Page 91
SECTION 4
" NOTE:
"
Configuration
Frame Type
Description
DIX--IP--TCP Ports DIX--IP--UDP Ports SNAP--IP--TCP Ports SNAP--IP--UDP Ports
Primary Internet Protocol Suite (IP) transport protocols.
DIX--IP--Other Protocols SNAP--IP--Other Protocols
IP protocols other than TCP or User Datagram Protocol (UDP).
DIX--IPX Sockets SNAP--IPX Sockets 802.3--IPX Sockets
Novell NetWare protocol.
DIX--Other EtherTypes SNAP--Other EtherTypes
DIX or SNAP registered protocols other than IP or IPX.
802.2--IPX Sockets
Novell running over 802.2 LLC.
802.2--Other SAPs
SAPs other than IPX or SNAP.
Some IP protocol ports cannot be filtered because they are used for configuration and management of the 6710 Mobile Bridge. These include HTTP, Telnet, SNMP, and Internet Control Message Protocol (ICMP). Filters set for these protocols are ignored for the Ethernet frame type configured in the 6710 Mobile Bridge’s [Tcpip] menu.
Frame types have the following settings: Action Scope
<Pass> <Unlisted>
Setting
Description
Action
Defines how the frame is processed: Pass (default)
Frame is passed to the bridging function for further processing.
Drop
Frame is discarded.
6710 Mobile Bridge User’s Guide
4-37
Page 92
SECTION 4
"
Configuration
Setting
Description
Scope
Defines whether the action applies to all frames of this type, or is restricted to selected subtypes: Unlisted (default)
Applies only to subtypes that are not configured under [SubTypes 1] or [SubTypes 2].
All
Applies to all frames of this type. [SubTypes 1] and [SubTypes 2] settings for this frame type are ignored.
[SubTypes 1] The predefined subtypes in the [SubTypes 1] menu provide preconfigured filters that are useful in many networks. The values for these subtypes cannot be changed. Subtypes are:
DIX-ARP SNAP-ARP 802.2-IPX-RIP 802.2-IPX-SAP NNL NETBIOS 1 (through) 16
Action SubType <Pass> <DIX-EtherType> <Pass> <SNAP-EtherType> <Pass> <802.2-IPX-Socket> <Pass> <802.2-IPX-Socket> <Pass> <DIX-EtherType> <Pass> <802.2-SAP> (User-defined subtypes.)
Value 08 06 08 06 04 51 04 53 87 5b f0 f0
(User-defined subtypes.)
User-Defined Subtypes in [SubTypes 1] and [SubTypes 2] The value under user-defined subtypes allow individual protocol ports, sockets, or SAPs to be specified for each of the listed frame types. The filter takes action if either the source or destination fields in the frame match the specified port, socket, or SAP. A value of 00 00 denotes the subtype as Unlisted.
4-38
6710 Mobile Bridge User’s Guide
Page 93
SECTION 4
"
Configuration
Subtypes for [SubTypes 2] are: Action 1 <Pass> 2 <Pass> 3 <Pass> . . . 22 <Pass>
Subtype DIX--IP--TCP--Port DIX--IP--UDP--Port DIX--IP--Protocol DIX--IPX--Socket DIX--EtherType SNAP--IP--TCP--Port SNAP--IP--UDP--Port SNAP--IP--Protocol SNAP--IPX--Socket SNAP--EtherType 802.3--IPX-Socket 802.2--IPX-Socket 802.2--SAP " NOTE:
SubType <DIX-IP-TCP-Port> <DIX-IP-TCP-Port> <DIX-IP-TCP-Port>
Value 00 00 00 00 00 00
<DIX-IP-TCP-Port>
00 00
Value Port value in hexadecimal. Port value in hexadecimal. Protocol number in hexadecimal. Socket value in hexadecimal. Specify the registered DIX type in hexadecimal. Port value in hexadecimal. Port value in hexadecimal. Port value in hexadecimal. Socket value in hexadecimal. SAP in hexadecimal. To filter on both SAP and OUI (Organizationally Unique Identifier), use advanced filters. Socket value in hexadecimal. Socket value in hexadecimal. SAP in hexadecimal.
Port values may be entered in decimal by adding a period to the entry. For example, “23.” for port 23. The Value field displays the hexadecimal equivalent.
