Page 101

Verification

Percentage Failed Cell Fill Definition:

When enabled, reports the percentage of elements that failed Cell Fill evaluation.

Serial Cmd:

<K712,dot center offset,percentage failed offset,cell fill,percentage failed cell fill,dot ovality,percentage failed ovality,angle of distortion,symbol contrast, quiet zone grade,pixels per element value>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Dot Ovality Definition:

Measures the extent to which round elements deviate from a perfect circle. Worst Case Value output shows the quality of the worst element, expressed as a percentage of the deviation of the actual dot from the ideal. Average Value output shows the average quality of all elements, expressed as a percentage of the deviation of the average dot from the ideal. For a symbol to achieve a passing grade, Dot Ovality must not exceed 20%, and no more than 2% of the symbol’s dots can exceed 20% ovality. Important: Dot Ovality is available only if Element Shape is set to Round <K711,0>. It cannot evaluate square elements.

Serial Cmd:

<K712,dot center offset,percentage failed offset,cell fill,percentage failed cell fill,dot ovality,percentage failed ovality,angle of distortion,symbol contrast, quiet zone grade,pixels per element value>

Default:

Disabled

Options:

0 = Disabled

1 = Worst Case Value

2 = Average Value

3 = Worst Case and Average Values

4 = Grade

5 = Grade and Worst Case Value

6 = Grade and Average Value 7 = Grade, Worst Case and Average Values

Worst Case Value (Dot Ovality) Definition: Output Example:

Worst Case Value is a percentage, and is shown in the output string as a three-digit value from 000 to 100. For example, “002” = 2%. Dot Ovality Worst Case Value highlighted below.

symbol_data,P,004,003,F,045,057,002,-08.20,P,034,P,12.4,ECC200, 018x018

Quadrus Verifier User’s Manual

3-57

Page 102

AS9132 Serial Output

Average Value (Dot Ovality) Definition: Output Example:

Average Value is a percentage, and is shown in the output string as a three-digit value from 000 to 100. For example, “001” = 1%. Dot Ovality Average Value highlighted below.

symbol_data,P,004,003,F,045,057,001,F,-08.20,P,034,P,12.4,ECC200, 018x018

Worst Case and Average Values (Dot Ovality) Output Example:

Dot Ovality Worst Case Value and Average Value highlighted below.

symbol_data,P,004,003,F,045,057,002,001,F,-08.20,P,034,P,12.4, ECC200,018x018

Grade (Dot Ovality) Definition: Output Example:

Grades take into account both the worst case and average values. A passing grade is represented by ‘P’, and a failing grade is represented by ‘F’. Dot Ovality Grade highlighted below.

symbol_data,P,004,003,F,045,057,P,F,-08.20,P,034,P,12.4,ECC200, 018x018

Grade and Worst Case Value (Dot Ovality) Output Example:

Dot Ovality Grade and Worst Case Value highlighted below.

symbol_data,P,004,003,F,045,057,P,002,F,-08.20,P,034,P,12.4, ECC200,018x018

Grade and Average Value (Dot Ovality) Output Example:

Dot Ovality Grade and Average Value highlighted below.

symbol_data,P,004,003,F,045,057,P,001,F,-08.20,P,034,P,12.4, ECC200,018x018

Grade, Worst Case, and Average Values (Dot Ovality) Output Example:

Dot Ovality Grade, Worst Case Value, and Average Value highlighted below.

symbol_data,P,004,003,F,045,057,P,002,001,F,-08.20,P,034,P,12.4, ECC200,018x018 3-58

Quadrus Verifier User’s Manual

Page 103

Verification

Percentage Failed Ovality Definition:

When enabled, reports the percentage of dots that failed for Dot Ovality.

Serial Cmd:

<K712,dot center offset,percentage failed offset,cell fill,percentage failed cell fill,dot ovality,percentage failed ovality,angle of distortion,symbol contrast, quiet zone grade,pixels per element value>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Angle of Distortion Definition:

Measures the symbol’s deviation from a 90° relation between row and column. To receive a passing grade, the symbol’s Angle of Distortion must not exceed ± 7°.

Serial Cmd:

<K712,dot center offset,percentage failed offset,cell fill,percentage failed cell fill,dot ovality,percentage failed ovality,angle of distortion,symbol contrast, quiet zone grade,pixels per element value>

Default:

Disabled

Options:

0 = Disabled

1 = Grade

2 = Value

3 = Grade and Value

Grade Definition:

A passing grade is represented by ‘P’, and a failing grade is represented by ‘F’.

Output Example:

Angle of Distortion Grade highlighted below.

symbol_data,P,004,003,F,045,057,P,002,001,F,P,034,P,12.4,ECC200, 018x018

Value Definition:

Angle of Distortion shows the row/column angle deviation from 90°.

Output Example:

Angle of Distortion Value highlighted below.

symbol_data,P,004,003,F,045,057,P,002,001,-08.20,P,034,P,12.4, ECC200,018x018

Grade and Value Output Example:

Angle of Distortion Grade and Value highlighted below.

symbol_data,P,004,003,F,045,057,P,002,001,F,-08.20,P,034,P,12.4, ECC200,018x018 Quadrus Verifier User’s Manual

3-59

Page 104

AS9132 Serial Output

Symbol Contrast Definition:

Measures the difference in the light and dark values of the symbol’s elements. To receive a passing grade, the difference in value between the mark (dark value) and the substrate (light value) must be 20% or greater. Important: Symbol Contrast output is only available when Marking Method is set to Laser or Chemical Etch <K711,,1>.

