Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 24

6710 Mobile Bridge User's Guide, pages 21 to 30

Pages 21 to 30 of 236

The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Norand 6710

Page 21

SECTION 2

"

Features and Functional Overview

Bridging Functionality General Concepts Bridges are common components in wired LANs. Bridges are devices that join two or more LAN segments. This provides the appearance of a single LAN segment to the protocols and applications that operate within the LAN. Bridges operate at the Media Access Control (MAC) sublayer of the Data Link Layer (Layer 2) of the International Organization for Standardization (ISO) protocol model. Operating at the MAC layer allows bridges to operate transparently to commonly used network protocols such as TCP/IP, Novell SPX/IPX, NetBEUI, and DECnet. In wired LANs, bridges do the following: Segment traffic for better efficiency and performance. " Extend the reach of LANs when cable length or node limits have been reached. " Translate between different LAN types. A LAN environment normally consists of a collection of nodes or stations, each identified by a unique 48-bit physical address (also called an IEEE address or MAC address). Data is sent on the LAN as frames or packets that contain the source address of the station sending the frame, and the destination address of the recipient station. "

A bridge has at least two ports, each connected to a different LAN segment. Bridges learn which source addresses are generating traffic on each of their ports. If the bridge receives a frame with a destination address corresponding to a source address it has seen on another port, it forwards the frame to the port.

6710 Mobile Bridge User’s Guide

2-3

Page 22

SECTION 2

"

Features and Functional Overview

If it receives a frame where the source and destination addresses are on the same port, it ignores (drops) the frame, since the destination node receives the original transmission. Generally, if a bridge receives a frame for an unknown destination address on any one port, it floods the frame on all other ports.

Bridging Layer The 6710 Mobile Bridge functions as a bridge with up to three ports: An Ethernet port " One or two RS-485 ports The 6710 Mobile Bridge is a translating bridge because it forwards frames between Ethernet and RS-485 wired media that have unique physical and MAC protocol implementations. The 6710 Mobile Bridge implements the basic learning and forwarding functions of a simple wired LAN bridge. "

Significant functions supported at the bridging layer include network organization and programmable flooding levels.

Network Organization 6710 Mobile Bridges automatically configure into a self-organized network using a spanning tree topology. They automatically reconfigure the network to maintain reliable operation as devices are added or removed, or in the event of some types of wired LAN failure. The spanning tree provides efficient, loop-free forwarding of frames through the network.

2-4

6710 Mobile Bridge User’s Guide

Page 23

SECTION 2

"

Features and Functional Overview

The spanning tree is initiated by the super root, a 6710 Mobile Bridge that coordinates the network and distributes common system parameters to other 6710 Mobile Bridges and RS-485 stations. The super root is elected from a group of 6710 Mobile Bridges designated at the time of installation. The election process also occurs in the event of a super root failure, preventing a single point of failure.

Forwarding The 6710 Mobile Bridge maintains a forwarding database of all physical station addresses known to it, and the correct port for each address. This database makes efficient forwarding decisions in the bridging software. The database is updated through monitoring addresses on each port.

Flooding Configurations Standard LAN bridges flood frames on all ports when the destination address is unknown. Additionally, many network protocols use multicast addressing for connection and status communications. A multicast frame is a special type of frame destined for more than one physical address. Standard bridges always flood multicast frames. All RS-485 media supported in the 6710 Mobile Bridge operate at slower media speeds than Ethernet. Indiscriminate flooding from a busy Ethernet backbone to an RS-485 medium can consume a substantial portion of the available bandwidth. This reduces system performance even though flooded frames are frequently not intended for stations on a given RS-485 segment. To allow performance tuning, the 6710 Mobile Bridge provides separate flooding control options for both unicast (single physical address) and multicast frames.

6710 Mobile Bridge User’s Guide

2-5

Page 24

SECTION 2

"

Features and Functional Overview

Certain ODI and NDIS drivers supplied with INTERMECR RS-485 PEN*KEY computers use the OWL_ATTACH protocol to provide reliable attach mechanisms. These mechanisms guarantee that the RS-485 stations are always in the 6710 Mobile Bridge’s forwarding database. Unicast flooding is never required for these stations.

