Page 41
Operations Menu
Match Code Default: Options:
Disabled Disabled, Enabled
Note: Match Code will not function when I 2 of 5 code length is enabled for greater than 30. Note: A triggered mode (page 2-14 to page 2-12) must be enabled for
Match Code to take effect.
Allows you to enter a master label into the scanner's memory to be compared with subsequently scanned labels. (See “Master Label” on page 4-9.)
Number of Labels Default: Options:
1 1 to 2
Note: If Number of Labels is set to 2 while Match Code or Continuous
Read 1 is enabled, Number of Labels will default back to one. Allows you to choose the number of different labels that will be read in a single trigger event. The following conditions apply: 1. Each label must have different label data to be read. 2. The maximum number of characters that can be transmitted in any one label, or in both labels if 2 is enabled, is 64, excluding preamble, postamble, and all spaces and commas. 3. When 2 is enabled, a noread message for either label will be posted at the end of the full data string. 4. If more than one label is within the scan beam at the same time, label data may not be displayed in the order of appearance.
Multilabel Separator Default: Options:
, (comma) Any ASCII character except NUL, <, or >.
Allows you to choose the separator character to be inserted between each label.
VS-310 Scanner User’s Manual
2-15
2–Menu Config.
Note: If Match Code is enabled, Number of Labels will default to 1 (if set for 2) and UPC Supplementals Enabled will not be available.
Page 42
Chapter 2
Menu Configuration
Code Types Menu
2–Menu Config.
The Code Types menu allows you to choose among five bar code types and define their parameters. (See figure 2-8.)
Figure 2-8 Code Types Menu
Default Clicking the DEFAULT button will reset all options on the Code Types menu to factory defaults. This does not affect any other menus and it does not take effect until it is saved to the scanner with the SEND TO SCANNER or the SEND/SAVE under SEND/RECV.
Code 39 Default: Options:
Enabled Enabled, Disabled
Check Digit Default: Disabled Options: Disabled, Enabled Code 39 is self-checking and does not normally require a check digit. However, for additional data integrity, a Modulus 43 check digit can be added to the bar code message. With Check Digit and an External or Serial trigger option enabled (see “External Trigger Level” on page 2-14), an invalid
2-16
VS-310 Scanner User’s Manual
Page 43
Code Types Menu check digit calculation will cause a noread message to be transmitted at the end of the read cycle.
Check Digit Output Default: Disabled Options: Disabled, Enabled When enabled, the check digit character is sent along with the label data. When disabled, label data is sent without the check digit.
Allows the scanner to read labels with gaps between bar code characters exceeding three times the narrow element width.
Fixed Code Length Default: Disabled Options: Disabled, Enabled Used to increase data integrity by ensuring that only one label length will be accepted.
Code Length Default: 10 Options: 1 to 31 Allows you to specify the exact number of characters that the scanner will recognize (this does not include start and stop). The scanner will ignore any code not having the specified length.
Codabar Default: Options:
Disabled Disabled, Enabled
Large Intercharacter Gap Default: Disabled Options: Disabled, Enabled Allows the scanner to read labels with gaps between bar code characters exceeding three times the narrow element width.
Check Digit Default: Disabled Options: Disabled, Modulus 16, NW 7, Both Allows you to choose the type of checksum system Codabar will use.
VS-310 Scanner User’s Manual
2-17
2–Menu Config.
Large Intercharacter Gap Default: Disabled Options: Disabled, Enabled
Page 44
Chapter 2
Menu Configuration Check Digit Output Default: Disabled Options: Disabled, Enabled When enabled, the check digit character is sent along with the label data. When disabled, label data is sent without the check digit.
2–Menu Config.
Start & Stop Match Default: Enabled Options: Enabled, Disabled Requires the Codabar start and stop characters (a, b, c, or d) to match before a valid read can occur.
Start & Stop Output Default: Enabled Options: Enabled, Disabled Allows the start and stop characters to be transmitted with bar code data.
Fixed Code Length Default: Disabled Options: Disabled, Enabled Increases data integrity by ensuring that only label length will be accepted.
