For the NCR 7870

Page 117

Chapter 7: Programming

General This chapter is intended to acquaint you with programming the NCR 7870. It covers the overall programming process for the NCR 7870. The NCR 7870 Scanner/Scale is fully programmable to meet your system requirements and is already programmed with the factory-set default values when shipped. However, if programming changes are needed, the procedure is very simple. This chapter is divided into five sections. •

•

How to Program the NCR 7870 which describes •

Creating the Program,

•

Programming Mode,

•

Programming Tags,

•

Programming Entry Example, and

•

Programming Tips.

Program Parameter Descriptions covers the properties and uses of the programmable features that make the NCR 7870 flexible and userfriendly. This section describes •

Specific Parameters,

•

Programming Instructions for each Parameter

•

Default Parameter Settings, and

•

Programming Example using a Programming Worksheet.

Page 118

7-2

Chapter 7: Programming

•

•

•

PACESETTER Plus Information covers the use, programming, and interpretation of PACESETTER Plus including •

Modes – Inquiry, Real-Time, and Normal

•

Host Access to Tallies, and

•

Host Reset of Tallies.

Special Programming discusses functions that fall outside of normal programming such as •

Delay Weight Data to IBM Host Terminal,

•

EAN/JAN/UPC Multi-Symbol Scanning Parameters,

•

Early Beep Disable,

•

Good Read Tone Presets,

•

Good Weigh Tone When Transmitting Data, and

•

Terminal Coupon Interface Parameters.

ASCII Code Chart, which is referenced several times, is the last section in this chapter.

Page 119

Chapter 7: Programming

7-3

How to Program the NCR 7870 Creating the Program Creating a program consists of three basic steps.

Step 1. Writing the Program a)

Identify Your Requirements. The first thing you need to do is to determine the requirements of your NCR 7870 installation. This includes information about the communications protocol, the types of bar codes you scan, the use of Good Read tones, and scanner time-outs.

b)

Complete the Programming Worksheets. Using the descriptions contained in this document, complete each programming worksheet. Write the entries of your program in the space provided. Refer to Programming Modes for specific information about each parameter.

Step 2. Entering the Program a)

Enter the Base Programming State. Scan the Programming Mode tag. This must be the first tag scanned after supplying power to the NCR 7870.

b)

Enter the Parameters for each Specific Programming Mode. Scan the two Hex tags to select a Specific Programming Mode, then enter all parameter data for it. After you have entered all the information, the NCR 7870 returns to the Base Programming State. Repeat this procedure for each Specific Programming Mode that needs changed. You do not need to enter a specific programming mode if its associated programming is already correct.

Page 120

7-4

Chapter 7: Programming

Step 3. Save the Program a)

Scan the Save and Reset Tag. When you scan the Save and Reset tag, the scanner saves all programming parameters that you entered. This becomes the new scanner program. The scanner goes through initial startup and operates using the new program.

b)

Save your Programming Worksheets. Be sure to save your programming worksheets that contain the scanner program. It is much easier to reenter the program, or change some of it, if you have a written record of the existing program.

Page 121

Chapter 7: Programming

7-5

Programming Mode The NCR 7870 Scanner/Scale is programmed in the Programming Mode. You enter this mode by scanning the Programming Mode tag as the first tag scanned immediately after applying power to the NCR 7870. This puts the NCR 7870 in the Base Programming State. As a result, the NCR 7870 produces a long and then a short beep, and the status indicator stays off. From the Base Programming State you select Specific Programming Modes by scanning the proper combination of two hexadecimal tags. The program parameters that you can enter in a Specific Programming Mode are identified on the associated programming worksheet. In each Specific Programming Mode you can enter all the information contained on the worksheet by scanning the proper tags in the sequence shown on the worksheet. However, you can also use parameter shortcuts to enter only specific parameters. Program entry then goes directly to a specific parameter when you scan the proper Hex tag. The NCR 7870 accepts programming tags only in the Programming Mode. If you scan a programming tag during normal operation, nothing happens. Normal Normal Operating Operating Mode Mode

Programming Mode

Base Programming State

Specific Programming Mode

Save and Reset 16402

Page 122

7-6

Chapter 7: Programming

Programming Tags After completing the worksheets, enter the information using the special programming tags contained in the NCR 7800, 7870, 7875, 7880, and 7890 Programming Tags book (BST0-2121-74). You do not need a large number of special programming tags, only 5 unique tags and 16 hexadecimal (Hex) character tags. The following identifies each programming tag, its function, and the associated indicators.

