Page 31
Communications Menu
Parity Default: Options:
Even Even, Odd, None
Allows you to choose an error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd.
Data Bits Seven
2–Menu Config.
Default: Options:
Seven, Eight
Allows you to establish the total number of bits in each character.
Stop Bits Default: Options:
One One, Two
Allows you to choose the last one or two bits in each character to indicate the end of the character.
Baud Rate Default: Options:
9600 300, 600, 1200, 2400, 4800, 9600, 19.2K
Allows you to set the number of bits transmitted per second.
VS-310 Scanner User’s Manual
2-5
Page 32
Chapter 2
Menu Configuration
Protocol
2–Menu Config.
The Protocol menu allows you to choose your communications protocol and associated output data format.
Figure 2-4 Protocol
Default Clicking the DEFAULT button will reset all options on the Protocol menu to factory defaults. You can then click Apply followed (in the pop-up dialog box) by SEND TO READER or SAVE TO READER.
Selected Protocol Default:
Point-to-Point
Options:
Point-to-Point, Point-to-Point with XON/XOFF, Polling Mode D, Multidrop, User Defined, User Defined Multidrop
Protocols define the sequence and format in which information is transferred between devices.
Point-to-Point Has no address and sends data to the host (RS-232) whenever it is available and without any request or handshake from the host.
2-6
VS-310 Scanner User’s Manual
Page 33
Protocol Point-to-Point with XON/XOFF (Transmitter On/Off) Used only with RS-232. This selection enables the host to send a single byte transmission command of start (XON) or stop (XOFF). If an XOFF has been received from the host, data will not be sent to the host until the host sends an XON. During the XOFF phase, the host is free to carry on other chores and accept data from other devices.
Polling Mode D
Multidrop Note: Readers intended to link up to a Microscan MS-5000 multidrop concentrator must be configured in standard Multidrop protocol. Note: To avoid slow or degraded performance when the VS-310 is net-worked with Microscan’s MS-5000 multidrop concentrator, the MS-5000 must have Turnaround Timeout set to 35 ms and should have Baud Rate set to 19.2 and Number of Devices set to no more than the actual number of connected devices. See MS-5000 Multidrop concentrator User’s Manual. Similar to Polling Mode D except that a unique poll address and select address are required for each multidrop device, and only one host port connection is needed for up to 50 devices. (For Multidrop poll and select characters, see Table A-E, “ASCII Table,” on page A-12.) Requires a concentrator or controller using RS-485 communications. When Multidrop is selected, the protocol characters for RES, REQ, etc. are assigned automatically. (See Table A-11, “ASCII Table with Control Characters,” on page A-12 for poll and select sequences.)
User Defined Note: A specific ASCII character must not be assigned more than once.
Used only with RS-232. User Defined is necessary when a new protocol must be defined to match a specific host protocol. ASCII characters can be assigned as an address and as protocol commands (RES, REQ, EOT, STX, ETX, ACK, NAK, From Host). In order to enable a handshaking protocol, you must manually assign values where necessary. When User Defined is selected, the displayed protocol commands match those of the previously selected protocol. User Defined is considered to be in a polled mode only if an address has been assigned. The address can be any ASCII character from Table A-11, “ASCII Table with Control Characters,” on page A-12. If null is selected as the address, the reader will not function in a polling sequence. VS-310 Scanner User’s Manual
2-7
2–Menu Config.
Like Point-to-Point, Polling Mode D requires a separate connection to the host; but unlike Point-to-Point, it requires an address and must wait for a poll from the host before sending data. When in Polling Mode D, an address of 1 is automatically displayed on the configuration screen. However, during transmission, a 1C hex poll address (FS) and a 1D hex select address (GS) are substituted for the 1.
Page 34
Chapter 2
Menu Configuration From Host, if enabled, allows the handshaking protocol to be initiated from the host, if unpolled. Default:
Disabled
Options:
Disabled, Enabled
2–Menu Config.
From Host When enabled, messages sent to the host from the VS-310 will always include the reader’s defined protocol. The status of From Host determines if messages sent to the VS-310 from the host must also include the defined protocol. If From Host is disabled, the defined protocol is not included. If From Host is enabled, the defined protocol must be included. (See “From Host,” on page 2-8 for further information.) Default:
Disabled
Options:
Disabled, Enabled
User Defined Multidrop Used when connecting to a concentrator or other device that does not match standard Multidrop protocol. Any single character (01 hex to 7E hex) in the ASCII table can be assigned as the address character. The character chosen is used as the poll character and the subsequent ASCII character becomes the select character. For example, if a ^A (01 hex) is selected as the address, ^B (02 hex) becomes the select address that the host will use in sending host select commands. (See table A-16 on page A-16.) Note: Definitions of commands in User Defined and User Defined Multidrop must be duplicated in host applications to enable poll and select sequences to execute correctly during transmission. Note: Typically, parameters in User Defined Multidrop are defined by first enabling Multidrop, then enabling User Defined Multidrop. This pre-loads Multidrop characters into the parameters. You then change individual characters to match the host or other requirements.
