Page 81
SECTION 4
"
Configuration
1. Do all stations on the RS-485 LAN segment routinely transmit a frame at least once every 4 minutes? Answer
Settings
Yes
Inbound/Unicast/Disabled Outbound to Secondaries/Unicast/Disabled
2. Do any stations on the RS-485 LAN segment need to receive multicast or broadcast messages? Answer
Settings
No
Inbound/Multicast/Enabled Outbound to Secondaries/Multicast/Disabled
Note: TCP/IP stations must receive broadcast ARP frames. Comments:
The destination of a multicast frame is never known. The Disabled setting should be used for any network where RS-485 stations do not need to receive multicast frames. The Disabled setting can be used for secondary (RS-485) LANs that only need to receive ARP frames by enabling the ARP Server Mode to one of its flooding options (page 4-28). 3. Do stations on the RS-485 LAN segment communicate with other nodes on a different RS-485 LAN segment? Answer
Settings
Yes
Inbound/Unicast/Enabled Inbound/Multicast/Enabled
No
Inbound/Unicast/Primary Inbound/Multicast/Primary Outbound to Secondaries/Unicast/Disabled Outbound to Secondaries/Multicast/Disabled
6710 Mobile Bridge User’s Guide
4-27
Page 82
SECTION 4
"
Configuration
Comments: The Enabled settings facilitate peer-to-peer applications, where stations on one RS-485 LAN segment communicate with stations on a different RS-485 LAN segment. In general, the Primary setting is designed for client applications where stations on the RS-485 LAN segment communicate with server nodes on the distribution LAN. 4. Does the RS-485 LAN segment contains stations that do not periodically generate traffic, or do not include the OWL_ATTACH protocol as part of their RS-485 driver? Answer
Settings
Yes
Inbound/Unicast/Primary Inbound/Unicast/Enabled
Comments: You may need to enable unicast flooding if RS-485 stations do not periodically generate traffic. Occasional traffic is needed to maintain information in the forwarding database. You can also use the Outbound to Secondaries/Unicast/Enabled setting to force unicast flooding to RS-485 stations.
ARP Server Mode ARP Server Mode can convert multicast ARP requests to unicast ARP requests for RS-485 stations in the forwarding database. ARP Server Mode can significantly improve RS-485 network performance in busy IP networks.
4-28
6710 Mobile Bridge User’s Guide
Page 83
SECTION 4
"
Configuration
Settings are: Disabled No Flooding Delay Flooding Normal Flooding
When ARP Server Mode is enabled, the IP addresses of the RS-485 stations are included in the forwarding database. The ARP server learns the IP addresses of RS-485 stations by monitoring IP traffic to those stations. Additionally, some stations may have the capability of explicitly registering IP addresses with the ARP server. This is done with the OWL_ATTACH protocol included in certain RS-485 drivers supplied by Intermec. Setting
Description
Disabled
No special action is taken when an ARP is received. Multicast ARP requests are subject to the frame filters and the setting for MultiFloodLevel. Disabled is the preferred option when a system has no IP RS-485 traffic or has stations that do not register IP addresses. The ARP server converts ARPs from multicast destination addresses to the unicast address of the destination station. No Flooding is the most efficient configuration, since multicast ARPs are never forwarded. Use of this setting requires stations to register IP addresses with the 6710 Mobile Bridge.
No Flooding (default)
6710 Mobile Bridge User’s Guide
4-29
Page 84
SECTION 4
"
Configuration
Setting
Description
No Flooding (Continued)
No Flooding is the preferred option when RS-485 stations should respond to ARPs, and are capable of registering their IP addresses with the 6710 Mobile Bridge. This registration can be accomplished either through regular periodic traffic from the RS-485 station or use of the OWL_ATTACH protocol included in some RS-485 drivers supplied by Intermec. The ARP server converts ARPs from multicast to the unicast address of the destination station. If the destination address is unknown, the initial ARP request is not forwarded. If the requesting device retries the ARP request, second and subsequent ARP requests are forwarded. Delay Flooding is the preferred option when RS-485 stations should respond to ARPs, but are not capable of registering their IP addresses with the 6710 Mobile Bridge. The ARP server converts ARPs from multicast destination addresses to the unicast address of the destination station. If the destination address is unknown, the ARP request is flooded according to the multicast flood level settings.
Delay Flooding
Normal Flooding
Normal Flooding is useful when RS-485 stations need to respond to ARP requests, but are not capable of registering IP addresses with the 6710 Mobile Bridge. Normal Flooding sends more unnecessary ARPs over RS-485 links then delay flooding. Normal Flooding does not introduce occasional delays in ARP responses as Delay Flooding does.
4-30
6710 Mobile Bridge User’s Guide
Page 85
SECTION 4
"
Configuration
[Ports] Use [Ports] to define options for the 6710 Mobile Bridge’s Ethernet port and each RS-485 port. Name MAC Address Status Hello Period 1 “omde” (Unique address) <Enabled> <2 Seconds> 2 “omd485a” (Ethernet port’s <Enabled> <2 Seconds> MAC address) 3 “omd485b” (Ethernet port’s <Enabled> <2 Seconds> MAC address)
" NOTE:
If no RS-485 PC card is installed internally in slot A or B, the Name is “” and Status is Disabled.
The following chart defines options in the Name column. Option omde omd485a or omd485b
Description Ethernet port RS-485 port
Select a port to display its options: Name MAC Address Status Hello Period [Ethernet] [B_B485]
(Depends on the port.) 00:00:00:00:00:00 <Enabled> <2 Seconds>
Name, MAC Address, Status, and Hello Period appear for all ports. The remaining options appear as follows: [Ethernet] [B_B485]
Appears if you selected “omde.” Options start on page 4-33. Appears if you selected “omd485a” or “omd485b.” Options start on page 4-45.
