Page 101

SECTION 4

" NOTE:

Configuration

"

The 6710 Mobile Bridge includes an autodetect feature that senses the Ethernet medium if traffic is present. If no traffic is present on the cable, the system software defaults to 10BASE-T. For most installations, it is recommended that you explicitly set the Ethernet type.

The 6710 Mobile Bridge must go through its boot sequence before you can configure it through the browser. If you reboot it while you are configuring it through the browser, the session terminates. You can create a new session after the 6710 Mobile Bridge reboots. To establish a browser session, see Figure 4-3 and the procedure following it. Ethernet LAN

HTTP

1 2

1. Platform with Web browser 2. 6710 Mobile Bridge

Figure 4-3 Web Browser Session

1. Ensure the 6710 Mobile Bridge is connected to the Ethernet cable and has an assigned IP address. 2. Ensure the Web browser is installed on the platform. 3. Start the browser application. 4. Enter the 6710 Mobile Bridge’s IP address in the browser’s Uniform Resource Locator (URL) field. For example: http://999.999.99.99

6710 Mobile Bridge User’s Guide

4-47

Page 102

SECTION 4

"

Configuration

After you enter the correct IP address, the Enter Network Password screen appears: Enter Network Password

OK

Please enter your authentication information. Resource:

(resource number)

User name:

(resource number)

Password:

*******

Cancel

Save this password in your password list.

5. Enter the user name and password. Refer to the following chart for help with all fields. Setting

Description

Resource

A number assigned to this session. The number changes every time you access the Enter Network Password screen. The Resource number. For example, if the Resource number is 3550, the user name is 3550. Configuration menus’ top-level password. The default password is CR52401 (case insensitive). For security, the password appears as asterisks on the screen.

User name Password

Save this password in your password list

4-48

6710 Mobile Bridge User’s Guide

If you check this option, the browser saves the password. You do not need to select this option because the Resource number changes every time you access this screen.

Page 103

SECTION 4

" NOTE:

"

Configuration

Only one computer at a time can access the configuration menus. If you unexpectedly receive a request for the user name and password, another user may be trying to view or modify the configuration through Telnet or the DIAG port. If a different computer tries to start another Web browser session, it is refused until the current session logs out.

Following is the initial screen that appears after you enter the correct user name and password. Configure the 6710 Mobile Bridge by following the directions provided on this screen and the help screens. In addition, this user guide’s Index lists the page numbers for all menu options.

6710 Mobile Bridge User’s Guide

4-49

Page 104

SECTION 4

"

Configuration

6710 Mobile Bridge Configuration Configuration Menus Review/write Changes F Logout

F

F

F

Reboot

Security Once you’ve successfully entered the user name and password into your browser, you are authorized to access the configuration. If five (5) minutes elapses without configuration activity, you will become unauthorized again. Only one computer at a time is allowed to be authorized for access to the configuration menus. If you unexpectedly receive a request for user name and password, it’s possible that another user is currently attempting to view or modify the configuration via telnet or the serial port. An attempt to start another HTTP session from another computer will be refused until this session has been logged out.

How to use the Configuration Menu 1. Select Review/write changes to see the existing changes from the defaults. Optionally select an Undo option to remove changes. 2. Locate and change configuration items by navigating in the Configuration Menu. 3. Select the Submit Changes button to submit the changes on each form. 4. Repeat the above steps until all changes have been submitted. 5. Select Review/write changes and review the changes you have made. 6. Select Commit to write the changes. Note: Some early browser versions can’t be convinced by the server to always get a fresh copy of a document that was previously fetched. This might cause old and misleading information to be displayed. Updating the browser, pressing the reload button, or disabling the browser’s cache may be helpful. Copyright e1996-1998 Intermec Technologies Corporation. All rights reserved.

4-50

6710 Mobile Bridge User’s Guide

Page 105

SECTION 4

"

Configuration

Configuration Guidelines Planning Your Installation To plan your installation, refer to “Finding the Best Location” in Section 3 for installation guidelines.

Using the Configuration Guide The configuration guide in Table 4-1 summarizes the necessary steps to set up an RS-485--Ethernet LAN. Table 4-1 provides basic setup information for a simple network using 6710 Mobile Bridges on a single Ethernet segment. This type of network may contain bridges or hubs.

6710 Mobile Bridge User’s Guide

4-51

Page 106

SECTION 4

"

Configuration

Table 4-1 Configuration Guide z = required step; Z = recommended step

1. Configuration Planning z

If more than one 6710 Mobile Bridge will be installed on this Ethernet LAN segment, select which 6710 Mobile Bridges will be primary and fallback super root candidates (page 4-22).