Proxy ARP Server The Proxy ARP Server is an advanced flooding control capability for RS-485 stations using IP. An ARP (Address Resolution Protocol) is a type of multicast message used to determine the physical (MAC) address of a station using a specific IP address. When Proxy ARP is enabled, the IP addresses of RS-485 stations using IP are included in the forwarding database. If the destination IP address matches an entry in the forwarding database, the ARP is sent to the physical unicast address matching that IP address. To allow customization of this capability to optimize performance, the server operates in one of these modes: No flooding " Delayed flooding " Normal flooding Proxy ARP Server is discussed in more detail in Section 4, “Configuration.” "

Bridge Ports The 6710 Mobile Bridge has a physical Ethernet port and two RS-485 PC card slots.

2-6

6710 Mobile Bridge User’s Guide

Page 25

SECTION 2

"

Features and Functional Overview

Ethernet Port The Ethernet port can be configured to support 10BASE-T twisted pair, 10BASE2 thinnet, or an AUI connection. The AUI connection can support 10BASE5 thicknet or 10BASEF fiber optic connections with the appropriate media adapters. The physical connections are on the bottom panel of the 6710 Mobile Bridge. The desired Ethernet medium is selectable through the device configuration menus. More information about connecting the 6710 Mobile Bridge to Ethernet media is in Section 3, “Installation.” Instructions for setting the medium through the configuration menus are in Section 4, “Configuration.”

Ethernet Port Filters The Ethernet port can be configured to support a variety of custom input filters. 6710 Mobile Bridges are commonly installed on LANs to carry traffic between Ethernet and RS-485 devices. Setting filters prevents unnecessary traffic from the Ethernet LAN from being forwarded onto the RS-485 LAN. This is important because common RS-485 technologies operate at data rates below Ethernet speeds. Filters are set to pass frames likely used by RS-485 stations, and drop frames of a type which are known to not be used by stations requiring RS-485 connectivity. Filtering occurs in the Ethernet driver software that controls low level operation of the Ethernet ports, minimizing involvement of other functions when unnecessary frames are received. The default 6710 Mobile Bridge configuration sets no filters. Filter setup is discussed in more detail in Section 4, “Configuration.”

6710 Mobile Bridge User’s Guide

2-7

Page 26

SECTION 2

"

Features and Functional Overview

Filtering vs. Flooding Filtering and flooding control (described on page 2-5) are complimentary but have different functions. Filters allow frames to be eliminated based upon content of the frame, usually the network protocol header fields within the frame. For example, filters can be set to eliminate some or all IP traffic or Novell IPX traffic. Filtering occurs regardless of whether the destination address is in the forwarding database. Using filters can improve the performance of the 6710 Mobile Bridge and prevent undesired frames from being forwarded to RS-485 stations connected to it. Flooding decisions are made after frames have been received on a port and filtered. Flooding settings determine how the 6710 Mobile Bridge forwards frames to destination addresses not in the forwarding database.

RS-485 Ports The two PC card slots are intended for RS-485 network interface cards (NICs) and are designated as NIC1 and NIC2. Internally, they are configured as Port 3 and Port 2, respectively. Configuration of individual RS-485 ports is discussed in Section 4, “Configuration.”

Configuration and Management Configuration The 6710 Mobile Bridge can be configured through a local RS-232 connection, or remotely through a TCP/IP connection. The 6710 Mobile Bridge includes a command monitor and menu driven configuration with online help.

2-8

6710 Mobile Bridge User’s Guide

Page 27

SECTION 2

"

Features and Functional Overview

The command monitor and file system configuration are contained in permanent read-only memory (ROM) within the 6710 Mobile Bridge, and can be accessed through the RS-232 diagnostics port even if software is not loaded in the device. Most 6710 Mobile Bridge functionality is provided by the software stored within the file system. Configuration parameters are stored in nonvolatile EEPROM memory, and are maintained in the event of power loss.

Diagnostics and Configuration Port An RS-232 configuration port is provided for direct access to the 6710 Mobile Bridge’s command monitor and configuration menus. Access through the diagnostics port is password-protected for security. The port uses a standard PC AT style cable, and operates at speeds up to 57.6 Kbps. Configuration using this port is described in Section 4, “Configuration.”

