Page 71

DEFINING FIELD OPTIONS

5

This chapter provides a reference for defining u field options in formats.

u check digit packets.

Applying Field Options Field options further define text, bar code, and non-printable text fields. The text, constant text, or bar code field must be previously defined before you can apply any field option to it. Define options immediately after the field to which they apply.

Combining Field Options You can use more than one option with most fields. For example, you can use Option 4 to copy data from another field, and then use Option 30 to pad the field. When you use multiple options for the same field, you must place the options in the order you want to apply them to your format.

Defining Field Options 5-1

Page 72

Restrictions Some options cannot be used together. For example, incrementing (Option 60) and price field (Option 42) options cannot be applied to the same field. Refer to the following sections addressing individual options for specific combinations to avoid. Option 4 (copy a field) is the only option that can be repeated for a single field. Example

R,1,3,1,3,1,1 p

Syntax

R,option#,parameter...parameter p

R1. R

Indicates field option header.

R2. option#

Option number (supported on all printers): 1 4 30 31 42 50 51 52 60 61

Define fixed characters Copy data from previous field Pad data to left or right with specified character Generate check digit Format as a price field Define bar code densities Define security and truncation of PDF417 bar codes Define width or length of PDF417 bar codes Define incrementing or decrementing field Reimage fields

R3. parameter(s) Varies per option. See the following option descriptions.

5-2 Defining Field Options

Page 73

Option 1 (Fixed Data) Fixed data is information (a company name or store number) you want to print on all labels. You can define fixed characters for an entire field or for part of a field. Syntax

R,1,"fixed char" p

R1. R

Option Header.

R2. 1

Option 1.

R3. fixed char

Characters to insert. Enclose in quotation marks. If you are defining fixed characters for part of a field, place underscores (_) in non-fixed positions. Any spaces in the phrase are fixed characters. Range: 0 - 2710. NOTE: Underscore characters are stripped out and the data is compressed if no data is supplied by the batch and the field length is variable.

Example

R,1,"_ _ _%$_ _ _ _ _" p

Uses fixed characters (%$) in positions four and five. positions are variable. Example

The other

R,1,"MONARCH" p

"MONARCH" appears as a fixed field in this example. To fill in the non-fixed portion of the field, see "Defining Batch Data Fields" in Chapter 6. As an alternative, you can apply Option 4 to copy data into the non-fixed character positions.

Defining Field Options 5-3

Page 74

Option 4 (Copy Data) You can create a field that uses data from another field. This is useful for creating merged fields or sub-fields. You can copy the information from multiple fields into one field by applying the copy procedure more than once. Copy data is the only option you can apply to a field more than once. The maximum number of characters defined in box T3 or B3 must allow for the number of characters you will place in the field, including any price, check digit, or fixed characters inserted by the printer. The maximum number of characters in the destination field (including copied data) cannot exceed 2710 or the maximum number of characters permitted by the bar code. When copying from more than one field, copy into the destination field from left to right. Syntax

R,4,src fld,src start,# to copy,dest start,copy code p

R1. R

Field Option Header.

R2. 4

Option 4.

R3. src fld

Field number from which data is copied. Range: 0 - 999.

R4. src start

Position number in the source field of the first character to be copied. Character positions are numbered 1 to 2710, starting from the left.

R5. # to copy

Number of characters to copy. Range: 1 - 2710.

R6. dest start

Position number where copied characters are to begin printing in the destination field. Range: 1 - 2710.

R7. copy code

Copy Method.

5-4 Defining Field Options

1

Copy field as is (including price symbols, pad characters, check digits, etc.).

2

Copy unformatted data (without price characters, pad characters, etc.).

Page 75

R,4,3,1,3,1,1 p

Example

Copies data from field #3, starting at the first position and copying three characters. In the destination field, the information is placed in position 1 and copied as formatted data.

Merging Fields You can copy data to merge the contents of fields. Use the copy data option as many times as necessary to copy all the appropriate fields into the merged field. In the following example, two text and two non-printable fields are shown. Data from these fields is merged to form field 5 and is then printed as a bar code. Field 1 2 3 4 5

Data

Field Type

203 339 8 BLUE 2033398BLUE

Non-printable Non-printable Text Text Bar Code

To create this sequence: 1. Define fields 1, 2, 3, and 4. 2. Define field 5 as a bar code. Allow enough characters in the bar code field to hold all the copied characters. 3. Apply Option 4 to field 5 once for every source field.

Sub-Fields You can copy a segment of data from one field into a new location, called a sub-field. For example, extract part of the data in a bar code and display it in text form in a sub-field. Then, use the copy data option.

Defining Field Options 5-5

Page 76

Option 30 (Padding Data) You can add characters to one side of a field to "pad" the field. Padding allows you to fill in the remaining spaces when the entered data does not fill an entire field. If a variable length field is not completely filled with batch data, this option fills the remaining positions in the field with the character designated by Option 30. Syntax

R,30,L/R,"character" p

R1. R

Option Header.

