Page 61

When you copy this field into another field, the maximum number of characters for the final field is 2710 (or 0-100 for 9403). Allow only as many characters as you need, because extra characters use up space. Also, if you are copying into a bar code field, the maximum number of characters in the destination bar code is determined by the bar code specification (UPCA-12, EAN-13, etc.). You need to apply field options to manipulate the text entered in this field. For example, you may want to copy data from this field into another field. See "Option 4 Copy Data" in Chapter 5 for more information. In the following example, data is entered into four non-printable fields and merged to form field 5, and is then printed as a bar code. See "Merging Fields" in Chapter 5 for more information. Field 1 2 3 4 5

Data 20374 339 8 15 20374339815

Field Type Non-printable Non-printable Non-printable Non-printable Bar Code

Each non-printable text field requires a separate definition. Syntax

D,field#,# of char p

D1. D

Non-Printable Text Field.

D2. field#

Unique number from 0-999 assigned to this field. Maximum number of characters in this field: 0-2710.

D,4,20 p

Defines a non-printable text field (field #4) with a maximum of 20 characters.

Defining Fields 4-13

Page 62

Defining Constant Text Fields A constant text field is a set of fixed characters that prints on all labels. Define each constant text field separately. This field is not assigned a field number, but is counted as a field (keep this in mind, as the printer allows a maximum of 1000 fields). The characters in this field cannot be changed by batch data. Field options do not apply to constant text fields. Determine the height and the maximum width of the characters, using the tables in Appendix B, "Fonts." If you’re using proportionally spaced fonts, use the average size of the characters. Mark the pivot point of your field. This will vary, depending on how your field is justified. Syntax

C,row,column,gap,font,hgt mag, wid mag,color,alignment,char rot, field rot,"fixed char",sym set p

C1. C

Constant Text Field.

C2. row

For monospaced fonts, distance from bottom of print area to the pivot point. For proportionally spaced fonts, distance from bottom of print area to baseline of characters in the field. (Bottom exits the printer first.)

C3. column

9412/9414 ranges:

9413 range:

English

English

0 - 599

0 - 399

Distance from the lower left edge of the print area to the pivot point. 9412 range:

9413/9414 ranges:

English

English

0 - 199

0 - 399

See "Defining the Format Header" for the table of metric and dot values.

4-14 Defining Fields

Page 63

C4. gap

Number of dots between characters. Range: 0-99. Any number other than 0 or the default number affects your field width. Default spacing: Standard Reduced Bold OCRA-like CG Triumvirate Bold CG Triumvirate

3 dots 1 dot 3 dots 3 dots varies with each letter varies with each letter

C5. font

Style of font. Options: 1 Standard 10 CG Triumvirate Bold 2 Reduced 11 CG Triumvirate 3 Bold 4 OCRA-like or a valid downloaded font selector number.

C6. hgt mag

Height magnifier, 1-7 (times). Use a magnifier of 1 with proportionally spaced fonts, because characters lose smoothness at higher magnifications.

C7. wid mag

Width magnifier, 1-7 (times) Proportionally spaced fonts do not have a set width. To estimate the size of your field, use the letter "W" for the widest field or an "L" for an average width field.

C8. color

Options for standard printer fonts: B Opaque, Normal, Black, Normal D Opaque, Normal, White, Normal O Transparent, Normal, Black, Normal R Opaque, Normal, White, Normal W Opaque, Normal, White, Normal There are two types of field color overlay attributes: Transparent Opaque

The overlay field (text or constant text) does not block out (or "erase") existing fields. The overlay field blocks out (or "erases") existing fields.

Field placement in the packet is an important consideration when using field color attributes, because fields are imaged in the order they are received. If a line field is defined before the overlay (text or constant text) field, the line field is blocked out by the overlay field, depending on the overlay field’s color attribute. If a line field is defined after the overlay field, the line field is not blocked out by the overlay field, regardless of the overlay field’s color attribute.

Defining Fields 4-15

Page 64

C9. alignment

Alignment of constant text in the field. Options: L B E

C10. char rot

Character rotation. Options: 0 1 2 3

C11. field rot

Align on left side of field. Align at midpoint of field Align at end of field.

