Page 321

Diagnostics

Counts (Read Only) Counts for Power-on/Reset/Saves are stored in the reader and can be displayed at any time in response to serial commands listed here, in the embedded Diagnostic menu, or in ESP by requesting reader settings. If you did not choose to receive reader settings upon connection in ESP, you can right-click anywhere in the Diagnostic window and select Receive Reader Settings.

Power-On Definition:

Displays a count of the number of times power to the reader is recycled.

Serial Cmd:

<K406,power-on,resets,power-on saves,customer default saves>

Resets Definition:

Displays a count of the number of times the reader is reset.

Serial Cmd:

<K406,power-on,resets,power-on saves,customer default saves>

Power-On Saves Definition:

Displays a count of the number of power-on saves <Z> command.

Serial Cmd:

<K406,power-on,resets,power-on saves,customer default saves>

Custom Default Saves Definition:

Displays a count of the number of power-on saves (customer defaults) to flash memory (<Zc> command)

Serial Cmd:

<K406,power-on,resets,power-on saves,customer default saves>

Quadrus Verifier User’s Manual

10-3

Page 322

External Camera Message

External Camera Message Note: This feature cannot be used if in a Continuous Read mode.

Disconnect Status Definition:

When enabled, a message is sent when the system detects that the external camera is not connected.

Conditions:

On power-on, if enabled and the external camera is not connected, the “disconnect message” will be output. The message will not be output again unless power is cycled or a “disconnect” condition occurs after a “connect” condition with connect message enabled. Note: If the external camera is configured in “Interlaced” mode instead of “Progressive,” this will be detected as a Disconnect condition.

Serial Cmd:

<K410,disconnect msg status,disconnect message,connect msg status, connect message>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Disconnect Message Serial Cmd:

<K410,disconnect msg status,disconnect message,connect msg status, connect message>

Default:

EX_CAM_OFF

Options:

Any 1 to 10 ASCII characters except NULL, < , or >.

Connect Status Definition:

When enabled, a message is sent when the system detects that the external camera is connected.

Conditions:

On power-on, if enabled and the external camera is connected, the “connect message” will be output. The message will not be output again unless power is cycled or a “connect” condition occurs after a “disconnect” condition with connect message enabled. Note: If the external camera is configured in “Interlaced” mode instead of “Progressive,” this will not be detected as a connect condition.

Serial Cmd:

<K410,disconnect msg status,disconnect message,connect msg status, connect message>

Default:

Disabled

Options:

0 = Disabled

10-4

1 = Enabled

Quadrus Verifier User’s Manual

Page 323

Diagnostics

Connect Message Serial Cmd:

<K410,disconnect msg status,disconnect message,connect msg status, connect message>

Default:

EX_CAM_ON

Options:

Any 1 to 10 ASCII characters except NULL, < or >.

Quadrus Verifier User’s Manual

10-5

Page 324

Over Temperature Message

Over Temperature Message Over Temperature Status Usage:

Helps ensure that the reader is being used within its temperature specification.

Definition:

When enabled, a message is sent whenever the system detects that the internal temperature has exceeded it's specified operating temperature.

Serial Cmd:

<K402,over temperaturestatus,warning message>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Warning Message Serial Cmd:

<K402,over temperature status,warning message>

Default:

OVER_TEMP

Options:

Any 1 to 10 ASCII characters except NULL, < , or >.

10-6

Quadrus Verifier User’s Manual

Page 325

Diagnostics

Service Message Service Message Status Definition:

When enabled, a message is sent whenever the system detects that a user-set service time has expired. The service timer is reset on power-on, thus the timer only records the time that has elapsed since the last reset. The message is sent every time the timer expires.

Serial Cmd:

<K409,status,service message,threshold,resolution>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Service Message Serial Cmd:

<K409,status,service message,threshold,resolution>

Default:

SERVICE

Options:

Any 1 to 10 ASCII characters except NULL, < , or >.

Threshold Definition:

Sets the number of hours or minutes that will transpire before the service message is output.

Serial Cmd:

<K409,status,service message,threshold,resolution>

Default:

300 (5 minutes)

Options:

1 to 65535

Resolution Definition:

Records time in seconds or minutes.

Serial Cmd:

<K409,status,service message,threshold,resolution>

Default:

Seconds

Options:

0 = Seconds

Quadrus Verifier User’s Manual

1 = Minutes

10-7

Page 326

Service Message

10-8

Quadrus Verifier User’s Manual

Page 327

11 Camera Setup Contents Camera Setup by ESP ............................................................................................................... 11-2 Camera Setup Serial Commands............................................................................................... 11-3 Video .......................................................................................................................................... 11-4 Evaluation................................................................................................................................... 11-6 Region of Interest (ROI) ........................................................................................................... 11-10 IP Database.............................................................................................................................. 11-13 Dynamic Setup ......................................................................................................................... 11-14 Camera..................................................................................................................................... 11-16 Illumination Source ................................................................................................................... 11-17 Thresholding............................................................................................................................. 11-18 Image Processing Settings....................................................................................................... 11-19 Hollow Mode............................................................................................................................. 11-21 Mirrored Image ......................................................................................................................... 11-22

This section explains the physical controls of the internal camera, image acquisition, database settings, and image diagnostics. Note: Camera Setup only applies to the Quadrus Verifier internal camera. If using an external camera, images are received on an as-ready basis. Allow a 33mS delay for the first image to appear from an external camera.

Quadrus Verifier User’s Manual

11-1

Page 328

Camera Setup by ESP

Camera Setup by ESP

Click this button to bring up the Camera Setup menu.

To open the entire contents of the tree control, hold down the Alt key and single-click the +. To close the entire contents of the tree control, hold down the Alt key and single-click the - .

To open nested options, single-click the +.

11-2

To change a setting, double-click the setting and use your cursor to scroll through the options.

Quadrus Verifier User’s Manual

Page 329

Camera Setup

Camera Setup Serial Commands Region of Interest Camera Illumination Source Thresholding Processing Mode Multiple Symbols in Fast Linear Mode Image Processing Timeout Hollow Mode Mirrored Image

Quadrus Verifier User’s Manual

<K516,top,left,height,width> <K540,shutter speed,gain> <K535,illumination source> <K512,threshold mode,threshold value> <K513,processing mode> <K518,number of symbols> <K245,image processing timeout> <K517,hollow status> <K514,mirrored image>

11-3

Page 330

Video

Video In the Camera menu you can locate and capture images just as in EZ Mode when first starting ESP.

Locate Activates the target pattern and the video view in ESP to help you center the symbol in the field of view.

Calibrate If you haven’t already calibrated the symbol, 1. Click the Locate button and center the target pattern over the symbol. 2. Click the Calibrate button to optimize read rate. The Verifier will search through various IP (image processing) settings to determine the best configuration for verifying symbols. A successful calibration will display the calibrated symbol image a message, “Calibrated successfully”. 3. Click Close on the Calibration dialog. The symbol’s data and related features will be presented below the image display window.

Calibrate by Serial Command Send <@CAL> to begin calibration.

11-4

Quadrus Verifier User’s Manual