R2. 30

Option 30.

R3. L/R

Indicates type of padding

R4. "character"

L

Pad field on left side

R

Pad field on right side

Pad character must be within the 0 - 255 decimal range and enclosed inside quotation marks. NOTE: Do not use on fixed length fields.

Example

R,30,L,"X" p

Pads data with an "X" on the left side of the field.

Sample Use for Padding If you have a variable length bar code that you want to occupy a fixed amount of space on the supply, use pad characters. If the maximum number of characters in the bar code is 15, but the batch record only has 10 characters, the padding option fills the remainder of the field with pad characters.

5-6 Defining Field Options

Page 77

Option 31 (Calculate Check Digit) The printer generates a check digit if you apply Option 31 to the field. You cannot use this option if the field contains a UPC, EAN, or Code 39 (with the MOD43 check digit) bar code. Syntax

R,31,gen/ver,check digit # p

R1. R

Option Header.

R2. 31

Option 31.

R3. gen/ver

Enter G to generate a check digit.

R4. check digit # Specifies a check digit scheme. Enter a number that identifies a check digit scheme that has been defined. For more information, see "Using Check Digits." Range: 1 - 10.

Example

R,31,G,5 p

Generates a check digit using the previously defined check digit scheme 5.

Defining Field Options 5-7

Page 78

Option 42 (Price Field) You can apply options that will insert monetary symbols automatically. Do not use this option with Option 31 (define a check digit) or Option 60 (increment or decrement a field). This option is not recommended for bar codes. When determining the maximum number of characters, add the maximum number of digits and the monetary symbols. Syntax

R,42,appearance code p

R1. R

Option Header.

R2. 42

Option 42.

R3. appearance code

Enter 1 to print price field in standard notation, as defined by country setting. Use the monetary formatting packet to select monetary notations and symbols by country setting. See "Defining the Monetary Formatting Packet" for more information. See Appendix C, "Symbol Sets/Code Pages," to make sure the monetary symbol you want to use is printable in the font selected for this field. For monetary symbols other than the dollar sign, use the internal symbol set.

Example

R,42,1 p

Uses a price field that prints the monetary symbol and notations as defined in the monetary formatting packet.

5-8 Defining Field Options

Page 79

Option 50 (Bar Code Density) You can apply this option to bar code fields when you want to create custom densities. When you apply this option, it overrides the density value in the bar code field. When using this option, set the density parameter in your bar code field to the default value. You can only use this option once for each bar code field. This option overrides the density selected in the bar code field. Bar codes produced using Option 50 may not be scannable. The additional character gap, narrow space, and wide space parameters are valid only with Code 39 and Codabar. If these parameters are specified for any other bar codes, they will be ignored by the printer. Do not use Option 50 with fixed density bar codes. Syntax

R,50,narrow,wide,gap,nar_space,wide_space p

R1. R

Option Header.

R2. 50

Option 50.

R3. narrow

Dot width of the narrow element. Range: 1-99.

R4. wide

Dot width of the wide element. Range: 1-99.

R5. gap

Additional dot space between characters. Enter a value of 1 to 99. (Code 39 and Codabar only.)

R6. nar_space

Additional dot width of the narrow bar code space. (Code 39 and Codabar only). Range: 1- 99.

R7. wide_space

Additional dot width of the wide bar code space. (Code 39 and Codabar only). Range: 1- 99.

Example

R,50,4,8,4,4,8 p

Creates a custom bar code density with a narrow element of 4 dots, a wide element of 8 dots, a gap of 4 dots, 4 additional dot widths for the narrow bar code space, and 8 additional dot widths for the wide bar code space (if this is a Code 39 or Codabar bar code).

Defining Field Options 5-9

Page 80

O p t i o n 5 1 ( P D F 4 1 7 S e c u r i t y / Tr u n c a t i o n ) You can define a security level and choose whether or not to truncate a PDF417 bar code. Higher security levels add data to a bar code, improving scan reliability. Some damaged bar codes may still be scannable if the security level is high enough. You can use this option to create standard PDF417 bar codes or use the truncated option to create a narrower bar code. This option can appear only once per PDF417 field, in any order, following the bar code field. As the security level is increased, so is the size of your PDF417 bar code. For each level increased, the bar code will double in size. Syntax

R,51,security,stand/default p

R1. R

Option Header.

R2. 51

Indicates Option 51.

R3. security

Security level ranges from 0-8 (0 is the default). Higher security levels add data to a bar code, improving scan reliability. Some damaged bar codes may still be scannable if the security level is high enough.

R4. stand/def

Truncation selector. Valid values: S T

Example

(default) a standard PDF417 bar code truncated

R,51,2,S p

Defines a security level of 2 for a standard PDF417 bar code.

5-10 Defining Field Options