Page 81

Verification

Grid Non-Uniformity Measures cell deviation from the theoretical or “ideal” grid intersections as determined by the reference decode algorithm. When enabled, includes the symbol’s Grid Non-Uniformity grade and/or value in the verification report.

Modulation Assesses the reflectance uniformity of the symbol’s light and dark elements. When enabled, includes the symbol’s Modulation Grade in the verification report.

Quadrus Verifier User’s Manual

3-37

Page 82

ISO/IEC 15415 Output by ESP

Unused ECC Determines the amount of error correction capacity that was used to decode the symbol, and indicates the remaining amount of available error correction. When enabled, includes the symbol’s Unused Error Correction grade and/or value in the verification report.

Print Growth Determines the degree to which a symbol is overprinted or underprinted. When enabled, includes the symbol’s Print Growth Value in the verification report.

3-38

Quadrus Verifier User’s Manual

Page 83

Verification

Pixels Per Element Counts the number of pixels in each symbol element. The higher the Pixels Per Element count, the more readable the symbol. When enabled, includes the symbol’s Pixels Per Element Value in the verification report.

Quadrus Verifier User’s Manual

3-39

Page 84

AIM DPM Verification Setup

AIM DPM Verification Setup This command allows the user to fine-tune lighting and camera settings to comply with AIM DPM’s optical requirements for 2D verification.

Minimum Element Size Definition:

The minimum expected element size of the candidate symbol in 1/1000 of an inch, or the symbol’s mil size. The minimum and maximum element size values define the range for calibration. Note: A larger minimum-to-maximum range of element size may slow down the calibration phase of the symbol grading process. Once the candidate symbol is identified, the AIM DPM procedure will use and report the actual aperture size used for verification.

Serial Cmd:

<K532,minimum element size,maximum element size,wavelength,lighting>

Default:

10

Options:

7 to 50

Maximum Element Size Definition:

The maximum expected element size of the candidate symbol in 1/1000 of an inch, or the symbol’s mil size. The minimum and maximum element size values define the range for calibration. Note: A larger minimum-to-maximum range of element size may slow down the calibration phase of the symbol grading process. Once the candidate symbol is identified, the AIM DPM procedure will use and report the actual aperture size used for verification.

Serial Cmd:

<K532,minimum element size,maximum element size,wavelength,lighting>

Default:

15

Options:

7 to 50

Wavelength Definition:

The wavelength of illumination in the lighting environment used for verification. Important: The operator must ensure that this setting matches that of the illumination source being used.

Serial Cmd:

<K532,minimum element size,maximum element size,wavelength,lighting>

Default:

660

Options:

400 to 700

3-40

Quadrus Verifier User’s Manual

Page 85

Verification

Lighting Definition:

A string of ASCII characters that represents the angle and configuration of illumination used in the verification environment. Important: For reliable Direct Part Mark verification results, Microscan recommends setting the Lighting parameter to 90. This is because diffuse perpendicular (or “on axis/bright field”) illumination - in which the symbol plane is parallel to the plane of the Verifier’s sensor and the symbol is uniformly illuminated at a 90° angle of incidence - is most effective for reading Direct Part Marks. Note: Details about other lighting configurations and their corresponding ASCII representations can be found in AIM Global’s “Direct Part Mark (DPM) Quality Guideline”, available at www.aimglobal.org.

Serial Cmd:

<K532,minimum element size,maximum element size,wavelength,lighting>

Default:

45Q

Options:

Any ASCII string up to 15 characters

Quadrus Verifier User’s Manual

3-41

Page 86

AIM DPM Verification Setup by ESP

AIM DPM Verification Setup by ESP AIM DPM Verification Setup allows the user to fine-tune lighting and camera settings to comply with AIM DPM’s optical requirements for 2D verification.

Minimum Element Size Minimum Element Size is the minimum expected element size of the candidate symbol in 1/1000 of an inch, or the symbol’s mil size. The minimum and maximum element size values define the range for calibration. Note: A larger minimum-to-maximum range of element size may slow down the calibration phase of the symbol grading process. Once the candidate symbol is identified, the AIM DPM procedure will use and report the actual aperture size used for verification.

