Page 34
2-10
Chapter 2: Features, Functions, and Kits
Side Scanner Window The NCR 7870 vertical scan window is mounted in a tower that rises above the checkstand surface. The scan window can be removed from the unit for cleaning. The upper console containing the scan window is designed to withstand occasional impacts. Side (Vertical) Scan Window
Slot (Horizontal) Scan Window
16821
Page 35
Chapter 2: Features, Functions, and Kits
2-11
Scale Features and Functions The scale is used in the 2000, 4000, and 4500 models. It can be manufactured by NCR or by a vendor for a specialized market such as the price-computing scale in the 4500 model to meet European standards.
Scale Functions and Features Load Cell The NCR 7870 uses a single load cell rather than four, which is more typical, to increase reliability. The scale has a settling time of 0.9 seconds for items weighing less than 2.3 kg (5 lbs.) It is sealed to avoid damage from spills around the unit. There are three basic types of load cells: •
For weighing in pounds. Capacity: 30 lbs.
•
For weighing in kilograms. Capacity: 9.995 kg
•
For weighing in kilograms. Capacity: 13.995 kg
Reset / Scale Zero A front-mounted Scale Reset button is located on the front bezel, to the left of the vertical scan window. This flush membrane switch will reset the scale due to fluctuation from extreme temperature drift, impact, or scale tare up to: 1. 0.3 kg (0.6 lbs.) relative to the zero established during the most recent power-on sequence or 2. 0.6 kg (1.2 lbs.) relative to the calibration zero, whichever is less. The scale reset function is completed in less than a second. Auto-Zero Scale electronics automatically tracks out stable shifts due to temperature changes and compensates in 3 g (0.006 lb.) increments up to a maximum of 0.3 kg (0.6 lbs.).
Page 36
2-12
Chapter 2: Features, Functions, and Kits
Kits Kit Name
Kit Type
Available for
Enhanced Scratch Resistant Window 7870-K002-V001
Hardware
7870-1000 7870-2000
Upper Windows (Qty: 5) 7870-K003-V001
Hardware
All
Stainless Steel Top Plate 7870-K005-V002
Hardware
7870-1000 7870-2000
Scale Shell Model 7870-K007-V001
Hardware
N/A
Digital Board Upgrade (Board, Hardware, Firmware) Firmware 7870-K100-V001
All
Requirements: For units with S/Ns below 50-28901727, adds Speech and Coupon Add-On Code. PACESETTER Plus Upgrade (OCIA/IBM) 7870-K401-V001, -V002 Requirements: V001 supports units with S/Ns 50-28901727 or lower. V002 supports units with S/Ns 50-00000000 and higher.
Firmware
All
Page 37
Chapter 2: Features, Functions, and Kits
2-13
Kit Name
Kit Type
Available for
PACESETTER Plus Upgrade (RS-232/Datachecker) 7870-K402-V003, –V002, -V003
Firmware
All
Requirements: V001 supports units with S/Ns 50-28901727 or lower. V002 supports units with S/Ns 50-00000000 and higher. V003 has a PACESETTER Plus trailer fix. Multi-Symbol Upgrade 7870-K404-V002
Firmware
All
Requirements: For units with S/Ns 50-28901727 and higher. If upgrading a unit with a lower S/N, install kit 7870-K100. 13.995 kg Upgrade 7870-K440-V001
Firmware, Hardware
7870-2000
Requirements: For upgrade from 9.995 kg to 13.995 kg on units with S/Ns 50-28901727 and higher. To upgrade a unit with a lower S/N, install kit 7870-K100. OCIA/IBM Interface – Single Cable 7870-K450-V001, -V002
Hardware, Firmware
All
Requirements: V001 supports units with S/Ns 50-28901727 or lower. V002 supports units with S/Ns 50-00000000 and higher. OCIA/Interface – Dual Cable 7870-K451-V001, -V002
Hardware, Firmware
7870-2000
Requirements: V001 supports units with S/Ns 50-28901727 or lower. V002 supports units with S/Ns 50-00000000 and higher.