2. Preliminary Configuration Before Installation Configure 6710 Mobile Bridges with IP address configuration (page 4-14) or the DHCP server name (page 4-18). Z Configure the Ethernet port cable type (page 4-34). Z For the OWL frame type, use DIX (the default) (page 4-33). z If more than one 6710 Mobile Bridge will be installed on this Ethernet LAN segment, configure the root priority in super root candidates to specify primary and fallback 6710 Mobile Bridges. Set all other 6710 Mobile Bridges to root priority 0. (Page 4-22.) z

"

NOTE:

Set the highest root priority in the primary super root, and lower root priorities in no more than two fallback super roots.

3. Additional Configuration z

Set Global Flooding parameters in super root candidates (page 4-24).

z

Configure the baud rate for each RS-485 port (page 4-45).

Enable the Proxy ARP Server if RS-485 IP stations are being supported (page 4-28). (The default is No Flooding.) Z Set Ethernet filters to optimize frames forwarded to RS-485 stations (page 4-35).

Z

4-52

6710 Mobile Bridge User’s Guide

Page 107

Section 5

Software Download "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

This section describes the file system structure, File Menu commands, and the ROM command monitor for the 6710 Mobile Bridge.

File System Structure The 6710 Mobile Bridge’s file system has four separate segments (analogous to a directory in most computer file systems).

Boot Segments 1 and 2 The first two segments (1 and 2) are .75 MB boot segments. Either boot segment can hold the bootable (executable) FLASH file MSD29.BIN, which loads when you reboot the 6710 Mobile Bridge. You can store different versions of MSD29.BIN in the boot segments and then configure the 6710 Mobile Bridge to use one of them.

Data Segments 3 and 4 The next two segments (3 and 4) are .25 MB data segments. Either data segment can hold the self-extracting HTML configuration files.

6710 Mobile Bridge User’s Guide

5-1

Page 108

SECTION 5

"

Software Download

Active and Inactive Segments The 6710 Mobile Bridge has an active boot and data segment, as well as an inactive boot and data segment: The inactive segment is where you can download a new file. " The active segment contains the files that are loaded at boot time. An active boot segment pointer and an active data segment pointer point to the appropriate “active” segments. The segment not pointed to by one of these “active” pointers is the inactive boot or data segment. After you load an inactive segment with a new file, you can change the “active” pointers to the segment that holds the new file. You then reboot the 6710 Mobile Bridge so the changes take effect. At this point the following occur: "

The 6710 Mobile Bridge is running the new version of software. " The segment holding the new files is now the “active” segment. " The old version of software is in an inactive segment.

"

" NOTE:

If the active segment is empty when you reboot the 6710 Mobile Bridge, you must establish a new session through the DIAG port to reload the unit with software.

RAM Segment The file system supports a fifth segment known as the RAM segment. The RAM segment is similar to the other segments, except the file contents are stored in RAM and the segment’s contents are lost when you reboot the 6710 Mobile Bridge.

5-2

6710 Mobile Bridge User’s Guide

Page 109

SECTION 5

"

Software Download

The RAM segment is limited to a maximum of 4096 bytes. It is used to hold small script files during the software download process. When you view the file directory, the program currently executing displays as if it were in the RAM segment. This program, however, is not really a part of the RAM segment. You cannot delete or erase it, and TFTP commands cannot read or write to it. It displays as part of the file directory so you can determine which version of software is running.

Segment Names You must enter a segment for most 6710 Mobile Bridge file system commands. You can type the numeric digits (1, 2, 3, or 4) corresponding to the respective file segments, or you can use the following mnemonics (the 6710 Mobile Bridge translates them to a segment number): Mnemonic

Description

AB

Active boot segment.

IB

Inactive boot segment.

AD

Active data segment.

ID

Inactive data segment.

RAM

RAM segment.

6710 Mobile Bridge User’s Guide

5-3

Page 110

SECTION 5

"

Software Download

File Names Several file system commands require you to enter file names. You can precede file names by a segment number or name followed by a colon. EXAMPLE 1:

AB:MSD29.BIN refers to the file MSD29.BIN in the active boot segment (segment 1 or 2).

EXAMPLE 2:

1:MSD29.BIN refers to the file MSD29.BIN in segment 1.

If you omit the segment number or segment name, the 6710 Mobile Bridge searches the segments in this order until it finds a file matching the file name: RAM, 1, 2, 3, 4

Downloading Programs You can download new programs to the 6710 Mobile Bridge while it is operating. The unit has two program FLASH directories so that if an issue exists with the download of the new FLASH, the system can reboot to the previous version. An internal timer allows the activation of the new software program to be immediate or activated later.

File Menu Commands Commands for software download and other processes are located on the File Menu. To display the commands, type the following at the Main Menu prompt: >file

5-4

6710 Mobile Bridge User’s Guide