Abort Function – In Base Programming State If this tag is scanned in the Base Programming State, programming is terminated and no previously entered parameters are saved. Indication – In Base Programming State •

Short beep as soon as tag is read – Good Read tone

•

Status indicator flashes red twice

•

Four quick beeps from low to high frequency

Function – In Specific Programming Mode If this tag is scanned in a Specific Programming Mode, all parameters entered are saved and the NCR 7875 goes to the Base Programming State. Indication – In Specific Programming Mode •

Short beep as soon as tag is read – Good Read tone

•

Status indicator flashes green once

•

Programming returns to Base Programming State.

Page 123

Chapter 7: Programming

7-7

Default Function This tag causes most parameters to go to default values. However, scanning this tag does not change a few parameters, including the Communications Protocol. The Default tag must be the first tag scanned after applying power to the NCR 7870. Indication Performs power-up sequence.

End Function This tag ends certain input sequences. Since the programming mode determines the end of most sequences, this tag is not used often. Indication •

Short beep as soon as tag is read – Good Read tone

•

Status indicator flashes green once

Hex 0 – Hex F Function These 16 tags enter the selections for each of the parameters in the Specific Programming Modes. They also select the Specific Programming Mode. Indication •

Hex 0 – Short beep, different frequency from Good Read tone

•

Hex 1 through Hex F – Beeps tag value. Multiples of 4 short beeps grouped together. Others are longer

Example – Hex D is indicated by 12 short beeps (3 sets of 4) followed by 1 longer beep, for a total of 13.

Page 124

7-8

Chapter 7: Programming

Programming Mode Function This tag puts the NCR 7870 in the Base Programming State. It must be the first tag scanned after applying power to the NCR 7870, or after scanning the Default tag. Indication •

Short beep as soon as tag is read – Good Read tone

•

Long and short beep – in Base Programming State

•

Status indicator – off

Save and Reset Function This tag causes the NCR 7870 to save and start using the programming data. It is used in the Base Programming State. Indication •

Short beep as soon as tag is read – Good Read tone

•

Status indicator flashes red twice

•

Four quick beeps from low to high frequency

Page 125

Chapter 7: Programming

7-9

Program Entry Example The following example is a typical program entry procedure. 1. Apply power to the NCR 7870 Scanner/Scale. 2. Scan the Programming Mode tag. 3. Scan the two Hex tags corresponding to the worksheet number. 4. Scan appropriate Hex tags to enter parameters. Two methods are available: a)

Enter All Parameters To enter all parameters in a Specific Programming Mode, scan the two Hex codes that put the NCR 7870 in the specific mode, and then make parameter changes in the order described on the programming worksheet for that mode. In programming all parameters in a specific mode, you proceed linearly through the work sheet. When you make a change in a parameter, the scanner moves to the next parameter to be changed or it goes back to the Base Programming State if your selection ends programming in that particular Specific Programming Mode. The following figure shows how to proceed through a Specific Programming Mode where you choose to enter all parameters. This figure presents the Specific Programming Mode for the Bar Codes 2 program parameters. The figure shows how you proceed through the specific mode by entering all available parameters. Notice that if you choose to disable Code 39 bar codes, programming immediately return to the Base Programming State. However, if you select to enable Code 39 bar codes, the scanner directs you to continue entering parameter information.

Page 126

7-10

Chapter 7: Programming

BASE PROGRAMMING STATE 1

4 Bar Codes - 2 Code 39

0

1

Disable Enable

M inim um Characters Allowed

Full AS CII

2 -F

0

1

Disable Enable

Check Digit 0 1 Present Disable Enable

Transmit Check Digit

Allow Single Character Tags

0

1

Disable Enable

0

1

Disable Enable

11722 b)

Enter Specific Parameters To enter only one particular parameter in a Specific Programming Mode, scan the two numbered Hex tags that correspond to that specific mode. However, once you have entered the specific programming mode instead of immediately changing parameters with numbered Hex tags, use the lettered Hex tags to choose the one particular parameter that you want to change. After you have selected the new parameter setting, the scanner immediately returns to the Base Programming State. If you decide to do additional programming with these