The text of a manual · part 5 of 24
6710 Mobile Bridge User's Guide, pages 41 to 50
Pages 41 to 50 of 236
The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Norand 6710
Page 41
SECTION 3
"
Installation
Web Browser The 6710 Mobile Bridge’s configuration menus are designed for HTML Level 2.0 or higher. You need the following to access the configuration menus through a Web browser: "
Graphical browser application
"
Internet or local network connection
"
IP address for the 6710 Mobile Bridge
Network Management Platform To manage the system through a network management platform, you need the platform (such as OpenView for Windows by Hewlett-Packard) installed on a network management station using SNMP. The station must meet the requirements outlined in the platform’s user guide.
Selecting the Best Location Factors related to the intended use of the system dictate installation practices. The following general practices should be followed in any installation: "
"
"
Locate the 6710 Mobile Bridge in the same area as other networking equipment, such as routers and hubs. Position the 6710 Mobile Bridge so its indicator lights are visible. The lights are useful for troubleshooting the installation. Install Ethernet LAN cabling within node limit and cable length limitations. Consult a cabling reference for maximum run lengths and node limits for Ethernet wiring.
6710 Mobile Bridge User’s Guide
3-7
Page 42
SECTION 3
"
Installation
"
"
Ensure a power outlet is within 6 feet of the 6710 Mobile Bridge. An uninterruptable power supply is recommended when the ac power system is not reliable. Ensure that the RS-485 LAN cabling, Ethernet LAN cabling, and ac power cord can reach the 6710 Mobile Bridge after you install it. Leave sufficient room around the 6710 Mobile Bridge so you can easily attach and remove cables.
Mounting the 6710 Mobile Bridge You can mount the 6710 Mobile Bridge horizontally on a tabletop, or vertically on a wall or post.
Horizontal (Tabletop) Mount 1. Remove the mounting bracket from the bottom of the 6710 Mobile Bridge. The bracket is not needed for a tabletop installation. 2. Set the 6710 Mobile Bridge in position. The device rests securely on four rubber feet that keep it from slipping out of place. 3. Make all RS-485 connections. See “Connecting to a Single Multidock” on page 3-11, or “Connecting to Two Multidocks” on page 3-12. 4. Make all Ethernet connections. See “Connecting to Ethernet” on page 3-13. 5. Make all power connections. See “Applying Power” on page 3-19. 6. Watch the indicator lights to verify that the 6710 Mobile Bridge is working properly. For help, see Section 6, “Indicator Lights.” 3-8
6710 Mobile Bridge User’s Guide
Page 43
SECTION 3
"
Installation
Vertical Mount See Figure 3-6 and the procedure following it. " NOTE:
If mounting the 6710 Mobile Bridge on a hollow wall, secure the mounting plate to a 3/4” (thick) plywood base by four 1” x 1/4” nuts, bolts, and washers. Anchor the plywood base to two separate wall studs by four 2” x 1/4” diameter lag screws (two lag screws in each stud). 6.00” 1.00” 2.00”
1.00”
2.00”
1.00”
Figure 3-6 Mounting Bracket
6710 Mobile Bridge User’s Guide
3-9
Page 44
SECTION 3
"
Installation
1. Inspect where the 6710 Mobile Bridge will be mounted and determine what hardware is needed. Different surfaces such as drywall, wood, and concrete block require different mounting hardware. For this reason, a universal mounting bracket is included with the 6710 Mobile Bridge. 2. Remove the mounting plate from the bottom of the 6710 Mobile Bridge. 3. Using the mounting plate as a template, mark where the anchors that secure the mounting plate to the surface should be located. 4. Attach the 6710 Mobile Bridge mounting plate to the wall with 2I x 1/4I diameter lag screws or bolts, depending upon the surface. The mounting plate must be secured to the surface by at least four anchors, one on each corner. 5. Reattach the 6710 Mobile Bridge to the mounting plate. 6. Connect the 6710 Mobile Bridge to the PEN*KEY multidock. To connect to a single multidock, see page 3-11. To connect to two multidocks, see page 3-12. 7. Make all Ethernet connections. See “Connecting to Ethernet” on page 3-13. 8. Make all power connections. See “Applying Power” on page 3-19. 9. Watch the indicator lights to verify that the 6710 Mobile Bridge is working properly. For help, see Section 6, “Indicator Lights.” " NOTE:
3-10
An optional locking kit is available. For more information about the kit, see Section 2, “Features and Functional Overview.”
6710 Mobile Bridge User’s Guide
Page 45
SECTION 3
"
Installation
Connecting to a Single Multidock To connect the 6710 Mobile Bridge to a PEN*KEY computer multidock, see Figure 3-7.