Serial Cmd:

<K712,dot center offset,percentage failed offset,cell fill,percentage failed cell fill,dot ovality,percentage failed ovality,angle of distortion,symbol contrast, quiet zone grade,pixels per element value>

Default:

Disabled

Options:

0 = Disabled

1 = Grade (Laser/Chemical Etch Only)

2 = Value

3 = Grade and Value (Laser/Chemical Etch Only)

Grade Definition:

A passing grade is represented by ‘P’, and a failing grade is represented by ‘F’.

Output Example:

Symbol Contrast Grade highlighted below.

symbol_data,P,004,003,F,045,057,P,002,001,F,-08.20,P,P,12.4, ECC200,018x018

Value Definition: Output Example:

Symbol Contrast Value is a percentage, and is shown in the output string as a three-digit value from 000 to 100. For example, “034” = 34%. Symbol Contrast Value highlighted below.

symbol_data,P,004,003,F,045,057,P,002,001,F,-08.20,034,P,12.4, ECC200,018x018

Grade and Value Output Example:

Symbol Contrast Grade and Value highlighted below.

symbol_data,P,004,003,F,045,057,P,002,001,F,-08.20,P,034,P,12.4, ECC200,018x018

3-60

Quadrus Verifier User’s Manual

Page 105

Verification

Quiet Zone Grade Definition:

The Quiet Zone is a clear space of at least one module/element surrounding the symbol, required for symbol readability. When enabled, this feature outputs a pass (‘P’) or fail (‘F’) grade for Quiet Zone.

Serial Cmd:

<K712,dot center offset,percentage failed offset,cell fill,percentage failed cell fill,dot ovality,percentage failed ovality,angle of distortion,symbol contrast, quiet zone grade,pixels per element value>

Default:

Disabled

Options:

0 = Disabled

Output Example:

Quiet Zone Grade highlighted below.

1 = Grade symbol_data,P,004,003,F,045,057,P,002,001,F,-08.20,P,034,P,12.4, ECC200,018x018

Pixels Per Element Value Definition:

The number of pixels in each symbol element. The higher the Pixels Per Element count, the more readable the symbol. When enabled, this feature outputs the pixels per element value.

Serial Cmd:

<K712,dot center offset,percentage failed offset,cell fill,percentage failed cell fill,dot ovality,percentage failed ovality,angle of distortion,symbol contrast, quiet zone grade,pixels per element value>

Default:

Disabled

Options:

0 = Disabled

Output Example:

Pixels Per Element Value highlighted below.

1 = Value symbol_data,P,004,003,F,045,057,P,002,001,F,-08.20,P,034,P,12.4, ECC200,018x018

Quadrus Verifier User’s Manual

3-61

Page 106

AS9132 Output by ESP

AS9132 Output by ESP Dot Center Offset Measures the deviation of actual dot centers from theoretical or “ideal” dot centers. Ideal dot centers are based upon a prior grid-mapping calculation. It is not assumed that the cells are evenly placed, and they are adjusted if they are skewed. Important: Dot Center Offset is available only if Element Shape is set to Round.

Percentage Failed Offset When enabled, reports the percentage of dots that failed Dot Center Offset evaluation.

3-62

Quadrus Verifier User’s Manual

Page 107

Verification

Cell Fill Measures the percentage of the ideal cell size that the module or element fills. Worst Case Value output shows the quality of the worst element, expressed as a percentage of the ideal cell size filled by that particular element. Average Value output shows the average quality of all elements, expressed as a percentage of the ideal cell size filled by the average element.

Percentage Failed Cell Fill When enabled, reports the percentage of elements that failed Cell Fill evaluation.

Quadrus Verifier User’s Manual

3-63

Page 108

AS9132 Output by ESP

Dot Ovality Measures the extent to which round elements deviate from a perfect circle. For a symbol to achieve a passing grade, Dot Ovality must not exceed 20%, and no more than 2% of the symbol’s dots can exceed 20% ovality.

Percentage Failed Ovality When enabled, reports the percentage of dots that failed Dot Ovality evaluation.

3-64

Quadrus Verifier User’s Manual

Page 109

Verification

Angle of Distortion Measures the symbol’s deviation from a 90° relation between row and column. To receive a passing grade, the symbol’s Angle of Distortion must not exceed ± 7°.

Symbol Contrast Measures the difference in the light and dark values of the symbol’s elements. To receive a passing grade, the difference in value between the mark (dark value) and the substrate (light value) must be 20% or greater. Important: Symbol Contrast output is only available when Marking Method is set to Laser or Chemical Etch.

Quadrus Verifier User’s Manual

3-65

Page 110

AS9132 Output by ESP

Quiet Zone Grade The Quiet Zone is an unmarked space surrounding a symbol, required for symbol readability. To receive a passing grade, the Quiet Zone must be at least one element in width.

Pixels Per Element The number of pixels in each symbol element. The higher the Pixels Per Element count, the more readable the symbol. When enabled, this feature outputs the Pixels Per Element value.

3-66

Quadrus Verifier User’s Manual