The text of a manual · part 8 of 47
Quadrus Verifier User's Manual, pages 71 to 80
Pages 71 to 80 of 470
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan Verifier
Page 71
Verification
Fixed Pattern Damage Grade Definition:
Assesses damage to the symbol’s finder pattern and clock pattern. When enabled, appends the symbol’s Fixed Pattern Damage Grade to the verification output string.
Serial Cmd:
<K756,grade,aperture value,wavelength value,light angle value,decode grade,symbol contrast,fixed pattern damage grade,axial non-uniformity, grid non-uniformity,modulation grade,unused error correction,print growth value,pixels per element value>
Default:
Disabled
Options:
0 = Disabled 1 = Grade
Output Example:
Fixed Pattern Damage Grade highlighted below (shown in numeric form).
symbol_data,2,005,660,45,4,4,075,3,1,0.11,3,0.43,3,2,057,-0.82, 08.7,ECC200,032x032
Axial Non-Uniformity Definition:
Measures deviation along the symbol’s major axes. When enabled, appends the symbol’s Axial Non-Uniformity grade and/or value to the verification output string. Grading Scale: 4 (A) if < 0.06 3 (B) if < 0.08 2 (C) if < 0.10 1 (D) if < 0.12 0 (F) if > 0.12
Serial Cmd:
<K756,grade,aperture value,wavelength value,light angle value,decode grade,symbol contrast,fixed pattern damage grade,axial non-uniformity, grid non-uniformity,modulation grade,unused error correction,print growth value,pixels per element value>
Default:
Disabled
Options:
0 = Disabled 1 = Grade 2 = Value 3 = Grade and Value
Quadrus Verifier User’s Manual
3-27
Page 72
ISO/IEC 15415 Serial Output
Grade (Axial Non-Uniformity) Output Example:
Axial Non-Uniformity Grade highlighted below (shown in numeric form).
symbol_data,2,005,660,45,4,4,075,3,1,3,0.43,3,2,057,-0.82, 08.7,ECC200,032x032
Value (Axial Non-Uniformity) Output Example:
Axial Non-Uniformity Value highlighted below.
symbol_data,2,005,660,45,4,4,075,1,0.11,3,0.43,3,2,057,-0.82, 08.7,ECC200,032x032
Grade and Value (Axial Non-Uniformity) Output Example:
Axial Non-Uniformity Grade and Value highlighted below (grade shown in numeric form).
symbol_data,2,005,660,45,4,4,075,3,1,0.11,3,0.43,3,2,057,-0.82, 08.7,ECC200,032x032
3-28
Quadrus Verifier User’s Manual
Page 73
Verification
Grid Non-Uniformity Definition:
Measures cell deviation from the theoretical or “ideal” grid intersections as determined by the reference decode algorithm. When enabled, appends the symbol’s Grid Non-Uniformity grade and/or value to the verification output string. Grading Scale: 4 (A) if < 0.38 3 (B) if < 0.50 2 (C) if < 0.63 1 (D) if < 0.75 0 (F) if > 0.75
Serial Cmd:
<K756,grade,aperture value,wavelength value,light angle value,decode grade,symbol contrast,fixed pattern damage grade,axial non-uniformity,grid non-uniformity,modulation grade,unused error correction,print growth value,pixels per element value>
Default:
Disabled
Options:
0 = Disabled 1 = Grade 2 = Value 3 = Grade and Value
Grade (Grid Non-Uniformity) Output Example:
Grid Non-Uniformity Grade highlighted below (shown in numeric form).
symbol_data,2,005,660,45,4,4,075,3,1,0.11,3,3,2,057,-0.82, 08.7,ECC200,032x032
Value (Grid Non-Uniformity) Output Example:
Grid Non-Uniformity Value highlighted below.
symbol_data,2,005,660,45,4,4,075,3,1,0.11,0.43,3,2,057,-0.82, 08.7,ECC200,032x032
Grade and Value (Grid Non-Uniformity) Output Example:
Grid Non-Uniformity Grade and Value highlighted below (grade shown in numeric form).
symbol_data,2,005,660,45,4,4,075,3,1,0.11,3,0.43,3,2,057,-0.82, 08.7,ECC200,032x032 Quadrus Verifier User’s Manual
3-29
Page 74
ISO/IEC 15415 Serial Output
Modulation Grade Definition:
Assesses the reflectance uniformity of the symbol’s light and dark elements. When enabled, appends the symbol’s Modulation Grade to the verification output string. Grading Scale: 4 (A) if > 0.50 3 (B) if > 0.40 2 (C) if > 0.30 1 (D) if > 0.20 0 (F) if < 0.20
Serial Cmd:
<K756,grade,aperture value,wavelength value,light angle value,decode grade,symbol contrast,fixed pattern damage grade,axial non-uniformity,grid non-uniformity,modulation grade,unused error correction,print growth value,pixels per element value>
Default:
Disabled
Options:
0 = Disabled 1 = Grade
Output Example:
Modulation Grade highlighted below (shown in numeric form).