6710 Mobile Bridge User’s Guide
4-31
Page 86
SECTION 4
"
Configuration
Name The read-only Name setting displays the driver name for the type of device occupying this communication port. For example, “omde” is the driver name for the Ethernet port. The name is for internal system use.
MAC Address MAC Address is a read-only option that displays the network address of the Ethernet port or RS-485 port. The 6710 Mobile Bridge automatically identifies the addresses of devices installed in or attached to its communication ports. The MAC address for each RS-485 port is the MAC address of the Ethernet port.
Status The Status option sets the condition of the Ethernet port or RS-485 port. Settings are: Enabled Disabled
Setting
Description
Enabled (default) Port is available for use. Disabled
Port is not available for use.
Hello Period The hello period determines how frequently the 6710 Mobile Bridge broadcasts hello messages on the network. On Ethernet links, hello messages are used to maintain the spanning tree. Settings for Hello Period are:
4-32
6710 Mobile Bridge User’s Guide
Page 87
SECTION 4
"
Configuration
1 Second 2 Seconds 3 Seconds
You should never need to change the default of 2.
Ethernet Options Use [Ethernet] to set Ethernet port options: OWL Frame Type Cable Type [Static Addresses] [Normal RX Filter] [Advanced RX Filter]
<DIX> <Auto Detect>
OWL Frame Type OWL Frame Type is the Ethernet type for communication among 6710 Mobile Bridges. Settings are: DIX SNAP
Setting
Description
DIX (default)
Adds DIX (Ethernet 2.0) header to open wireless LAN frames. DIX is the default because it is the most commonly used Ethernet frame type.
SNAP
Adds an 802.3 SNAP header to open wireless LAN frames. In some cases, open wireless LAN frames must be encapsulated in SNAP frames.
6710 Mobile Bridge User’s Guide
4-33
Page 88
SECTION 4
"
Configuration
Cable Type Cable Type specifies the type of Ethernet medium to which the 6710 Mobile Bridge is connected. It is recommended that you explicitly set the cable type. Settings are: 10BaseT 10Base2 AUI Auto Detect
Setting
Description
10BaseT
Selects the RJ11 connector (sets type to 10BASE-T, twisted pair). The cable type defaults to 10BASE-T if no traffic is heard on any Ethernet port (10BASE2, 10BASE5, or 10BASE-T) during a 10-second time window when the 6710 Mobile Bridge starts up. Selects the BNC connector (sets type to 10BASE2, thinnet).
10Base2 AUI
Selects the AUI 15-pin D-sub connector (sets type to 10BASE5 thicknet, and other types).
Auto Detect (default)
Automatically selects cable type by listening for traffic on Ethernet ports during initialization. For this to work, the 6710 Mobile Bridge must be connected to the Ethernet medium during system start-up, and other devices on the Ethernet medium must be transmitting at least one frame every 10 seconds.
[Static Addresses] Use [Static Addresses] to define a list of 20 or fewer permanent unicast 802 MAC addresses connected to this Ethernet port. The Static Address Table displays the addresses:
4-34
6710 Mobile Bridge User’s Guide
Page 89
SECTION 4
"
Configuration
1 00.00.00.00.00.00 2 00.00.00.00.00.00 3 00.00.00.00.00.00 . . . 20 00.00.00.00.00.00
Select an address, then type 6 hexadecimal pairs for the new address at the prompt: Range is: 6 hex pairs
Static addresses become permanent entries in the route table. This is useful when configuring designated 6710 Mobile Bridges for secondary (RS-485) LANs, since it reduces the need to flood frames to wired stations on the secondary (RS-485) LAN segment.
[Normal RX Filter] Ethernet filters allow elimination of frame types that do not need to be forwarded to RS-485 stations. The main benefit of filtering is reduction in unnecessary RS-485 transmissions. Options are: [Frame Types] [SubTypes 1] [SubTypes 2]
6710 Mobile Bridge User’s Guide
4-35
Page 90
SECTION 4
"
Configuration
[Frame Types] allows filters to be established for common networking protocols such as IP, Novell IPX, and 802.2 LLC (Logical Link Control). Separate selections are available for each of the three Ethernet standards: DIX (Ethernet 2.0), 802.3, and 802.3 SNAP. A filter may be configured to pass or drop all frames of a given type. Alternatively, filters may be set to operate on selected subtypes within each frame type category. [SubTypes 1] lists several predefined frame types as well as user-defined frame types. Settings under [SubTypes 2] allow additional user-defined frame subtypes to be specified. The default 6710 Mobile Bridge configuration passes all frame types.
[Frame Types] [Frame Types] options are:
DIX-IP-TCP Ports DIX-IP-UDP Ports DIX-IP-Other Protocols DIX-IPX Sockets DIX-Other EtherTypes SNAP-IP-TCP Ports SNAP-IP-UDP Ports SNAP-IP-Other Protocols SNAP-IPX Sockets SNAP-Other EtherTypes 802.3-IPX Sockets 802.2-IPX Sockets 802.2-Other SAPs
4-36
6710 Mobile Bridge User’s Guide
Action <Pass> <Pass> <Pass> <Pass> <Pass> <Pass> <Pass> <Pass> <Pass> <Pass> <Pass> <Pass> <Pass>
Scope <Unlisted> <Unlisted> <Unlisted> <Unlisted> <Unlisted> <Unlisted> <Unlisted> <Unlisted> <Unlisted> <Unlisted> <Unlisted> <Unlisted> <Unlisted>