Page 321
Diagnostics
Counts (Read Only) Counts for Power-on/Reset/Saves are stored in the reader and can be displayed at any time in response to serial commands listed here, in the embedded Diagnostic menu, or in ESP by requesting reader settings. If you did not choose to receive reader settings upon connection in ESP, you can right-click anywhere in the Diagnostic window and select Receive Reader Settings.
Power-On Definition:
Displays a count of the number of times power to the reader is recycled.
Serial Cmd:
<K406,power-on,resets,power-on saves,customer default saves>
Resets Definition:
Displays a count of the number of times the reader is reset.
Serial Cmd:
<K406,power-on,resets,power-on saves,customer default saves>
Power-On Saves Definition:
Displays a count of the number of power-on saves <Z> command.
Serial Cmd:
<K406,power-on,resets,power-on saves,customer default saves>
Custom Default Saves Definition:
Displays a count of the number of power-on saves (customer defaults) to flash memory (<Zc> command)
Serial Cmd:
<K406,power-on,resets,power-on saves,customer default saves>
Quadrus Verifier User’s Manual
10-3
Page 322
External Camera Message
External Camera Message Note: This feature cannot be used if in a Continuous Read mode.
Disconnect Status Definition:
When enabled, a message is sent when the system detects that the external camera is not connected.
Conditions:
On power-on, if enabled and the external camera is not connected, the “disconnect message” will be output. The message will not be output again unless power is cycled or a “disconnect” condition occurs after a “connect” condition with connect message enabled. Note: If the external camera is configured in “Interlaced” mode instead of “Progressive,” this will be detected as a Disconnect condition.
Serial Cmd:
<K410,disconnect msg status,disconnect message,connect msg status, connect message>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Disconnect Message Serial Cmd:
<K410,disconnect msg status,disconnect message,connect msg status, connect message>
Default:
EX_CAM_OFF
Options:
Any 1 to 10 ASCII characters except NULL, < , or >.
Connect Status Definition:
When enabled, a message is sent when the system detects that the external camera is connected.
Conditions:
On power-on, if enabled and the external camera is connected, the “connect message” will be output. The message will not be output again unless power is cycled or a “connect” condition occurs after a “disconnect” condition with connect message enabled. Note: If the external camera is configured in “Interlaced” mode instead of “Progressive,” this will not be detected as a connect condition.
Serial Cmd:
<K410,disconnect msg status,disconnect message,connect msg status, connect message>
Default:
Disabled
Options:
0 = Disabled
10-4
1 = Enabled
Quadrus Verifier User’s Manual
Page 323
Diagnostics
Connect Message Serial Cmd:
<K410,disconnect msg status,disconnect message,connect msg status, connect message>
Default:
EX_CAM_ON
Options:
Any 1 to 10 ASCII characters except NULL, < or >.
Quadrus Verifier User’s Manual
10-5
Page 324
Over Temperature Message
Over Temperature Message Over Temperature Status Usage:
Helps ensure that the reader is being used within its temperature specification.
Definition:
When enabled, a message is sent whenever the system detects that the internal temperature has exceeded it's specified operating temperature.
Serial Cmd:
<K402,over temperaturestatus,warning message>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Warning Message Serial Cmd:
<K402,over temperature status,warning message>
Default:
OVER_TEMP
Options:
Any 1 to 10 ASCII characters except NULL, < , or >.
10-6
Quadrus Verifier User’s Manual
Page 325
Diagnostics
Service Message Service Message Status Definition:
When enabled, a message is sent whenever the system detects that a user-set service time has expired. The service timer is reset on power-on, thus the timer only records the time that has elapsed since the last reset. The message is sent every time the timer expires.
Serial Cmd:
<K409,status,service message,threshold,resolution>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Service Message Serial Cmd:
<K409,status,service message,threshold,resolution>
Default:
SERVICE
Options:
Any 1 to 10 ASCII characters except NULL, < , or >.
Threshold Definition:
Sets the number of hours or minutes that will transpire before the service message is output.
Serial Cmd:
<K409,status,service message,threshold,resolution>
Default:
300 (5 minutes)
Options:
1 to 65535
Resolution Definition:
Records time in seconds or minutes.
Serial Cmd:
<K409,status,service message,threshold,resolution>
Default:
Seconds
Options:
0 = Seconds
Quadrus Verifier User’s Manual
1 = Minutes
10-7
Page 326
Service Message
10-8
Quadrus Verifier User’s Manual
Page 327
11 Camera Setup Contents Camera Setup by ESP ............................................................................................................... 11-2 Camera Setup Serial Commands............................................................................................... 11-3 Video .......................................................................................................................................... 11-4 Evaluation................................................................................................................................... 11-6 Region of Interest (ROI) ........................................................................................................... 11-10 IP Database.............................................................................................................................. 11-13 Dynamic Setup ......................................................................................................................... 11-14 Camera..................................................................................................................................... 11-16 Illumination Source ................................................................................................................... 11-17 Thresholding............................................................................................................................. 11-18 Image Processing Settings....................................................................................................... 11-19 Hollow Mode............................................................................................................................. 11-21 Mirrored Image ......................................................................................................................... 11-22
This section explains the physical controls of the internal camera, image acquisition, database settings, and image diagnostics. Note: Camera Setup only applies to the Quadrus Verifier internal camera. If using an external camera, images are received on an as-ready basis. Allow a 33mS delay for the first image to appear from an external camera.
Quadrus Verifier User’s Manual
11-1
Page 328
Camera Setup by ESP
Camera Setup by ESP
Click this button to bring up the Camera Setup menu.
To open the entire contents of the tree control, hold down the Alt key and single-click the +. To close the entire contents of the tree control, hold down the Alt key and single-click the - .
To open nested options, single-click the +.
11-2
To change a setting, double-click the setting and use your cursor to scroll through the options.
Quadrus Verifier User’s Manual
Page 329
Camera Setup
Camera Setup Serial Commands Region of Interest Camera Illumination Source Thresholding Processing Mode Multiple Symbols in Fast Linear Mode Image Processing Timeout Hollow Mode Mirrored Image
Quadrus Verifier User’s Manual
<K516,top,left,height,width> <K540,shutter speed,gain> <K535,illumination source> <K512,threshold mode,threshold value> <K513,processing mode> <K518,number of symbols> <K245,image processing timeout> <K517,hollow status> <K514,mirrored image>
11-3
Page 330
Video
Video In the Camera menu you can locate and capture images just as in EZ Mode when first starting ESP.
Locate Activates the target pattern and the video view in ESP to help you center the symbol in the field of view.
Calibrate If you haven’t already calibrated the symbol, 1. Click the Locate button and center the target pattern over the symbol. 2. Click the Calibrate button to optimize read rate. The Verifier will search through various IP (image processing) settings to determine the best configuration for verifying symbols. A successful calibration will display the calibrated symbol image a message, “Calibrated successfully”. 3. Click Close on the Calibration dialog. The symbol’s data and related features will be presented below the image display window.
Calibrate by Serial Command Send <@CAL> to begin calibration.
11-4