Page 23

SECTION 2

"

Getting Started

Configuration information sent to the controller from the host is sent in the system initialization record at the start of communication. The host can fine-tune the system and port configurations to meet the needs of a particular communications session.

Device Channels Some things to remember: "

" "

A logical channel number and record type prefix all controller data. HHC data is in a contiguous sequence on a logical channel. The host telecommunications program must maintain state variables and file pointers indexed by the logical channel number.

Help The controller runs several self-diagnostic programs during power-up, ensuring the equipment is in normal working order. If a problem during power-up, the controller beeps several times and the unit does not operate. The most common problems are often easiest to detect, and in many cases, correct. These include loose cable connections, loss of AC power, bad or no telecommunication, and sometimes faulty equipment. The HHC display sometimes helps to diagnose a problem.

Beeping The controller performs a series of power-up self-tests each time it powers on. A single beep indicates that all power-up tests passed. Two beeps indicate the host port has reset and is ready to communicate. A long beep or a short pattern of beeps repeating for longer than 30 seconds indicate a problem with the internal hardware. The unit must go to a service center for repair. These beeps are diagnostic tools for the service technician. See Appendix A for a list of beep counts and their problem areas. 4985 Network Controller Programmer’s Guide

2-9

Page 24

SECTION 2

"

Getting Started

Connections During the installation and startup testing, the system should have made all connections to the controller and its peripherals. If problems do occur, ensure that the system has fully seated connectors. Ensure that power connections are attached securely to wall outlets.

Testing Diagnostics can run through a command interpreter on the RS-232 port using an attached ASCII terminal. These tests require a technician to access the highly technical test findings.

Modem Indicator Modems frequently have LEDs to show events as they happen. If a LED should light but does not, the modem manual and this information can help determine where the trouble exists. The modem could be bad, or the connections to either the controller or to the telephone lines could be defective. The modem indicators, if any, can help isolate a telecommunication (TCOM) problem.

Cleaning Periodic cleaning maintain the appearance and reliability of the controller. When cleaning, inspect for damage or wear. Clean the controller with a soft cloth dampened with a quality glass cleaner. Do not use sol vent solutions.

Specifications Communication Protocol Support: RS-232 RS-485 2-10

Secondary ADCCP (9.6Kbps) or Host Async (38.4Kbps) NPCP (500Kbps)

4985 Network Controller Programmer’s Guide

Page 25

SECTION 2

"

Getting Started

Environmental:

Operating temperature: 32° to 122° Fahrenheit 0° to 50° Celsius

Memor y:

512K Internal RAM 128K Internal ROM

Microprocessor:

80C186 @ 8 MHz

Physical:

Height: Width: Depth: Weight: Chassis:

Power Capacity:

12 HHCs maximum

Power Supply:

External:

Serial Interfaces:

RS-232 RS-485

9.5 inches (241 mm) 13 inches (330 mm) 7.5 inches (191 mm) 5 lbs 0.063 inch-thick (1.6 mm) #5052H32 aluminum +15 Volts @ 3.5 Amps 1 port 1 port

Hardware B CAUTION:

Applying cleaners directly to any part of the controller will damage the controller. Do not use alcohol, benzene, carbon tetrachloride, or any other solvents to clean any portion of the controller. Use a soft, lint-free cloth moistened in a quality glass cleaner to clean the exterior of the controller.

B CAUTION:

Using the controller in an hostile environment that includes temperature extremes or where moisture can enter the unit will damage the controller. Operate the controller indoors, sheltered from precipitation.

" NOTE:

Ensure that a properly wired, isolated-ground AC outlet powers the power supply for the controller. Properly installed isolated ground outlets and wiring produce a relatively ElectroMagnetic Interference (EMI) or noise free environment. This ensures proper operation of sensitive electronics such as computers and telecommunications devices.

Unpacking Equipment Inspect the shipping containers for signs of damage before unpacking the equipment. If any damage, you must immediately report that fact to the carrier. 4985 Network Controller Programmer’s Guide

2-11

Page 26

SECTION 2

"

Getting Started

Remove equipment and materials from the shipping containers and examine all items to become familiar with their physical characteristics. Check for signs of damage before you proceed. Install mounting brackets in pairs, on 6-inch centers for the controller and the Auxiliary Power Unit (APU), and on 16-inch centers for the multidocks. We do not provide mounting hardware. Use 1/4-inch hardware suitable for your wall or mounting surfaces (such as concrete block, poured concrete, drywall, plywood, sheet-metal, countertop, shelving, or a table).

LAN

HOST/MO-

RS485

DEM RS232

RESET CONFIG SWITCHES

ROUTECOMMANDERR

4000 SERIES

15 INPUT V 3.5 A

Front

Back Figure 2-10 4985 Network Controller

General Equipment The controller interfaces between a group of HHCs and another controller, or a larger computer, such as a PC or mainframe. It is a lowcost controller for remote networks supporting 12 or fewer HHCs. At each remote site, a controller connects to the HHCs by cables and a peripheral device, such as multidock or single dock. In turn, the controller connects to other network controller devices, a PC, modems, or a larger computer (host site) through cables or telephone link. 2-12

4985 Network Controller Programmer’s Guide

Page 27

SECTION 2

"

Getting Started

This provides flexible, software-controlled 2-way communication of data, messages, and program changes between a host computer and many HHCs. The controller acts as a buffer (temporary storage) and control device to ensure orderly communication and minimal errors. The controller provides communication power and charging voltage for up to twelve 4000 Series HHCs. Add an APU to expand the network beyond the power supply capabilities of the controller. Connect up to two APUs and ten multidocks in series to one 4985 Network Controller.

Optional Peripherals Optional peripheral devices allow for flexibility and customization: Single Dock

Figure 2-11 4950 Single Dock

The 4950 Single Dock accommodates one HHC. Use the single dock under specific restrictions. Special consideration for system power is required. See your Norand Systems Engineer for details.

4985 Network Controller Programmer’s Guide

2-13

Page 28

SECTION 2

"

Getting Started

Multidock

Figure 2-12 4960 Multidock

Chain the 4960 multidocks together with cables to increase the number of HHCs connected to each controller. Each rack has six docks for the 4000 Series HHCs.

2-14

4985 Network Controller Programmer’s Guide

Page 29

SECTION 2

"

Getting Started

Auxiliary Power Unit (APU)

Figure 2-13 Auxiliary Power Unit

Place an APU in the network after the first two multidocks, before the next group of four multidocks. The APU furnishes charging current to the next group of multidocks and also strengthens signals on the communication lines to ensure reliable, error-free data transmission in both directions. There can be a maximum of two APUs and ten multidocks.

4985 Network Controller Programmer’s Guide

2-15

Page 30

SECTION 2

"

Getting Started

Power Supply

Insert your power cord from standard outlet plugs here.

Connect the network controller to this power supply outlet.

Figure 2-14 Power Supply Placement and Connectors

Place the power supply on the attached mounting shelf located at the back of the controller. Modems Limit the modem configuration to support these two modems: NORAND NM2400A and NORAND 9600. Enter remote auto-dial phone numbers into the NORAND modems. Use the NORAND 9600 Modem front panel to enter the numbers. Use an RS-232 terminal to enter the phone numbers into an NM2400A. Refer to the operation documents for your modem before entering phone numbers into the modem.

2-16

4985 Network Controller Programmer’s Guide