NCR 7870 Scanner/Scale Release 1.0 User's Guide: Chapter 6: Operation

Pages 105 to 116 of 228, from NCR 7870 Scanner/Scale Release 1.0 User's Guide

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the NCR 7870

Page 105

Chapter 6: Operation

This chapter describes how to operate the NCR 7870. Following is a diagram of the NCR 7870.

Integrated Scale Display

Operator Display Panel

Vertical Scan Window

Horizontal Scan Window

Scanner Operator Display Panel

Scanner/Scale Operator Display Panel

Top Plate

Red Status Indicator

Red Status Indicator

Green Status Indicator

Green Status Indicator RESET

Reset/Zero Indicator Reset/Scale Zero Button

Motion Detector

Reset Indicator SCALE ZERO

Reset Button

Motion Detector R0125

Page 106

6-2

Chapter 6: Operation

About Using the Operator Controls Scan Windows The NCR 7870 contains a vertical and horizontal scan window. The vertical scan window is mounted in a Tower Cabinet that rises above the checkstand surface. The horizontal scan window is flush-mounted in the Top Plate.

Status Indicators Status Indicator

Function

Occurs

Red (Steady)

Indicates unit is in standby mode to read next label.

Between scanning.

Green

Flashes once to indicate a successful bar code read.

After scanning.

Yellow

Indicates scale has been reset/zeroed.

When Scale Zero button is pressed.

Signals a scale error code may be on display.

Primarily during Power Up.

Red (Slow Flash)

Indicates unit is off-line. Host When IBM 468x terminal may be off or communication is interface cable is not used. connected.

Red-Green Flashing

Indicates Failure Mode. A scanner error code will be repeated.

During Power Up.

Red-RedRed

Three red flashes indicate an item is not on record in price lookup file.

After scanning an item.

Red-Green Alternate

Sleep Mode

During operator inactivity.

Page 107

Chapter 6: Operation

6-3

Motion Detector The Motion Detector is used to detect operator inactivity and power down critical components of the NCR 7870 to reduce wear and extend product operational life

Reset / Scale Zero Button This button is used to • re-zero the scale if not performed automatically,

• set a tare weight, and

• awaken the unit from Sleep Mode.

Audible Tone A tone can be programmed to sound to indicate a successful bar code read. This may be easier for the checker than watching the Status Indicators. The tone’s frequency, volume, and duration can also be set via programming. The NCR 7870 comes from the factory with the tone enabled. See Chapter 7: Programming for more information on the Good Read programming parameter.

Voice Messages If equipped, this feature provides a voice message when • the scanner/scale goes on-line or off-line,

• the communication protocol is checked,

• item tags are checked using PACESETTER Plus,

• certain error conditions exist,

• there is interference with the scale, and

• when the scanner windows may be dirty.

Page 108

6-4

Chapter 6: Operation

About Using the Scanner Proper Label Orientation Because the NCR 7870 uses bi-optic scanning, labels can be read from many angles. Labels can be read from the leading, trailing, bottom, and opposite sides of a package. Bar code labels can be scanned from left-to-right or right-to-left. A good rule of thumb is – if you can’t see the label, the NCR 7870 can read it.

Bar Code Label

R0126

Page 109

Chapter 6: Operation

6-5

Active Scan Zone The active scan window is shown in the following diagram. The 7870 can read labels presented within the cube.

6.0 in. (15.2 cm)

5.8 in. (14.7 cm)

5.0 (12.7 cm)

Scan Zone

R0127

Multiple Reads Only one good read is reported if a label is placed within the scan zone and left there. Scanner firmware prevents a second read of the same label if it occurs within a preset time of a good read. The preset time is tag-programmable from 250 to 1500 milliseconds in 50 millisecond increments. The factory default is 900 milliseconds. To scan a label a second time, remove the item from the scan zone and then scan it again after the preset time has elapsed.

Page 110

6-6

Chapter 6: Operation

Bar Code Quality Many labels in a typical retail environment are unreadable. The illustration shows some of the common problems. Vendors and printers regularly supply products to the market with bar codes that are overprinted, underprinted, or truncated. Some labels have missing margins. Others may be printed around the corners of packages, or on media not likely to remain flat when picked up.

0

01234 56789

6

0

01234 56789

6

0

01234 56789

6

0

01234 567 89

6 R0026

The readability of a label depends on variables such as size, placement, color, paper type, ink viscosity, and package coatings. The middle of a printing run can yield erroneous labels due to the many variants involved. In particular, poor color contrast and marginal print quality can make a label hard to read. A label should be considered readable if it meets or exceeds the requirements set forth in the UPC Symbol Specification published by the UPC Council, Inc. (March 1982), and the General Specification for Article Symbol Marking, Copyright EAN-1977.

Page 111

Chapter 6: Operation

6-7

Operating Instructions Power Up The 7870 has no ON/OFF switch. The checkstand should be equipped with a circuit breaker switch during site preparation. The switch should be easily accessible and near the operator. Power up the NCR 7870 on by turning the circuit breaker switch to ON. The NCR 7870 performs diagnostic checks during the power up procedure. If a scale error occurs, the yellow Status Indicator will light and an error code will appear on the NCR 7825 Remote Display or Integrated Display. If a scanner error is detected, and error tone will sound and the red and green Status Indicator lights will flash a code. In the event of a problem in the power up process, call a supervisor, service company, or the NCR Customer Service Center for assistance.