Code Length Default: 10 Options: 1 to 31 (Includes check digit but not start and stop characters) Allows you to specify the exact number of characters that the scanner will recognize. The scanner will ignore any code not having the specified length.
Interleaved 2 of 5 Default: Options:
Disabled Disabled, Enabled
Because I 2 of 5 is a continuous code, it is prone to substitution errors. Hence, a code length must be defined and a bar code label containing an even number of digits must be used. It is also recommended that a Modulus 10 check digit be used to ensure the best possible data integrity.
Check Digit Default: Disabled Options: Disabled, Enabled I 2 of 5 uses a Modulus 10 check digit.
2-18
VS-310 Scanner User’s Manual
Page 45
Code Types Menu Check Digit Output Default: Disabled Options: Disabled, Enabled When enabled, the check digit character is sent along with the label data. When disabled, label data is sent without the check digit.
the next lower number.
With I 2 of 5, two code lengths can be defined. When using only one label length in an application, we recommend setting Code Length #2 to 0 to ensure data integrity. If a check digit is used, it must be included in the code length count. Note: If Code Length of #1 is greater than 30, then Continuous Read 1 defaults to Continuous Read, Match Code is disabled, and Number of Labels defaults to 1.
Code Length #2 Default: 6 Options: 0 to 30, even. If you enter an odd number the scanner will use the next lower number.
If using a second label, you may also specify a zero or any even code length from 2 to 30. If not using a second label, set Code Length #2 to 0 to ensure data integrity.
Code 93 Default: Options:
Disabled Disabled, Enabled
Fixed Code Length Default: Disabled Options: Disabled, Enabled Allows you to increase data integrity by ensuring that only one label length will be accepted.
Code Length Default: 10 Options: 1 to 31 Allows you to specify the exact number of characters that the scanner will recognize (this does not include start and stop). The scanner will ignore any code not having the specified length. VS-310 Scanner User’s Manual
2-19
2–Menu Config.
Code Length #1 Default: 10 Options: 2 to 64, even. If you enter an odd number the scanner will use
Page 46
Chapter 2
Menu Configuration
Code 128 Default: Options:
Disabled Disabled, Enabled
Fixed Code Length Default: Disabled Options: Disabled, Enabled
2–Menu Config.
Allows you to increase data integrity by ensuring that only one label length will be accepted.
Code Length Default: 10 Options: 1 to 31 Note: Fixed Code Length must be enabled for Code Length to take effect.
Allows you to specify the exact number of characters that the scanner will recognize. The scanner will ignore any code not having the specified length.
Autodiscriminate Default: Options:
Disabled Disabled, Enabled
Enables all code types simultaneously.
Narrow Margins Default: Options:
Disabled Disabled, Enabled
Allows the scanner to read bar codes with quiet zones less than 10 times the narrow-bar-width. Quiet zone is a term used to describe the minimum space at the leading and trailing ends of a label. Each quiet zone can be as small as five times the narrow bar element when Narrow Margins is enabled.
2-20
VS-310 Scanner User’s Manual
Page 47
Scanner Outputs Menu
Scanner Outputs Menu The Scanner Outputs menu allows you to configure the scanner’s output.
2–Menu Config.
Figure 2-9 Scanner Outputs Menu Note: Bar code output data and noread messages are transmitted on pin
5 under conditions set principally in Bar Code Output. Relay pulses are transmitted via pins 2 and 8 (Relay-1 and Relay-2 respectively) and individually configured under conditions set in Relay-1 and Relay-2.
Default Clicking the DEFAULT button will reset all options on the Scanner Outputs menu to factory defaults. This does not affect any other menus and it does not take effect until it is saved to the scanner with the SEND TO SCANNER or the SEND/SAVE under SEND/RECV.
Bar Code Output Default: Options:
On Good On Good, Disabled, Match, Mismatch
If Bar Code Output is set to Match or Mismatch, label data will not output unless Match Code (page 2-16) is enabled and a master label is downloaded into memory. Allows you to choose the conditions that will send label data (or noread messages) to the host computer. VS-310 Scanner User’s Manual
2-21
Page 48
Chapter 2
Menu Configuration Disabled The scanner will not output either label data or noread messages to the serial port.
