Page 21

Do Decode Rate Test

To begin the decode rate test:

a. Position the label in front of a functioning scanner; enter the read rate test from the ESP™ terminal mode as described in “Enter Percent Test” on page 4-4. b. Observe decode rate. c. Check depth-of-field (minimum/maximum range) by moving the label closer and further relative to the scanner and noting the points where the decode rates fall below a level acceptable to your application. d. Ideally, the label used in your application should pass through or near the center of the depth-of-field.

33 Decodes/Sec 0123456 33 Decodes/Sec 0123456 33 Decodes/Sec 0123456 33 Decodes/Sec 0123456 33 Decodes/Sec 0123456

Decode Rate per Second Label Data e. Repeat steps a through c for other labels used in your application. If the decode rate is acceptable, go to Step 11, “Install Scanner,” on page 1-13. If the decode rate is unacceptable, go to Step 10, “Adjust Other Scanning Parameters,” on page 1-12. Note: If, after making adjustments, the read range or another parameter used in the number of scans formula has changed, recalculate the number of scans (Step 3, “Calculate Number of Scans,” on page 1-4). Note: Variations between labels are common. For this reason, the greater number of sample labels tested, the more likely you are to achieve optimum decode rates.

VS-310 Scanner User’s Manual

1-11

1–Setup and Inst.

9 Do Decode Rate Test

Page 22

1–Setup and Inst.

Chapter 1

Setup and Installation

10 Adjust Other Scanning Parameters

This section lists various adjustments that may improve decode rates. After changing any of the parameters described in this section, a. If applicable, recalculate the number of scans (Step 3, “Calculate Number of Scans,” on page 1-4). b. Repeat Step 9, “Do Decode Rate Test,” on page 1-11. c. Compare the new decode rate results with those obtained before changes were made.

Range Adjusting the label’s range, if possible, is one of the quickest and most effective ways to improve decode rates.

Scan Width Increasing scan width will increase the number of scans in a picket fence oriented application. Scan width is linked with scan range and changing one will usually require a change in the other.

Label Speed Applies to both picket fence and ladder oriented labels. If your application allows it, label speed (the time in seconds that a label is fully within the scan width of the scanner) is an effective way to alter the number of scans.

Label Dimensions, Label Density, and Label Ratio Not usually an option in most applications, but changes to label parameters can affect number-of-scan calculations and possibly decode rates. If your application allows it, shortening the length of a picket fence label means the label will be in the scan range longer and hence receive a greater number of scans. Increasing bar height of a label in ladder orientation means the label will receive more scans. Changing label density and/or bar code ratio is another way ranges, decode rates, etc. can be altered.

1-12

VS-310 Scanner User’s Manual

Page 23

Install Scanner

1–Setup and Inst.

11 Install Scanner

The VS-310 scanner can be top or bottom mounted as per dimensions shown in figure 1-15.

2.29" 5.82 cm

To permanently mount the scanner: a. Position the scanner in a place devoid of sunlight, bright lights, or laser light from other sources. b. Drill two 0.128 inch (3.25 mm) diameter holes 2.29” (5.82 cm) apart as per figure 1-15.

1.10" 2.79 cm

M4 threaded mounting holes (2 places)

0.3"

Bottom

2.15" 5.46 cm

.762 cm Not threaded P

D

TM

1.10" 2.79 cm

Caution: Maximum pene- tration depth of screws is 0.200 inch (5.08 mm).

M4 threaded mounting holes (2 places)

Top

Figure 1-15 Mounting Holes and Dimensions (not to scale)

VS-310 Scanner User’s Manual

1-13

Page 24

1–Setup and Inst.

Chapter 1

Setup and Installation

12 Position Object Detector

If you are not using an object detector, ignore this step. In a typical operation, a scanner will wait for bar code data only during a triggered read cycle. A read cycle is initiated by a “trigger” that can be in the form of a serial command from the host (internal trigger) or a signal from an object detector (external trigger). When an object detector is used, it is set up so that its beam will bounce off the approaching object and the resulting pulse will be sent to the scanner to begin the read cycle. Typically, a detector is positioned so that it will detect the presence of an object before the object’s label can be scanned by the scanner. An object detector is mounted in almost any position relative to the object as long as (1) the object passes within range of the detector and (2) direct or reflected light from the detector does not interfere with the scanner’s reception. As the item continues to move down the line, its label moves into the scanner beam and is read by the scanner.

Label Detector Scan beam Direction of label travel Scanner

Figure 1-16 Detector Orientation

Figure 1-16 shows a picket fence label being scanned with the detector and scanner at right angles to each other.

1-14

VS-310 Scanner User’s Manual

Page 25

Operational Tips

Do: • Check inputs (label speed, length, height, etc.) to ensure the desired number of scans per label. • Avoid excessive tilt, pitch, and skew of the bar code label. • Check the label for readability by doing a decode rate test. If there is any question about the label's readability, contact your Microscan representative. • After changing any parameter that might affect decode rate, repeat decode rate test. • Clean the scanner window with a clean, dry Q-tip or cotton cloth on a regular basis. Do Not: • Aim the scanner into direct light or sunlight. • Aim the scanner into an external object detector or other light-emitting device. • Obstruct the scanner window with mounting hardware or other objects. • Connect chassis of scanner and host to different ground potentials (see appendix H on page A-19). • Operate the scanner in excessive temperature environments (see “ENVIRONMENT” on page A-2).

