Page 91

Verification

Step 3: 189° Rotation

Default Position: 0°

189°

Step 4: 261° Rotation

Default Position: 0°

261°

Step 5: 333° Rotation

Default Position: 0°

Quadrus Verifier User’s Manual

333°

3-47

Page 92

ISO/IEC 15415 Verification by Serial Command

Multi-Capture Verification Report After the final rotation and trigger, the Verifier will output the ISO/IEC 15415 Multi-Capture Verification Report, shown below. The ISO/IEC 15415 Multi-Capture parameters are the same as those for ISO/IEC 15415 Single Capture, but multi-capture results are determined only after the symbol is read at five 72° intervals throughout a full 360° rotation. The overall symbol grade is based on an arithmetic mean of the results from the five reads.

3-48

Quadrus Verifier User’s Manual

Page 93

Verification

AS9132 /JES 131 Marking Method Element Shape Definition:

The shape of the symbol’s printed, dot peen, or Etch markings. Each symbol element represents one bit (‘0’ or ‘1’) of binary data. Symbol elements can be either round or square, provided that they are consistent in size and spacing throughout the symbol. Choice of Element Shape setting should be based on the actual element shape used in the symbol being verified.

Serial Cmd:

<K711,element shape,marking method,JES 131>

Default:

Round

Options:

0 = Round 1 = Square

Marking Method Definition:

The marking method used to create the symbol. Choice of Marking Method setting should be based on the method used to create the symbol being verified.

Serial Cmd:

<K711,element shape,marking method,JES 131>

Default:

Dot Peen

Options:

0 = Dot Peen 1 = Laser or Chemical Etch

Dot Peen Dot peen is a percussive marking method that uses changes in depth to create the contrast between light and dark elements. Dot peen marks are imprinted directly on parts. This method is recommended for applications in which marks must last the entire life cycle of the part.

Laser or Chemical Etch Laser etch marks are applied directly to parts using a YAG, CO2, or YVO4 laser. Laser etch marks are ideal for high-volume automated environments, and they can be used on a wide variety of substrates. Chemical etch marks are created using an electro-chemical process by which a low voltage electrical current passes through a stencil and onto a part’s surface. This process only works with conductive metal substrates. Chemical etch marks are best suited to low-volume product runs because of the complexity and time-intensive nature of the marking process.

Quadrus Verifier User’s Manual

3-49

Page 94

AS9132 /JES 131 Marking Method

JES 131 Definition:

When enabled, sets verification parameters to the JES 131 specification rather than the AS9132 specification. JES 131 specifies a Cell Fill upper threshold of 110% instead of AS9132’s 105%. JES 131 verification reports will display the heading “JES 131 Verification Report”, as shown in the example below.

Serial Cmd:

<K711,element shape,marking method,JES 131>

Default:

Disable

Options:

0 = Disabled 1 = Enabled

3-50

Quadrus Verifier User’s Manual

Page 95

Verification

AS9132 /JES 131 Marking Method by ESP Element Shape The shape of the symbol’s printed, dot peen, or etch markings. Each symbol element represents one bit (‘0’ or ‘1’) of binary data. Symbol elements can be either round or square, provided that they are consistent in size and spacing throughout the symbol. Choice of Element Shape setting should be based on the actual element shape used in the symbol being verified.

Marking Method The marking method used to create the symbol (inkjet, dot peen, laser or electro-chemical etch, etc.). Choice of Marking Method setting should be based on the method used to create the symbol being verified.

Quadrus Verifier User’s Manual

3-51

Page 96

AS9132 /JES 131 Marking Method by ESP

JES 131 When enabled, sets verification parameters to the JES 131 specification rather than the AS9132 specification. JES 131 specifies a Cell Fill upper threshold of 110% instead of AS9132’s 105%. JES 131 verification reports will display the heading “JES 131 Verification Report”.

3-52

Quadrus Verifier User’s Manual

Page 97

Verification

AS9132 Serial Output Dot Center Offset Definition:

Measures the deviation of actual dot centers from theoretical or “ideal” dot centers. Worst Case Value output shows the quality of the worst dot, expressed as a percentage of that particular dot center’s deviation from the ideal. Average Value output shows the average quality of all dots, expressed as a percentage of average dot center deviation from the ideal. Important: Dot Center Offset is available only if Element Shape is set to Round <K711,0>. It cannot evaluate square elements.

Serial Cmd:

<K712,dot center offset,percentage failed offset,cell fill,percentage failed cell fill,dot ovality,percentage failed ovality,angle of distortion,symbol contrast,quiet zone grade,pixels per element value>

Default:

Disabled

Options:

0 = Disabled

1 = Worst Case Value

2 = Average Value

3 = Worst Case and Average Values

4 = Grade

5 = Grade and Worst Case Value

6 = Grade and Average Value 7 = Grade, Worst Case and Average Values

Worst Case Value (Dot Center Offset) Definition: Output Example:

Worst Case Value is a percentage, and is shown in the output string as a three-digit value from 000 to 100. For example, “004” = 4%. Dot Center Offset Worst Case Value highlighted below.

