Page 25

Chapter 2: Features, Functions, and Kits

This chapter describes the features, functions, and kits. Specification and performance data on the 7870 unit and its major components is also provided.

General Features and Functions Bar Code Recognition The 7870 can recognize and read a number of bar codes including: • UPC-A

• Code 39 (Code 3 of 9)

• UPC-E

• Code 128

• UPC-D (limited set)

• Interleaved 2 of 5

• EAN-8/13

• Add-On Codes

• JAN-8/13 It is possible that in some situations, the 7870 may be able to read more types of bar codes than the host terminal’s application program. In such a case, either the application program must be upgraded to read these bar codes or the 7870 must be told, using the Programming Tags (BST0-2121-74), to ignore the particular bar code type.

Page 26

2-2

Chapter 2: Features, Functions, and Kits

Bi-Optic Scanning The NCR 7870 combines horizontal and vertical scan patterns. Having two active scan windows allows the checker to bring a product into the scan zone without having to orient it to a single scan window. Portions of the bar code are read by each scanner, assembled into a complete code by the digital board and sent to the host terminal.

Decode Features Standard Decode and PACESETTER Plus are available for bar code label decoding. Standard Decode is the standard feature and PACESETTER Plus is the upgrade. Please note that the PACESETTER Plus upgrade includes the Standard Decode.

PACESETTER Plus Bar code labels in a retail environment are occasionally unreadable. Labels can be overprinted, underprinted, or truncated. Others may have missing margins or be placed around corners. PACESETTER Plus determines what is wrong with a label, compensates and fixes the data, and transfers the information to the host terminal. Voice messages can be used to describe what is wrong with a label. There are three modes of operation in PACESETTER Plus. •

Mode 1 – Inquiry Mode

•

Mode 2 – Real-Time Mode

•

Mode 3 – Operations Mode

Mode 1 – Inquiry Mode Inquiry mode keeps a tally count of label readability. Labels are judged as: Good reads Good reads with overprinted bars Good reads with underprinted bars

No reads (incomplete labels) Missing margins

Page 27

Chapter 2: Features, Functions, and Kits

2-3

In Mode 1 the tally counts are displayed on the integrated display or the NCR 7825 remote display. The percentage of each error type to the good reads tally is also displayed. All the tally counts can be reset to zero. Mode 2 – Real-Time Mode In Mode 2 the scanner is off-line and the scale is disabled. The scanner reads bar codes and indicates label readability, whether labels are missing bars, overprinted, underprinted, missing margins, or are “no read.” Mode 3 – Operations Mode Mode 3 is the normal operating mode. While in this mode, the scanner can be programmed to add trailer information about label readability to the UPC/EAN data. The host terminal must be capable of receiving the trailer and configured appropriately.

Displays A display separate from the host terminal is useful and sometimes required for use with NCR 7870 Scanner/Scales -- the 2000, 4000, and 4500. These models are available with a remote post-mounted display, an integrated display, or no display.

NCR 7825 Remote Display The post-mounted NCR 7825 is the standard display and is available as a user-installable kit to upgrade older units in the field. Early versions of the NCR 7825 Remote Display are mounted on a post that attaches to the checkstand. The current NCR 7825 is a compact design available with a single or dual display, one for the customer and one for the checker. The following illustration shows the current model with dual displays and the earlier model.

Page 28

2-4

Chapter 2: Features, Functions, and Kits

NCR 7825 Remote Compact Display

NCR 7825 Remote Post Display

16345

Depending on the checkstand construction, a keyboard may be mounted above the 7870, which will obstruct the view of the integrated display. In this case, it may be advantageous to install an NCR 7825 Post Mounted Display, which can be used with or without an integrated display.

Integrated Display The integrated display is an inset, LCD located on the top surface of the tower. Depending on the checkstand design, the integrated design may or may not be appropriate.

Integrated Display

Tower

16819

Page 29

Chapter 2: Features, Functions, and Kits

2-5

No Display If the 7870 is ordered with no display, the scale information is usually displayed on the host terminal display. Please note, the host terminal must be approved to perform a live/gross scale weight. This arrangement is not available in all host terminals and some Weight and Measures authorities do not permit this arrangement.

Interface Types The NCR 7870 communicates with the host terminal through various types of interfaces. The 7870 Scanner always uses one interface cable. However, some host terminals require dual cables for and NCR 7870 Scanner/Scale. See the Interface Cables section in Chapter 3: Site Preparation for available interface cables.

Laser Scanner The 7870 operates with the performance of two scanners yet the bioptic scan pattern is created by a single laser and spinner motor. A 24 line convergent scan pattern (12 lines per scan window) is generated by the laser diode. A 3-Phase, DC, brushless motor spins a tetrahedral mirror at 6000 RPMs. The laser beam is reflected onto the stationary mirrors in the Optics Assembly and then out the Scan Windows. The Spinner Motor provides a scan speed of 2400 scan lines (100 scan frames) per second. This enables the 7870 to read at a continuous item speed of 2.0 meters per second. An experienced checker scans at a rate of 0.8 to 1.0 meters per second, so the 7870 is able to keep up with high volumes and fast checkers.

