Page 51

F7. width

F8. "name"

Example

Supply width, from left to right, in selected units. 9412 range:

9413/9414 ranges:

English

English

120 - 200

120- 400

Format name (optional), 0-8 characters, enclose within quotation marks.

{F,1,A,R,E,300,200,"TEXTILES" p

Adds Format 1 ("TEXTILES") to the printer. It uses a three inch long by two inch wide label.

Defining Text Fields Create a separate definition for each text field. If text falls on two lines, each line of text requires a separate definition. Syntax

T,field#,# of char,fix/var,row,column, gap,font,hgt mag,wid mag,color,alignment, char rot,field rot,sym set p

T1. T

Text Field.

T2. field#

Unique number from 0-999 to identify this field.

T3. # of char

Maximum number of printed characters is 0-2710 in the field.

T4. fix/var

Fixed or variable length field. Options: F Fixed length V Variable length

T5. row

For monospaced fonts, distance from bottom of print area to the pivot point. The pivot point varies depending on how text is justified. For proportionally spaced fonts, distance from bottom of print area to baseline of characters in field.

Defining Fields 4-3

Page 52

9412/9414 ranges: English

0 - 599

9413 range: English T6. column

0 - 399

Distance from the left edge of the print area to the pivot point to find the column location. 9412 range: English

0 - 199

9413/9414 ranges: English

0 - 399

See "Defining the Format Header" for the table of metric and dot values. T7. gap

Number of dots between characters (203 dots per inch). Range: 0-99. NOTE: For monospaced fonts, the additional spacing is added to the existing inter-character gap. This is also true for proportionally spaced fonts, but remember that the inter-character gap varies with character combinations. Any number other than 0 or the default number affects your field width. Default spacing: Standard Reduced Bold OCRA-like CG Triumvirate Bold CG Triumvirate

T8. font

3 dots 1 dot 3 dots 3 dots varies with each letter varies with each letter

Style of font. Options: 1 2 3 4

Standard Reduced Bold OCRA-like

10 11

CG Triumvirate Bold CG Triumvirate

Or a valid downloaded font selector number.

4-4 Defining Fields

Page 53

T9. hgt mag

Height magnifier, 1-7 (times). Use a magnifier of 1 with proportionally spaced fonts, because characters lose smoothness at higher magnifications.

T10. wid mag

Width magnifier, 1-7 (times). Proportionally spaced fonts do not have a set width. To estimate the size of your field, use the letter "W" for the widest field or an "L" for an average width field. Find your selected font and the desired width in Appendix B, "Fonts."

T11. color

Options for standard printer fonts: B D O R W

Opaque, Normal, Black, Normal Opaque, Normal, White, Normal Transparent, Normal, Black, Normal Opaque, Normal, White, Normal Opaque, Normal, White, Normal

There are two types of field color overlay attributes: Transparent Opaque

The overlay field (text or constant text) does not block out (or "erase") existing fields. The overlay field blocks out (or "erases") existing fields.

Line field blocked out by opaque field using attribute B

Line field not blocked out by transparent field using attribute O

Field placement in the packet is an important consideration when using field color attributes, because fields are imaged in the order they are received. If a line field is defined before the overlay (text or constant text) field, the line field is blocked out by the overlay field, depending on the overlay field’s color attribute. If a line field is defined after the overlay field, the line field is not blocked out by the overlay field, regardless of the overlay field’s color attribute.

Defining Fields 4-5

Page 54

T12. alignment

Options: L C R B E

Align on left side of field. Center text within field (monospaced fonts only) Align on right side of field (monospaced fonts only) Align at midpoint of field Align at endpoint of the field

Use L, B, or E for any font. T13. char rot

Character rotation. The field or supply does not rotate, only the characters do. Options: 0 1 2 3

T14. field rot

Field rotation. Field rotation rotates the whole field, not just the characters. Rotation is affected by the pivot point, which varies depending on how text is justified. Lower left corner of field is the pivot point. Options: 0 1 2 3

T15. sym set

Top of character points to top of field Top of character points to left of field Top of character points to bottom of field Top of character points to right of field

Top of field points to top of supply Top of field points to left of supply Top of field points to bottom of supply Top of field points to right of supply

Symbol set. Options: 0 1 437 850

Internal Symbol Set ANSI Symbol Set DOS Code Page 437 (Domestic) DOS Code Page 850 (International)

NOTE: The CG Triumvirate fonts support only the ANSI and DOS Code Page Symbol Sets. Refer to Appendix C, "Symbol Sets/ Code Pages" for more information.

