The text of a manual · part 2 of 11
VS-310 Scanner User's Manual, pages 11 to 20
Pages 11 to 20 of 108
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan VS-310
Page 11
1
Setup and Installation
Chapter Contents Step 1 - Plan Scanning System 1-2 Step 2 - Verify Read Range and Scan Width ...................................... 1-3 Step 3 - Calculate Number of Scans ................................................... 1-4 Step 4 - Attach Cabling ....................................................................... 1-6 Step 5 - Install ESP™ ......................................................................... 1-7 Step 6 - Establish Communications .................................................... 1-8 Step 7 - Configure Scanner ................................................................ 1-9 Step 8 - Position Scanner and Label ................................................ 1-10 Step 9 - Do Decode Rate Test .......................................................... 1-11 Step 10 - Adjust Other Scanning Parameters ................................... 1-12 Step 11 - Install Scanner 1-13 Step 12 - Position Object Detector .................................................... 1-14 Operational Tips................................................................................. 1-15
This chapter provides step-by-step instructions for setting up and installing the VS-310 scanner. Note: Bar code labels should meet minimum ANSI (American National
Standards Institute) standards as specified in ANSI Bar Code Print Quality Guideline, X3.182-1990.
VS-310 Scanner User’s Manual
1-1
1–Setup and Inst.
Chapter
Page 12
1–Setup and Inst.
Chapter 1
Setup and Installation
1 Plan Scanning System
Before installing the VS-310 scanner sketch out a diagram of your scanning system (RS-232 or RS-422/485?), showing equipment, connector and cable types (custom or Microscan cables), and cable lengths (see “Attach Cabling” on page 1-6). Figure 1-1 shows an RS-232 scanning system setup without an interface box. Figure 1-2 shows a system with an IB-105 interface box (see “Connectivity with the IB-105” on page A-6).
Object detector
Host
To power supply
VS-310 (RS-232)
Figure 1-1 System Diagram (without interface box)
Object detector
IB-10 5 Junction box
VS-310
Host
To power supply
For RS-232, use Cable 61-130014-03 or 61-130019 For RS-422/485, use 61-130024 Figure 1-2 System Diagram (with interface box)
1-2
VS-310 Scanner User’s Manual
Page 13
Verify Read Range and Scan Width
Table 1-1 shows readable ranges and scan widths for specific bar code density (narrow-bar-width) types. Use this table as a reference to verify that the planned range for the label falls within one of the listed ranges. Scan width is that portion of the scan line in which a label can be read. For ladder oriented labels, scan width must only be wide enough to fully cover the label length, including quiet zones. With picket fence oriented labels, scan width is a factor in determining the time in which the label can be read (see “Calculate Number of Scans” on page 1-4). Table 1-1 Read Ranges and Scan Widths
Narrow-BarWidth
Read Rangea
Scan Width Data
HIGH DENSITY (60 SPS) .005" (0.15 mm)
2.25" to 3.0" (5.72 to 7.62 cm)
3.15" @ 2.75" (8.0 @ 6.99 cm)
.0075" (0.191 mm)
2.0" to 3.5" (5.08 to 11.43 cm)
4.0" @ 2.75" (10.16 @ 6.99 cm)
LOW DENSITY (100 SPS) .0075" (0.191 mm)
2.5" to 4.5" (6.35 to 11.43 cm)
4.0" @ 2.75" (10.16 @ 6.99 cm)
.010" (0.254 mm)
2.0" to 5.5" (5.08 to 13.97 cm)
4.0" @ 2.75" (10.16 @ 6.99 cm)
.015" (0.381 mm)
2.0" to 6.5" (5.08 to 16.51 cm)
4.0" @ 2.75" (10.16 @ 6.99 cm)
.020" (0.508 mm)
2.0" to 7.25" (5.08 to 18.42 cm)
4.0" @ 2.75" (10.16 @ 6.99 cm)
a. Read range is the distance from the front of the scanner to the label in which the label can be reliably read. The distance between the minimum and maximum ranges is the depth of field. Note: Optimum decode rates can be expected at the center of the depth of field (halfway between minimum and maximum read range) for a given bar code density. For information on label orientation, see Appendix G, “Orientation.”
