The text of a manual · part 7 of 13
WT4070/90 Wearable Terminal User Guide: Using the Wearable Terminal, pages 36 to 44
Pages 36 to 44 of 94, from WT4070/90 Wearable Terminal User Guide
The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Motorola WT4090
Page 36
2 - 10 WT4070/90 Wearable Terminal User Guide
Windows CE 5.0 Desktop The following paragraphs describe the Windows CE 5.0 desktop. Depending upon the customer’s configuration of the wearable terminal, the desktop may not be available.
Status Icons The Taskbar at the bottom of the window displays the active programs, current time, battery status and communication status.
Status Icons Desktop Button
Open Program
Start Button
Clock
Figure 2-6 Taskbar
Status icons are shown in the taskbar to indicate present status of the wearable terminal. Table 2-6 Status Icons
Status Icon
Description Indicates the current time. The clock can be toggled on and off. Select Start > Settings > Control Panel > Task and Start Menu. This icon indicates that the main battery is charging or that the wearable terminal is operating on external power. Indicates that the battery is fully charged and the wearable terminal is running on external power. This icon is displayed when the memory backup battery level is low. Charge the battery. This icon indicates that the battery is fully charged (100% charged). The battery status icons provide the battery status in 10% increments from 10% to 100%. This displays when the terminal is connected to a host computer with ActiveSync.
Page 37
Using the Wearable Terminal 2 - 11
Table 2-6 Status Icons (Continued)
Status Icon
Description Wireless connection status icon. Indicates WLAN signal strength.
Indicates that the SHIFT key is selected. Indicates that the Blue key is selected. Indicates that the CTRL key is selected. Indicates that the ALT key is selected. Indicates that the Orange key is selected. Indicates that the Gray key is selected.
Using the Keypad to Navigate Applications The wearable terminal does not have a touch screen and therefore navigation and control of an application is performed using the keypad.
Key Combinations The wearable terminal uses special key combinations to easily navigate applications. Table 2-7 lists the key combinations required to perform various application navigation and control functions. Table 2-7 Key Combinations
Action Key
Combination
Access the Start menu on the taskbar
CTRL - ESC
Switch fields within an application
TAB
Close windows or cancel operations on some applications
ESC or ALT - F4
Access the Task Manager
ALT - TAB
Switches to the next window or desktop
ALT - ESC
Access a menu bar in an application
ALT - ALT
Press a button or select a check box in an application
TAB until the item is highlighted then SPACE.
Display a pop-up context menu
ALT - ENTER
Throughout this guide you will be instructed to select an item. You must use a key combination to select that item. For example: To perform: “Select Start > Programs > Windows Explorer” 1.
Press CTRL and then ESC to open the Start menu.
Page 38
2 - 12 WT4070/90 Wearable Terminal User Guide
2.
Press the up arrow until the Programs item is highlighted.
3.
Press the Blue key and the down arrow to open the Programs sub-menu.
4.
Press the down arrow until Windows Explorer is highlighted.
5.
Press ENTER key to launch Windows Explorer.
Selecting Items When using the navigation keys to perform tasks in an application, the active item is highlighted using either a color background and/or a dashed box.
Highlighted Item
Figure 2-7 Highlighted Items
Navigating Menus Most applications have drop-down menus to perform specific functions. Use the key combination ALT - ALT to open a menu. Once the menu is open, use the up and down navigation keys to move up and down the menu and use the left and right navigation keys to move to the next menu item or open a sub-menu. When moving through a menu, items are highlighted. Once an item is highlighted, press the ENTER key to select that item.
Figure 2-8 Navigating Menus
Navigating Tabs Some applications contain multiple pages with tabs indicating each page. Use the TAB key to highlight the tab. A dashed box appears around the tab name. Use the left and right navigation keys to move to the next or previous tab.
Page 39
Using the Wearable Terminal 2 - 13
Selected Tab
Figure 2-9 Navigating Tabs
Navigating Fields To navigate from one field to another, press the TAB key. Repeated pressing of the TAB key cycles the highlighted cursor through the fields in the window.
Selecting Checkboxes and Radio Buttons To select or deselect checkboxes and radio buttons press the TAB key until the field is highlighted. Press ALT BKSP (SPACE) to select or deselect the checkbox or radio button.
Highlighted Checkbox Radio Buttons
Figure 2-10 Selecting a Checkbox or Radio Button
Selecting Items in a List Use a combination of key sequences to select items in a folder or list. To select continuous items in a folder or list: 1.
Open the folder or list.
2.
Use the scroll keys to move to the first item to select.
3.
Press SHIFT - scroll key (either up or down) to select the next item.
4.
Repeat the SHIFT - scroll key combination to select remaining items.
5.
Perform the desired function.
To select multiple items in a folder or list: 1.
Open the folder or list.
2.
Use the scroll keys to move to the first item.
3.
Press CTRL - scroll key to move within the list. The item name is outlined.
Page 40
2 - 14 WT4070/90 Wearable Terminal User Guide
4.