Preamble Preamble (enable/disable) Default:
Disabled
Options:
Disabled, Enabled (within any protocol)
Allows you to enable or disable the preamble character(s).
Preamble (definition)
2-8
Default:
CR (carriage return).
Options:
Up to two ASCII characters except NUL, <, or >.1
VS-310 Scanner User’s Manual
Page 35
Protocol If enabled, allows you to define up to two characters that can be added in front of the symbol data. For example, a carriage return.
Postamble Postamble (enable/disable) Default:
Enabled
Options:
Enabled, Disabled (within any protocol)
Allows you to enable or disable the Postamble character(s). Default:
CR LF (carriage return/line feed).
Options:
Up to two ASCII characters except NUL, <, or >.1
Allows you to define up to two characters that can be added after the symbol data. When enabled, the default CR LF causes each symbol to be displayed on its own line.
Response Timeout (character) Default:
4 (40 ms)
Options:
0 to 255 (in 10 ms increments)
Allows you to set the time the reader will wait between characters before timing out if ACK, NAK, and ETX are enabled, and a host response is expected.
Intercharacter Delay Default:
0
Options:
0 to 255 in 60 ms increments. Zero (0) causes no delay between characters.
Allows you to set the time interval in milliseconds between individual characters transmitted from the VS-310 to the host computer. A high setting will significantly slow down communications. For example, a 200 setting will result in a 2 second delay between each character that is transmitted.
Longitudinal Redundancy Check (LRC) Default:
Disabled
Options:
Disabled, Enabled
An error-checking routine that verifies the accuracy of transmissions. It is the exclusive OR of all characters in the transmitted message. The result is appended to the end of the transmitted message.
1. In the case where only one character is entered, a NUL character is selected to serve as a place holder; however, no output will result. VS-310 Scanner User’s Manual
2-9
2–Menu Config.
Postamble (definition)
Page 36
Chapter 2
Menu Configuration
Operations Menu The Operations menu allows you to set the operations parameters for the scanner. (See figure 2-5.)
2–Menu Config.
Note: Clicking the DEFAULT button will only restore those settings of the specific menu on which the button appears.
Figure 2-5 Operations Menu
Default Clicking the DEFAULT button will reset all options on the Operations menu to factory defaults. This does not affect any other menus and it does not take effect until it is saved to the scanner with the SEND TO SCANNER or the SEND/SAVE under SEND/RECV.
Triggering Mode Default: Options:
Continuous Read Continuous Read, continuous read 1, External Level, External Edge, Serial Data, Serial Data & External Edge
Allows you to establish the type of trigger event that will initiate or end the read cycle. (See “End of Read Cycle” on page 2-12.)
2-10
VS-310 Scanner User’s Manual
Page 37
Operations Menu Continuous Read Trigger input options are disabled and the scanner is always in the read cycle. Bar code data is decoded, and label information is transmitted repeatedly, as long as the label is in the read range of the scanner. When To Output options have no affect on Continuous Read. Continuous Read is useful in testing label or scanner functions. Note: If Match Code is enabled, the scanner defaults to Continuous Read 1.
Continuous Read 1
With End Of Read Cycle set to New Trigger, the scanner outputs the current label data immediately, but outputs it only once. A new label appearing at any time in the scan range will produce a new read output as long as the new label is not identical to the previous label. Note: Continuous Read 1 will default to Continuous Read when I 2 of 5 code length is enabled for greater than 30. Note: If Continuous Read 1 is enabled, Number of Labels (page 2-15) will default to one (if set for 2) and UPC Supplementals Enabled will not be available.
External Level Allows a read cycle to be initiated by a trigger signal from an object detector when an object appears within the detector’s range. The read cycle continues as long as the detector “sees” the object and ends when the object moves out of the detector’s range. Primary Trigger When an object moves into the range of the detector beam, a primary (first) trigger signal (positive or negative) is received by the scanner, initiating the read cycle.
1
Object detector
1
Secondary Trigger Object detector
When the same object moves out of the detector's beam, a second trigger signal (positive or negative) is received by the scanner, ending the read cycle.
Figure 2-6 External Level Trigger Events VS-310 Scanner User’s Manual
2-11
2–Menu Config.
Label data is immediately transmitted once every time new label data is placed in front of the scanner. With End Of Read Cycle set to Timeout and the label not changed, the scanner repeats the output at the end of each timeout period. For example, if Timeout is set to one second, the scanner outputs the label data immediately, and then repeats the output at intervals of one second, for as long as the label continues to be scanned.