6710 Mobile Bridge User’s Guide
4-39
Page 94
SECTION 4
"
Configuration
[Advanced RX Filter] If you need more flexibility than that provided by [Normal RX Filter], you can use the tables for [Advanced RX Filter] to specify additional filters. Settings for [Advanced RX Filter] execute after those for [Normal RX Filter]. For example, if [Normal RX Filter] dropped a frame, the frame cannot be “undropped.” If [Normal RX Filter] passed a frame, [Advanced RX Filter] then executes. Specifying an advanced filter for [Advanced RX Filter] is more complicated than specifying one for [Normal RX Filter]. If possible, use [Normal RX Filter] to set filters. [Advanced RX Filter] options are: [Expressions] [Values]
[Expressions] Use [Expressions] to enter expressions used to match the patterns stored in pattern lists to consecutive bytes in received Ethernet frames. Settings for Expressions execute in sequence until a determination is made to pass or drop the frame, as follows: If the last Then listed in this table is Then Drop, the table’s default is an implied Else Pass. " If the last Then is Then Pass, the default is an implied Else Drop. The Value Table displays the filter expressions to be executed: "
4-40
6710 Mobile Bridge User’s Guide
Page 95
SECTION 4
ExprSeq Offset 1 0 2 0 3 0 . . . 22 0
Mask 0 0 0
0
Op
Value Id <EQ> <EQ> <EQ>
"
Configuration
Action 0 <And> 0 <And> 0 <And>
<EQ>
0 <And>
Filter expressions have the following settings: ExprSeq Offset Mask Op Value Id Action
0 0 <EQ> 0 <Pass>
ExprSeq
ExprSeq contains a sequence number that orders expressions in ascending order. It is a method of changing the sequence execution. The prompt is: Range is: 0..65535
The default is 0. Change these numbers as needed for reordering. After you save the changes (through the Write command), the statements are physically reordered and renumbered. Offset
This setting defines the offset in a received Ethernet frame to match the patterns. The prompt is:
6710 Mobile Bridge User’s Guide
4-41
Page 96
SECTION 4
"
Configuration
Range is: 0..65535
A frame matches a pattern list if the masked bytes at the specified offset in the frame match any of the masked patterns in the pattern list. The default is 0. Mask
This setting indicates the bits that are significant at the specified offset. The prompt is: Range is: 8 hex pairs
The default is “” (an empty string). The length of this mask determines the number of characters compared at the offset. If this field is “” (an empty string, the default), the length of the field is determined by the longest value in the Value Table with the matching Value Id. Op
Op is a memory comparison operator in the following chart.
4-42
Operator
Description
LT
Less than one value.
LE
Less than or equal to one value.
EQ (default)
Equal to any in the list.
NE
Not equal to any in the list.
GE
Greater than or equal to one value.
GT
Greater than one value.
6710 Mobile Bridge User’s Guide
Page 97
SECTION 4
"
Configuration
Value Id
The field at the specified offset is compared with values in the Value Table with the Value Id. The prompt is: Range is: 0..255
The default is 0. When using a comparison operator that requires a single value (LT, LE, GE, and GT), only the first value found will be compared. Action
The Action setting instructs the Ethernet driver and indicates what should happen when this expression is true. Settings are: And Pass Drop
Setting
Description
And
Instructs Ethernet driver to continue with the next simple expression, if the expression condition is satisfied. Two or more simple expressions are ANDed together to form a complex expression. Instructs Ethernet driver to accept the frame for further processing and pass the frame up to the bridging layer (the frame is not discarded).
Pass (default) Drop
Instructs Ethernet driver to reject the frame.
6710 Mobile Bridge User’s Guide
4-43
Page 98
SECTION 4
"
Configuration
[Values] Use [Values] to enter pattern lists that contain byte patterns that match consecutive bytes in received Ethernet frames. Settings for [Values] are referenced by the Value Id from the Expression Table. The values to be used in a filter expression are as follows: Value Id 1 2 3 . . . 22
Value 0 0 0
0
Filter expression values have the following settings: Value Id Value
Setting
Description
Value Id
An identifier used by an expression in the Expression Table. The range is 0 (default) to 255. All values with the same identifier are considered to be in the same list. When used in an expression that allows only one value (that is, LT, LE, GE, or GT), only the first value in the list is used. One of the values to be compared. The range is 8 hexadecimal pairs.
Value
4-44
0
6710 Mobile Bridge User’s Guide
Page 99
SECTION 4
"
Configuration
RS-485 Options Use [B_B485] to set the baud rate of the RS-485 port: Baud Rate
<115200>
Options are: 115200 460800
The default is 115200K baud. Use the following chart as a guide to setting the baud rate. Stations
Baud Rate
PEN*KEYR 6210 Computers
115200
PEN*KEY 6100 Computers
115200
PEN*KEY 6110 Computers
115200 or 460800
Security Options Use [Security] to set these passwords: Password Service Password
“************” <Enabled>
Password This option is the top-level password you need to access the configuration menus. The prompt is: Range is: 16 chars
6710 Mobile Bridge User’s Guide
4-45
Page 100
SECTION 4
"
Configuration
Enter 16 or fewer alphanumeric characters for this password. It is case insensitive and can be any combination of letters, numbers, and symbols. For security, the password appears as asterisks on the screen.
Service Password Intermec maintains a service password so its Customer Response Center can configure this 6710 Mobile Bridge if necessary. For example, if you forget what the configuration menus’ top-level password is, the Customer Response Center can access the menus through the service password. By default, the Service Password is enabled. If setting a service password violates your security guidelines, you can disable it. If it is already disabled and you forget the configuration menus’ password, you may need to send this 6710 Mobile Bridge to a Service Center to be reconfigured. Contact the Customer Response Center for more information about the service password. See the Preface for contact information.
Creating a Web Browser Session " NOTE:
The 6710 Mobile Bridge’s configuration menus are designed for HTML Level 2.0 or higher.
Before you can configure the 6710 Mobile Bridge through a Web browser, you must connect the device to the Ethernet cable. (See Section 3, “Installation,” for help.) You must also perform initial configuration through the DIAG port to: Set an IP address or DHCP server name. You should also configure a subnet mask and IP router address. " Set the Ethernet cable type.
"
4-46
6710 Mobile Bridge User’s Guide