RS-485
PORT 2
PORT 1
6710 Mobile Bridge (Top Panel)
RS-485 LAN Cable (P/N 226-103-0XX)
To PEN*KEY Computer Multidock
Figure 3-7 Connecting to a PEN*KEY Computer Multidock
For PEN*KEY multidock installation instructions, refer to the following publications: To connect to the PEN*KEY 6100 Series Multidock (for PEN*KEY 6100 and 6110 Computers), refer to the 6100 Series Dock Installation Instructions (P/N 962-020-003). " To connect to the 4960 Multidock (for PEN*KEY 6210 Computers), refer to the RS-485 LAN with 4000 Series, 6200, and 6210 Computers Site Preparation Guide (P/N 961-028-097).
"
6710 Mobile Bridge User’s Guide
3-11
Page 46
SECTION 3
"
Installation
Connecting to Two Multidocks To connect the 6710 Mobile Bridge to two PEN*KEY computer multidocks, see Figure 3-8.
RS-485 PORT 2
PORT 1
6710 Mobile Bridge (Top Panel)
RS-485 LAN Cable (P/N 226-103-0XX)
To PEN*KEY Computer Multidock
To PEN*KEY Computer Multidock
Figure 3-8 Connecting to Two PEN*KEY Computer Multidocks
For PEN*KEY multidock installation instructions, refer to the following publications: To connect to the PEN*KEY 6100 Series Multidock (for PEN*KEY 6100 and 6110 Computers), refer to the 6100 Series Dock Installation Instructions (P/N 962-020-003). " To connect to the 4960 Multidock (for PEN*KEY 6210 Computers), refer to the RS-485 LAN with 4000 Series, 6200, and 6210 Computers Site Preparation Guide (P/N 961-028-097).
"
3-12
6710 Mobile Bridge User’s Guide
Page 47
SECTION 3
"
Installation
Connecting to Ethernet The following pages show how to connect the 6710 Mobile Bridge to 10BASE2, 10BASE5, and 10BASE-T Ethernet.
10BASE2 Ethernet The 6710 Mobile Bridge connects to the end or middle of the 10BASE2 cable segment. " NOTE:
Cable lengths between network devices on the 10BASE2 Ethernet LAN must meet ANSI/IEEE standards.
End of Segment See Figure 3-7 and the procedure following it.
10 BASE 2
10 BASE T
DIAG
AUI
AC INPUT 100/240 VAC 1
2
3
1. Cable terminator (50 ohm) 2. T-connector 3. 10BASE2 cable
Figure 3-9 End of 10BASE2 Segment
6710 Mobile Bridge User’s Guide
3-13
Page 48
SECTION 3
"
Installation
1. Plug the T-connector (2) into the 10 BASE 2 port. 2. Plug one end of the Ethernet cable (3) into an open end of the T-connector. Align the notches in the cable end with the posts on the T-connector, push the cable in, and twist one-quarter turn. 3. Plug the cable terminator (1) into the other end of the T-connector.
Middle of Segment See Figure 3-10 and the procedure following it.
10 BASE 2
10 BASE T
DIAG
AUI
AC INPUT 100/240 VAC 1
2
1
1. 10BASE2 cable 2. T-connector
Figure 3-10 Middle of 10BASE2 Segment
1. Plug the T-connector (2) into the 10 BASE 2 port. 2. Plug one end of the Ethernet coaxial cable (1) into an open end of the T-connector. Align the notches in the cable end with the posts on the T-connector, push the cable in, and twist about one-quarter turn. 3. Plug the end of another Ethernet coaxial cable segment into the other open end of the T-connector. 3-14
6710 Mobile Bridge User’s Guide
Page 49
SECTION 3
"
Installation
10BASE5 Ethernet The 6710 Mobile Bridge connects to 10BASE5 through an N-Series transceiver or vampire tap. " NOTE:
Cable lengths between network devices on the 10BASE5 Ethernet LAN must meet ANSI/IEEE standards.
N-Series Transceiver See Figure 3-11 and the following procedure. 1. Attach one end of the drop cable (1) to the AUI port. 2. Route the drop cable to the 10BASE5 cable (4) and determine a suitable spot to cut the cable and attach the transceiver (3). 3. Attach the transceiver to the 10BASE5 cable, then connect the other end of the drop cable to the AUI port (2) on the transceiver.
Vampire Tap See Figure 3-12 and the following procedure. 1. Attach one end of the drop cable (1) to the AUI port. 2. Route the drop cable to the 10BASE5 cable and determine a suitable spot on the cable to attach the vampire tap (3). 3. Attach the vampire tap to the 10BASE5 cable, then connect the other end of the drop cable to the AUI port (2) on the tap.
6710 Mobile Bridge User’s Guide
3-15
Page 50
SECTION 3
"
Installation
10 BASE 2
DIAG
AUI
10 BASE T
AC INPUT 100/240 VAC
1
3 2
4 1. 2 3. 4.
Drop cable 15-pin AUI port N-Series transceiver 10BASE5 coax
Figure 3-11 N-Series Transceiver
3-16
6710 Mobile Bridge User’s Guide
4