Page 45

Chapter 3 Accessories Introduction The wearable terminal accessories provide a variety of product support capabilities. Accessories include cradles, cables and scanners.

Cradles • Single Slot USB cradle charges the wearable terminal main battery and a spare battery. It also synchronizes the wearable terminal with a host computer through either a serial or a USB connection.

• Four Slot Ethernet cradle charges up to four wearable terminal batteries and synchronizes the wearable terminals with a host computer through an Ethernet connection.

• Four Slot Spare Battery Charger charges up to four wearable terminal spare batteries.

Scanners • RS309 scanner • RS409 scanner.

Accessories • Headset • Headset adapter • Wrist Mount • Hip Mount.

Page 46

3-2

WT4070/90 Wearable Terminal User Guide

Single Slot USB Cradle CAUTION

Ensure that you follow the guidelines for battery safety described in Battery Safety Guidelines on page 4-2.

This section describes how to use a Single Slot USB cradle (Figure 3-1) with the wearable terminal. For USB communication setup procedures refer to the WT4090 Integrator Guide.

Scanner Placed in Well

Spare Battery

Spare Battery Charging LED Figure 3-1 Single Slot USB Cradle

CAUTION

Use only a Symbol approved power supply output rated 12 VDC and minimum 3.3 A. Use of an alternative power supply will void the product warranty and may cause product damage. See Appendix B, Regulatory Information for the power supply regulatory compliance statement.

The Single Slot USB Cradle:

• Provides 5.4 VDC power for operating the wearable terminal. • Provides USB port for data communication between the wearable terminal and a host computer or other serial devices (e.g., a printer). NOTE

The normal function of the product may be disturbed by Strong Electro Magnetic Interference (for example, static electricity). If so, simply remove and re-insert the terminal to resume normal operation. In case the function does not resume, please use the product in another location.

Page 47

Accessories

3-3

• Synchronizes information between the wearable terminal and a host computer. (With customized or third party software, it can also be used to synchronize the wearable terminal with corporate databases.)

• Charges the wearable terminal’s battery and a spare battery. • Provides a location for storing a scanner when a wearable terminal is docked in the cradle.

Battery Charging Indicators The Single Slot USB cradle can charge the wearable terminal’s main battery and a spare battery simultaneously. The wearable terminal’s amber Charge Status LED indicates the status of the battery charging in the wearable terminal. See Table 1-3 on page 1-6 for charging status indications. The amber Spare Battery Charging LED on the cradle (see Figure 3-1 on page 3-2) indicates the status of the spare battery charging in the cradle. See Table 3-1 for charging status indications. The standard capacity battery fully charges in less than four hours. Table 3-1

Spare Battery LED Charging Indicators

Spare Battery LED (on cradle)

Indication

Off

No spare battery in well; spare battery not placed correctly; cradle is not powered.

Fast Blinking Amber

Charging error: • Temperature is too low or too high. • Charging has gone on too long without completing (typically eight hours).

Slow Blinking Amber

Spare battery is charging.

Solid Amber

Charging complete.

Page 48

3-4

WT4070/90 Wearable Terminal User Guide

Four Slot Ethernet Cradle CAUTION

Ensure that you follow the guidelines for battery safety described in Battery Safety Guidelines on page 4-2.

This section describes how to use a Four Slot Ethernet cradle (Figure 3-2) with the wearable terminal. For Ethernet communication setup procedures refer to the WT4090 Integrator Guide.

Scanner Well

Figure 3-2 Four Slot Ethernet Cradle

The Four Slot Ethernet cradle:

• Connects up to four wearable terminals to an Ethernet network. • Provide 5.4 VDC power for operating the wearable terminal and charging the battery. • Simultaneously charges up to four wearable terminals (with batteries installed). You cannot ActiveSync using the Four Slot Ethernet cradle. To ActiveSync with a host computer use the Single Slot USB cradle. CAUTION

Use only a Symbol approved power supply output rated 12 VDC and minimum 9 A. Use of an alternative power supply will void the product warranty and may cause product damage. See Appendix B, Regulatory Information for the power supply regulatory compliance statement.