Repeat step 3 to move to the desired item.
5.
Press SPACE to highlight the item.
6.
Repeat steps 3 through 5 until all items are selected.
7.
Perform the desired function.
Resetting the Wearable Terminal There are two types of resets, warm boot and cold boot. A warm boot restarts the wearable terminal by closing all running programs. A cold boot also restarts the wearable terminal, but erases all stored records and entries in RAM. Data saved in flash memory or a memory card is not lost. In addition it returns formats, preferences and other settings to the factory default settings. Perform a warm boot first. This restarts the wearable terminal and saves all stored records and entries. If the wearable terminal still does not respond, perform a cold boot.
Performing a Warm Boot Hold down the Power button for approximately five seconds. As soon as the wearable terminal starts to perform a warm boot release the Power button.
Performing a Cold Boot A cold boot restarts the wearable terminal and erases all user stored records and entries that are not saved in flash memory (Application and Platform folders). Never perform a cold boot unless a warm boot does not solve the problem. NOTE
Any data previously synchronized with a computer can be restored during the next ActiveSync operation.
To perform a cold boot press and simultaneously hold the 1, 9 and Power button. Do not hold down any other keys or buttons. The wearable terminal initializes.
Page 41
Using the Wearable Terminal 2 - 15
Data Capture Wearable terminals used with an optional wearable laser scanner allow collection of data by scanning one dimensional bar codes.
Laser Scanning Wearable terminals with an optional wearable laser scanner have the following features:
• Reading of a variety of bar code symbologies, including the most popular linear, postal, and 1-D code types. • Advanced intuitive laser aiming for easy point-and-shoot operation.
Scanning Considerations Typically, scanning is a simple matter of aim, scan/decode and a few quick trial efforts master it. However, two important considerations can be used to optimize any scanning performance:
• Range Any scanning device decodes well over a particular working range, minimum and maximum distances from the bar code. This range varies according to bar code density and scanning device optics. Scanning within range brings quick and constant decodes; scanning too close or too far away prevents decodes. Move the scanner closer and further away to find the right working range for the bar codes being scanned. However, the situation is complicated by the availability of various integrated scanning modules. The best way to specify the appropriate working range per bar code density is through a chart called a decode zone for each scan module. A decode zone simply plots working range as a function of minimum element widths of bar code symbols.
• Angle Scanning angle is important for promoting quick decodes. When laser beams reflect directly back into the scanner from the bar code, this specular reflection can “blind” the scanner. To avoid this, scan the bar code so that the beam does not bounce directly back. But don’t scan at too sharp an angle; the scanner needs to collect scattered reflections from the scan to make a successful decode. Practice quickly shows what tolerances to work within. NOTE
Contact the Symbol Support Center if chronic scanning difficulties develop. Decoding of properly printed bar codes should be quick and effortless.
Scanning Bar Codes 1.
Ensure that a scan enabled application is loaded on the wearable terminal.
2.
Aim the scan exit window at the bar code.
3.
Press the trigger.
• Ensure the red scan beam covers the entire bar code. The red scan LED lights to indicate that the laser is on. The green scan LED lights. An audible beep might sound, if the application determines, to indicate the bar code was decoded successfully.
Page 42
2 - 16 WT4070/90 Wearable Terminal User Guide
Figure 2-11 Laser Scanner Aiming Pattern
Release the trigger.
4.
Scanning Tips Optimal scanning distance varies with bar code density and scanner optics.
• Hold the scanner farther away for larger symbols. • Move the scanner closer for symbols with bars that are close together. NOTE
Scanning procedures depend on the application and wearable terminal configuration. An application may use different scanning procedures from the one listed above.
Scan LED Indicator The LED on the scanner provides a visual indication of the scan status. Table 2-8 Scan LED Indicators
LED Status
Indication
Off
Not scanning.
Solid Red
Laser enabled, scanning in process.
Solid Green
Successful decode.
Page 43
Using the Wearable Terminal 2 - 17
Waking the Wearable Terminal The wake up conditions define what actions wake up the wearable terminal after it has gone into suspend mode. The wearable terminal can go into suspend mode by either pressing the Power button or automatically by control panel time-out settings. These settings are configurable and the factory default settings are shown in Table 2-9.
Table 2-9 Wakeup Default Settings
Condition for Wakeup
Power Button
Automatic Time-out
AC power is applied.
No
Yes
Wearable terminal is inserted into a cradle.
No
Yes
Wearable terminal is removed from a cradle.
No
Yes
Wearable terminal is connected to a serial device.
No
Yes
Wearable terminal is connected to a USB device.
No
Yes
Wearable terminal is disconnected from a USB device.
No
Yes
A key is pressed.
No
Yes
An attached scanner is triggered.
No
Yes
Wireless LAN activity is detected.
No
No
A headset is connected to the wearable terminal.
No
Yes
NOTE
If the battery is removed and replaced, the only way to wake up the terminal is by pressing the Power button.
Page 44
2 - 18 WT4070/90 Wearable Terminal User Guide