symbol_data,2,005,660,45,4,4,075,3,1,0.11,3,0.43,3,2,057,-0.82, 08.7,ECC200,032x032
3-30
Quadrus Verifier User’s Manual
Page 75
Verification
Unused Error Correction Definition:
Determines the amount of error correction capacity that was used to decode the symbol, and indicates the remaining amount of available error correction. When enabled, appends the symbol’s Unused Error Correction grade and/or value to the verification output string. Grading Scale: 4 (A) if > 0.62 3 (B) if > 0.50 2 (C) if > 0.37 1 (D) if > 0.25 0 (F) if < 0.25
Serial Cmd:
<K756,grade,aperture value,wavelength value,light angle value,decode grade,symbol contrast,fixed pattern damage grade,axial non-uniformity,grid non-uniformity,modulation grade,unused error correction,print growth value,pixels per element value>
Default:
Disabled
Options:
0 = Disabled 1 = Grade 2 = Value 3 = Grade and Value
Grade Output Example:
Unused Error Correction Grade highlighted below (shown in numeric form).
symbol_data,2,005,660,45,4,4,075,3,1,0.11,3,0.43,3,2,-0.82, 08.7,ECC200,032x032
Value Output Example:
Unused Error Correction Value highlighted below.
symbol_data,2,005,660,45,4,4,075,3,1,0.11,3,0.43,3,057,-0.82, 08.7,ECC200,032x032
Grade and Value Output Example:
Unused Error Correction Grade and Value highlighted below (grade shown in numeric form).
symbol_data,2,005,660,45,4,4,075,3,1,0.11,3,0.43,3,2,057,-0.82, 08.7,ECC200,032x032 Quadrus Verifier User’s Manual
3-31
Page 76
ISO/IEC 15415 Serial Output
Print Growth Value Definition:
Determines the degree to which a symbol is overprinted or underprinted. When enabled, appends the symbol’s Print Growth Value to the verification output string.
Serial Cmd:
<K756,grade,aperture value,wavelength value,light angle value,decode grade,symbol contrast,fixed pattern damage grade,axial non-uniformity,grid non-uniformity,modulation grade,unused error correction,print growth value,pixels per element value>
Default:
Disabled
Options:
0 = Disabled 1 = Value
Output Example:
Print Growth Value highlighted below.
symbol_data,2,005,660,45,4,4,075,3,1,0.11,3,0.43,3,2,057,-0.82, 08.7,ECC200,032x032
Pixels Per Element Value Definition:
Counts the number of pixels in each symbol element. The higher the Pixels Per Element count, the more readable the symbol. When enabled, appends the symbol’s Pixels Per Element Value to the verification output string.
Serial Cmd:
<K756,grade,aperture value,wavelength value,light angle value,decode grade,symbol contrast,fixed pattern damage grade,axial non-uniformity,grid non-uniformity,modulation grade,unused error correction,print growth value,pixels per element value>
Default:
Disabled
Options:
0 = Disabled 1 = Value
Output Example:
Pixels Per Element Value highlighted below.
symbol_data,2,005,660,45,4,4,075,3,1,0.11,3,0.43,3,2,057,-0.82, 08.7,ECC200,032x032
3-32
Quadrus Verifier User’s Manual
Page 77
Verification
ISO/IEC 15415 Output by ESP Grade Output Note: Grade type (Alpha or Numeric) is determined by the “ISO Grade Type” parameter.
Aperture Expresses the Synthetic Aperture Value in the verification report.
Quadrus Verifier User’s Manual
3-33
Page 78
ISO/IEC 15415 Output by ESP
Wavelength Wavelength Value expresses the peak wavelength of LED light output, measured in nanometers (nm).
Light Angle Defines the angle of incidence of LED illumination.
3-34
Quadrus Verifier User’s Manual
Page 79
Verification
Decode To receive a passing Decode Grade, a symbol must be successfully decoded using the Verifier’s reference decode algorithm. When enabled, includes the symbol’s Decode Grade in the verification report. A symbol will receive a 0 (F) if it cannot be decoded using the specified reference decode algorithm. It will receive a 4 (A) if it can be decoded using the specified reference decode algorithm.
Symbol Contrast Measures the difference between light and dark symbol elements. This measurement also includes the symbol’s Quiet Zone. When enabled, includes the Symbol Contrast grade and/or value in the verification report.
Quadrus Verifier User’s Manual
3-35
Page 80
ISO/IEC 15415 Output by ESP
Fixed Pattern Damage Assesses damage to the symbol’s finder pattern and clock pattern. When enabled, includes the symbol’s Fixed Pattern Damage Grade in the verification report.
Axial Non-Uniformity Measures deviation along the symbol’s major axes. When enabled, includes the symbol’s Axial Non-Uniformity grade and/or value in the verification report.
3-36
Quadrus Verifier User’s Manual