Page 37
Section 3 Installation "
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
Start Up Operations Start-up normally takes less than one minute. At the time of initial installation, configure the controller for the system in which it operates. Three banks of Data Input (DI) switches are for functional configuration of the controller. Each bank contains eight switches. "
"
"
" NOTE:
Bank 1: Defines host port communication type: ASYNC or Secondary ADCCP. If the host type is ASYNC, the host port parameters are: parity, data bits, speed, and channel ID. Bank 2: Functions include modem configuration, auto-answer, auto-dial, and a number of HHCs allowed to transmit concurrently. Bank 3: Defines identity code of the controller in a system configuration. Controller identification consists of a 3-digit number between “000” and “254.” There are 256 unique identity codes. The default ID is zero.
ID number 255 is reserved.
Model 4985 Network Controller Programmer’s Guide
3-1
Page 38
SECTION 3
"
Installation
Table 3-1 Bank 1 Dip Switches
Dip Switch Meaning
Description
1
Command mode off: Normal host communications. on: Controller powers up in command mode and awaits input commands from user on the RS-232 port. Provided as a diagnostic tool.
2
Host type
Specifies which host type is active. off: Secondary ADCCP on: Asynchronous host
3-5
Speed (bps)
ADCCP uses external clocking. 3
4
5 speed off off off : 19200 bps (default) on off off : 1200bps off on off : 2400bps on on off : 4800bps off off on : 9600bps on off on : 19200bps off on on : reserved on on on : reserved 6
Parity
ASYNC host only off: No parity on: Even parity
7
Databits
ASYNC host only off: 8 data bits on: 7 data bits
8
3-2
Reserved
Model 4985 Network Controller Programmer’s Guide
Page 39
SECTION 3
"
Installation
Table 3-2 Bank 2 Dip Switches
Dip Switch Meaning
Description
1
Modem (Secondary ADCCP host only) configure flag off: Controller auto-senses the modem type before configuring the attached NM2400A or NORANDâ 9600 Modem. on: Attached modem is not configured.
2-3
Autodial select (see Note 1 after table)
(Secondary ADCCP host only) Specifies which number stored in the attached modem to dial when a terminal is ready to communicate. off off: Autodial off on off: Dial stored number 1 off on: Dial stored number 2 on on: Alternate between stored number 1 or 2. The controller switches to the other number stored in the modem whenever a dial operation fails.
4
Force autoanswer (see Note 2 after table)
(Secondary ADCCP host only) off: Controller answers the phone only when a HHC is ready to communicate. on: Controller always answers the phone.
5
Skip modem reset off: Controller sends an AT&F command to modem before modem is configured. on: Controller does not reset the NORAND Modem to factory default settings.
6
Reserved
7-8
Number of logical channels on the LAN port. (see Note 3 after table)
This number equals the number of HHCs that can be active concurrently. off off: 1 channel active on off: 2 channels active concurrently off on: 3 channels active concurrently on on: Reserved
Model 4985 Network Controller Programmer’s Guide
3-3
Page 40
SECTION 3
" NOTE 1:
"
Installation
If enabled (autodial switches 2 and 3) and the Modem Configure Flag (switch 1) is “on”, the controller uses the Hayes command string “ATE0V0” to configure the modem and “ATDS” or “ATDS2” to dial. Also, if enabled, the controller will attempt to dial the host at power-up. This is useful for loading boot files into the controller during the initial power-up.
" NOTE 2:
If you wish the host computer to dial the controller to load boot files, you may perform the following steps: 1. Set Force autoanswer to “on.” 2. Press the reset button to purge files stored in the controller. 3. Download the boot files to the controller. 4. When finished, set Force autoanswer to “off.” 5. Power-off the controller for 30 seconds (resets controller to original configuration).
" NOTE 3:
If you change the switch settings after the controller is powered on, you must either power off the controller for 30 seconds and power it back on, or press the reset switch. This action reconfigures the controller according to the new switch settings.
" NOTE:
Pressing the reset button will erase all boot and other files from the controller’s memory. Table 3-3 Bank 3 Dip Switches
Dip Switch Meaning
Description
1-8
Default ID is 49850000.
Controller ID
These switches set an 8-bit number from hex “00” to “FF.” The 8-bit number translates to an ASCII decimal number sent to the host at the beginning of a host-to-controller session. The host may use the number to uniquely identify the controller. The host needs the ID to maintain the HHC boot file on the controller. The ID sent to the host will range from “49850000” to “49850254,” where the last three digits come from the switch settings and the first five digits are the device type. 3-4
Model 4985 Network Controller Programmer’s Guide
Page 41
SECTION 3
"
Installation
Figure 3-1 shows the switch settings for an ID equal to “0000 0000.” The following is another way of representing the ID setting of zero: “off” “off” “off” “off” “off” “off” “off” “off.” The notation “off” and “on” represent the individual switch settings. Zero represents “off” and “1” represents “on” (such as 0000 0000). O 1 2 3 4 5 6 7 8 N
Figure 3-1 Default Switch Settings
Reset Button " NOTE:
You should always request permission from your data processing department before pressing the reset button. Pressing this button erases the files needed to “boot” the HHCs.
File System The controller supports a nonvolatile file system. This file system stores 4000 Series HHC boot files, program files, and data files. Files downloaded to the controller are backed up for a minimum of one hour after the controller loses power. After that time, they could corrupt. Press the reset button before you download the files to the controller. Download files from a host computer. For specific instructions on maintaining files with a host program application refer to the related publications listed below: 4980 Programmer’s Guide 4920 and 4921 User’s Guide Volume A Volume B 4920 and 4921 Reference Guide
NPN: 977-028-001 NPN: 961-021-011 NPN: 961-021-012 NPN: 961-021-013
Model 4985 Network Controller Programmer’s Guide
3-5
Page 42
SECTION 3
3-6
"
Installation
Model 4985 Network Controller Programmer’s Guide