VS-310 Scanner User’s Manual

1-15

1–Setup and Inst.

Operational Tips

Page 26

Setup and Installation

1–Setup and Inst.

Chapter 1

1-16

VS-310 Scanner User’s Manual

Page 27

Chapter

2

Menu Configuration Using ESP™ to Configure the Scanner................................................... 2-2 Communications Menu............................................................................ 2-4 Protocol ................................................................................................... 2-6 Operations Menu ................................................................................... 2-10 Code Types Menu ................................................................................. 2-16 Scanner Outputs Menu.......................................................................... 2-21

This chapter tells how to configure the VS-310 scanner using the ESP™ program on a Windows based (Windows 3.1™ or Windows 95™) computer.1 The ESP™ program can be thought of as two programs: one for use in configuration, the other for use in testing and operations. Configuration is covered in this chapter; testing and operations are covered in Chapter 4. Microscan’s ESP™ will allow the user to quickly configure the VS-310 scanner and save multiple configuration files to the host or setup computer which in turn can be used to archive or download settings to other scanners. After changes are made in the configuration menus, they can be downloaded in total to the scanner and the current settings will be posted in a status window. It is important to note that configuration settings can be saved in two distinct ways: to the scanner or to the host computer. Note: See Step 5, “Install ESP™,” on page 1-7 and Chapter 4, “Utilities,” for testing and operational uses of the ESP™ program.

1. Before installing the program you should have a working acquaintance with the Windows® platform. See Microsoft Windows® literature and Help files for additional information. VS-310 Scanner User’s Manual

2-1

2–Menu Config.

Chapter Contents

Page 28

Chapter 2

Menu Configuration

Using ESP™ to Configure the Scanner Figure 2-1, “Configuration Setup File,” shows the window you will see when you launch the Easy Setup Program. Pull down menus

2–Menu Config.

Toolbar An “Untitled...” file loads with the original factory default settings Access configuration menu changes here. Emulation window displays echoed commands and data Also titled “Current Menu/Scanner Settings” following a save or upload You can also access the configuration menus by double clicking any item here. Allows you to perform tests and access operational information

Allows you to download/upload between the scanner and the host Figure 2-1 Configuration Setup File

To access the configuration menus, press the MENU button. If using a mouse, single click on menu items and enter text as appropriate. If using the keyboard, use the Alt key plus underlined letters and the tab key to move to the desired field, use arrow keys or the space bar to scroll through selections, and the Enter key to accept changes.

2-2

VS-310 Scanner User’s Manual

Page 29

Using ESP™ to Configure the Scanner Saving Settings to the Scanner You can access the SEND/RECV box by clicking it directly from the Current Main menu, or after making changes from within any of the configuration menus, clicking Apply. (Clicking OK on these menu pages will only update the items in the Current Settings window.) From within the SEND/RECV box, click SEND TO SCANNER to initialize and reset counters only, or SEND/ SAVE to initialize, reset counters, and save these settings to the scanner’s nonvolatile memory. (See figure 2-1 on page 2-2.)

2–Menu Config.

Uploading Settings To update current settings from the scanner (from RAM), click SEND/RECV and then RECEIVE FROM SCANNER. Note: If receiving scan data and you are in

Continuous Read, labels being scanned may interfere with your data request (figure 2-2).

Figure 2-2 Upload Error

Saving Settings to the Host Computer When saving a file by clicking SAVE AS (or SAVE) from the File pull-down menu, the settings are saved only on the computer’s hard drive or other storage medium. This is particularly useful for saving special sets of settings that you may want to recall later and use for a different application.

Creating a New Configuration File To create a new file of configuration settings, first be sure you’ve saved the current configuration file to the computer’s hard drive or other storage device. Next pull down the File menu in the ESP™ and click New. A new Untitled window will open with a listing of the factory default settings. Change these settings to suit your requirements and save this file to the computer’s hard drive under a new name. These settings can also be downloaded to the scanner at any time under a name of your choice.

Restoring Factory Default Settings Note: Be certain that you’ve saved any other configuration files to the host computer that you may want to reload later. Default settings can be reset for individual menus pages or for all menus at once. To restore factory defaults for individual menus (Communications, Operations, Code Types, or Scanner Settings), click the DEFAULT button on the specific menu. To restore factory defaults for ALL settings in the scanner, click the DEFAULT button on the Reset page of the Utilities menu, or click New in the File pulldown menu.

VS-310 Scanner User’s Manual

2-3

Page 30

Chapter 2

Menu Configuration

Communications Menu

2–Menu Config.

The Communications menu allows you to set the communication protocols of the scanner. (See figure 2-3.).

Figure 2-3 Communications Menu Structure Note: When you make and save menu communications changes to the scanner, those changes will automatically be matched in the Serial Port configuration.

Default Clicking the DEFAULT button will reset all options on the Communications menu to factory defaults. This does not affect any other menus and it does not take effect until it is saved to the scanner with the SEND TO SCANNER or the SEND/SAVE buttons under SEND/RECV.

2-4