4-6 Defining Fields

Page 55

T,2,10,V,250,50,0,1,1,1,B,C,0,0,0 p

Example

Defines a text field (field #2) with a variable length of up to 10 characters. The field begins at row 250, column 50. There is no additional gap between characters, and the Standard font is used without any additional magnification. The printing is black on white and centered. No field or character rotation is used. The internal symbol set is used.

Defining Bar Code Fields Each bar code field requires a separate definition. Syntax

B,field#,# of char,fix/var,row,column, font,density,height,text,alignment, field rot p

B1. B

Bar Code Field.

B2. field#

Unique number from 0-999 to identify this field.

B3. # of char

Maximum number of characters. If the bar code uses a check digit, allow an extra character for the check digit. The actual maximum number of characters is limited by the size of the label and bar code density. Range: 0-2710.

B4. fix/var

Fixed (F) or variable (V) length field. Number of Characters

Fixed/Variable

UPCA

Bar Code

12

F

UPCA+2

14

F

UPCA+5

17

F

UPCE

7

F

UPCE+2

9

F

UPCE+5

12

F

EAN8

8

F

EAN8+2

10

F

EAN8+5

13

F

EAN13

13

F

EAN13+2

15

F

Defining Fields 4-7

Page 56

EAN13+5

18

F

POSTNET

9 or 11

F

Interleaved 2 of 5

0 to 2710

V

Code 39 or MOD43

0 to 2710

V depends on application

V

Code 128

0 to 2710

V

Codabar (NW7)

Code 93

0 to 2710

V

PDF417

0 to 2710

V

MaxiCode

15 to 99

V

B5. row

Distance from bottom of the print area to the pivot point of the field. The pivot point varies, depending on how the field is justified. Pivot points:

Left/Center/Right-Justified Fields

Balanced Fields

End-Justified Fields

Remember to include text or numbers that may appear with the bar code for the row measurement. 9412/9414 ranges: English

0 - 599

9413 range: English

4-8 Defining Fields

0 - 399

Page 57

B6. column

Distance from the lower left edge of the print area to the pivot point. 9412 range: English

0 - 199

9413/9414 ranges: English

0 - 399

See "Defining the Format Header" for the table of metric and dot values. NOTE: Allow a minimum of 1/10 inch between the scan edge of bar code and label edges or other data. B7. font

Bar code. Options: 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 22 23 32 33 40

UPCA UPCE Interleaved 2 of 5 Code 39 (no check digit) Codabar EAN8 EAN13 Code 128 UPCA +2 UPCA +5 UPCE +2 UPCE +5 EAN8 +2 EAN8 +5 EAN13 +2 EAN13 +5 POSTNET Code 93 PDF417 MaxiCode Code 39 (MOD 43 check digit)

NOTE: For more information about the MaxiCode bar code, see Appendix A, "Samples." B8. density

Bar code density. Use the following table for the bar code density.

Defining Fields 4-9

Page 58

Bar code Type

Density Selector

Density (% or cpi)

Narrow Element (dots/mils)

Narrow to Wide Ratio

Data Length

Appearance Codes Available

Char Set

UPCA +2/+5 2 4

76% 114%

2/9.9 3/14.8

1.0:1

11 or 12 14/17

1, 5, 6, 7 or 8 0 to 9

UPCE +2/+5

2 4

76% 114%

2/9.9 3/14.8

1.0:1

6 or 7 9/12

1, 5, 6, 7 or 8 0 to 9

EAN8 +2/+5

2 4

76% 114%

2/9.9 3/14.8

1.0:1

7 or 8 10/13

1, 5, 6, 7 or 8 0 to 9

EAN13+2/+5 2 4

76% 114%

2/9.9 3/14.8

1.0:1

12 or 13 15/18

1, 5, 6, 7 or 8 0 to 9

Interleaved 2 of 5

1 2 3

1.1 2.1 3.2

21/103.4 12/59.1 7/34.5

1:3.0 1:2.5 1:3.0

0 to 2710

8

0 to 9

4 5 6

4.2 5.6 6.3

6/29.6 4/19.7 4/19.7

1:2.5 1:3.0 1:2.5

7 8 9

7.5 8.8 9.6

3/14.8 3/14.8 3/14.8

1:3.0 1:2.3 1:2.0

10 11 12

11.2 11.0 12.7

2/9.9 2/9.9 2/9.9

1:3.0 1:3.0 1:2.5

13

14.5

2/9.9

1:2.0

Code 39 or MOD43 (Extended Code 39)

