Guide