Page 38
2-14
Chapter 2: Features, Functions, and Kits
Kit Name
Kit Type
Available for
RS-232 Interface (Board, Firmware) 7870-K452-V003
Hardware, Firmware
All
Requirements: V001 supports units with S/Ns 50-28901727 or lower. V002 supports units with S/Ns 50-00000000 and higher. V003 enhances the old digital board firmware. Datachecker, 2170, ICL MDL, ICL 9518/9535, SASI Interface 7870-K455-V001, -V002, -V003
Hardware, Firmware
All
Requirements: Kit is for interfacing with these host terminals: NCR 2170 (RS-232, Weightronix Emulation), Avery Emulation (RS-232), Datachecker (RS-422), ICL MDL, ICL 9518, ICL 9535 (ICL Team POS 5000), SASI. V001 supports only ICL T2001, V002 supports units with S/Ns 5028901727 or lower. V003 supports units with S/Ns 50-00000000 and higher. Non NCR OCIA 7870-K457-V002
Hardware, Firmware
All
Requirements: V001 supports units with S/Ns 50-28901727 or lower. V002 supports units with S/Ns 50-00000000 and higher. Casio and TEC Scale Interface 7870-K458-V003
Hardware, Firmware
7870-2000
Requirements: V001 supports units with S/Ns 50-28901727 or lower. V002 supports units with S/Ns 50-00000000 and higher. V003 supports the same as V002 plus TEC.
Page 39
Chapter 2: Features, Functions, and Kits
2-15
Kit Name
Kit Type
Available for
IBM 4682/4693/4694 Standard Interface and IBM 4682-4B Full ASCII Interface 7870-K459-V002
Hardware, Firmware
All
Requirements: V001 supports units with S/Ns 50-28901727 or lower. V002 supports units with S/Ns 50-00000000 and higher. Datachecker 2000 Interface 7870-K463-V001
Hardware
All
Requirements: 7870 must be configured for Single-Cable, OCIA. Dual Cable RS-232 Interface for I/F 1 7870-K465-V001
Hardware, Firmware
7870-2000
Requirements: 7870 must be configured for OCIA or IBM communications. Avery Emulation (RS-232), Weightronix Emulation (RS-232) for scanners with an I/F 1 Interface Board. Australia with I/F 1 Interface to 2126 Dual Cable 13.995 kg (Coles) 7870-K466-V001
Hardware, Firmware
7870-2000, kg units only
Requirements: For upgrading units with a) S/Ns 50-28901727 and higher and b) I/F 1 Interface Board from 9.995 kg to 13.995 kg. To upgrade units with lower S/Ns, kit 7870-K100 must also be installed. If the unit has an I/F 2 Interface Board, kit 7870-K450 must also be installed. Integrated Display 7870-K480-V001
Hardware
All
Page 40
2-16
Chapter 2: Features, Functions, and Kits
Kit Name
Kit Type
Available for
Top Plate with Scratch-Proof Window (Standard size) 7870-K601-V001
Hardware
7870-1000 7870-2000
Top Plate with Scratch-Proof Window (Compact) 7870-K605-V001
Hardware
7870-3000
WalMart/Argentina Upgrade 7870-K846-V001
Hardware, Firmware
7870-2000
Requirements: To upgrade a 9.995 kg scanner/scale to Argentina requirements, unit must have a) S/N 50-28901727 or higher and b) an NCR 7825 Remote Display. Coupon Add-On Code Upgrade 7870-K850-V001
Firmware
All
Requirements: For units with S/Ns between 50-28901727 and 5031148616. For units with S/Ns 50-2891727, use kit 7870-K100. For units with S/Ns 50-31148616 and larger, no kit is needed – enable feature through programming options. Checkpoint Scanner Bezel 7870-K896-V001
Hardware
7870-1000 7870-3000
Requirements: A Checkpoint representative must make the final connection from the 7870 to the Checkpoint equipment after kit installation.
Page 41
Chapter 2: Features, Functions, and Kits
Kit Name
Kit Type
Checkpoint Scanner/Scale Bezel 7870-K898-V002, -V003
Hardware
2-17
Available for
Requirements: Kit is mandatory for upgrading to Checkpoint on units with S/N 50-32573274 or lower. For units with higher S/Ns, may use this kit or kit 7870-K899-V001. V002 is for use in U.S. and Mexico only. A Checkpoint representative must make the final connection from the 7870 to the Checkpoint equipment after kit installation. Checkpoint Scanner/Scale Bezel 7870-K899-V001
Hardware
Requirements: For units with a S/N 50-32573274 and higher. For units with a lower S/N, install kit 7870-KK898-V003. A Checkpoint representative must make the final connection from the 7870 to the Checkpoint equipment after kit installation.
Page 42
2-18
Chapter 2: Features, Functions, and Kits