1 2 3 4 6 7 11 12 20

1.4 1.7 3.5 4.2 6.3 7.0 3.9 12.7 3.0

10/49.3 8/39.4 4/19.7 3/14.8 2/9.9 2/9.9 4/19.7 1/4.9 5/24.6

1:2.5 1:2.5 1:2.5 1:3.0 1:3.0 1:2.5 1:2.0 1:3.0 1:2.2

0 to 2710

8

SPACE $%*+-./ 0 to 9 A to Z

Codabar (NW7)

2 3 4 5 7 8 9

2.1 3.0 4.6 5.1 8.4 9.2 10.1

8/39.4 6/29.6 4/19.7 4/19.7 2/9.9 2/9.9 2/9.9

1:3.0 1:2.5 1:2.5 1:2.0 1:3.0 1:2.5 1:2.0

0 to 2710

8

$+-./ 0 to 9 a to d

Code 128

20 4 6 8

3.5/7.0 4.4/8.7 5.8/11.7 8.7/17.5

5/24.6 4/19.7 3/14.8 2/9.9

N/A

0 to 2710

8

00H to 7FH

NOTE: The start (*) and stop (+) characters are automatically added for Code 39. Code 39, density 12 produces a one-dot narrow bar. This density is for special U.S.P.S. ACT-tag applications only. Synthetic supplies are recommended to produce scannable bar codes.

4-10 Defining Fields

Page 59

Bar code Type

Density Selector

Density (% or cpi)

Narrow Element (dots/mils)

Narrow to Wide Ratio

CODE 93

3 4 5 7 10

3.7 4.5 5.6 7.5 11.2

6/29.6 5/24.6 4/19.7 3/14.8 2/9.9

N/A

Bar code Type

Density Selector

Density (% or cpi)

Narrow Element (dots/mils)

Narrow to Wide Ratio

POSTNET

0 (fixed at 4.3 cpi)

24/118.2

10/49.3

Maxicode

7

N/A

N/A

Bar code Type

Density Selector

Element Width (dot/mils)

Row Height (dots/mils)

Appearance Codes Available

Char Set

8

00H to 7FH

Appearance Codes Available

Char Set

4/19.7 0,5,6,9 or (5 dot gap) 11

8

0 to 9

N/A

8

00H to FFH

Appearance Codes Available

Char Set

PDF417

1 2 3 4 5 6 7 8 9

2/9.8 2/9.8 2/9.8 3/14.8 3/14.8 3/14.8 4/19.7 4/19.7 4/19.7

2/9.8 4/19.7 6/29.6 3/14.8 6/29.6 9/44.3 4/19.7 8/39.4 12/59.1

8

00H to FFH

Aspect Ratio 1:1 1:2 1:3 1:1 1:2 1:3 1:1 1:2 1:3

Data Length 0 to 2710

Data Length

15 to 99

Data Length 0 to 2709

NOTE: Values in bold indicate the default.

B9. height

Bar code height in 1/100 inches, 1/10 mm, or dots. Minimum values: English Metric Dots

20 51 40

NOTE: POSTNET, PDF417, and MaxiCode bar codes have a fixed height. Always use 0 for these bar codes.

Defining Fields 4-11

Page 60

B10. text

Appearance of text with bar code. For UPC and EAN only use 0-7. For all others, use 8. Options: 0 1 5 6 7 8

B11. alignment

Default No check digit or number system Number system at bottom, no check digit Check digit at bottom, no number system Check digit and number system at bottom No text, bar code only

Choose L, R, C, B or E to align the bar code data correctly in the field. B centers variable width bar codes, which may not allow pad-character centering (Code 128, Code 39, etc.) E right justifies variable width bar codes. C centers the bar code data in the field. R right justifies the bar code data in the field. MaxiCode must use L. NOTE: All alignments are not supported for each bar code type.

B12. field rot

Field rotation. Field rotation rotates the whole field, not just the characters. Rotation is affected by the pivot point, which varies depending on how text is justified. Lower left corner of field is the pivot point. Options: 0 1 2 3

Example

Top of field points to top of supply (Use for MaxiCode) Top of field points to left of supply Top of field points to bottom of supply Top of field points to right of supply

B,3,12,V,150,40,1,2,80,7,L,0 p

Defines a bar code field (field #3) with 12 characters of variable length starting at row 150, column 40. A UPCA bar code with a density of 2 and a height of 80 is used. The check digit and number system are shown at the bottom. The bar code is left aligned without any field rotation.

Defining Non-Printable Text Fields Non-printable text fields allow you to enter data without printing it in its entered form. Typically, non-printable fields "hold" data that later combines with other fields to form a merged field. Define non-printable text fields before you define the field where the information prints.

4-12 Defining Fields