Page 43
USE AND FUNCTIONING
3.8.1
3
PC IrDA to Terminal IrDA Connection
For this connection, the Minec 4x IrDA port can be used for ActiveSync by placing it within the range of the PC IrDA port. The necessary drivers are already installed on the PC.
3.8.2
Cradle Connection
The ActiveSync connection can also be made using the Minec 4x Cradle. In this case, to guarantee a correct connection between the host and the Minec 4x terminal through the Minec 4x cradle, the necessary RS232 driver has to be installed, and is either already present in the operating system, or can be installed from the CD-ROM. In order to install the RS232 driver, it is necessary to have at least the following: PC with a Pentium processor; One of the following operating systems: Windows 2000 Windows XP Once the RS232 driver has been installed, the communication between PC and cradle will be performed through a virtual Infrared port. NOTE
Before performing the installation, ensure that the Minec 4x cradle has already been connected to the PC serial port. 1.
Start the “Add/Remove Hardware Wizard” in the PC Control Panel:
25
Page 44
3
Minec 4x
2.
Select “Yes, I have already connected the hardware”:
3.
Select the “Add a new hardware device” option from the list below to add the new driver:
4.
Choose the option allowing to manually select the hardware to be installed:
26
Page 45
USE AND FUNCTIONING 5.
Select “Infrared device” as hardware type:
6.
Select “Vishay Telefunken” as Infrared device to be installed:
3
Then, a further window will appear to confirm the selection of the infrared device. 7.
Select the COM port to which you are installing the selected infrared device:
27
Page 46
Minec 4x
3 8.
Click on the “Finish” button to complete the procedure:
Only one infrared device at a time must be active. To disable other infrared devices, use the Device Manager available in the Control Panel\System\Hardware folder. NOTE
3.8.3
RF Remote Connection
For RF models, it is possible to make a remote connection as follows: 1.
A partnership must be established between the terminal and the PC using one of the methods previously described (PC IrDA to Terminal IrDA Connection or Cradle Connection).
2.
Disconnect the ActiveSync connection.
3.
Perform the Save Registry procedure as described in par. 3.7.1.
4.
Launch the "repllog /remote" command from the Run Menu (available from the Start Button).
5.
In the dialog box that will appear, it will be possible to choose a method to connect to the PC. Choose Network Connection and press the Connect button.
28
Page 47
USE AND FUNCTIONING
3.9
3
BACKUP DIRECTORY FILE MANAGEMENT
All of the Windows CE system files reside in RAM (volatile memory) except for the Backup directory, which resides in FLASH (non-volatile memory). Therefore the contents of the Backup directory are persistent even if the terminal is re-booted or the battery is changed. You can save your more important files that you don't want to lose due to terminal reboot, in the Backup directory or create a sub-directory within Backup. Even though the Windows Directory resides in RAM, it often contains files or subdirectories created by the user or by installation programs that you don't want to lose at re-boot. To keep these files persistent it is necessary to copy them to the directory \Backup\Windows. This directory doesn't exist originally (only Backup exists), and therefore it must be created. At the next cold boot, before activating the shell, Windows CE will copy the contents including all sub-directories of \Backup\Windows to \Windows. Likewise, to maintain files that must be run at Windows CE startup, (i.e. .exe, .lnk, .vb, .htm, etc.), it is necessary to copy them to the directory \Backup\Startup. This directory does not exist originally (only Backup exists), and therefore it must be created. The application programs will be run after any type of re-boot (both warm and cold boot). As an alternative to the Safe Setup function, it is possible to copy the .cab files to the directory \Backup\Cabfiles (the Cabfiles sub-directory doesn't exists originally and must therefore be created) and perform a terminal cold boot to have the application installed. Once these files are copied to the directory \Backup\Cabfiles, the application will be run after each re-boot. From the second cold boot on, a message may be displayed such as "<application name> is already installed. Re-install?". This message blocks the boot process. Press the [Enter] key to continue the system initialization.
29
Page 48
Minec 4x
3
3.10 TERMINAL LED INDICATORS The Minec 4x provides two different LEDs under the display, a user programmable one on the left and a charging status one on the right of the display, signaling the terminal status as described in the following table. LED
STATUS blink
*User programmable / single blink every 2 sec. Good Read
Charging Status terminal mode in
Suspend user defined
Good Read off batteries charged red blinking battery low, precharge ongoing red constant fast charge in progress
*This LED can be programmed from the application.
30 loading Windows CE