Page 38
Chapter 2
Menu Configuration External Edge As with Level, a read cycle is initiated by a trigger signal from an object detector when it detects the arrival of an object (first edge). But unlike Level, the departure of an object does not end the read cycle. With Edge enabled, the read cycle ends with a new trigger caused by the arrival of a subsequent object, unless a good read or timeout occurs first. First edge When object # 1 moves in front of the detector beam, a trigger signal (positive or negative) is received by the scanner, initiating the read cycle.
2–Menu Config.
1
Object detector Subsequent edge When object # 2 moves in front of the detector's beam, a trigger signal (positive or negative) is received by the scanner, initiating a new read cycle and ending the previous read cycle (unless the previous read cycle has already been ended by a good read or timeout).
2
Object detector
Figure 2-7 External Edge Trigger Events
Serial Data The scanner accepts an ASCII character from the host or controlling device as a trigger to start a read cycle. Serial data trigger behaves the same as External Edge.
Serial Data & External Edge The scanner accepts either an external trigger or a serial ASCII command to start a read cycle.
End of Read Cycle Default: Options:
Timeout Timeout, New Trigger, Timeout & New Trigger
Allows you to choose the circumstances that will end the read cycle. The read cycle is the time during which the scanner will receive and process label data. When Triggering Mode is set to External or Serial, the trigger event initiates the read cycle. Note: When operating in Continuous Read or Continuous Read 1, the scanner is always in the read cycle.
Timeout Can end the read cycle after a specified period of time, and if no label has been read, causes a noread message, if enabled, to be transmitted.
2-12
VS-310 Scanner User’s Manual
Page 39
Operations Menu With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout ends the read cycle. With External Level enabled, the read cycle does not end until the secondary trigger occurs, and the next read cycle does not begin until the next rising edge trigger. With Continuous Read 1 enabled, a timeout initiates a new read cycle and allows the same label to be read again.
New Trigger
With either External Edge, Serial Data, or Serial Data & Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle. With External Level enabled, a secondary trigger, which occurs when the object moves out of the detector’s range, ends a read cycle. However, the next read cycle does not begin until the occurrence of the next primary trigger.
Timeout & New Trigger Ends the read cycle after a specified period of time or at the occurrence of new trigger event, and if no label has been read, causes a noread message, if enabled, to be transmitted. With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout, or an edge or serial trigger, whichever comes first, ends the read cycle. With External Level enabled, the read cycle does not end until the occurrence of a falling edge, and the next read cycle does not begin until the next rising edge trigger.
Serial Trigger Character Default: Options:
GS Any single ASCII character except NUL, an existing host command character,1 or an on-line protocol character.
Note: Serial Data (page 2-12) or Serial Data & Edge (page 2-12) must be enabled for Serial Trigger Character to take effect. “N/A” is displayed in the menu when all other triggering modes are enabled.
Allows you to define a single ASCII character as the host serial trigger character that initiates the read cycle. The serial trigger is considered an on-line host command and requires the same command format as all host serial commands (that is, to be entered within the < > brackets). 1. For example, assigning an upper case C would nullify the <C> (Enter Decode Rate Test) command. For a list of operational commands used by the scanner, see Chapter 4, “Utilities.” VS-310 Scanner User’s Manual
2-13
2–Menu Config.
Ends the read cycle at the occurrence of a new trigger event, and if no label has been read, causes a noread message, if enabled, to be transmitted at the occurrence of the new trigger event.
Page 40
Chapter 2
Menu Configuration
Good Decode Reads Default: Options:
1 1 to 31
Allows you to choose the number of good reads (from 1 to 31) required per label before a good decode output. Note: Be sure to set the value within the determined scan rate for the
2–Menu Config.
scanning setup so that the scanner is capable of scanning a label the required number of times
External Trigger Level Default: Options:
Positive Positive, Negative
Note: External Level (page 2-11), External Edge (page 2-12), or Serial
Data & Edge (page 2-12) must be enabled for External Trigger Level to take effect. “N/A” is displayed in the menu when all other triggering modes are enabled. Allows you to determine whether a positive or negative transition will initiate the read cycle. Note: If using the Microscan object detector (P/N 99-440001-03), use positive trigger polarity.
Trigger Filter Default: Options:
4 0 to 255. (Approximately 0 ms to 1.275 sec in 5 ms incs.) Multiply the number entered on the command line by 5 for time in milliseconds.
Allows you to set a trigger bounce filter duration.
Timeout (in 10 ms incs) Default: Options:
100 (one second). Corresponds to 1000 ms displayed in the menu. 0 to 65535. Divide the number entered on the command line by 100 for time in seconds.
Note: Timeout or Timeout & New Trigger under End of Read Cycle (page
2-13) must be enabled for Timeout (in 10 ms incs) to take effect. Allows you to define the duration of the timeout period.
2-14