Maximum Element Size Maximum Element Size is the maximum expected element size of the candidate symbol in 1/1000 of an inch, or the symbol’s mil size. The minimum and maximum element size values define the range for calibration. Note: A larger minimum-to-maximum range of element size may slow down the calibration phase of the symbol grading process. Once the candidate symbol is identified, the AIM DPM procedure will use and report the actual aperture size used for verification.

3-42

Quadrus Verifier User’s Manual

Page 87

Verification

Wavelength Wavelength represents the wavelength of illumination in the lighting environment used for verification. Important: The operator must ensure that this setting matches that of the illumination source being used.

Lighting Lighting is represented by a combination of ASCII characters (up to 15) signifying the angle and configuration of illumination used in the verification environment. Important: For reliable Direct Part Mark verification results, Microscan recommends setting the Lighting parameter to 90. This is because diffuse perpendicular (or “on axis/bright field”) illumination - in which the symbol plane is parallel to the plane of the Verifier’s sensor and the symbol is uniformly illuminated at a 90° angle of incidence - is most effective for reading Direct Part Marks. Note: Details about other lighting configurations and their corresponding ASCII representations can be found in AIM Global’s “Direct Part Mark (DPM) Quality Guideline”, available at www.aimglobal.org.

Quadrus Verifier User’s Manual

3-43

Page 88

ISO/IEC 15415 Verification by Serial Command

ISO/IEC 15415 Verification by Serial Command Reflectance Calibration Definition:

The Reflectance Calibration command initiates a calibration process with the minimum and maximum reflectance values that are already configured in the Verifier (default minimum: <K531,,,,10> default maximum: <K531,,,85>). Note: If the minimum and maximum reflectance values configured in the Verifier correspond with a different calibration symbol, the results after calibration may be incorrect.

Serial Cmd:

<@VER>

• Place the calibration symbol provided in the approximate center of the Verifier’s field of view before entering the Reflectance Calibration command.

Place the Calibration Symbol as close to the center of the Verifier’s field of view as possible before initiating the Reflectance Calibration process.

IMPORTANT: Keep this card in a safe place! It must be saved and kept in good condition, as it is the Verifier’s most critical setup tool.

You can use the Terminal in ESP to send serial commands. Commands can either be entered in the Send text field, or directly in the terminal.

Important: After the Verifier is calibrated, you must allow 15 minutes of warmup time in Live Video Mode, <K760,2>, before starting a verification process. The LEDs must reach a steady output state for verification results to be valid.

3-44

Quadrus Verifier User’s Manual

Page 89

Verification

ISO/IEC 15415 Single Capture Verification Serial Cmd:

<V1>

Single Capture Verification Process • Once the reflectance calibration process is complete, place the candidate symbol as close to the center of the Verifier’s field of view as possible. • When the candidate symbol is in position, initiate the Single Capture Verification command <V1>. • The Single Capture Verification Report will then appear, detailing the symbol’s adherence to ISO/IEC 15415 requirements.

Single Capture Verification Report The ISO/IEC 15415 Single Capture results show data concerning the reference decode algorithm, symbol contrast, fixed pattern damage, axial and grid non-uniformity, modulation, unused error correction, print growth, symbol type, symbol size, element size, and pixels per element. All but the last five parameters are given a numeric and alphabetical grade.

Quadrus Verifier User’s Manual

3-45

Page 90

ISO/IEC 15415 Verification by Serial Command

ISO/IEC 15415 Multi-Capture Verification Serial Cmd:

<V2>

Multi-Capture Verification Process • Once the reflectance calibration process is complete, place the candidate symbol as close to the center of the Verifier’s field of view as possible. Important: Multi-Capture Verification requires five captures at 72° intervals throughout a 360° rotation. When the symbol is placed in the Verifier’s field of view, its position should be considered its default position -- 0°. ISO/IEC 15415 requires that the symbol’s orientation for the first capture be 45°. This means 45° from the default symbol position, 0°. • When the candidate symbol is in position, initiate the Multi-Capture Verification command <V2>. • The first rotation prompt, shown below, will appear.

Step 1: 45° Rotation

Default Position: 0°

45°

Step 2: 117° Rotation

Default Position: 0°

3-46

117°