Scanner Only Models For the 1000 and 3000 models, if no error occur during power up the unit will enter Startup Mode. The red Status Indicator will flash, the green Status Indicator will flash, and a tone will sound. The red Status Indicator will then light. The unit is ready for use.

Scanner/Scale Models For the 2000, 4000, and 4500 models, if no errors occur during power up the unit will enter Startup Mode. The red Status Indicator will flash and all segments on the display (remote or integrated) will be turned on for five seconds. The green Status Indicator light will flash , a tone will sound, and the display will show SCALE READY 0.000 kg or SCALE READY 0.00 lb. The red Status Indicator will light. The unit is ready for use. The Scanner/Scale models should warm up for five minutes before being put into use.

Page 112

6-8

Chapter 6: Operation

Scanning Procedure To use the NCR 7870, the item must pass through the active scan region. Item orientation, motion, and sequential handling are required for proper label reading.

Instructions 1. Verify scanner is operable. The red Status Indicator must be lit. 2. Locate label on item. 3. Orient item so label faces away from you. 4. Pass item across the lower scan window. 5. If a good read occurs, the green Status Indicator will flash. A tone will sound if the Good Tone parameter has been enabled. The red Status Indicator will light indicating the unit is ready to read another bar code. 6. If a good read does not occur, scan the item again. 7. If a good read still does not occur, manually enter information for the item. Continue to scan.

Not-On-File Error The Not-On-File feature is available on the NCR 7870 only if the host terminal has this capability. If a label is not in the price lookup file, a special tone sounds three times a second and the red Status Indicator flashes repeatedly. The volume of the Not-On-File tone is programmable. The unit becomes disabled from reading additional labels until the error is cleared. To clear, press the host terminal’s CLEAR key and manually enter the information.

Page 113

Chapter 6: Operation

6-9

Weighing Procedure The NCR 7870 has a settling time of 0.9 seconds for items five pounds or less and 2 seconds for items over five pounds. The scale will not weigh items exceeding its weight class – 9.995 kg, 13.995 kg, and 30 lbs. The scale can be operated in Mode 1 or Mode 2, depending on your terminal and the type of NCR 7870. In Mode 1, the weight is displayed. In Mode 2, the weight and price are displayed.

Instructions 1. Verify display reads SCALE READY 0.000kg or SCALE READY 0.00lb and red Status Indicator is lit. 2. If display or Status Indicator is not on, press Reset/Scale Zero button. If this does not work, power unit off and on. 3. Place an item on center of Top Plate. Ensure item does not overhang. Item must rest completely on the Top Plate. 4. Item weight is displayed. Press Weight Request key on host terminal. 5. If a bad weigh occurs, re-weigh item. 6. If red Status Indicator is still lit, remove the item from Top Plate. Remove Top Plate and check for obstructing material or debris. 7. Replace Top Plate. Press Reset/Scale Zero button. 8. Wait for SCALE READY 0.000kg or SCALE READY 0.00lb. Weigh item again. 9. If no weight is displayed and/or the red Status Indicator is still lit, contact your supervisor, service company, or the NCR Customer Service Center.

Page 114

6-10

Chapter 6: Operation

Changing the Good Read Tone The volume of the Good Read Tone can be changed while in normal operating mode. This is the only characteristic of the tone that can be changed without being in Programming Mode.

Instructions 1. Scan the Volume Adjustment tag and listen to the tone. 2. If the tone is not loud enough, scan the tag again. Repeat if necessary. 3. If the tone is too loud, scan the tag repeatedly until the volume resets to the lowest level. Now scan to the desired level. 4. When the volume is acceptable, scan the Save and Reset tag to end. If the Save and Reset tag is not scanned, the unit will not operate.

Page 115

Chapter 6: Operation

6-11

Routine Maintenance Routine maintenance is needed at least once a day to keep the NCR 7870 in good operating condition. These parts of the 7870 can be cleaned with a soft cloth, lukewarm water, and mild soap: •

Scanner body

•

Top Plate and Scan Window

•

Exterior surface of Subplate Assembly

•

Optics Assembly Window

•

Horizontal Scan Window

•

Tower Cabinet

If a scan window becomes excessively scratched, replace it. If the unit becomes wet due to a spill, clean and dry as soon as possible.

Instructions Clean the Top Plate and Scan Windows with a soft cloth and a nonabrasive liquid window cleanser as follows. 1. Power unit down. 2. Remove Top Plate. Clean Top Plate and the inset Scan Window. 3. Clean window inset in Optics Assembly. Note: Do not spray the cleanser directly on plastic cover or scale mechanism holes. 4. Clean vertical Scan Window in Tower Cabinet. 5. Wipe surfaces with a soft, dry cloth. 6. Replace Top Plate. 7. Restore power to the NCR 7870.

Page 116

6-12

Chapter 6: Operation