Match (with Match Code enabled) The scanner will output when the label data information matches the master label. However, if Match Code is disabled it will output on any good read.
Mismatch (with Match Code enabled)
2–Menu Config.
The scanner will output when the label data information does not match the master label. However, if Match Code is disabled it will output on any good read.
When to Output (bar code data) Default: Options:
As Soon As Possible As Soon As Possible, End of Read Cycle
Allows you to choose when bar code data is sent to the host computer.
As Soon As Possible Causes bar code data (good reads) to be transmitted immediately upon a good decode.
End of Read Cycle Causes bar code data output to be delayed until the end of the read cycle.
Beeper Status Default: Options:
On Good On Good, On Noread, Disabled
A beep is emitted either after each good read of a bar code label or after each noread.
Beeper Speed Default: Options:
Fast Fast, Slow
Allows you to control the duration of the sound emitted by the beeper.
Noread Message Default: Options:
NOREAD Up to seven ASCII characters (except NUL).
Allows you to define any combination of ASCII characters (except NUL) up to seven characters as the noread message. When enabled, the noread message will be transmitted to the host at a timeout or the end of a read cycle if the bar code label has not been decoded.
2-22
VS-310 Scanner User’s Manual
Page 49
Scanner Outputs Menu
Enable Laser On/Off Default: Options:
Disabled Disabled, Enabled
Note: A serial or external trigger (see “External Trigger Level,” on page
2-14) must be enabled for Laser On/Off to take effect. When enabled, the laser is ON only during the read cycle. When disabled, the laser operates continuously. <I> (Disable Laser Scanning) operational commands on page 4-6.
Enable Noread Default: Options:
Enabled Enabled, Disabled
Note: If Noread Output is enabled, the noread message will only output if
Bar Code Output (page 2-21) is also enabled.
Allows you to enable or disable the noread message.
Relay 1 and Relay 2 Relay 1 and Relay 2 can allow simultaneous output on pins 2 and 8 respectively under individually programmed conditions. The following parameters (Output On, Polarity, and Pulse Width) are individually configured in ESP™, but described only once here. Note: Relay 2 is not available if using an RS-422/485 version.
Polarity Default: Options:
Negative Negative, Positive
Allows you to choose between positive and negative output signals for the relay output pin that is enabled.
Pulse Width (in 10 ms incs) Default: Options:
5 (.05 seconds). Corresponds to 50 ms displayed in the menu. 0 to 255 (0 to 2.55 seconds). Divide the number entered on the command line by 100 for time in seconds.
Allows you to set the duration of the good match/noread output signals at the relay output pin that is enabled.
VS-310 Scanner User’s Manual
2-23
2–Menu Config.
Note: Laser On/Off does not relate to the <H> (Enable Laser Scanning) or
Page 50
Chapter 2
Menu Configuration
Output On Mismatch or Noread
Default: Options:
Mismatch or Noread, Match, Mismatch, Noread
Allows you to set the conditions that will output a relay pulse. To see the options for enabling Match Code and downloading a master label into memory. (See “Master Label,” on page 4-9.)
Mismatch or Noread
2–Menu Config.
Sends a pulse to the relay output pin(s) when the following conditions are met: 1. Match Code is disabled and a noread occurs; or 2. Match Code is enabled (page 2-15), and ANY of the following is true: a. a label is decoded and does not match the master label, b. c.
there is no master label in memory (page 4-9), or a noread occurs.
Noread Sends a pulse to the relay output pin(s) when the label’s data is not decoded before the end of the read cycle regardless of the status of Match Code.
Match Sends a pulse to the relay output pin(s) if the following conditions are met: 1. Match Code is disabled and a label is decoded; or 2. Match Code is enabled (page 2-15) and ALL of the following are true: a. b.
A master label is downloaded into memory (page 4-9), A label is decoded, and c.
The decoded label matches the master label
Mismatch Sends a pulse to the relay output pin(s) that is enabled if ALL of the following conditions are met: 1. Match Code is enabled (page 2-15). 2. A label is decoded. 3. The decoded label does not match the master label or there is no master label in memory (page 4-9).
2-24