For the Minec 4X and Datalogic Minec 4X

Page 35

USE AND FUNCTIONING

3.7

3

CONTROL PANEL

The main window of the Windows CE control panel is shown below as it appears on the terminal when launched from Start ->Settings ->Control Panel; APPLET programs are displayed on the desktop as icons; one icon corresponds to each APPLET.

3.7.1

Registry

The REGISTRY ADMIN applet provides management of Windows CE registry.

Select the REGISTRY ADMIN applet by double clicking the Registry Admin icon. The Registry Administration Main window appears. Two functions are available: -

Save Registry allows permanently saving the Windows configuration (example: custom configuration of power-off timeout, or network adapter configuration) to non-volatile memory (SAVE button)

-

Restore Default Registry allows restoring the initial factory default configuration (Restore Default button). After restoring the factory default configuration, you must perform a software reset (see par. 3.6).

17

Page 36

Minec 4x

3

Saving the registry to non-volatile memory guarantees the persistence of the Windows configuration in case of battery replacement.

3.7.2

Files Admin

The FILES ADMIN applet enables control of the permanence of files in the System Folder. Two functions are available on the Files Admin Main window by means of two buttons:

Save Session: with this button all files will be permanently saved in the \Windows directory in non-volatile memory. This function guarantees the steady maintenance of every file produced during the current working session - even of sub-directories and relevant files - with the exception of the files belonging to the FLASH image. These current working session files will be backed-up in the \Backup\Windows directory. At the next hardware reset, the files previously saved in the \Backup\Windows directory will be restored to the Windows directory (see BACKUP DIRECTORY FILE MANAGEMENT 3.9).

18

Page 37

USE AND FUNCTIONING

3

Safe Setup: with this button, the installation of software programs will be saved to non-volatile memory (Backup directory). Before doing this, it will be checked that the Backup directory has enough space to save the files. If the directory space is not enough, an error message will be shown and the program will exit the Safe Setup function. Two activating procedures are available: 1.

Select an installation file (for example, a .CAB cabinet file) from the Safe Setup mask.

Safe Setup First Mask

Then select \Windows or a relevant sub-directory in the path box. Then, Safe Setup will recognize the new files and directories present in the \Windows directory, and will copy them to the \Backup\Windows directory. At the next hardware reset, these files will be restored (see BACKUP DIRECTORY FILE MANAGEMENT 3.9).

2.

Simply skip the first mask. When it closes, a new mask will pop up: it will enable any type of installation (even remote ones like ActiveSync installations). Make sure the installation directory is \Windows or one of its sub-directories. After installation, select OK: Safe Setup will save the new files in the \Backup\Windows directory.

Safe Setup Second Mask

19

Page 38

Minec 4x

3

3.7.3

Scanner Setup

This applet, available on the Desktop, contains the configuration parameters of the barcode scanning or of the RFID reading in a directory tree structure. The available barcode / RFID parameters are divided into two groups: Reader Parameters and Scan Parameters. The Reader Parameters depend on the type of data capture collector installed on the terminal. If it is a laser module, it allows barcode configuration (i.e. enable/disable Code 39, check digit control, etc.). If it is an RFID module, it allows the selection of the tag type (i.e. ISO-15693). It is possible to select only one tag at a time. To select a different tag, this parameter must be set again. The Scan Parameters allow control of the data capturing process (i.e. beeper control, LED control, scanning timeout, etc.). Each Barcode Setup screen window corresponds to a branch of the tree, and the name of the current branch is displayed at the bottom of each screen window.

The screen format shows two columns where the left column indicates branches or parameters. Branches have three dots in the right column (...). You can navigate through the tree structure using the keyboard arrows directly on the item field or from the menu. Parameters have their corresponding current values in the right column. You can edit parameter values using the keyboard arrows directly on the item field or from the menu. To change a value for example, select the line of the value to be changed, choose Edit from the Parameter Menu then choose a new value from the values listed in the box (see following figures).

20

Page 39

USE AND FUNCTIONING

3

To activate a new configuration select the File ->Save Menu to send the new configuration to the decoding software and save the new configuration. This will save the configuration to non-volatile memory preventing loss at the next system reset.

Reader Parameters The reading parameters and values are dependent upon the type of module (laser or RFID) mounted in your terminal. For a list of default values see the following paragraph, "Default Values". For a detailed list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD.