Power Supply A universal, switching Power Supply is used to provide DC voltage. It has a replaceable, 3 m (10 foot) cord for connection to the power outlet or source. A low voltage power cable connects the Power Supply to the unit. The Power Supply can be fixed to the unit’s chassis on or located on the floor or checkstand in the NCR 7870-1000 and 2000. For other models, the Power Supply must be installed in the checkstand.

Page 30

2-6

Chapter 2: Features, Functions, and Kits

An outboard power supply permits the 7870 to operate without checkstand ventilation. The Power Supply accepts input line voltages from 90 to 260 VAC at a frequency range of 47 to 63 Hz. For a list of Power Cables and Cords, see the Cables Lengths and Hole Sizes section in Chapter 3: Site Preparation. Power Cable (To AC)

Outboard Power Supply

Power Cord (To Unit) 16822

Programming the 7870 The NCR 7870 is featurized to fit a customer’s needs by using programming tags which alter the unit’s operating parameters. Following are some of the more common parameters which may be adjusted: • Communications Protocol

• Code 39

• Good Read Tone

• Code 128

• Not-On-File Tone Volume

• RS-232

• Timers

• Interleaved 2 of 5

• UPC/EAN

• PACESETTER Plus

• Add-On Code

• Label Identifiers

Page 31

Chapter 2: Features, Functions, and Kits

Scale Certifications Scale certifications are available for these markets:

Market

9.95 kg

Argentina

•

Australia

•

Brazil

•

13.995 kg

30 lb.

• •

California Canada

•

Czech Republic

•

Europe

•

Hong Kong

•

Indonesia

•

International

•

Mexico

•

New Zealand

•

People’s Republic of China

•

Russia Federation

•

•

•

•

•

United Kingdom

•

U.S.

•

Venezuela

•

Vietnam

•

2-7

Page 32

2-8

Chapter 2: Features, Functions, and Kits

Scan Zone The scan lines are dispersed in a forward and backward direction from both windows. This allows the scanner to read a) on four sides, b) from left-to-right or right-to-left, and c) inverted labels. If the scan zone is thought of as a cube resting on the horizontal scan window, the scanner is able to read the leading, trailing, bottom, and far surfaces. Another way of describing the scan zone is – if the checker can’t see the bar code label, then the scanner can. The scan zone extends to 20.3 cm (8 in.) high off the horizontal window. Bi-optical scanning makes the scan zone large enough to allow a label to be read off of a tall soup can even when upside-down

Scanner Power Requirements The laser diode occupies little space, draws low current, and produces little heat. The light produced by the scanners in current models has been shifted toward the edge of the visual spectrum so it is not possible to see the scan pattern in normal lighting. When active, the laser uses 22 watts. A soft power down feature allows major portions of the 7870 to shut down when no motion is detected. While in sleep mode, the scanner’s power requirements drop to 10 watts, a 65% reduction. A more valuable advantage of the soft power down feature is the run time reduction of critical components which translates directly into extending the life of the scanner. The scanner automatically powers up after detecting motion in approximately two seconds.

Soft Power Down During periods of inactivity, components of the scanner and scale shut down to conserve power, reduce wear, and extend product life. A motion sensor detects activity and signals the unit to power up from sleep mode. The power up takes less than two seconds.

Page 33

Chapter 2: Features, Functions, and Kits

2-9

Top Plates and Scan Windows Top Plates A Top Plate provides a snag-free place to scan items and protects the internal components from contamination and liquid spills. It has an inset Lift Tab (older units may have two) which permit the Top Plate to be quickly removed or replaced with no tools. The scan window inset in the Top Plate is either diamond-coated (replaceable) or sapphire glass (permanent). When a unit has a scale, the Top Plate becomes a part of the scale system – the scale must be recalibrated when the Top Plate or any of its components, such as the scan window, are replaced. The current line of 7870 Scanners and Scanner/Scales have been upgraded to come with the Stainless Steel Top Plate as a standard feature. Older 7870 units may have the painted steel Top Plate which is no longer available. Slot (Horizontal) Scan Window Top Plate Lift Tab

Slot Scanner Window The (horizontal) scan window is mounted in the Top Plate. The window (if diamond-coated) is replaced by removing the Top Plate, snapping out the old window, and snapping the new window in place. The slot scanner window is available as diamond-coated glass or sapphire glass. Diamond-coated glass was formerly known as “scratch-resistant” glass. Sapphire glass is the upgrade and was formerly known as “scratch-proof” glass. Other glass options such as “hardened” and “armor” glass have been discontinued.