symbol_data,004,F,045,057,P,002,001,F,-08.20,P,034,P,12.4,ECC200, 018x018

Quadrus Verifier User’s Manual

3-53

Page 98

AS9132 Serial Output

Average Value (Dot Center Offset) Definition: Output Example:

Average Value is a percentage, and is shown in the output string as a three-digit value from 000 to 100. For example, “003” = 3%. Dot Center Offset Average Value highlighted below.

symbol_data,003,F,045,057,P,002,001,F,-08.20,P,034,P,12.4,ECC200, 018x018

Worst Case and Average Values (Dot Center Offset) Output Example:

Dot Center Offset Worst Case Value and Average Value highlighted below.

symbol_data,004,003,F,045,057,P,002,001,F,-08.20,P,034,P,12.4, ECC200,018x018

Grade (Dot Center Offset) Definition: Output Example:

Grades take into account both the worst case and average values.A passing grade is represented by ‘P’, and a failing grade is represented by ‘F’. Dot Center Offset Grade highlighted below.

symbol_data,P,F,045,057,P,002,001,F,-08.20,P,034,P,12.4,ECC200, 018x018

Grade and Worst Case Value (Dot Center Offset) Output Example:

Dot Center Offset Grade and Worst Case Value highlighted below.

symbol_data,P,004,F,045,057,P,002,001,F,-08.20,P,034,P,12.4, ECC200,018x018

Grade and Average Value (Dot Center Offset) Output Example:

Dot Center Offset Grade and Average Value highlighted below.

symbol_data,P,003,F,045,057,P,002,001,F,-08.20,P,034,P,12.4, ECC200,018x018

Grade, Worst Case, and Average Values (Dot Center Offset) Output Example:

Dot Center Offset Grade, Worst Case Value, and Average Value highlighted below.

symbol_data,P,004,003,F,045,057,P,002,001,F,-08.20,P,034,P,12.4, ECC200,018x018 3-54

Quadrus Verifier User’s Manual

Page 99

Verification

Percentage Failed Offset Definition:

When enabled, reports the percentage of dots that failed Dot Center Offset evaluation.

Serial Cmd:

<K712,dot center offset,percentage failed offset,cell fill,percentage failed cell fill,dot ovality,percentage failed ovality,angle of distortion,symbol contrast, quiet zone grade,pixels per element value>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Cell Fill Definition:

Measures the percentage of the ideal cell size that the module or element fills. Worst Case Value output shows the quality of the worst element, expressed as a percentage of the ideal cell size filled by that particular element. Average Value output shows the average quality of all elements, expressed as a percentage of the ideal cell size filled by the average element.

Serial Cmd:

<K712,dot center offset,percentage failed offset,cell fill,percentage failed cell fill,dot ovality,percentage failed ovality,angle of distortion,symbol contrast, quiet zone grade,pixels per element value>

Default:

Disabled

Options:

0 = Disabled

1 = Worst Case Value

2 = Average Value

3 = Worst Case and Average Values

4 = Grade

5 = Grade and Worst Case Value

6 = Grade and Average Value 7 = Grade, Worst Case and Average Values

Worst Case Value (Cell Fill) Definition:

Worst Case Value is a percentage, and is shown in the output string as a three-digit value from 000 to 100. For example, “045” = 45%.

Output Example:

Cell Fill Worst Case Value highlighted below.

symbol_data,P,004,003,045,P,002,001,F,-08.20,P,034,P,12.4,ECC200, 018x018

Average Value (Cell Fill) Definition: Output Example:

Average Value is a percentage, and is shown in the output string as a three-digit value from 000 to 100. For example, “057” = 57%. Cell Fill Average Value highlighted below.

symbol_data,P,004,003,057,P,002,001,F,-08.20,P,034,P,12.4,ECC200, 018x018 Quadrus Verifier User’s Manual

3-55

Page 100

AS9132 Serial Output

Worst Case and Average Values (Cell Fill) Output Example:

Cell Fill Worst Case Value and Average Value highlighted below.

symbol_data,P,004,003,045,057,P,002,001,F,-08.20,P,034,P,12.4, ECC200,018x018

Grade (Cell Fill) Definition: Output Example:

Grades take into account both the worst case and average values. A passing grade is represented by ‘P’, and a failing grade is represented by ‘F’. Cell Fill Grade highlighted below.

symbol_data,P,004,003,F,P,002,001,F,-08.20,P,034,P,12.4,ECC200, 018x018

Grade and Worst Case Value (Cell Fill) Output Example:

Cell Fill Grade and Worst Case Value highlighted below.

symbol_data,P,004,003,F,045,P,002,001,F,-08.20,P,034,P,12.4, ECC200,018x018

Grade and Average Value (Cell Fill) Output Example:

Cell Fill Grade and Average Value highlighted below.

symbol_data,P,004,003,F,057,P,002,001,F,-08.20,P,034,P,12.4, ECC200,018x018

Grade, Worst Case, and Average Values (Cell Fill) Output Example:

Cell Fill Grade, Worst Case Value, and Average Value highlighted below.

symbol_data,P,004,003,F,045,057,P,002,001,F,-08.20,P,034,P,12.4, ECC200,018x018

3-56

Quadrus Verifier User’s Manual