Page 31

SECTION 2

"

Features and Functional Overview

Hardware Components Figure 2-4 shows 6710 Mobile Bridge components, described on the following pages. Not shown is the mounting bracket, which attaches the 6710 Mobile Bridge to a wall. 1

2

3

4

6 5

7

10 BASE 2

8

10 BASE T

9

AUI

DIAG

AC INPUT 100/240 VAC

Figure 2-4 Hardware Components

1. Protective cover. The cover protects two RS-485 PC card slots. 2. Connectors (9-pin, D-sub female) for RS-485 PC cards. 6710 Mobile Bridge User’s Guide

2-13

Page 32

SECTION 2

"

Features and Functional Overview

3. Indicator lights. Four pairs of indicator lights (LEDs) on the front panel show the 6710 Mobile Bridge’s status. During the power-up sequence, the lights show the results of the power-up self diagnostics and provide information about the operating status. After the power-up sequence, the lights show the current operating status and indicate if a problem exists. The lights are described in detail in Section 6, “Indicator Lights.” 4. Rubber feet. Four nonskid rubber feet provide a stable base for the 6710 Mobile Bridge when you place it on a desktop or other horizontal surface. When the mounting bracket is installed for a 6710 Mobile Bridge mounted vertically, the rubber feet provide a small amount of tension to the bracket to help hold it in place. 5. AC INPUT. The AC INPUT connector is a standard IEC type, three-prong AC input connector. The power cord attaches to this connector. The internal power supply is an autosensing international power supply. It accepts a source voltage between 85 and 264 V ac, with a frequency between 47 and 63 Hz. 6. 10 BASE 2. The 10 BASE 2 port is a standard BNC port through which the 6710 Mobile Bridge connects to 10BASE2 Ethernet (thinnet). 7. 10 BASE T. The 10 BASE T port is a standard RJ45 port through which the 6710 Mobile Bridge connects to 10BASE-T (UTP) Ethernet. 8. AUI. The AUI port is a 15-pin, D-subminiature (D-sub) port. The 6710 Mobile Bridge connects to an AUI network adaptor through this port, for connection to 10BASE5 Ethernet (thicknet). Pin definitions are in Appendix B, “Port and Cable Pin-Outs.” " NOTE:

2-14

Instructions for connecting the 6710 Mobile Bridge to 10BASE2, 10BASE5, and 10BASE-T are in Section 3, “Installation.”

6710 Mobile Bridge User’s Guide

Page 33

SECTION 2

"

Features and Functional Overview

9. DIAG. The DIAG port is a 9-pin D-sub communication port that communicates at RS-232 levels. Use this port to configure the 6710 Mobile Bridge, download new software, and retrieve statistics. Pin definitions are in Appendix B.

Accessories Power Cord The power cord connects the 6710 Mobile Bridge to the wall outlet. The following chart lists power cord part numbers. Country

Part Number

Australia

321-472-001

Denmark

321-501-001

Europe

321-473-001

Italy

321-471-001

Germany

321-515-001

United Kingdom

321-474-001

United States

321-054-001

Industrial Locking Mounting Bracket The Industrial Locking Mounting Bracket (P/N 203-386-001) “locks” the 6710 Mobile Bridge into the bracket. This bracket is recommended for installations where vibration, shaking, or other movement can dislodge the 6710 Mobile Bridge from its mount.

6710 Mobile Bridge User’s Guide

2-15

Page 34

SECTION 2

2-16

"

Features and Functional Overview

6710 Mobile Bridge User’s Guide

Page 35

Section 3

Installation "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

This section describes how to do the following: Check the 6710 Mobile Bridge’s default configuration. " Prepare for the installation.

"

Collect the networking equipment you need. " Select the best location for the 6710 Mobile Bridge. "

"

Connect the 6710 Mobile Bridge to PEN*KEYR multidocks.

Checking the Default Configuration The 6710 Mobile Bridge is shipped with default settings for system software parameters, which are listed in Section 4, “Configuration.” You may need to change some default settings to achieve a more efficient configuration for your site. For information about reconfiguring the 6710 Mobile Bridge, see Section 4. The device should be properly configured before it is connected to the RS-485--Ethernet LAN.

6710 Mobile Bridge User’s Guide

3-1

Page 36

SECTION 3

"

Installation

Preparing for the Installation Unpack the 6710 Mobile Bridge and inspect it for damage or missing parts. Save all the paperwork you received. If the 6710 Mobile Bridge appears to be damaged, contact the Customer Response Center for instructions on returning the device for replacement. The shipment contains the 6710 Mobile Bridge with FLASH and the following items: Mounting bracket " AC power cord " Warranty card "

Collecting the Equipment Before you install the 6710 Mobile Bridge onto the network, collect the equipment you will need.