Page 49

Accessories

3-5

Battery Charging The four slot Ethernet cradle can charge up to four wearable terminals simultaneously. To charge the wearable terminal: 1.

Slide the wearable terminal into the wearable terminal slot.

2.

The wearable terminal amber Charge Status LED indicates the wearable terminal battery charging status. The Standard Battery usually charges in less than four hours.See Table 3-1 for charging status indications.

3.

When charging is complete, remove the wearable terminal from the cradle.

LED Charge Indications The Four Slot Ethernet cradle uses the wearable terminal amber Power LED to indicate the battery charging status. See Table 3-1 on page 3-3 for charging status indications.

Speed LED The green Speed LED lights to indicate that the transfer rate is 100 Mbps. When it is not lit it indicates that the transfer rate is 10 Mbps.

Link LED The yellow Link LED blinks to indicate activity, or stays lit to indicate that a link is established. When it is not lit, it indicates that there is no link.

Battery Charging Indicators The wearable terminal’s amber charge LED indicates the status of the battery charging in the wearable terminal. See Table 1-3 on page 1-6 for charging status indications. The standard capacity battery fully charges in less than four hours.

Page 50

3-6

WT4070/90 Wearable Terminal User Guide

Four Slot Spare Battery Charger CAUTION

Ensure that you follow the guidelines for battery safety described in Battery Safety Guidelines on page 4-2.

This section describes how to use the Four Slot Spare Battery Charger to charge up to four wearable terminal spare batteries.

Spare Battery Charging Well (4)

Spare Battery

Spare Battery Charging LEDs (4)

Figure 3-3 Four Slot Spare Battery Charger

CAUTION

Use only a Symbol approved power supply output rated 12 VDC and minimum 3.3 A. Use of an alternative power supply will void the product warranty and may cause product damage. See Appendix B, Regulatory Information for the power supply regulatory compliance statement.

Spare Battery Charging with the Four Slot Spare Battery Charger Insert the battery into a spare battery charging slot and gently press down on the battery to ensure proper contact.

Battery Charging Indicators An amber LED is provided on each battery charging well. See Table 3-2 for charging status indications.The standard capacity battery usually charges in less than four hours. Table 3-2

Spare Battery LED Charging Indicators LED

Indication

Off

No spare battery in slot; spare battery not placed correctly; cradle is not powered.

Fast Blinking Amber

Charging error: • Temperature is too low or too high. • Charging has gone on too long without completing (typically eight hours).

Slow Blinking Amber

Spare battery is charging.

Solid Amber

Charging complete.

Page 51

Accessories

3-7

RS409 Scanner To connect the RS409 scanner to the wearable terminal: NOTE

There are two RS409 configurations available. The short cable configuration connects the RS409 to the wearable terminal mounted on the arm. The extended cable configuration connects the RS409 to the WT4090 mounted on the hip.

1.

Remove the rubber plug from the wearable terminal interface connector.

2.

Connect the RS409 interface cable to the wearable terminal interface connector. If the wearable terminal is mounted on the arm, connect the cable to the interface connector closest to the wrist.

Scanner Cable Connector

Interface Connector

Figure 3-4 Connecting RS409 to Wearable Terminal 3.

If using the extended cable configuration, route the scanner cable up to the shoulder and down to the hand that the scanner mounts on. Attach two cable clips to clothing and secure cable to cable clip.

Figure 3-5 Cable Clip Installation 4.

Rotate the trigger assembly to the correct position for the hand that the scanner mounts to.

Page 52

3-8

WT4070/90 Wearable Terminal User Guide

5.

Slide the RS409 onto the index finger with the scan trigger next to the thumb.

Figure 3-6 Place the RS409 on Index Finger 6.

Tighten the finger strap.

Figure 3-7 Tightening Straps 7.

If required, cut excess finger strap material.

After connecting the scanner, warm boot the wearable terminal. See Resetting the Wearable Terminal on page 2-14 for information on performing a warm boot.