VS-310 Scanner User’s Manual
1-3
1–Setup and Inst.
2 Verify Read Range and Scan Width
Page 14
1–Setup and Inst.
Chapter 1
Setup and Installation
3 Calculate Number of Scans
To ensure reliable scanning, we recommend a minimum of five scans per label. Use the formulas below to calculate the number of scans that the label will receive. For definitions of terms, see inset on page 1-5.1 If the number of scans derived from one of these calculations is less than the minimum for the application, plug in the minimum number of scans and solve for another parameter that might be changed, such as label speed or scans per second. Note: Scans per second is 100 for low density option and 60 for high density option.
Ladder Calculation LH ------- × SR – 2 = number of complete scans LS
Where LH = Label Height, LS = Label Speed, and SR = Scan Rate. Direction of label travel
LH = 1 inch LS = 5 inches per second SR = 100 scans per second
Scan Line
1-- × ( 100 ) – 2 = 18 complete scans 5
Picket Fence Calculation
Figure 1-3 Ladder Orientation
SW – LL ) (------------------------× SR – 2 = number of complete scans
LS Where SW = Scan Width, LL = Label Length,
Direction of label travel
LS = Label Speed and SR = Scan Rate Scan Line
SR = 100 scans per second 4 – 2) (---------------× 100 – 2 = 98 complete scans 2
Figure 1-4 Picket Fence Orientation
1. The -2 component is added to allow for AGC acquisition and for incomplete first or last scans.
1-4
VS-310 Scanner User’s Manual
Page 15
Calculate Number of Scans
1–Setup and Inst.
Angled Picket Fence Calculation Direction of label travel
The number of complete scans for angled picket fence is calculated the same as that for picket fence, with the exception that the scan width is shortened in proportion to scan tilt.
Scan Line
Figure 1-5 Angled Picket Fence Orientation
• Scan Rate (SR) is the number of scans per second that a given scanner is capable of emitting. • Scan Width (SW) (picket fence formula only) is the width across the scan beam, at a given distance from the scanner, in which a label can be read. • Label Speed (LS) is the distance per second that a label moves as it travels through the scan lines. • Label Length (LL) (picket fence formula only) is the length of the longest printed label to be read plus the length of the quiet zones (figure 1-6).
Label Length Label height
Quiet zones
Figure 1-6 Label Dimensions
• Label Height (LH) (ladder formula only) is a measurement of the height of individual bars (figure 1-6). Note: The formulas given here solve for the predicted number of scans;
you may also assign a value for number of scans (3 or more) and to solve for other parameters that might be changed, such as label speed, etc.
VS-310 Scanner User’s Manual
1-5
Page 16
1–Setup and Inst.
Chapter 1
Setup and Installation
4 Attach Cabling
If your VS-310 is an RS-232 option (see table A-4 on page A-3) refer to the “RS-232 Options” column in table 1-2. If it’s an RS-422/485 option, refer to the “RS-422/485 Options” column. If you are making up a custom cable, see “Mating Connector” on page A-4 for instructions on assembling the mating connector kit (Microscan P/N 98-200021-01) included with the VS-310 scanner. You can also order a Microscan 9-pin to 15-pin cable as described in Appendix C, “Accessory Cables,” on page A-5 for connection to the IB-105 interface box or other device. See also “IB-105 Connectors and Pinouts” on page A-10. Table 1-2 9-pin, mini-Din Connector
Pin No.
RS-232 Options
1 2 3 4 5 6 7 8 9 Shield
+5 VCC Output-1a RS-232 RXD Signal Ground RS-232 TXD Trigger input Default pin Output-2a RS-485 Driver Enable Chassis Groundb
RS-422/485 Options +5 VCC Output-1a TX + Signal Ground TX – Trigger input Default pin RX + RX – Chassis Ground a. can sink 3.5 mA or source 60 µA b. Chassis g round and signal ground are internally connected through a zero ohm resistor.
9 6
3 2
Figure 1-7 9-pin mini-Din Connector
1-6
VS-310 Scanner User’s Manual
7
1
Page 17
Install ESP™
To install the ESP™, a. Make a backup copy of the ESP™ disk(s). b. Start the setup.exe program and follow the on-screen directions to install ESP™. You will see a screen similar to figure 1-8.