RS-485 LAN Components The 6710 Mobile Bridge connects to the following PEN*KEY computer multidocks through a nonpowered RS-485 LAN cable: PEN*KEY 6100 Series Multidock (for PEN*KEY 6100 and 6110 Computers). " 4960 Multidock (for PEN*KEY 6210 Computers). The multidock requires an external power supply and Y-cable P/N 226-151-001. Table 3-1 lists recommended lengths for the nonpowered RS-485 LAN cable (P/N 226-103-0XX, where “0XX” is the cable length). "

3-2

6710 Mobile Bridge User’s Guide

Page 37

SECTION 3

"

Installation

Table 3-1 Nonpowered RS-485 LAN Cable Lengths Cable Length

P/N

1.5 feet

226-103-002

6 feet

226-103-004

10 feet

226-103-005

20 feet

226-103-006

50 feet

226-103-009

100 feet

226-103-014

200 feet

226-103-019

500 feet

226-103-028

1000 feet

226-103-038

Ethernet LAN Components The 6710 Mobile Bridge directly connects to 10BASE2, 10BASE-T, or 10BASE5 Ethernet medium. Consult a cabling reference for maximum run lengths and node limits for Ethernet wiring.

10BASE2 Components 10BASE2 components include a T-connector, a cable terminator, and the proper lengths of 10BASE2 coax cable. The 10BASE2 T-connector (Figure 3-1) attaches to the 6710 Mobile Bridge’s 10BASE2 port, and connects the device to the middle or end of 10BASE2 cable.

Figure 3-1 T-Connector

6710 Mobile Bridge User’s Guide

3-3

Page 38

SECTION 3

"

Installation

A cable terminator (Figure 3-2) attaches to the T-connector. It is required for a device connected to the end of 10BASE2 cable. The terminator properly terminates the network cable to maintain proper impedance. Proper termination is necessary for reliable Ethernet operation.

Figure 3-2 Cable Terminator

10BASE-T Component 10BASE-T coax cable normally connects the 6710 Mobile Bridge to an Ethernet hub. The cable has an RJ45 plug on each end (Figure 3-3).

Figure 3-3 Cable With RJ45 Plugs

10BASE5 Components 10BASE2 components include the proper lengths of 10BASE5 coax cable, an AUI drop cable (less than or equal to 50 feet/15 meters long), and a transceiver. Two types of transceivers are the intrusive N-Series transceiver and the nonintrusive vampire tap. The N-Series transceiver (Figure 3-4) is a T-shaped connector with a 15-pin AUI port and two type N connectors. This transceiver is intrusive because network service is disrupted while the coaxial cable is cut and a threaded N-series connector placed on each end of the cable. 3-4

6710 Mobile Bridge User’s Guide

Page 39

SECTION 3

"

Installation

A 10BASEF (fiber optic) adapter may be attached directly to the AUI connector.

Figure 3-4 N-Series Transceiver

The vampire tap is an insulation-piercing clamp device that clamps onto the coaxial cable (Figure 3-5). The vampire tap pierces the coaxial cable’s insulation and makes contact with the shield and inner conductor without cutting the cable.

Figure 3-5 Vampire Tap

6710 Mobile Bridge User’s Guide

3-5

Page 40

SECTION 3

"

Installation

Communication Equipment You can access the 6710 Mobile Bridge’s system software configuration menus locally through the DIAG port, or remotely through a Telnet session or Web browser.

Local DIAG Port Access For local access, you need the following: Third-party communications software terminal emulation package with Y-modem capability (such as PROCOMM PLUS by DataStorm Technologies, Inc.). Install the program according to its user guide. " PC (personal computer) station, which should meet the requirements outlined in the user guide for the terminal emulation program. " Cable to connect the PC to the 6710 Mobile Bridge’s DIAG port. The following chart lists cables.

"

For this PC Port

Use Cable Part Number

9-pin 25-pin

226-106-001 (null modem cable) 321-355-001

Telnet You need the following to access the configuration menus through a Telnet session: PC or workstation with an installed and configured network interface card and a Telnet application. You can also use a host capable of acting as a Telnet client. " Telnet VT emulator (TNVT) installed on the PC. " IP address for the 6710 Mobile Bridge. For more information about IP addresses, see Section 4.

"

3-6