Scan Parameters The Scan Parameters are common to all modules (laser or RFID) and allow control of the scanning device. The Scan parameters are described as follows: Scan Timeout: the maximum time, in milliseconds, during which the laser / RF emission remains on without decoding any barcode or RFID tag. Beep Duration: the time interval, in milliseconds, during which the beeper will sound when the scanner reads a barcode or RFID tag. To disable the beeper, set this value to 0. Beep Frequency: determines the frequency in Hertz of the beeper. LED Duration: determines the duration in milliseconds of each 'Good Read LED' pulse. LED Pulses: determines the number of pulses the 'Good Read LED' will blink when the scanner reads a barcode or RFID tag. Continuous Mode: when enabled, the scansion can only be turned off by the application program if Soft Trigger is enabled. Continuous Mode overrides Scan Timeout.

21

Page 40

Minec 4x

3

Keyboard Emulation: if enabled all scanned data are transformed into keyboard events and can therefore be displayed and saved to a file as if input from the terminal keyboard. Soft Trigger: when enabled, the scansion can be turned on/off by the application software. Scan Always On: enables the scanner for barcode or RFID tag reading independently from the application software.

Default Settings The following tables contain the default values for the major barcode setup / RFID parameters. For a complete list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD.

Laser Scanner Parameters

22

SCAN PARAMETERS Scan Timeout Beep Duration Beep Frequency LED Duration LED Pulses Continuous Mode Keyboard Emulation Soft Trigger Scan Always On

VALUES 5000 20 2000 0 0 Disabled Disabled Enabled Disabled

BARCODE MAIN PARAMETERS Barcode Symbology Identifier Security Level Direction Redundancy

VALUES None 1 Disabled

SYMBOLOGY SPECIFIC READER PARAMETERS UPC A UPC E UPC E1 EAN 8 EAN 13 EAN Bookland

VALUES Enabled Enabled Disabled Enabled Enabled Disabled

Page 41

USE AND FUNCTIONING SYMBOLOGY SPECIFIC READER PARAMETERS Code 39 Code 39 Full ASCII Code 32 Code 39 Trioptic 2/5: Interleaved 2/5: Industrial Code 128 EAN 128 ISBT 128 Codabar MSI Code 93

3 VALUES Enabled Disabled Disabled Disabled Enabled Enabled Enabled Enabled Disabled Disabled Disabled Disabled

RFID Parameters RFID-HF MAIN PARAMETERS Tag Type I.CODE Iso-15693 Read Type Identifier The list of all the selectable tag types is found in the Technical Features tables (see par. 5.1).

3.7.4

WLAN Setup Radio Configuration

To access the menus and screen options available for terminals with WLAN PC cards installed, it is necessary to first launch the WLAN SETUP applet.

Any changes made to the configuration parameters will be maintained in permanence only by performing the Save Registry procedure as described in par. 3.7.1.

23

Page 42

Minec 4x

3

3.8

MICROSOFT® ACTIVESYNC®

Microsoft ActiveSync gives you the possibility to connect your desktop computer to your Minec 4x terminal and synchronize the information on them. Synchronization compares the data on the Minec 4x terminal with that on the desktop computer and updates both computers with the most recent information. ActiveSync is a simple solution for transfer of information between a Minec 4x terminal and a PC with an IrDA port. Files are automatically synchronized between the terminal and the PC. It is also possible to build applications that synchronize through ActiveSync. The program handles the ActiveSync communication between the PC and the terminal, a shortcut to this program is provided on the desktop. The ActiveSync communication will use the infrared (IrDA) port. With ActiveSync, it is possible to: - Back up and restore Minec 4x Terminal data. - Copy files between Minec 4x Terminal and desktop computer. - Synchronize files by selecting a synchronization mode. It is possible to constantly synchronize while connected to a desktop computer or, alternatively, synchronization can be performed only when the synchronize command is chosen. You can select which information types are synchronized and control how much data is synchronized.

By default, ActiveSync does not automatically synchronize all types of information. Use ActiveSync options to turn synchronization on and off for specific information types. NOTE

For example: Synchronize Microsoft Word and Microsoft Excel files between the Minec 4x Terminal and the desktop computer. The files will automatically be converted to the correct format. There are three different methods to make the ActiveSync connection between your PC and your terminal depending on the model as described in the following paragraphs.

24