Pull-down menus
Toolbar Serial port Auto baud
Settings window
Auto baud status
Figure 1-8 Basic ESP™ Menu c. Proceed to Step 6. Note: ESP™ menu commands can be carried out by mouse or by keystroke by pressing the Alt key and typing in the appropriate underlined letter(s) of the menu or command. VS-310 Scanner User’s Manual
1-7
1–Setup and Inst.
5 Install ESP™
Page 18
1–Setup and Inst.
Chapter 1
Setup and Installation
6 Establish Communications To establish communications, a. Select Serial Port and Configure from the pull-down menus. b. Make your port selection from Serial Port options COM 1 through COM 4 (usually COM 2 for desktops and COM 1 for laptops). c. Click SEND/RECV button on the main menu to see the transfer dialog (figure 1-9). d. If you want to copy the settings from your scanner to the host computer, click SEND TO SCANNER.
Figure 1-9 Scanner Configuration Transfer e. To transfer your current host file settings to the scanner, click RECEIVE FROM SCANNER. If Match Serial Port to Menu Settings is checked, the current menu settings as listed in the settings window will be copied to the host’s serial port as well as sent to the scanner. The default settings for the scanner are 9600 baud, Even Parity, 7 Data Bits, and 1 Stop Bits. f. If after some delay you get an “Upload from scanner has timed out!” message, click the Auto Baud button (figure 1-8) or select Auto Baud from Serial Port pull down menu. Allow some time for the auto baud routine to test most of the combinations. You can Figure 1-10 Error Messages watch this at the bottom of the dialog box. Once it has found it, it will change the host’s settings to match the scanner’s. If Upload Status shows Passed in all categories (as shown in figure1-11), then go to Step 7, “Configure Scanner,” on page 1-9. Note: Auto Baud does not test for Com ports. This requires manual entry.
1-8
Figure 1-11 Upload Status
VS-310 Scanner User’s Manual
Page 19
Configure Scanner
Settings for Communications, Operations, Code Types, and Scanner Output are loaded into the scanner’s RAM from a Windows-based configuration program by menu (see Chapter 2, “Configuration Setup File”) or by serial command (Chapter 3, “Serial Configuration”) from an ASCII terminal. For explanations of configuration settings, see Chapter 2, “Menu Configuration.” For a list of serial configuration commands, see Chapter 3, “Serial Configuration.”
Figure 1-12 ESP™ Configuration Menus Note: When you save communications changes to the scanner, serial port settings are automatically matched. Note: You can check your scanner’s settings at any time by clicking
SEND/RECV and RECEIVE FROM SCANNER to upload the scanners current settings.
VS-310 Scanner User’s Manual
1-9
1–Setup and Inst.
7 Configure Scanner
Page 20
1–Setup and Inst.
Chapter 1
Setup and Installation
8 Position Scanner and Label
Before testing the decode rate, you will need to position the scanner and label in a manner that matches as nearly as possible the actual conditions of your application.
Bar code label a. Position the scanner and label, taking care to avoid excessive tilt, skew, or pitch.1
Skew axis Tilt axis
Scanner + Pitch axis b. Pitch label (or scanner) slightly up (at least 2°) or down (at least 7°) as shown in figure 1-14 to avoid specular reflection, the return of direct, non-diffused light.2 Note: If this label were moving from left to right (or vice versa), the orientation of the label, relative to the scan Figure 1-13 Tilt, Skew, and Pitch Axes beam, would be “picket fence;” if the label were moving from top to bottom (or vice versa), the orientation of the label, relative to the scan beam, would be “ladder.” Scan line
For more information, see Appendix G, “Orientation,” on page A-17. Avoid this zone
Scanner
Specular 8.9°zone reflection -7° to +2°
Figure 1-14 Specular Reflection Zone
1. Maximum tilt is determined by label characteristics and number of scans required. Maximum skew is ±40°; maximum pitch is ±50°. 2. The specular reflection zone is a narrow arc on the label’s pitch axis -7° to +2° relative to the scanner in which direct reflected light from the label can distort the scanner’s ability to distinguish bars from spaces.
1-10
VS-310 Scanner User’s Manual