Remote Access Remote access is available over TCP/IP connections using Telnet or Hypertext Transfer Protocol (HTTP) for configuration management, and Simple Network Management Protocol (SNMP) for network management. TCP/IP

The 6710 Mobile Bridge supports remote access through a Request for Comments (RFC) compliant TCP/IP stack. Before initial usage, the stack must be configured with an IP address and an optional default router through the RS-232 diagnostics port. Alternatively, the 6710 Mobile Bridge may be configured with a Dynamic Host Configuration Protocol (DHCP) server name. The 6710 Mobile Bridge then obtains its IP address, default router, and subnet mask from a DHCP server. 6710 Mobile Bridge User’s Guide

2-9

Page 28

SECTION 2

"

Features and Functional Overview

DHCP Client

The 6710 Mobile Bridge contains a DHCP client, allowing it to receive an IP address over the network. The DHCP client supports temporary and permanent leases. It also accepts permanent leases from a Bootstrap Protocol (Bootp) server. For further detail on DHCP operation, see Section 4, “Configuration.” Telnet

Telnet may be used to access the 6710 Mobile Bridge’s configuration menus. The command interface is identical to the command interface through the diagnostics port. More information about access through Telnet is in Section 4. HTTP

The 6710 Mobile Bridge supports configuration using HTTP from a workstation equipped with a Web browser. Microsoft Internet Explorer or Netscape Navigator is recommended. More information about access through a Web browser is in Section 4.

Electronic Software Distribution The 6710 Mobile Bridge supports electronic software distribution, which allows software upgrades after installation. The 6710 Mobile Bridge provides a dual bank file system with one active bank and one inactive bank. It operates from the active bank, allowing software upgrades to be stored in the inactive bank. This enables upgrades to be loaded while the 6710 Mobile Bridge is operating. The upgraded software can be used immediately after downloading by swapping the active and inactive banks and rebooting. The 6710 Mobile Bridge can also be programmed to load the new software at a later time, such as after all 6710 Mobile Bridges have been upgraded or during a time of little system activity.

2-10

6710 Mobile Bridge User’s Guide

Page 29

SECTION 2

"

Features and Functional Overview

TFTP Client and Server

Software downloads are accomplished using the Trivial File Transfer Protocol (TFTP), another member of the IP suite. Each 6710 Mobile Bridge contains a TFTP client and server. The TFTP client allows the 6710 Mobile Bridge to obtain software updates from a TFTP server. The server can be a 6710 Mobile Bridge configured with the TFTP server enabled, or another network workstation with TFTP server capability. Scripting

The 6710 Mobile Bridge supports a scripting capability that automates most of the software download process. The script process can be configured in the 6710 Mobile Bridge through Telnet or SNMP. The script file is loaded into the 6710 Mobile Bridge through TFTP, similar to the software.

Network Management The 6710 Mobile Bridge is instrumented for network management, with variables defined in the Management Information Base (MIB). The MIB is SNMP V1 compliant. Management information can be accessed through the SNMP agent. The MIB may be ordered separately and compiled for any SNMP network management platform. For more information about network management, see Appendix C, “MIB.” Also consult the Norand Open Wireless LAN with HP OpenView for Windows User’s Guide (P/N 961-051-009).

6710 Mobile Bridge User’s Guide

2-11

Page 30

SECTION 2

"

Features and Functional Overview

Sample Network Configuration Figure 2-3 shows a sample network configuration where the components of a bridged system provide communication between a 10BASE-T--based host and PEN*KEY 6100 Computers on an RS-485 LAN. 2

3 1 6

4

5

1. PEN*KEY 6100 Computers (with TCP/IP stack and INTERMEC NDIS or ODI driver) in multidock 2. RS-485 LAN cable 3. 6710 Mobile Bridge 4. TCP/IP over 10BASE-T Ethernet 5. 10BASE-T Ethernet hub 6. Host

Figure 2-3 Sample Network Configuration

PEN*KEY 6110 Computers and PEN*KEY 6210 Computers are also supported. Note that PEN*KEY computer multidocks can be daisy-chained.

2-12

6710 Mobile Bridge User’s Guide