Top of character points to top of field Top of character points to left of field Top of character points to bottom of field Top of character points to right of field

Field rotation. Lower left corner of field is the pivot point. Options: 0 1 2 3

Top of overlay points to top of supply Top of overlay points to left of supply Top of overlay points to bottom of supply Top of overlay points to right of supply

NOTE: Rotation is affected by the pivot point, which varies depending on how text is justified. C12. "fixed char" Fixed characters to appear in the field. Maximum 2710 characters. Enclose in quotation marks. C13. sym set

Symbol set. Options: 0 1 437 850

Internal Symbol Set ANSI Symbol Set DOS Code Page 437 (Domestic) DOS Code Page 850 (Multilingual)

NOTE: The CG Triumvirate fonts support only the ANSI and DOS Code Page Symbol Sets. See Appendix C, "Symbol Sets/ Code Pages," for more information.

Example

C,30,10,0,1,1,1,B,L,0,0,"MADE IN USA",0 p

Defines a constant text field starting at row 30, column 10. It does not have any additional inter-character gap. The Standard font is used without any additional magnification. The printing is black on white and left justified. No field or character rotation is used. "MADE IN USA" is printed in this field. The internal symbol set is used.

4-16 Defining Fields

Page 65

Defining Line Fields Use lines to form borders and mark out original prices. Define each line separately. This field is not assigned a field number, but is counted as a field (keep this in mind, as the printer allows a maximum of 1000 fields per format). You can define any line length and a thickness up to 99 dots, as long as the solid black print does not exceed 30 percent of any given square inch of the label.

L i n e Ty p e s You can create horizontal and vertical lines. There are two ways to define lines. Segments

You choose the starting point and ending point.

Vectors

You choose the starting point, the angle, and the length of the line.

Syntax

L,type,row,column,angle/end row,length/ end col,thickness,"pattern" p

L1. L

Line Field.

L2. type

Type of line. Only vertical and horizontal lines are supported. Options: S

Segment. You choose the starting point and ending point.

V

Vector. You choose the starting point, angle, and length.

Defining Fields 4-17

Page 66

L3. row

Distance from bottom of print area to the starting point. 9412/9414 ranges: English

0 - 599

9413 range: English L4. column

0 - 399

Distance from left edge of the print area to line origin. 9412 range: English

0 - 199

9413/9414 ranges: English

0 - 399

See "Defining the Format Header" for the table of metric and dot values. L5. angle/ end row

If Using Segments Row location of ending point. Measure from bottom of print area. Ranges same as row above. On horizontal lines, this value must match item L3. If Using Vectors Angle of line. Options: 0, 90, 180, or 270.

L6. length/ end col

If Using Segments Column location of end point. Measure from left edge of print area. Ranges same as column above. On vertical lines, this value must match parameter L4. If Using Vectors Length of the line in selected units. Ranges for horizontal lines with 9412: English

4-18 Defining Fields

0 - 200

Page 67

Ranges for horizontal lines with 9413/9414: English

0 - 400

Ranges for vertical lines with 9412/9414: English

0 - 600

Ranges for vertical lines with 9413: English L7. thickness

0 - 400

Using the chart below for reference, write the desired line thickness (1 to 99) in box L7. Measured in dots.

NOTE: Line thickness fills upward on horizontal lines, or to the right on vertical lines. L8. "pattern"

Example

Line pattern. Enter "".

L,S,110,30,110,150,10,"" p

Defines a horizontal line field as a segment starting at row 110, column 30 and ending at row 110, column 150. The line thickness is 10 dots.

Defining Fields 4-19

Page 68

Defining Box Fields Use boxes to form borders or highlight items of interest. Define each box field separately. This field is not assigned a field number, but is counted as a field (keep this in mind, as the printer allows a maximum of 1000 fields). You can define any line length and a thickness up to 99 dots, as long as the solid black print does not exceed 30 percent of any given square inch of the label. Syntax

Q,row,column,end row,end col,thickness, "pattern" p

Q1. Q

Box (Quadrilateral) Field.

Q2. row

Distance from bottom of print area to lower left corner of box. 9412/9414 ranges: English

0 - 599

9413 range: English Q3. column

0 - 399

Distance from left edge of print area to lower left corner of box. 9412 range: English

0 - 199

9413/9414 ranges: English

0 - 399

See "Defining the Format Header" for the table of metric and dot values. Q4. end row

4-20 Defining Fields

Distance from bottom of print area to upper right corner of box. Ranges same as row.

Page 69

Q5. end col

Distance from left edge of print area to upper right corner of box. Ranges same as column.

Q6. thickness

Using the chart below for reference, write the desired line thickness (1 to 99) in box Q6. Measure in dots.

NOTE: Boxes fill inward, so make sure your boxes do not overwrite other fields. Q7. "pattern"

Example

Line pattern. Enter "".

Q,240,30,270,150,3,"" p

Defines a box field starting at row 240, column 30. It ends at row 270, column 150. It has a thickness of 3 dots.

Defining Fields 4-21

Page 70